| Plan Review Stops For Permit 05050064 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-06-30 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-06-30 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2005-06-30 00:00:00 | PROVISO | | | | | | 1) SUBMIT STATE/LOCAL PRODUCT APPROVAL | | | FOR THE DOUBLE OUTSWING ELIPTICAL FRONT | | | DOORS PRIOR TO INSTALLATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-05-26 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-05-26 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2005-05-26 00:00:00 | DENIED | | | | | | 1)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) FBC 1909.3 REQUIRES WWF TO BE | | | SUPPORTED AT A MINIMUM OF 3' ON CENTER. | | | ALSO FIRED CLAY BRICKS ARE NOT APPROVED | | | SUPPORTS FOR THE WWF. | | | | | | 4) THE MAIN EGRESS DOOR IS REQUIRED TO | | | COMPLY WITH FBC 1012. THE ACTIVE LEAF OF | | | THE DOUBLE DOOR MUST PROVIDE A 32" | | | MINIMUM CLEAR OPENING. SEE FBC 1012. | | | | | | 5) THE FLOOR TRUSS BUCKET DETAIL ON A5 | | | IS MISLABELED AS 1 ON A6. | | | | | | 6) DETAIL 2 ON A10 SPECIFIES 5/8" STUCCO | | | ON THE CLERESTORY. ASTM C 926 REQUIRES | | | THE STUCCO TO BE 7/8" THICK WHEN APPLIED | | | ON METAL LATH OVER A PLYWOOD BASE. | | | | | | 7) SUBMIT THE LISTING AND MANUFACTURER'S | | | SPECIFICATIONS/INSTALLATION INSTRUCTIONS | | | FOR THE OUTDOOR BBQ GRILL. | | | | | | 8) SUBMIT FL PRODUCT APPROVAL FOR THE | | | 'ELIPTICAL' FRONT DOUBLE DOORS. | | | | | | 9) SUBMIT FL PRODUCT APPROVAL FOR THE | | | SINGLE AND DOUBLE 'ELIPTICAL' GLAZED | | | FRENCH DOORS WITHOUT SIDELITES. | | | | | | 10) SUBMIT FL PRODUCT APPROVALS FOR THE | | | 'ELIPTICAL' CASEMENT WINDOWS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-11 |
Time |
14:04 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-09-11 |
Time |
14:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-08-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-18 |
Time |
08:59 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-08-18 |
Time |
06:39 |
Sent To |
PC |
|
| Notes |
| 2006-08-18 00:00:00 | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} LIGHTING FIXTURS ARE REQUIRED AS A | | | CONDITION OF CO. ONLY JUNCTION BOXES ARE | | | SHOWN ON THE PLAN IN THE FOYER AND AT | | | THE ENTRY. INDICATE BY SYMBOL, FIXTURES | | | THAT ARE REQUIRED BY ARTICLE | | | 210.70(A),(B),AND(C). | | | | | | 2} A DISPOSER HAS BEEN ADDED FOR THE | | | ISLAND SINK. IT DOES NOT APPEAR ON THE | | | PANEL SCHEDULE AND THEREFORE IN THE | | | CALCULATIONS. PLEASE LOCATE IN PROPER | | | PANEL AND CALCULATE PER 220.30, SINCE | | | THAT APPEARS TO BE THE CALCULATION | | | METHOD BEING USED. | | | | | | 3} A WINE COOLER AND ICE MACHINE/MAKER | | | HAVE BEEN ADDED TO THE PLAN BUT NOT THE | | | SCHEDULE, SEE NOTE #2. | | | | | | 4} BATH #3 RECEPTACLE AT THE VANITY DOES | | | NOT MEET THE 3' SPACING REQUIREMENT OF | | | 210.52(D). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-03-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-22 |
Time |
13:33 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-03-22 |
Time |
13:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-10 |
Time |
17:48 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-10 |
Time |
17:47 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-05 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-05 |
Time |
10:54 |
Sent To |
E |
|
| Notes |
| 2006-09-05 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-14 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-14 |
Time |
16:47 |
Sent To |
M |
|
| Notes |
| 2006-08-14 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-08-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-12 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-12 |
Time |
14:51 |
Sent To |
E |
|
| Notes |
| 2006-08-12 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-29 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-29 |
Time |
13:31 |
Sent To |
M |
|
| Notes |
| 2006-06-29 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-06 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-06 |
Time |
12:00 |
Sent To |
M |
|
| Notes |
| 2006-06-06 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-16 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-16 |
Time |
17:48 |
Sent To |
E |
|
| Notes |
| 2006-03-16 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-28 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-28 |
Time |
09:15 |
Sent To |
B |
|
| Notes |
| 2005-06-28 00:00:00 | TO "RMCDOUGAL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-10 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-10 |
Time |
16:30 |
Sent To |
E |
|
| Notes |
| 2005-05-10 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-05-26 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-05-03 |
Time |
18:17 |
Sent To |
|
|
| Notes |
| 2005-05-03 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-16 |
Time |
16:25 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2006-08-16 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2006-08-16 00:00:00 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-29 |
Time |
14:54 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2006-06-29 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2006-06-29 00:00:00 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) RETURN AIR TRANSFER DUCT TO MASTER | | | SUITE IS TO SMALL IT NEEDS TO BE 15" OR | | | LARGER, SEE NOTE #2 (A) & (C) 'EXCEPT'. | | | | | | 2) BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-15 |
Time |
10:21 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-06-15 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2006-06-15 00:00:00 | *** DENIED *** | | | 1) SUPPLY AIR DUCT TO DINNING ROOM IS | | | NOT SIZED, PLEASE CORRECT. | | | | | | 2) CHECK THE SIZE OF THE SUPPLY AIR DUCT | | | TO THE BREAKFAST ROOM 11" PLEASE CORRECT | | | | | | 3) PAGE M-2, WATER CLOSET IN MASTER | | | SUITE #3 NEEDS A EXHAUST FAN PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-05-16 |
Time |
11:13 |
Rev Time |
0.75 |
| Received By |
prafter |
Date |
2005-05-16 |
Time |
11:13 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-05-17 |
Time |
18:18 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-05-17 |
Time |
18:18 |
Sent To |
B1 |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-05-10 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-05-10 |
Time |
11:42 |
Sent To |
I |
|
| Notes |
| 2005-05-10 00:00:00 | MUST PULL SEPERATE PERMIT FOR | | | POOL/SPA/DECK/SCREEN ENCLOSURE & | | | SEPERATE PERMIT FOR GATE/WALL/FENCES | | | WITH EASEMENT APPROVAL FROM CITY OF WEST | | | PALM BEACH. | | | |
|
|