| Plan Review Stops For Permit 05050417 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-07-07 |
Time |
07:17 |
Rev Time |
1.00 |
| Received By |
mjacobs |
Date |
2005-07-07 |
Time |
06:32 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-02 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-02 |
Time |
07:54 |
Rev Time |
2.00 |
| Received By |
mjacobs |
Date |
2005-06-02 |
Time |
06:52 |
Sent To |
PC |
|
| Notes |
| 2005-06-01 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:05050417 | | | ADD:307 30TH ST. | | | CONT:WAYNE HETZEL BUILDING | | | TEL: (561)881-2108 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW:1ST | | | ACTION:DENIED | | | | | | 1) IMPACT FEES. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | PLEASE SUBMIT THE RECEIT WITH PLANS. | | | | | | 2) PLEASE SUBMIT PRODUCT APPROVALS WITH | | | THE EVALUATION AND TEST REPORTS | | | DOORS,WINDOWS,SHUTTERS ETC. | | | SUBMIT PRODUCT APPROVALS FOR THE | | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | | PRODUCT APPROVAL NUMBER (FL###), | | | AVAILABLE FROM THE DEPT OF COMMUNITY | | | AFFAIRS PRODUCT APPROVAL WEBSITE | | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | (IF YOU FIND THAT THE QUOTED WEB PAGE IS | | | NO LONGER AVAILABLE, PLEASE INFORM THE | | | PLAN REVIEWER) | | | | | | 3) FBC 2309.6ACCESS TO ATTIC SPACE | | | EACH ATTIC SPACE WITH A CLEAR HEIGHT OF | | | 24" OR GREATER SHALL BE PROVIDED WITH AN | | | INTERIOR ATTIC ACCESS OPENING NOT LESS | | | THAN 20"X 36". | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-13 |
Time |
11:56 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-10 |
Time |
16:42 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-28 |
Time |
12:10 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-06-28 |
Time |
12:04 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-05-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-23 |
Time |
08:13 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-23 |
Time |
07:50 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-10 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-10 |
Time |
10:55 |
Sent To |
E |
|
| Notes |
| 2006-03-10 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-08 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-08 |
Time |
15:31 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-20 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-20 |
Time |
14:11 |
Sent To |
E |
|
| Notes |
| 2005-05-20 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-07-07 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-05-10 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2005-05-10 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-07-06 |
Time |
12:04 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-07-06 |
Time |
12:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-05-28 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
prafter |
Date |
2005-07-06 |
Time |
12:03 |
Sent To |
B |
|
| Notes |
| 2005-05-28 00:00:00 | PLEASE HAVE MECHANICAL CONTRACTOR SUBMIT | | | PLANS FOR AIRCONDITIONING AND | | | VENTILSTION WHEN SUBMITTING APPLICATION. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-27 |
Time |
09:26 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-06-27 |
Time |
09:26 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-27 |
Time |
15:02 |
Rev Time |
0.60 |
| Received By |
kstevens |
Date |
2005-05-27 |
Time |
15:02 |
Sent To |
M |
|
| Notes |
| 2005-05-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1. SHOW OPENING FOR WATER CLOSET. | | | MINIMUM 15" OFF THE WALL AND 15" OFF THE | | | SHOWER TO CENTERLINE OF FIXTURE. MINIMUM | | | 30" OPENING REQUIRED. SECTION 405.3.1. | | | 2. SHOW SIZE OF SHOWER STALL. MINIMUM | | | 900 SQUARE INCHES. MINIMUM 30" INSIDE | | | FINISH WIDTH. SECTION 417.4. | | | 3. SANT. RISER DIAGRAM DOES NOT REFLECT | | | THE FLOOR PLAN. ONLY ONE LAV SHOWN ON | | | THE RISER DIAGRAM, AND TWO LAVS ARE | | | SHOWN ON THE FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-05-19 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-05-19 |
Time |
12:10 |
Sent To |
I |
|
| Notes |
| 2005-07-06 00:00:00 | MECH. PLAN REVIEW. | | | | | | A/C CONTRACTOR TO SUBMIT PLANS AT A/C | | | PERMIT TIME. | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|