Plan Review Details - Permit 05050417
Plan Review Stops For Permit 05050417
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-07-07 Cont ID  
Sent By mjacobs Date 2005-07-07 Time 07:17 Rev Time 1.00
Received By mjacobs Date 2005-07-07 Time 06:32 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-06-02 Cont ID  
Sent By mjacobs Date 2005-06-02 Time 07:54 Rev Time 2.00
Received By mjacobs Date 2005-06-02 Time 06:52 Sent To PC
Notes
2005-06-01 00:00:00BUILDING PLAN REVIEW
 PERMIT:05050417
 ADD:307 30TH ST.
 CONT:WAYNE HETZEL BUILDING
 TEL: (561)881-2108
  
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW:1ST
 ACTION:DENIED
  
 1) IMPACT FEES. THE PLANS SHALL BE TAKEN
 TO PALM BEACH COUNTY BUILDING DEPARTMENT
 FOR IMPACT FEE ASSESSMENT. THEY SHALL BE
 STAMPED AT THAT OFFICE AND A COPY OF THE
 PAID RECEIPT SUBMITTED TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
 PLEASE SUBMIT THE RECEIT WITH PLANS.
  
 2) PLEASE SUBMIT PRODUCT APPROVALS WITH
 THE EVALUATION AND TEST REPORTS
 DOORS,WINDOWS,SHUTTERS ETC.
 SUBMIT PRODUCT APPROVALS FOR THE
 NOTE: FL. ADMIN CODE RULE 9B-72 (IN
 EFFECT SINCE OCTOBER 1, 2003) REQUIRES
 THAT PRODUCTS HAVE STATEWIDE, LOCAL OR
 SITE-SPECIFIC PRODUCT APPROVAL.THE
 SUBMITTAL SHOULD INCLUDE THE STATEWIDE
 PRODUCT APPROVAL NUMBER (FL###),
 AVAILABLE FROM THE DEPT OF COMMUNITY
 AFFAIRS PRODUCT APPROVAL WEBSITE
 WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP
 (IF YOU FIND THAT THE QUOTED WEB PAGE IS
 NO LONGER AVAILABLE, PLEASE INFORM THE
 PLAN REVIEWER)
  
 3) FBC 2309.6ACCESS TO ATTIC SPACE
 EACH ATTIC SPACE WITH A CLEAR HEIGHT OF
 24" OR GREATER SHALL BE PROVIDED WITH AN
 INTERIOR ATTIC ACCESS OPENING NOT LESS
 THAN 20"X 36".
  
 BUILDING PLAN REVIEW
 MYRON JACOBS
 TEL: (561)805-6726
 FAX: (561)659-8026
 [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-03-13 Cont ID  
Sent By btrobaug Date 2006-03-13 Time 11:56 Rev Time 0.50
Received By btrobaug Date 2006-03-10 Time 16:42 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-06-28 Cont ID  
Sent By btrobaug Date 2005-06-28 Time 12:10 Rev Time 0.33
Received By btrobaug Date 2005-06-28 Time 12:04 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-05-23 Cont ID  
Sent By btrobaug Date 2005-05-23 Time 08:13 Rev Time 0.50
Received By btrobaug Date 2005-05-23 Time 07:50 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-03-10 Cont ID  
Sent By adarroug Date 2006-03-10 Time 10:55 Rev Time 0.00
Received By adarroug Date 2006-03-10 Time 10:55 Sent To E
Notes
2006-03-10 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-06-08 Cont ID  
Sent By shill Date 2005-06-08 Time 15:31 Rev Time 0.00
Received By shill Date 2005-06-08 Time 15:31 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-20 Cont ID  
Sent By adarroug Date 2005-05-20 Time 14:11 Rev Time 0.00
Received By adarroug Date 2005-05-20 Time 14:11 Sent To E
Notes
2005-05-20 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-07 Cont ID  
Sent By mjacobs Date 2005-07-07 Time 11:16 Rev Time 0.00
Received By mjacobs Date 2005-05-10 Time 15:52 Sent To  
Notes
2005-05-10 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2005-07-06 Cont ID  
Sent By prafter Date 2005-07-06 Time 12:04 Rev Time 1.00
Received By prafter Date 2005-07-06 Time 12:20 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-05-28 Cont ID  
Sent By hmoser Date 2005-05-28 Time 07:30 Rev Time 0.00
Received By prafter Date 2005-07-06 Time 12:03 Sent To B
Notes
2005-05-28 00:00:00PLEASE HAVE MECHANICAL CONTRACTOR SUBMIT
 PLANS FOR AIRCONDITIONING AND
 VENTILSTION WHEN SUBMITTING APPLICATION.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-06-27 Cont ID  
Sent By jleech Date 2005-06-27 Time 09:26 Rev Time 0.33
Received By jleech Date 2005-06-27 Time 09:26 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-05-27 Cont ID  
Sent By kstevens Date 2005-05-27 Time 15:02 Rev Time 0.60
Received By kstevens Date 2005-05-27 Time 15:02 Sent To M
Notes
2005-05-27 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1. SHOW OPENING FOR WATER CLOSET.
 MINIMUM 15" OFF THE WALL AND 15" OFF THE
 SHOWER TO CENTERLINE OF FIXTURE. MINIMUM
 30" OPENING REQUIRED. SECTION 405.3.1.
 2. SHOW SIZE OF SHOWER STALL. MINIMUM
 900 SQUARE INCHES. MINIMUM 30" INSIDE
 FINISH WIDTH. SECTION 417.4.
 3. SANT. RISER DIAGRAM DOES NOT REFLECT
 THE FLOOR PLAN. ONLY ONE LAV SHOWN ON
 THE RISER DIAGRAM, AND TWO LAVS ARE
 SHOWN ON THE FLOOR PLAN. SECTION
 104.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2005-05-19 Cont ID  
Sent By mmclean Date 2005-05-19 Time 12:10 Rev Time 0.00
Received By mmclean Date 2005-05-19 Time 12:10 Sent To I
Notes
2005-07-06 00:00:00MECH. PLAN REVIEW.
  
 A/C CONTRACTOR TO SUBMIT PLANS AT A/C
 PERMIT TIME.
 PAT RAFTER 561/805/6728 OR 805/6719
 PATTY KRAUSS.
 PLEASE CALL IF THEAR ANY QUESTIONS.