Plan Review Details - Permit 05042228
Plan Review Stops For Permit 05042228
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-08-22 Cont ID  
Sent By alange Date 2005-08-22 Time 14:13 Rev Time 0.25
Received By alange Date 2005-08-22 Time 14:13 Sent To  
Notes
2005-08-22 00:00:00NEW SHUTTER SCHDL REC.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-07-21 Cont ID  
Sent By alange Date 2005-07-21 Time 08:58 Rev Time 1.50
Received By alange Date 2005-07-21 Time 08:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-05-23 Cont ID  
Sent By alange Date 2005-05-23 Time 07:19 Rev Time 3.00
Received By alange Date 2005-05-23 Time 08:20 Sent To  
Notes
2005-05-23 00:00:00DENIED
  
  
 1. FBC* 104.6.5BUILDING PERMIT
 VALUATION.THE STATED VALUE OF THE
 PROJECT HAS BEEN UNDER-ESTIMATED AT
 $185,220.THE VALUE, CALCULATED USING
 THE SOUTHERN BUILDING CODE CONGRESS
 INTERNATIONAL (SBCCI) VALUATION TABLES,
 IS $268,860.THE PERMIT APPLICATION FEE
 HAS BEEN ADJUSTED ACCORDINGLY, SO THERE
 IS AN OUTSTANDING BALANCE OF $844.77.
 THE REQUIRED AMOUNT SHALL BE PAID BEFORE
 THE PLANS CAN BE RESUBMITTED.
  
 2.SUBMIT 2 COPIES OF MANUFACTURERS
 SPECS FOR BUILT-INBBQ.
  
 3. FBC 1707.4.4.2SHOW BUCK DETAIL
 COMPLYING WITH THIS SECTION.BUCK SHALL
 HAVE FULL SUPPORT OF THE FRAME.
  
 4. 1 OF A/7 FINISH GRADE FBC 1804.1.7
 WPB AMMENDMENTS FINISHED FLOOR SHALL BE
 4" ABOVE GRADE MINIMUM.
 THE BOTTOM OF FOUNDATION SHALL EXTEND NO
 LESS THAN 12" BELOW GRADE. FBC 1804.2.3
 THESE ARE BOTH MINIMUMS. THIS LEAVES NO
 ROOM FOR ERROR OF THE FINISHED GRADE.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-03-14 Cont ID  
Sent By btrobaug Date 2006-03-14 Time 13:33 Rev Time 0.33
Received By btrobaug Date 2006-03-14 Time 13:33 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-01-31 Cont ID  
Sent By jleahy Date 2006-01-31 Time 21:44 Rev Time 0.30
Received By jleahy Date 2006-01-31 Time 21:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-07-11 Cont ID  
Sent By btrobaug Date 2005-07-11 Time 11:27 Rev Time 0.50
Received By btrobaug Date 2005-07-11 Time 10:45 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-05-10 Cont ID  
Sent By btrobaug Date 2005-05-10 Time 09:00 Rev Time 0.50
Received By btrobaug Date 2005-05-10 Time 08:33 Sent To M
Notes
2005-05-10 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} INDICATE THE LOCATION OF PANEL "B".
  
 2} INDICATE LOCATION OF OVERCURRENT
 PROTECTION FOR PANELS "A" & "B".
  
 3} THE OCP FOR CIRCUITS 12,13 PANEL "A",
 12,13,14,15 PANEL "B" IS TOO LARGE FOR
 THE CONDUCTORS PER 210.16.
  
 4} THE POWDER ROOM REQUIRES A GFI
 RECEPTACLE PER 210.8(A) & 210.52(D).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-03-13 Cont ID  
Sent By adarroug Date 2006-03-13 Time 14:48 Rev Time 0.00
Received By adarroug Date 2006-03-13 Time 14:48 Sent To E
Notes
2006-03-13 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-08-18 Cont ID  
Sent By adarroug Date 2005-08-18 Time 16:28 Rev Time 0.00
Received By adarroug Date 2005-08-18 Time 16:28 Sent To B
Notes
2005-08-18 00:00:00TO "ALANGE" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-07-08 Cont ID  
Sent By adarroug Date 2005-07-08 Time 14:09 Rev Time 0.00
Received By adarroug Date 2005-07-08 Time 14:09 Sent To E
Notes
2005-07-08 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-06-24 Cont ID  
Sent By adarroug Date 2005-06-24 Time 16:35 Rev Time 0.00
Received By adarroug Date 2005-06-24 Time 16:35 Sent To Z
Notes
2005-06-24 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-09 Cont ID  
Sent By adarroug Date 2005-05-09 Time 10:51 Rev Time 0.00
Received By adarroug Date 2005-05-09 Time 10:51 Sent To E
Notes
2005-05-09 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-05-23 Cont ID  
Sent By alange Date 2005-05-23 Time 07:19 Rev Time 0.00
Received By alange Date 2005-04-29 Time 17:59 Sent To  
Notes
2005-04-29 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2005-07-19 Cont ID  
Sent By rregueir Date 2005-07-19 Time 17:26 Rev Time 0.00
Received By rregueir Date 2005-07-19 Time 17:25 Sent To B
Notes
2005-07-19 00:00:00ENERGY CALCULATIONS AND MANUAL J
 SUBMITTIED.NO PLANS
 RJR

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-05-16 Cont ID  
Sent By prafter Date 2005-05-16 Time 10:40 Rev Time 0.75
Received By prafter Date 2005-05-16 Time 10:40 Sent To P
Notes
2005-05-16 00:00:00MECH.PLAN REVIEW:
  
 NO FL. ENERGY CALCULATIONS /A/C PLANS
 OR EQUIPMENT INFORMATION.
 COUSINS AIR INC. LISTED ON PERMIT APP.
 PAT RAFTER 561/805/6728 OR 805/6719
 PATTY KRAUSS.
 PLEASE CALL IF THEAR ANY QUESTIONS.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-07-18 Cont ID  
Sent By jleech Date 2005-07-18 Time 09:36 Rev Time 0.33
Received By jleech Date 2005-07-18 Time 09:36 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-05-17 Cont ID  
Sent By jleech Date 2005-05-17 Time 18:48 Rev Time 0.33
Received By jleech Date 2005-05-17 Time 18:48 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2005-07-07 Cont ID  
Sent By mmclean Date 2005-07-07 Time 14:58 Rev Time 0.00
Received By mmclean Date 2005-07-07 Time 14:58 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2005-05-06 Cont ID  
Sent By mmclean Date 2005-05-06 Time 18:30 Rev Time 0.00
Received By mmclean Date 2005-05-06 Time 18:29 Sent To I
Notes
2005-05-06 00:00:00DENIED,
 1. 2 COPY OF SURVEY WAS NOT SUBMITTED
 WITH PLANS.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720