Plan Review Details - Permit 05050002
Plan Review Stops For Permit 05050002
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-05-02 Cont ID  
Sent By jwitmer Date 2005-05-02 Time 09:06 Rev Time 0.00
Received By jwitmer Date 2005-05-02 Time 09:06 Sent To  
Notes
2005-05-02 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05050002
 ADD: 801 34TH ST
 CONT:O/B DARRIN SMITH
 TEL: (561)842-3247
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: REVIEWED
  
 1507.3.8. ASPHALT SHINGLES LOW
 SLOPE ROOFING, UNDERLAYMENT APPLICATION
 FOR ROOF SLOPES FROM 2:12 UP TO 4:12,
 UNDERLAYMENT SHAL BE A MINIMUM OF TWO
 LAYERS APPLIED AS FOLLOWS:
 1) STARTING AT THE EAVE, A 19-INCH
 STRIP OF UNDERLAYMENT SHALL BE APPLIED
 PARALLEL WITH THE EAVE AND FASTENED
 SUFFICIENTLY TO STAY IN PLACE.
 2) STARTING AT THE EAVE, 36-INCH-WIDE
 STRIPS OF UNDERLAYMENT FELT SHALL BE
 APPLIED OVER LAPPING SUCCESSIVE SHEETS
 19 INCHES AND FASTENED SUFFICIENTLY TO
 STAY IN PLACE.
  
 N.O.A.-LIMITATIONS- SHALL NOT BE
 INSTALLED ON ROOF MEAN HEIGHTS IN ACCESS
 OF 33 FT.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2005-05-02 Cont ID  
Sent By ptjomsto Date 2005-05-02 Time 08:54 Rev Time 0.00
Received By ptjomsto Date 2005-05-02 Time 08:54 Sent To  
Notes
2005-05-02 00:00:00HISTORIC APPROVED 5/2/05 BY N F