| 2005-05-27 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT:05050122 |
| | ADD:1537 6TH ST. |
| | CONT:KING NORMAN E & JOANNE |
| | TEL: (561)820-8729 |
| | |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW:1ST |
| | ACTION:DENIED |
| | |
| | FBC = FLORIDA BUILDING CODE 2001 |
| | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| | F.S.= FLORIDA (STATE) STATUTE |
| | |
| | 1) 104.3.1.1.COUNTY AMENDMENTS: |
| | PLAN REVIEW MINIMUM REQUIREMENTS FOR |
| | PLAN REVIEW BUILDINGS. |
| | 1) SITE REQUIREMENTS,SET BACK SEPERA- |
| | TION (ASSUMED PROPERTY LINE) |
| | |
| | 2) STRUCTURAL REQUIREMENTS SHALL |
| | INCLUDE: |
| | FLOOR PLAN, WALL SECTIONS FROM THE |
| | FOUNDATION THROUGH THE ROOF, INCLUD- |
| | ING ASSEMBLY (PRODUCT APPROVALS) & |
| | MATERIALS, CONNECTOR TABLES, WIND |
| | REQUIREMENTS, STRUCTURAL CALCULA- |
| | TIONS (IF REQUIRED) |
| | |
| | 2)1507.3.8. ASPHALT SHINGLES LOW SLOPE |
| | ROOFING, UNDERLAYMENT APPLICATION FOR |
| | ROOF SLOPES FROM 2:12 UP TO 4:12, |
| | UNDERLAYMENT SHAL BE A MINIMUM OF TWO |
| | LAYERS APPLIED AS FOLLOWS: |
| | 1) STARTING AT THE EAVE, A 19-INCH |
| | STRIP OF UNDERLAYMENT SHALL BE APPLIED |
| | PARALLEL WITH THE EAVE AND FASTENED |
| | SUFFICIENTLY TO STAY IN PLACE. |
| | 2) STARTING AT THE EAVE, 36-INCH-WIDE |
| | STRIPS OF UNDERLAYMENT FELT SHALL BE |
| | APPLIED OVER LAPPING SUCCESSIVE SHEETS |
| | 19 INCHES AND FASTENED SUFFICIENTLY TO |
| | STAY IN PLACE. |
| | |
| | N.O.A.-LIMITATIONS- SHALL NOT BE |
| | INSTALLED ON ROOF MEAN HEIGHTS IN ACCESS |
| | OF 33 FT. |
| | |
| | 3)) PROVIDE PRODUCT APPROVALS FOR |
| | DOOR-ASPHALT SHINGLES-ALL STRAPS AND |
| | TIE DOWNS. |
| | PRODUCT APPROVALS SUBMITTED WITH PERMIT |
| | APPLICATION AFTER OCTOBER 1, 2003 ARE |
| | REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 4)ALLINFORMATION/DRAWINGS/SPECIFICATIONS |
| | AND ACCOMPANYING DATA SHALL BEAR THE |
| | NAME AND SIGNATURE OF THE PERSON RESPON- |
| | SIBLE FOR THE DESIGN. SECTION 104.2.1 |
| | |
| | 5) PROVIDE A CORSS SECTIONAL DRAWING |
| | SHOWING DETAILS OF STRUCTURE AND TYPES |
| | OF MATERIALS AND SPACING OF FLOOR/ROOF |
| | JOISTS. |
| | |
| | 6) FBC* TABLE 2307.6B THE MINIMUM |
| | THICKNESS FOR WALLS AND FLOOR SHEETING |
| | IS 5/8". ALSO PLEASE SEE FBC*TABLE |
| | 2309.3A ALSO SHOW THE 10" ELEVATION OFF |
| | THE GROUND. |
| | |
| | BUILDING PLAN REVIEW |
| | MYRON JACOBS |
| | TEL: (561)805-6726 |
| | FAX: (561)659-8026 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |