Plan Review Details - Permit 05050240
Plan Review Stops For Permit 05050240
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-07-29 Cont ID  
Sent By shill Date 2005-07-27 Time 15:15 Rev Time 0.15
Received By spalmer Date 2005-07-29 Time 15:38 Sent To PC
Notes
2005-07-29 00:00:00OKAY TO PRINT PER JIM WITMER IMPACT FEE
 RECEIPT RECEIVED
2005-07-27 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PROVIDE THE IMPACT FEE RECEIPT.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-07-20 Cont ID  
Sent By shill Date 2005-07-20 Time 14:25 Rev Time 1.00
Received By shill Date 2005-07-20 Time 14:25 Sent To PC
Notes
2005-07-20 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 THE FOLLOWING COMMENTS ARE ALL FROM THE
 PREVIOUS REVIEW.
  
 1.)PROVIDE A COPY OF THE IMPACT FEE
 RECEIPT.
  
 2.)WINDOW C DOES NOT MEET EMERGENCY
 EGRESS REQUIREMENTS FBC1005.2.THE
 ARCHITECT HAS ADDED A NOTE "ADJUST
 SIZE".IT IS NOT ACCEPTABLE TO SPECIFY
 A WINDOW WHICH IS CLEARLY NOT CODE
 COMPLIANT AND ASK FOR THE CONTRACTOR TO
 ADJUST THE SIZE IN THE FIELD.THE PLANS
 ARE TO BE CODE COMPLIANT, AND THIS IS
 CONSIDERED A LIFE SAFETY ISSUE.PLEASE
 SPECIFY A COMPLIANT WINDOW.FEEL FREE
 TO CONTACT ME IF YOU NEED ASSISTANCE.
  
 3.)ADDITIONAL FEES DUE, SEE ATTACHED.
  
 4.)PROVIDE A HURRICANE SHUTTER
 INSTALLATION SCHEDULE, SEE ATTACHED.
  
 5.)PLEASE PROVIDE PRODUCT APPROVALS
 FOR THE FOLLOWING:
  
 FRONT DOOR (IMPACT GLASS)
 FRENCH DOORS
 SLIDIING GLASS DOOR
 LOUVERS
 ROOF (ILLEGIBLE)
  
 ANY PRODUCT APPROVALS NOT SUBMITTED
 CORRECTLY PRIOR TO PERMIT ISSUANCE WILL
 REQUIRE SEPARATE PERMITS.
  
 6.)SEE ATTACHED FS553.80(2)(B).
  
 7.)THE NOC IS EXPIRED, MORE THAN 90
 DAYS WITHOUT COMMENCING WORK FS713.13.
  
 WHEN RESUBMITTING, REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND SUBMIT OLD SHEETS
 SEPARATELY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-06-11 Cont ID  
Sent By shill Date 2005-06-11 Time 21:25 Rev Time 1.00
Received By shill Date 2005-06-11 Time 21:25 Sent To PC
Notes
2005-06-11 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.) PROVIDE A COPY OF THE IMPACT FEE
 RECEIPT.
  
 2.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC FBC13-101.2.
  
 3.)THE SQUARE FOOTAGE ON THE ENERGY
 CALC DOESN'T MATCH THE PLAN.
  
 4.)WINDOW B IS REQUIRED TO BE SAFETY
 GLASS FBC2405.1.
  
 5.)WINDOW C DOES NOT MEET EMERGENCY
 EGRESS REQUIREMENTS (SINGLE HUNG 48"
 HIGH), FBC1005.2.
  
 6.)ADDITIONAL FEES DUE, SEE ATTACHED
 (VALUE ADJUSTMENT).
  
 7.)A MEANS OF ESCAPE IS TO BE
 PROVIDED, FBC1005.4.5.THE PLAN SHOWS A
 WOOD DOOR BUT THE PRODUCT APPROVALS
 SUBMITTED WERE FOR NON IMPACT GLAZED
 DOORS.
  
 8.)PROVIDE A HURRICANE SHUTTER
 INSTALLATION SCHEDULE, SEE ATTACHED.
  
 9.)IN ADDITION TO THE PRODUCT APPROVAL
 FOR ITEM #7 ABOVE, PROVIDE PRODUCT
 APPROVALS FOR:
 SLIDING GLASS DOOR
 LOUVERS
 ROOF (ILLEGIBLE)
  
 NOTE THAT THE FLORIDA PRODUCT APPROVAL
 FOR THE ROOF IS FOR TWO DIFFERENT
 APPROVALS.PROVIDE THE SPECIFIC
 APPROVAL FOR THE GAF ROYAL SOVEREIGN.
 WWW.FLORIDABUILDING.ORG
  
 ANY PRODUCT APPROVALS NOT SUBMITTED
 PRIOR TO ISSUANCE WILL REQUIRE SEPARATE
 PERMITS FOR THOSE ITEMS.
  
 WHEN RESUBMITTING, REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND SUBMIT OLD SHEETS
 SEPARATELY.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-07-20 Cont ID  
Sent By btrobaug Date 2005-07-20 Time 12:00 Rev Time 0.50
Received By btrobaug Date 2005-07-20 Time 11:44 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-05-20 Cont ID  
Sent By btrobaug Date 2005-05-20 Time 10:57 Rev Time 0.50
Received By btrobaug Date 2005-05-20 Time 07:53 Sent To M
Notes
2005-05-20 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PROVIDE OUTSIDE RECEPTACLES PER
 210.52(E).
  
 2} RECEPTACLES MUST BE ADDED IN THE
 KITCHEN PER 210.52(C)(1) SPACING.
  
 3} SEE RECEPTACLE SPACING IN ALL BUT THE
 LIVING ROOM, WILL NEED ADDED RECEPTACLES
 TO COMPLY WITH 210.52(A)(1)&(2).
  
 4} THE DINING ROOM MUST BE ON A SMALL
 APPLIANCE CIRCUIT PER 210.52(B)(1).
  
 NOTE: THE PANEL IN THE LAUNDRY LOCATED
 BETWEEN THE SINK ABD THE WASHING MACHINE
 WOULD BE BETTER PLACED FOR FUTURE
 MAINTENANCE IF IT WERE ON THE OPPOSITE
 WALL.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-07-27 Cont ID  
Sent By adarroug Date 2005-07-27 Time 11:30 Rev Time 0.00
Received By adarroug Date 2005-07-27 Time 11:30 Sent To B
Notes
2005-07-27 00:00:00TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status P Date 2005-07-20 Cont ID  
Sent By shill Date 2005-07-20 Time 11:16 Rev Time 0.00
Received By shill Date 2005-07-20 Time 11:16 Sent To E
Notes
2005-07-20 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status F Date 2005-07-12 Cont ID  
Sent By adarroug Date 2005-07-12 Time 15:32 Rev Time 0.00
Received By adarroug Date 2005-07-12 Time 15:32 Sent To P
Notes
2005-07-12 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-01 Cont ID  
Sent By adarroug Date 2005-07-01 Time 14:18 Rev Time 0.00
Received By adarroug Date 2005-07-01 Time 14:17 Sent To Z
Notes
2005-07-01 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-19 Cont ID  
Sent By adarroug Date 2005-05-19 Time 12:28 Rev Time 0.00
Received By adarroug Date 2005-05-19 Time 12:28 Sent To E
Notes
2005-05-19 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-11 Cont ID  
Sent By shill Date 2005-06-11 Time 21:26 Rev Time 0.00
Received By shill Date 2005-05-09 Time 11:00 Sent To PC
Notes
2005-05-09 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-05-20 Cont ID  
Sent By prafter Date 2005-05-20 Time 13:15 Rev Time 0.50
Received By prafter Date 2005-05-20 Time 13:15 Sent To P
Notes
2005-05-20 00:00:00MECH. PLAN REVIEW:
  
 A/C O/KWITH PROVISO:
  
 PROVIDE FOR AUX. DRAIN PAN UNDER AHU
 WITH OVER FLOW PROTECTION SW .
  
 PAT RAFTER 561/805/6728 OR 805/6719
 PATTY KRAUSS.
  
 PLEASE IF THEAR ANY QUESTIONS.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-07-16 Cont ID  
Sent By pschmitz Date 2005-07-16 Time 08:27 Rev Time 0.00
Received By pschmitz Date 2005-07-16 Time 08:27 Sent To B
Notes
2005-07-16 00:00:00PLUMBING PROVISO:
 SHT P-1
 SEE RED LINE ON DWV ISOMETRIC.

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-05-26 Cont ID  
Sent By kstevens Date 2005-05-26 Time 08:42 Rev Time 0.50
Received By kstevens Date 2005-05-26 Time 08:41 Sent To B
Notes
2005-05-26 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. SHT P-1 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS. PLEASE
 CORRECT THE FOLLOWING:
 A. LOOP VENT DOWNSTREAM OF THE KITCHEN
 SINK DOES NOT SERVE ANY PURPOSE. PLEASE
 DELETE. SECTION 104.2.1
 B. THE KITCHEN SINK IS NOT VENTED AS
 SHOWN. RECOMMEND AN AIR ADMITTENCE VALVE
 FOR THE KITCHEN SINK OR AN ISLAND VENT.
 SECTIONS 901.2.1, 913, & 917.
 C. WASH MACHINE IS NOT VENTED PIPED AS
 SHOWN. SECTION 901.2.1. - CLEANOUT SHALL
 BE LOCATED 4FT ABOVE THE FLOOR. SECTION
 708.10.
 D. LAV IN POWDER ROOM IS NOT VENTED
 PIPED AS SHOWN. SECTION 901.2.1.
 E. SHOW ALL PIPE SIZES. SECTION
 104.2.1.
 F. SEE RED LINE CORRECTIONS ON ONE SET
 OF PLANS FOR REFERENCE.
 2. SHT P-1 WATER RISER DIAGRAM, WATER
 HAMMER ARRESTORS ARE REQUIRED AT THE
 WASH MACHINE, AND IF THERE IS A DISH
 WASHER AND/OR AN ICE MAKER IN THE REF.
 SECTION 604.9.
 3. THE PERSONAL SEAL, SIGNATURE AND DATE
 OF THE ARCHITECT SHALL APPEAR ON ALL
 ARCHITECTURAL DOCUMENTS TO BE FILED FOR
 PUBLIC RECORD. FAC 61G1-16.003 & FS
 481.2055.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2005-07-11 Cont ID  
Sent By mmclean Date 2005-07-11 Time 18:32 Rev Time 0.00
Received By mmclean Date 2005-07-11 Time 18:31 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2005-05-18 Cont ID  
Sent By mmclean Date 2005-05-18 Time 08:11 Rev Time 0.00
Received By mmclean Date 2005-05-18 Time 08:11 Sent To I
Notes
2005-05-18 00:00:00DENIED,
 1. TOO MUCH CONCRETE WITHIN THE FRONT
 SETBACK. (25FT). NEED TO REDUCE CONCRETE
 WALK OR DRIVEWAY.
  
 MUST HAVE 1000SQ FT OR 75% OF LANDSCAPE
 WITHIN THE 25FT FRONT SETBACK.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720