Plan Review Details - Permit 05050364
Plan Review Stops For Permit 05050364
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2005-05-06 Cont ID  
Sent By jwitmer Date 2005-05-06 Time 16:20 Rev Time 0.33
Received By jwitmer Date 2005-05-06 Time 16:20 Sent To PC
Notes
2005-05-06 00:00:00ROOF PROVISO:
 1507.3.8. ASPHALT SHINGLES LOW
 SLOPE ROOFING, UNDERLAYMENT APPLICATION
 FOR ROOF SLOPES FROM 2:12 UP TO 4:12,
 UNDERLAYMENT SHAL BE A MINIMUM OF TWO
 LAYERS APPLIED AS FOLLOWS:
 1) STARTING AT THE EAVE, A 19-INCH
 STRIP OF UNDERLAYMENT SHALL BE APPLIED
 PARALLEL WITH THE EAVE AND FASTENED
 SUFFICIENTLY TO STAY IN PLACE.
 2) STARTING AT THE EAVE, 36-INCH-WIDE
 STRIPS OF UNDERLAYMENT FELT SHALL BE
 APPLIED OVER LAPPING SUCCESSIVE SHEETS
 19 INCHES AND FASTENED SUFFICIENTLY TO
 STAY IN PLACE.
  
 N.O.A.-LIMITATIONS- SHALL NOT BE
 INSTALLED ON ROOF MEAN HEIGHTS IN ACCESS
 OF 33 FT.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2005-05-06 00:00:00OK PER E STILLINGS 5-6-05