| Plan Review Stops For Permit 05050240 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-27 |
Time |
15:15 |
Rev Time |
0.15 |
| Received By |
spalmer |
Date |
2005-07-29 |
Time |
15:38 |
Sent To |
PC |
|
| Notes |
| 2005-07-29 00:00:00 | OKAY TO PRINT PER JIM WITMER IMPACT FEE | | | RECEIPT RECEIVED | | 2005-07-27 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PROVIDE THE IMPACT FEE RECEIPT. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-20 |
Time |
14:25 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-07-20 |
Time |
14:25 |
Sent To |
PC |
|
| Notes |
| 2005-07-20 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | THE FOLLOWING COMMENTS ARE ALL FROM THE | | | PREVIOUS REVIEW. | | | | | | 1.)PROVIDE A COPY OF THE IMPACT FEE | | | RECEIPT. | | | | | | 2.)WINDOW C DOES NOT MEET EMERGENCY | | | EGRESS REQUIREMENTS FBC1005.2.THE | | | ARCHITECT HAS ADDED A NOTE "ADJUST | | | SIZE".IT IS NOT ACCEPTABLE TO SPECIFY | | | A WINDOW WHICH IS CLEARLY NOT CODE | | | COMPLIANT AND ASK FOR THE CONTRACTOR TO | | | ADJUST THE SIZE IN THE FIELD.THE PLANS | | | ARE TO BE CODE COMPLIANT, AND THIS IS | | | CONSIDERED A LIFE SAFETY ISSUE.PLEASE | | | SPECIFY A COMPLIANT WINDOW.FEEL FREE | | | TO CONTACT ME IF YOU NEED ASSISTANCE. | | | | | | 3.)ADDITIONAL FEES DUE, SEE ATTACHED. | | | | | | 4.)PROVIDE A HURRICANE SHUTTER | | | INSTALLATION SCHEDULE, SEE ATTACHED. | | | | | | 5.)PLEASE PROVIDE PRODUCT APPROVALS | | | FOR THE FOLLOWING: | | | | | | FRONT DOOR (IMPACT GLASS) | | | FRENCH DOORS | | | SLIDIING GLASS DOOR | | | LOUVERS | | | ROOF (ILLEGIBLE) | | | | | | ANY PRODUCT APPROVALS NOT SUBMITTED | | | CORRECTLY PRIOR TO PERMIT ISSUANCE WILL | | | REQUIRE SEPARATE PERMITS. | | | | | | 6.)SEE ATTACHED FS553.80(2)(B). | | | | | | 7.)THE NOC IS EXPIRED, MORE THAN 90 | | | DAYS WITHOUT COMMENCING WORK FS713.13. | | | | | | WHEN RESUBMITTING, REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND SUBMIT OLD SHEETS | | | SEPARATELY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-11 |
Time |
21:25 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-06-11 |
Time |
21:25 |
Sent To |
PC |
|
| Notes |
| 2005-06-11 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.) PROVIDE A COPY OF THE IMPACT FEE | | | RECEIPT. | | | | | | 2.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC FBC13-101.2. | | | | | | 3.)THE SQUARE FOOTAGE ON THE ENERGY | | | CALC DOESN'T MATCH THE PLAN. | | | | | | 4.)WINDOW B IS REQUIRED TO BE SAFETY | | | GLASS FBC2405.1. | | | | | | 5.)WINDOW C DOES NOT MEET EMERGENCY | | | EGRESS REQUIREMENTS (SINGLE HUNG 48" | | | HIGH), FBC1005.2. | | | | | | 6.)ADDITIONAL FEES DUE, SEE ATTACHED | | | (VALUE ADJUSTMENT). | | | | | | 7.)A MEANS OF ESCAPE IS TO BE | | | PROVIDED, FBC1005.4.5.THE PLAN SHOWS A | | | WOOD DOOR BUT THE PRODUCT APPROVALS | | | SUBMITTED WERE FOR NON IMPACT GLAZED | | | DOORS. | | | | | | 8.)PROVIDE A HURRICANE SHUTTER | | | INSTALLATION SCHEDULE, SEE ATTACHED. | | | | | | 9.)IN ADDITION TO THE PRODUCT APPROVAL | | | FOR ITEM #7 ABOVE, PROVIDE PRODUCT | | | APPROVALS FOR: | | | SLIDING GLASS DOOR | | | LOUVERS | | | ROOF (ILLEGIBLE) | | | | | | NOTE THAT THE FLORIDA PRODUCT APPROVAL | | | FOR THE ROOF IS FOR TWO DIFFERENT | | | APPROVALS.PROVIDE THE SPECIFIC | | | APPROVAL FOR THE GAF ROYAL SOVEREIGN. | | | WWW.FLORIDABUILDING.ORG | | | | | | ANY PRODUCT APPROVALS NOT SUBMITTED | | | PRIOR TO ISSUANCE WILL REQUIRE SEPARATE | | | PERMITS FOR THOSE ITEMS. | | | | | | WHEN RESUBMITTING, REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND SUBMIT OLD SHEETS | | | SEPARATELY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-20 |
Time |
12:00 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-07-20 |
Time |
11:44 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-20 |
Time |
10:57 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-20 |
Time |
07:53 |
Sent To |
M |
|
| Notes |
| 2005-05-20 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PROVIDE OUTSIDE RECEPTACLES PER | | | 210.52(E). | | | | | | 2} RECEPTACLES MUST BE ADDED IN THE | | | KITCHEN PER 210.52(C)(1) SPACING. | | | | | | 3} SEE RECEPTACLE SPACING IN ALL BUT THE | | | LIVING ROOM, WILL NEED ADDED RECEPTACLES | | | TO COMPLY WITH 210.52(A)(1)&(2). | | | | | | 4} THE DINING ROOM MUST BE ON A SMALL | | | APPLIANCE CIRCUIT PER 210.52(B)(1). | | | | | | NOTE: THE PANEL IN THE LAUNDRY LOCATED | | | BETWEEN THE SINK ABD THE WASHING MACHINE | | | WOULD BE BETTER PLACED FOR FUTURE | | | MAINTENANCE IF IT WERE ON THE OPPOSITE | | | WALL. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-27 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-27 |
Time |
11:30 |
Sent To |
B |
|
| Notes |
| 2005-07-27 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-20 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-07-20 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
| 2005-07-20 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-12 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-12 |
Time |
15:32 |
Sent To |
P |
|
| Notes |
| 2005-07-12 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-01 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-01 |
Time |
14:17 |
Sent To |
Z |
|
| Notes |
| 2005-07-01 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-19 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-19 |
Time |
12:28 |
Sent To |
E |
|
| Notes |
| 2005-05-19 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-11 |
Time |
21:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-05-09 |
Time |
11:00 |
Sent To |
PC |
|
| Notes |
| 2005-05-09 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-05-20 |
Time |
13:15 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-05-20 |
Time |
13:15 |
Sent To |
P |
|
| Notes |
| 2005-05-20 00:00:00 | MECH. PLAN REVIEW: | | | | | | A/C O/KWITH PROVISO: | | | | | | PROVIDE FOR AUX. DRAIN PAN UNDER AHU | | | WITH OVER FLOW PROTECTION SW . | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-16 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-07-16 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-07-16 |
Time |
08:27 |
Sent To |
B |
|
| Notes |
| 2005-07-16 00:00:00 | PLUMBING PROVISO: | | | SHT P-1 | | | SEE RED LINE ON DWV ISOMETRIC. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-26 |
Time |
08:42 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-05-26 |
Time |
08:41 |
Sent To |
B |
|
| Notes |
| 2005-05-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHT P-1 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS. PLEASE | | | CORRECT THE FOLLOWING: | | | A. LOOP VENT DOWNSTREAM OF THE KITCHEN | | | SINK DOES NOT SERVE ANY PURPOSE. PLEASE | | | DELETE. SECTION 104.2.1 | | | B. THE KITCHEN SINK IS NOT VENTED AS | | | SHOWN. RECOMMEND AN AIR ADMITTENCE VALVE | | | FOR THE KITCHEN SINK OR AN ISLAND VENT. | | | SECTIONS 901.2.1, 913, & 917. | | | C. WASH MACHINE IS NOT VENTED PIPED AS | | | SHOWN. SECTION 901.2.1. - CLEANOUT SHALL | | | BE LOCATED 4FT ABOVE THE FLOOR. SECTION | | | 708.10. | | | D. LAV IN POWDER ROOM IS NOT VENTED | | | PIPED AS SHOWN. SECTION 901.2.1. | | | E. SHOW ALL PIPE SIZES. SECTION | | | 104.2.1. | | | F. SEE RED LINE CORRECTIONS ON ONE SET | | | OF PLANS FOR REFERENCE. | | | 2. SHT P-1 WATER RISER DIAGRAM, WATER | | | HAMMER ARRESTORS ARE REQUIRED AT THE | | | WASH MACHINE, AND IF THERE IS A DISH | | | WASHER AND/OR AN ICE MAKER IN THE REF. | | | SECTION 604.9. | | | 3. THE PERSONAL SEAL, SIGNATURE AND DATE | | | OF THE ARCHITECT SHALL APPEAR ON ALL | | | ARCHITECTURAL DOCUMENTS TO BE FILED FOR | | | PUBLIC RECORD. FAC 61G1-16.003 & FS | | | 481.2055. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-11 |
Time |
18:32 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-11 |
Time |
18:31 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-05-18 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-05-18 |
Time |
08:11 |
Sent To |
I |
|
| Notes |
| 2005-05-18 00:00:00 | DENIED, | | | 1. TOO MUCH CONCRETE WITHIN THE FRONT | | | SETBACK. (25FT). NEED TO REDUCE CONCRETE | | | WALK OR DRIVEWAY. | | | | | | MUST HAVE 1000SQ FT OR 75% OF LANDSCAPE | | | WITHIN THE 25FT FRONT SETBACK. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|