Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-06-13 Cont ID  
Sent By mjacobs Date 2005-06-13 Time 10:31 Rev Time 0.75
Received By mjacobs Date 2005-06-13 Time 10:31 Sent To PC
Notes
2005-06-13 00:00:00DENIED.
  
 1) FBC 104.2.1ALL INFORMATION,
 DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME
 AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR THE DESIGN.PLEASE COMPLY.
  
 2) 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 3) PROVIDE TWO COPIES OF ROOFING
 PRODUCTS WHICH WILL BE USED, ALONG WITH
 THE STATE COVER SHEETS.SEE FL. ADMIN
 CODE RULE 9B-72.VISIT WEB SITE @
 WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP
 FORSTATEWIDE PRODUCT APPROVAL.
  
 4) IS THE CONCRETE SLAB EXISTING OR NEW?
 IF NEW PROVIDE SLAB DETAILS FOR NEW AREA
 SHOWING FOOTINGS.
  
 5) MORE INFORMATION IS NEEDED FOR THE
 CONNECTION OF THE NEW ROOF TO THE
 EXISTING ROOF.
  
 BUILDING PLAN REVIEW
 MYRON JACOBS.
 TEL: (561)805-6726
 FAX: (561)659-8026
 [email protected]
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-20 Cont ID  
Sent By adarroug Date 2005-05-20 Time 13:41 Rev Time 0.00
Received By adarroug Date 2005-05-20 Time 13:41 Sent To B
Notes
2005-05-20 00:00:00TO "MISC" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-05-13 Cont ID  
Sent By adarroug Date 2005-05-13 Time 11:16 Rev Time 0.00
Received By adarroug Date 2005-05-13 Time 11:16 Sent To Z
Notes
2005-05-13 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status F Date 2005-05-19 Cont ID  
Sent By mmclean Date 2005-05-19 Time 17:30 Rev Time 0.00
Received By mmclean Date 2005-05-19 Time 17:30 Sent To I
Notes
2005-05-19 00:00:00DENIED,
 1. MUST PROVIDE AN UPDATED SURVEY, WHICH
 CAN BE AT LEAST 1 YEAR OLD.
 2. NEED TO BE CLEARER ON THE LOCATION OF
 THE NEW ADDITION, WITH SETBACKS
  
 MICHELLE MCLEAN
 ZONING TECHNICICAN
 805-6720