| Plan Review Stops For Permit 05042228 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-08-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-22 |
Time |
14:13 |
Rev Time |
0.25 |
| Received By |
alange |
Date |
2005-08-22 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2005-08-22 00:00:00 | NEW SHUTTER SCHDL REC. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-07-21 |
Time |
08:58 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2005-07-21 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-05-23 |
Time |
07:19 |
Rev Time |
3.00 |
| Received By |
alange |
Date |
2005-05-23 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2005-05-23 00:00:00 | DENIED | | | | | | | | | 1. FBC* 104.6.5BUILDING PERMIT | | | VALUATION.THE STATED VALUE OF THE | | | PROJECT HAS BEEN UNDER-ESTIMATED AT | | | $185,220.THE VALUE, CALCULATED USING | | | THE SOUTHERN BUILDING CODE CONGRESS | | | INTERNATIONAL (SBCCI) VALUATION TABLES, | | | IS $268,860.THE PERMIT APPLICATION FEE | | | HAS BEEN ADJUSTED ACCORDINGLY, SO THERE | | | IS AN OUTSTANDING BALANCE OF $844.77. | | | THE REQUIRED AMOUNT SHALL BE PAID BEFORE | | | THE PLANS CAN BE RESUBMITTED. | | | | | | 2.SUBMIT 2 COPIES OF MANUFACTURERS | | | SPECS FOR BUILT-INBBQ. | | | | | | 3. FBC 1707.4.4.2SHOW BUCK DETAIL | | | COMPLYING WITH THIS SECTION.BUCK SHALL | | | HAVE FULL SUPPORT OF THE FRAME. | | | | | | 4. 1 OF A/7 FINISH GRADE FBC 1804.1.7 | | | WPB AMMENDMENTS FINISHED FLOOR SHALL BE | | | 4" ABOVE GRADE MINIMUM. | | | THE BOTTOM OF FOUNDATION SHALL EXTEND NO | | | LESS THAN 12" BELOW GRADE. FBC 1804.2.3 | | | THESE ARE BOTH MINIMUMS. THIS LEAVES NO | | | ROOM FOR ERROR OF THE FINISHED GRADE. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-14 |
Time |
13:33 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-03-14 |
Time |
13:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-01-31 |
Time |
21:44 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2006-01-31 |
Time |
21:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-11 |
Time |
11:27 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-07-11 |
Time |
10:45 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-10 |
Time |
09:00 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-10 |
Time |
08:33 |
Sent To |
M |
|
| Notes |
| 2005-05-10 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} INDICATE THE LOCATION OF PANEL "B". | | | | | | 2} INDICATE LOCATION OF OVERCURRENT | | | PROTECTION FOR PANELS "A" & "B". | | | | | | 3} THE OCP FOR CIRCUITS 12,13 PANEL "A", | | | 12,13,14,15 PANEL "B" IS TOO LARGE FOR | | | THE CONDUCTORS PER 210.16. | | | | | | 4} THE POWDER ROOM REQUIRES A GFI | | | RECEPTACLE PER 210.8(A) & 210.52(D). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-13 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-13 |
Time |
14:48 |
Sent To |
E |
|
| Notes |
| 2006-03-13 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-18 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-18 |
Time |
16:28 |
Sent To |
B |
|
| Notes |
| 2005-08-18 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-08 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-08 |
Time |
14:09 |
Sent To |
E |
|
| Notes |
| 2005-07-08 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-24 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-24 |
Time |
16:35 |
Sent To |
Z |
|
| Notes |
| 2005-06-24 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-09 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-09 |
Time |
10:51 |
Sent To |
E |
|
| Notes |
| 2005-05-09 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-05-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-05-23 |
Time |
07:19 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-04-29 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2005-04-29 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-07-19 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2005-07-19 |
Time |
17:25 |
Sent To |
B |
|
| Notes |
| 2005-07-19 00:00:00 | ENERGY CALCULATIONS AND MANUAL J | | | SUBMITTIED.NO PLANS | | | RJR |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-05-16 |
Time |
10:40 |
Rev Time |
0.75 |
| Received By |
prafter |
Date |
2005-05-16 |
Time |
10:40 |
Sent To |
P |
|
| Notes |
| 2005-05-16 00:00:00 | MECH.PLAN REVIEW: | | | | | | NO FL. ENERGY CALCULATIONS /A/C PLANS | | | OR EQUIPMENT INFORMATION. | | | COUSINS AIR INC. LISTED ON PERMIT APP. | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-18 |
Time |
09:36 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-07-18 |
Time |
09:36 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-05-17 |
Time |
18:48 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-05-17 |
Time |
18:48 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-07 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-07 |
Time |
14:58 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-05-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-05-06 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-05-06 |
Time |
18:29 |
Sent To |
I |
|
| Notes |
| 2005-05-06 00:00:00 | DENIED, | | | 1. 2 COPY OF SURVEY WAS NOT SUBMITTED | | | WITH PLANS. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|