| Plan Review Stops For Permit 05050150 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-11-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-30 |
Time |
16:44 |
Rev Time |
0.25 |
| Received By |
alange |
Date |
2005-11-30 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-22 |
Time |
15:54 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2005-11-22 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2005-11-22 00:00:00 | DENIED | | | | | | 1.BUILDING REVIEW OK. | | | | | | 2.SUBMIT TWO COPIES OF PLANS FOR | | | REVIEW. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-05-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-05-19 |
Time |
15:38 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2005-05-19 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-11-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-30 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-11-30 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-11-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-30 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-11-30 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2005-11-30 00:00:00 | ** UNSAT 2ND REVIEW ** | | | | | | 1)NOTE: PLEASE SEE NEW SHEET IS NOW | | | SUBMITTED WITH CORRECTIONS OF REDLINES, | | | HOWEVER PLEASE SEE ONLY ONE COPYWAS | | | SUBMITTED FOR REVIEW AND STAMPING. | | | PLEASE SUBMIT TWO COPIES OF PLANS. | | | | | | | | | IF THERE ARE ANYQUESTIONS, PLEASE | | | CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-18 |
Time |
18:31 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-05-18 |
Time |
18:25 |
Sent To |
I |
|
| Notes |
| 2005-05-18 00:00:00 | ********* PLANS REDLINED ********** | | | | | | 1)NOTE: PLEASE SEE OCP FOR 5KW HEAT IS | | | SHOWN AT 20A'S WITH A 24A CONNECTED | | | LOAD. PLEASE SEE 424.3B WHICH REQUIRED | | | OCP TO BE A MIN OF 125%. | | | THIS WAS REDLINED AND PLANS DO NOT NEED | | | TO BE REVISED, HOWEVER IF PLANS COME | | | BACK FOR ANY OTHER COMMENTS OR REVSIONS, | | | PLEASE CORRECT AT THAT TIME. | | | | | | *************************************** |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-12-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-12-02 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-12-02 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-05-20 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-20 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-09 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-09 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2005-11-22 00:00:00 | TO "COMM" BD#20 | | 2005-11-09 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-17 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-17 |
Time |
07:46 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-17 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-05-04 |
Time |
16:09 |
Sent To |
PC |
|
| Notes |
| 2005-05-17 00:00:00 | TO "COMM" BD#27 | | 2005-05-04 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-12-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-12-08 |
Time |
06:50 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-12-08 |
Time |
06:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-08 |
Time |
10:34 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-06-08 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2005-06-08 00:00:00 | DENIED: | | | 1.PROVIDE DETAIL FOR THE CONDENSING | | | UNIT RACK. | | | | | | 2.INDICATE ELEVATION OF THE CONDESING | | | UNIT.PER 2001 FBC(M)306.5, EQUIPMENT | | | LOCATED AT A HEIGHT GREATER THAN 16 FT | | | REQUIRE PERMANENT MEANS OF ACCESS. | | | | | | 3.PROVIDE CLEARANCES BETWEEN THE | | | CONDESING UNIT & THE EXTERIOR WALL. | | | REFERENCE MANUFACTURER INSTALLATION | | | INSTRUCTIONS FOR REQUIRED CLEARANCE. | | | PLEASE NOTE, PER 2001 FBC(M)306.1, | | | CLEARANCES AROUND EQUIPMENT INCLUDING | | | OTHER INSTALLED EQUIPMENT (THE | | | DISCONNECT).CLEARANCE SHALL BE | | | SUFFICIENT TO ALLOW INSPECTION, SERVICE | | | OR REPLACEMENT WITHOUT REMOVING ELEMENTS | | | OF PERMANENT CONSTRUCTION. | | | | | | 4.PLAN INDICATES FRESH AIR INTAKE 3 FT | | | FROM THE CONDENSING UNIT IN WHICH THE | | | FAN IS EXHAUSTING HEAT.THIS AIR SHOULD | | | NOT BE RECIRCULATED PER 2001 FBC(M) | | | 501.3 & 401.5.1.PLEASE NOTE, THE | | | OPENING LOCATION SHALL BE A MINIMUM OF | | | 10 FT FROM PARKING LOTS, STREETS OR | | | ALLEYS. | | | | | | 5.PROVIDE DETAIL FOR THE HANGING OF | | | THE AHU. | | | | | | 6.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 | | | FBC(M)307.2.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-12-08 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-12-08 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-12-08 |
Time |
07:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-17 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-06-17 |
Time |
07:04 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-06-17 |
Time |
07:04 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-12-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-08 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-08 |
Time |
14:45 |
Sent To |
M |
|
| Notes |
| 2005-12-08 00:00:00 | DENIED, | | | 1. MUST PROVIDE TWO CURRENT COPY OF | | | SURVEY OR SITEPLAN SHOWING THE LOCATION | | | OF THE UNIT (A/C) | | | | | | NOTE: A/C UNIT CAN ONLY ENCROACH 4FT | | | INTO A SETBACK. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-08 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-08 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2005-06-08 00:00:00 | DENIED, | | | 1. NEED TO PROVIDE TWO COPY OF UPDATED | | | SURVEY SHOWING THE LOCATION OF THE CM | | | WALL TO COVER THE A/C | | | | | | MICHELLE MCLEAN | | | ZONING TECHICIAN | | | 805-6720 |
|
|