Plan Review Details - Permit 05050207
Plan Review Stops For Permit 05050207
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-09-14 Cont ID  
Sent By rmcdouga Date 2005-09-14 Time 09:39 Rev Time 0.00
Received By rmcdouga Date 2005-09-14 Time 09:39 Sent To  
Notes
2005-09-14 00:00:00PROVISO
  
 1) A SEPARATE PERMIT AND FEES WILL BE
 REQUIRED FOR THE STORM PANELS.
2005-09-08 00:00:00NEEDS REVIEW, NEW SHEETS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-08-08 Cont ID  
Sent By rmcdouga Date 2005-08-08 Time 11:12 Rev Time 0.00
Received By rmcdouga Date 2005-08-08 Time 11:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-06-03 Cont ID  
Sent By rmcdouga Date 2005-06-03 Time 09:50 Rev Time 0.00
Received By rmcdouga Date 2005-06-03 Time 06:58 Sent To  
Notes
2005-06-03 00:00:00DENIED
  
 1) FBC TABLE 600 DOES NOT ALLOW WALL
 OPENINGS ON A ZERO LOT LINE. PLEASE
 RELOCATE THE VENT SHOWN AT THE GARAGE ON
 THE FLOOR PLAN ON A3.
  
 2) THE ANCHOR SCHEDULE ON A6 SPECIFIES
 USP THD210 HANGERS USING TAPCON
 FASTENERS. THESE CONNECTORS ARE NOT
 DESIGNED OR TESTED FOR USE WITH THESE
 FASTENERS. PLEASE SPECIFY AN APPROPRIATE
 MASONRY HANGER.
  
 3) SUBMIT THE MANUFACTURER'S SPECS. AND
 LISTING INFORMATION FOR THE ONE HOUR
 FIRE RATED GLASS BLOCK.
  
 4) SUBMIT THE EVAULATION REPORT FOR THE
 ROBICO SHUTTERS.
  
 5) THE PRODUCT APPROVAL SUBMITTED FOR
 THE GLAZED FRENCH DOORS LIMITS THE GLASS
 SIZE TO A MAXIMUM OF 14.869" WIDE AND
 55.619" IN HEIGHT. THE GLAZING IN THE
 DOORS SHOWN ON THE ELEVATION HAVE LARGER
 GLAZED AREAS. SUBMIT PRODUCT APPROVAL
 FOR DOORS THAT WILL BE INSTALLED.
  
 6) ADDITIONAL FEES ARE DUE FOR RADON AND
 INCREASED CALCULATED VALUE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2006-05-09 Cont ID  
Sent By btrobaug Date 2006-05-09 Time 15:44 Rev Time 0.50
Received By btrobaug Date 2006-05-09 Time 15:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-04-20 Cont ID  
Sent By btrobaug Date 2006-04-20 Time 14:06 Rev Time 0.50
Received By btrobaug Date 2006-04-20 Time 12:20 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-02-08 Cont ID  
Sent By btrobaug Date 2006-02-08 Time 10:28 Rev Time 0.50
Received By btrobaug Date 2006-02-08 Time 10:01 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-09-08 Cont ID  
Sent By dpalmer Date 2005-09-08 Time 17:28 Rev Time 0.40
Received By dpalmer Date 2005-09-08 Time 17:12 Sent To P
Notes
2005-09-08 00:00:00REDLINED THE FOLLOWING.
  
 PLEASE SEE MISSING KITCHEN COUNTERSPACE
 RECEPTS PER 210.52C1
 PLEASE SEE MISSING PWDR RM RECEPT.
 PLEASE SEE MISSING RECEPT

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-07-20 Cont ID  
Sent By btrobaug Date 2005-07-20 Time 16:07 Rev Time 0.50
Received By btrobaug Date 2005-07-20 Time 14:41 Sent To P
Notes
2005-07-20 00:00:00 
 THE PLANS MUST BE SIGNED BY THE PERSON
 WHOSE SEAL IS ATTACHED TO THE PLAN. SEE
 61G1-16.003 FAC.
  
 DO NOT SUBMIT AGAIN WITH ANOTHERS
 SIGNATURE ON MR. BRENNERS SEAL.
  
 CALL WITH QUESTIONS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-05-17 Cont ID  
Sent By btrobaug Date 2005-05-17 Time 09:17 Rev Time 0.50
Received By btrobaug Date 2005-05-17 Time 07:51 Sent To M
Notes
2005-05-17 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} INDICATE THE LOCATION OF PANEL "B".
  
 2} INDICATE LOCATION OF OVERCURRENT
 PROTECTION FOR PANELS "A" & "B".
  
 3} THE OCP FOR CIRCUITS 12,13 PANEL "A",
 12,13,14,15 PANEL "B" IS TOO LARGE FOR
 THE CONDUCTORS PER 210.16.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-05-06 Cont ID  
Sent By adarroug Date 2006-05-06 Time 14:48 Rev Time 0.00
Received By adarroug Date 2006-05-06 Time 14:48 Sent To E
Notes
2006-05-06 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-04-15 Cont ID  
Sent By adarroug Date 2006-04-15 Time 15:10 Rev Time 0.00
Received By adarroug Date 2006-04-15 Time 15:10 Sent To E
Notes
2006-04-15 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-02-07 Cont ID  
Sent By adarroug Date 2006-02-07 Time 11:23 Rev Time 0.00
Received By adarroug Date 2006-02-07 Time 11:23 Sent To E
Notes
2006-02-07 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-09-06 Cont ID  
Sent By adarroug Date 2005-09-06 Time 16:05 Rev Time 0.00
Received By adarroug Date 2005-09-06 Time 16:05 Sent To E
Notes
2005-09-06 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-18 Cont ID  
Sent By adarroug Date 2005-07-18 Time 11:55 Rev Time 0.00
Received By adarroug Date 2005-07-18 Time 11:55 Sent To E
Notes
2005-07-18 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-16 Cont ID  
Sent By adarroug Date 2005-05-16 Time 08:25 Rev Time 0.00
Received By adarroug Date 2005-05-16 Time 08:25 Sent To E
Notes
2005-05-16 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-03 Cont ID  
Sent By rmcdouga Date 2005-06-03 Time 10:30 Rev Time 0.00
Received By rmcdouga Date 2005-05-06 Time 14:12 Sent To  
Notes
2005-05-06 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-05-18 Cont ID  
Sent By prafter Date 2005-05-18 Time 08:07 Rev Time 0.50
Received By prafter Date 2005-05-18 Time 08:07 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-09-10 Cont ID  
Sent By jleech Date 2005-09-10 Time 07:20 Rev Time 0.33
Received By jleech Date 2005-09-10 Time 07:20 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-08-02 Cont ID  
Sent By jleech Date 2005-08-02 Time 09:06 Rev Time 0.33
Received By jleech Date 2005-08-02 Time 09:05 Sent To B
Notes
2005-08-02 00:00:00DENIED;
 THE WHO SIGNED CV-1 IS NOT THE SAME
 PERSON WHO SIGNED A-7. SEE ELECTRICAL
 PLAN REVIEW NOTES.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-05-26 Cont ID  
Sent By kstevens Date 2005-05-26 Time 07:59 Rev Time 0.50
Received By kstevens Date 2005-05-26 Time 07:59 Sent To B
Notes
2005-05-26 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1. SHT A-7 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS. PLEASE
 CORRECT THE FOLLOWING:
 A. BATH #3 TUB IS NOT VENTED. SECTION
 901.2.1.
 B. LAUNDRY TRAY, FITTINGS SHALL
 DIRECTION WASTE IN DIRECTION OF FLOW.
 TEE FITTINGS ARE NOT APPROVED. SECTION
 706.3. (SEE RED LINE CORRECTION ON ONE
 SET OF PLANS.
 C. CLEANOUT AT WASH MACHINE SHALL BE
 LOCATED 4FT. ABOVE THE FLOOR. SECTION
 708.10.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2005-05-13 Cont ID  
Sent By mmclean Date 2005-05-13 Time 15:31 Rev Time 0.00
Received By mmclean Date 2005-05-13 Time 15:31 Sent To I
Notes
***NONE***