| Plan Review Stops For Permit 05050201 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-09-19 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-09-19 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2005-09-19 00:00:00 | PROVISO | | | | | | 1) A SEPARATE PERMIT WITH ADDITIONAL | | | FEES WILL BE REQUIRED FOR THE STORM | | | PANELS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-06-03 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-06-03 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2005-06-03 00:00:00 | DENIED | | | | | | 1) PLEASE INDICATE ON THE PLAN THAT THE | | | GLASS BLOCK IN THE CABANA BATH IS ONE | | | HOUR FIRE RATED. FBC TABLE 600 DOES NOT | | | ALLOW OPENINGS ON THE ZERO LOT LINE. | | | | | | 2) THE ANCHOR SCHEDULE ON A6 SPECIFIES | | | USP THD 210 HANGERS USING TAPCON | | | FASTENERS. THESE CONNECTORS ARE NOT | | | DESIGNED OR TESTED FOR USE WITH THESE | | | FASTENERS. PLEASE SPECIFY AN APPROPRIATE | | | MASONRY HANGERS. | | | | | | 3) SUBMIT MANUFACTURER'S SPECS. AND | | | LISTING INFORMATION FOR THE ONE HOUR | | | FIRE RATED GLASS BLOCK. | | | | | | 4) THE 12' STRUCTURAL MULLION BETWEEN | | | THE SLIDING GLASS DOOR AND THE FIXED | | | GLASS TRANSOM EXCEEDS THE MAXIMUM | | | PRESSURE ALLOWED BY THE PRODUCT | | | APPROVAL. | | | | | | 5) THE 12' WIDE FIXED GLASS TRANSOM | | | ABOVE THE SGD EXCEEDS THE MAXIMUM WIDTH | | | ALLOWED BY THE PRODUCT APPROVAL. | | | | | | 6) THE 9' WIDE FIXED GLASS WINDOW ABOVE | | | THE (3) 25 SH WINDOWS IN THE DEN EXCEEDS | | | THE MAXIMUM WIDTH ALLOWED BY THE PRODUCT | | | APPROVAL. | | | | | | 7) SUBMIT THE EVALUATION/TEST REPORT FOR | | | THE ROBICO STORM PANELS. | | | | | | 8) SUBMIT (2) COPIES OF A KEY PLAN AND | | | INSTALLATION SCHEDULE FOR THE STORM | | | PANELS. SPECIFY THE MOUNT TYPE, FASTENER | | | TYPE AND FASTENER SPACING. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2006-05-09 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-03-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-10 |
Time |
08:40 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-10 |
Time |
08:40 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-02-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-24 |
Time |
09:12 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-02-24 |
Time |
06:52 |
Sent To |
PC |
|
| Notes |
| 2006-02-24 00:00:00 | | | | THESE COMMENTS WERE MADE ON 9/8/05 AND | | | HAVE NOT BEEN CORRECTED ON THE PLAN. IF | | | THESE ISSUES WERE CORRECTED IN THE FIELD | | | PLEASE CORRELATE THE DPAWINGS, IF NOT | | | CORRECTED IN THE FIELD, CORRECT SAME FOR | | | CODE COMPLIANCE. | | | | | | 1} KITCHEN COUNTERTOP RECEPTACLE PER | | | 210.52(C)(1), 210.8(A)(6). | | | | | | 2} POWDER ROOM RECEPTACLE PER 210.52(D), | | | 210.11(C)(3) AND 210.8(A)(1). | | | | | | 3} THE GROUNDING ELECTRODE CONDUCTOR | | | DOES NOT MEET THE MINIMUM SIZE REQUIRED | | | WHICH IS 1/0 CU PER 250.66. | | | | | | 4} MISSING RECEPTACLES FOR WALL SPACE | | | PER 210.52. SEE THE DEN AND BREAKFAST | | | ROOM ON REVIEWED PLAN FOR EXAMPLE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-08 |
Time |
17:05 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-09-08 |
Time |
16:31 |
Sent To |
P |
|
| Notes |
| 2005-09-08 00:00:00 | REDLINEDTHE FOLLOWING MISSING. | | | | | | | | | 210.52C1 FOR MISSING GFI ALONG KITCHEN | | | COUNTERSPACE. | | | 210.52D,210.11C3,210.8 FOR MISSING GFI | | | IN PWDR RM. | | | 210.52 FOR MISSING RECETPS FOR WALL | | | SPACE. | | | 250.66,310.15B6 FOR MIN GROUNDING | | | ELECTRODE CONDUCTOR. MIN 1/0. | | | | | | THE ABOVE SHOULD BE REVISED WITH ANY | | | OTHER REVISIONS BEFORE ROUGH ELECTRICAL | | | INSPECTION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-16 |
Time |
17:28 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-16 |
Time |
17:17 |
Sent To |
M |
|
| Notes |
| 2005-05-16 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} INDICATE THE LOCATION OF PANEL "B". | | | | | | 2} INDICATE LOCATION OF OVERCURRENT | | | PROTECTION FOR PANELS "A" & "B". | | | | | | 3} THE OCP FOR CIRCUITS 12,13 PANEL "A", | | | 12,13,14,15 PANEL "B" IS TOO LARGE FOR | | | THE CONDUCTORS PER 210.16. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-05-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-06 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-06 |
Time |
14:50 |
Sent To |
E |
|
| Notes |
| 2006-05-06 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-09 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-09 |
Time |
15:51 |
Sent To |
E |
|
| Notes |
| 2006-03-09 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-06 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-06 |
Time |
09:18 |
Sent To |
E |
|
| Notes |
| 2006-03-06 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-21 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-21 |
Time |
08:32 |
Sent To |
E |
|
| Notes |
| 2006-02-21 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-06 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-06 |
Time |
15:26 |
Sent To |
E |
|
| Notes |
| 2005-09-06 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-16 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-16 |
Time |
08:34 |
Sent To |
E |
|
| Notes |
| 2005-05-16 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-06-03 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-06 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2005-05-06 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2005-09-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-12 |
Time |
13:48 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2005-09-12 |
Time |
13:48 |
Sent To |
B |
|
| Notes |
| 2005-09-12 00:00:00 | 9-12-05 RECIVED ENERGY CALCULATIONS. | | | MECH. CONTRACTOR TO SUPPLY MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-05-18 |
Time |
07:42 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-05-18 |
Time |
07:42 |
Sent To |
P |
|
| Notes |
| 2005-05-18 00:00:00 | MECH. PLAN REVIEW: | | | | | | NO A/C PLAN OR EQUIPMENT INFORMATION. | | | | | | NO FL. ENERGY CALCULATIONS FOR | | | BUILDING. | | | | | | COUSIN AIR INC. LISTED ON PERMIT APP. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-10 |
Time |
07:09 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-09-10 |
Time |
07:09 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-26 |
Time |
08:19 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-05-26 |
Time |
08:19 |
Sent To |
B |
|
| Notes |
| 2005-05-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1. SHT A-7 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE, NOR DOES IT REFLECT THE | | | FLOOR PLAN. PLEASE CORRECT THE | | | FOLLOWING: | | | A. THE GARAGE SINK SHALL NOT DRAIN | | | THROUGH THE HORIZONTAL WET VENT OF THE | | | BATHROOM FIXTURES. THIS SINK SHALL | | | DISCHARGE DOWNSTREAM OF THE BATHROOM | | | FIXTURES. SECTION 909.1 | | | B. THE CABANA BATH SHOWN ON THE FLOOR | | | PLAN IS NOT SHOWN ON THE SANT. RISER | | | DIAGRAM. SECTION 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-05-13 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-05-13 |
Time |
15:53 |
Sent To |
I |
|
| Notes |
|
|