| Plan Review Stops For Permit 05050315 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-09-06 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-09-21 |
Time |
16:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-24 |
Time |
00:03 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-24 |
Time |
00:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-09 |
Time |
06:43 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2005-06-07 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2005-06-09 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.) A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED, FS713.13. | | | | | | 2.)DECLARE AN OCCUPANCY FBC CHAPTER 4 | | | AND CLARIFY SYSTEMS USED.PLEASE SEE | | | CHAPTER 2, DEFINITIONS, DRY CLEANING | | | SYSTEMS, FBC305,FBC407.17.IF THE | | | BUSINESS PORTION IS A DIFFERENT | | | OCCUPANCY THAN THE DRY CLEANING, SHOW | | | REQUIRED SEPARATION FBC TABLE 704.1. | | | EXITS ARE TO COMPLY WITH FBC1004. | | | | | | 3.)PLEASE EXPLAIN WHY THERE IS A 2 HR | | | SEPARATION BETWEEN THE BOILER ROOM AND | | | THE TENANT SPACE, BUT APPARENTLY ONLY A | | | 1 HR BETWEEN THE BOILER ROOM AND THE | | | ADJACENT TENANT. | | | | | | 4.)2-A1 DOES NOT SHOW A FIRE RATING | | | FOR THE TENANT SEPARATION WALL.SEE | | | FBC704.3 AND CLARIFY. | | | | | | 5.)FBC1012.1.4, THE REST ROOM DOOR | | | BLOCKS THE PATH OF EGRESS. | | | | | | 6.)THE ENGINEER?S TITLE BLOCK IS TO BE | | | IN COMPLIANCE WITH FAC61G15-23.002. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-09-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-03 |
Time |
13:30 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-09-03 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2005-09-03 00:00:00 | ELECTRICAL PLANS STAMPED, OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-26 |
Time |
07:22 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-07-26 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2005-07-26 00:00:00 | ******** UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE MISSING INFORMATION | | | ON TITLE BLOCK FOR ARCHITECTUAL FIRM. | | | PLEASE SEE MISSING PRINTED NAME AND | | | LICENSE # FOR ARCH. | | | FAC 61G1-16.004 | | | PLEASE SEE THIS IS REQUIRED ON ALL | | | SHEETS AND FOR ALL TRADES WHEATHER OR | | | NOT COMMENT IS MADE BY OTHER | | | REVIEWER(S). | | | | | | 2)NOTE: PLEASE SEE PERMIT APPLICATION | | | VALUATION IS BASED ON ALL LABOR AND | | | MATERIALS, EVEN IF EQUIPMENT, MATERIALS | | | IS OWNER SUPPLIED. | | | PLEASE PROVIDE COMPLETE SIGNED CONTRACT | | | FOR ALL WORK AND MATERIALS FOR | | | VERIFICATION. | | | FBC 104.6.5 ADIMINISTRATIVE SECTIONS,. | | | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABVOE INFORMAITON FOR | | | REVIEW. IF THERE ARE ANY | | | QUESTIONS,PLEASE DO NOT HESITATE TO | | | CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-18 |
Time |
18:08 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-05-18 |
Time |
18:08 |
Sent To |
I |
|
| Notes |
| 2005-05-18 00:00:00 | *********** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002 FOR | | | ALL REQUIRED INFROMATION TO BE PRINTED | | | ON TITLE BLOCK. | | | PLEASE SEE MISSING PRINTED NAME AND | | | PRINTED LICENSE NUMBER OF PE. | | | | | | 2)NOTE: PLEASE SEE SERVICE IS SHOWN AS | | | 120/240V HOWEVER, PANEL "A" IS SHOWN AS | | | 120/208V FROM A 120/240V DISCONNECT ETC? | | | MISPRINT? | | | PLEASE CORRELATE. | | | | | | 3)NOTE: PLEASE SEE THIS APPEARS TO BE AN | | | EXSITING BUILDING, HOWEVER RISER IS | | | SHOWN AS NEWAND FOOTER STEEL TO BE | | | PART OF THE GROUNDING ELECTRODE SYSTEM. | | | PLEASE SEE 250.50, IF THIS WERE ARE NEW | | | BLDG THEN THIS WOULD BE REQUIRED, | | | HOWEVER EXISTING BLDG DONOT REQUIRE | | | ATTACHMENT TO "EXISTING" FOOTERS. PLEASE | | | SEE THIS IS ONL A NOTE AND FOOTER STEEL | | | ATTACHMENT IS PERMITTED BUT NOT | | | REQUIRED. IF SHOWN ON PLANS, THEN IT | | | WILL BE REQUIRED. | | | | | | 4)NOTE: PLEASE VERFIY NEW OR EXISTING | | | SIGN CIRCUIT PER 600.5 | | | | | | 5)NOTE: PLEASE VERIFY NEW OR EXISTING | | | RECEPTS ABOVE WINDOW/DISPLAY AREA. | | | 210.62, 220.12. | | | | | | 6)NOTE: PLEASE VERIFY RECEPT(S) FOR | | | ROOFTOP UNITS PER 210.63. THESE COULD | | | NOT BE LOCATED ON PLANS. | | | | | | 7)NOTE: PLEASE SEE OTHER REVIEW | | | COMMENTS. | | | VALUE FOR PERMIT APPLICATION IS BASED ON | | | TOTAL SCOPE OF WORK. THIS IS TO INCLUDE | | | ALL LABOR AND MATERIALS PER FBC 104.6.5 | | | EVEN IF EQUIPMENT ETC IS OWNER SUPPLIED. | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | REVIEWER(S) WHICH MAY AFFETC ELECTRICAL | | | PLANS. | | | | | | PLEASE BE SURE TO REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO COMPLETE SETS FOR REVIEW AND | | | STAMPING. ONE SET OF OLD/VOIDED SHEETS | | | SHOULD BE SEPARATE FOR REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-09 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-09 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-15 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-15 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-06-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-06-02 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-06-02 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2005-06-02 00:00:00 | ****DENIED**** | | | | | | 1) PLEASE ILLUSTRATE THE FIRE RATING OF | | | THE BOILER ROOM DOOR IN HOURS. IE 1 1/2 | | | HRS OR 90 MINUTES ETC. | | | | | | 2) 2A-10B,C RATED FIRE EXTINGUISHERS ARE | | | REQUIRED TO BE MOUNTED AT A TRAVEL | | | DISTANCE NOT TO EXCEED 75'. | | | | | | 3) ALL CONSTRUCTION, ALTERATION AND | | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE ALARM AND FIRE | | | SPRINKLER REMODELS IF APPLICABLE. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2951 OR 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-30 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-30 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2005-08-30 00:00:00 | TO "COMM" BD#21 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-20 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-20 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2005-07-20 00:00:00 | TO "COMM" BD#57 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-16 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-05-09 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2005-05-20 00:00:00 | TO "COMM" BD#28 | | 2005-05-09 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-20 |
Time |
15:06 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2005-09-20 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-26 |
Time |
20:38 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-07-26 |
Time |
20:18 |
Sent To |
|
|
| Notes |
| 2005-07-26 00:00:00 | DENIED: | | | MECHANICAL CONTRACTOR INDICATED WITH | | | PERMIT APPLICATION.PLAN SHEET A-5 | | | DETAIL FOR THE BOILER STACK & WATER | | | HEATER VENTSHALL COMPLY WITH 2001 | | | FBC(M)804.3.5 #2. | | | | | | SEE ALSO COMMENT #1 & 2 BY DEWEY PALMER, | | | ELECTRICAL PLANS EXAMINER. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
|
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-06-16 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-06-16 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2005-06-06 00:00:00 | PLAN DENIED | | | PLESE SUBMET THE MANUFACTURERS | | | INSULLATION INSTRUCTIONS FOR THE BOILER. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-09-21 |
Time |
16:56 |
Rev Time |
2.33 |
| Received By |
kstevens |
Date |
2005-09-21 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-08-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-22 |
Time |
08:47 |
Rev Time |
1.80 |
| Received By |
kstevens |
Date |
2005-08-22 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2005-08-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A. FROM PREVIOUS REVIEW | | | 3. SHT A-3 WATER HAMMER ARRESTORS SHALL | | | BE LOCATED IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING AS SHOWN. PDI-WH 201 AND | | | MANUF. INSTALLATION INSTRUCTIONS. | | | 5. THE FOLLOWING INFORMATION IS REQUIRED | | | FOR PERMIT APPLICATION: | | | D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2. - NO | | | MANUF. SHEETS FOR WATER HEATER | | | SUBMITTED. - MANUF. SHEET FOR BOILER | | | INDICATE 1,046,000 BTU, BUT ISOMETRIC | | | INDICATES 840,000 BTU. PLEASE CLARIFY. | | | **************NEW COMMENTS************** | | | 1B. SHT A-3 WATER RISER DIAGRAM SHOWS A | | | 3/4" COLD WATER LINE TO THE AIR | | | COMPRESSOR, BUT NO CONNECTION TO AIR | | | COMPRESSOR IS SHOWN ON THE MANUF. | | | SPECIFICATION SHEET. PLEASE CLARIFY WHAT | | | THE WATER LINE TO THE COMPRESSOR IS FOR. | | | IF CONNECTED TO THE COMPRESSOR, BACKFLOW | | | PROTECTION IS REQUIRED. SECTION 104.2.1. | | | 2B. SHT A-3 PIPE SIZING ON THE GAS RISER | | | DIAGRAM IS NOT CORRECT PER TABLE 402(2). | | | SEE RED LINE CORRECTIONS ON ONE SET OF | | | PLANS. | | | 3B. SEE COMMENT #1 OF THE ELECTRICAL | | | PLAN REVIEW CONCERNING THE TITLE BLOCK | | | OF THE ARCHITECT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-16 |
Time |
15:58 |
Rev Time |
2.24 |
| Received By |
kstevens |
Date |
2005-06-16 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2005-06-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHTS A-2, A-3, A-4 ENGINEER SHALL | | | LEGIBLY INDICATE THEIR NAME, ADDRESS AND | | | LICENSE NUMBER ON EACH SHEET. NAME AND | | | LICENSE NUMBER NOT SHOWN ON TITLE BLOCK. | | | FAC 61G15-23.002(2) & FS 471.025. | | | 2. SHT A-2 NOTES INDICATE FUTURE | | | FIXTURES WITH SAFE WASTE TO FLOOR SINK. | | | PLEASE CLARIFY. SAFE WASTE NOT APPROVED. | | | INDICATE IF INDIRECT WASTE W/AIR GAP | | | INTENDED. | | | 3. SHT A-2 PLUMBING NOTES: AIR CHAMBERS | | | ARE NOT APPROVED. DELETE NOTE. WATER | | | HAMMER ARRESTORS REQUIRED AT QUICK | | | CLOSING VALVES TO BE LOCATED NEAR THE | | | FIXTURE IN AN "EFFECTIVE RANGE" NOT IN | | | THE CEILING AS SHOWN. (REQD. AT W/M HOT | | | & COLD). PDI-WH 201 & MANUF. | | | INSTALLATION INSTRUCTIONS. | | | 4. SHT A-2 WATER RISER DIAGRAM. WATER | | | LINES TO THE HOSE BIBBS NOT SHOWN. | | | SECTION 104.3.1.1. - SHOW ALL WATER | | | PIPING ON RISER DIAGRAM. | | | 5. THE FOLLOWING INFORMATION IS REQUIRED | | | FOR PERMIT APPLICATION: | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. NOT ALL LENGTHS SHOWN. | | | SEE LINE FROM REGULATOR TO FIRST RISER. | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | C. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | | GAS CODE SECTION 304. | | | D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|