Plan Review Details - Permit 05041961
| Plan Review Stops For Permit 05041961 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2006-02-24 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-02-24 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-02-24 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2006-02-24 00:00:00 | NEW ADDRESS HAS BEEN ASSIGNED : 427 | | | WILDER ST., PCN = 7443434409060002030 | | 2006-02-10 00:00:00 | ADDRESSES NOT PROPERLY ASSIGNED; BOTH | | | PARCELS HAVE AN ADDRESS OF 423 WILDER ST | | | IN PAPA AND OUR SYSTEM.ROUTED TO | | | ADDRESSING.SMH |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-04-26 |
|
|
Cont ID |
|
| Sent By |
dalvarez |
Date |
2005-04-26 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
dalvarez |
Date |
2005-04-26 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2005-04-26 00:00:00 | VERIFICATION OF ACTUAL ADDRESS & PCN | | | PARCEL WAS SUBDIVIDED DA |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-06-12 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-06-09 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 | | | RESIDENTIAL | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | ***PLAN CHECK ONLY*** | | | | | | GOVERNING CODE IS FBC2004 EFFECTIVE | | | OCTOBER 1, 2005.NO PERMIT WAS APPLIED | | | FOR PRIOR TO THIS DATE.REVISE ALL | | | INCORRECT CODE REFERENCES. | | | | | | COMMENTS FROM THE PREVIOUS REVIEWS; | | | NUMBERING TO REMAIN THE SAME FOR | | | CONSISTENCY.NOTE THAT CODE REFERENCE | | | NUMBERS HAVE CHANGED AS THE FIRST REVIEW | | | WAS DONE ON FBC2001, SECOND REVIEW ON | | | FBC2004. | | | | | | 1.) A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED, FS713.13. | | | | | | 2.) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY PRIOR TO PERMIT ISSUANCE. | | | THE PLANS MUST BE STAMPED AND THE | | | RECEIPT ATTACHED TO THE APPLICATION. | | | 561-233-5025 | | | | | | 3.-5.)ADDRESSED. | | | | | | 6.)ENERGY CALCS REQUIRED, FBC11-101.2. | | | SIGN THE OWNER/AGENT LINE OF THE ENERGY | | | CALC, FBC11-103.1.2. | | | | | | (2ND REVIEW) ENERGY CALCS WERE | | | SUBMITTED.THE | | | CEILING/FLOOR ASSEMBLY BETWEEN THE | | | UNCONDITIONED GARAGE AREA AND THE | | | CONDITIONED SECOND FLOOR IS NOT ON THE | | | ENERGY CALCS, FIRST PAGE.SECOND PAGE | | | SHOWS RAISED WOOD FLOOR ADJACENT, PLANS | | | SHOW CONCRETE FLOOR.THE PLAN DOES NOT | | | SHOW INSULATION BETWEEN THE LAUNDRY AREA | | | IN THE GARAGE AND THE UTILITY ROOM. | | | INSULATION IS SHOWN GRAPHICALLY ON A2.0 | | | BETWEEN FIRST AND SECOND FLOOR. | | | INSULATION SHOWN GRAPHICALLY BETWEEN | | | GARAGE AND ENTRY.PLEASE SPECIFY.THE | | | WOOD FRAME WALL IS NOT INCLUDED IN THE | | | ENERGY CALCS. | | | | | | (3RD REVIEW) ENERGY CALCS NO LONGER IN | | | THE PACKAGE.REQUIRED FOR PERMITTING. | | | | | | 7.)THE WIND RESISTANCE NOTES ON T1 | | | WERE PREPARED BY ANOTHER DESIGN | | | PROFESSIONAL, MAKES REFERENCE TO A | | | COMMERCIAL STRUCTURE, AND STATE THAT | | | THIS IS A PARTIALLY ENCLOSED BUILDING | | | WHICH IS NOT TO BE SHUTTERED.OTHER | | | SHEETS SPECIFY IMPACT GLASS.PLEASE | | | CLARIFY. | | | | | | (2ND REVIEW) SHEET T1 STILL STATES THAT | | | THIS IS A PARTIALLY ENCLOSED STRUCTURE. | | | SEE FBC1609.2. | | | | | | (3RD REVIEW) REFERS TO 1606; WIND | | | PROVISIONS ARE 1609.REVISE OR | | | ELIMINATE INCORRECT CODE REFERENCES. | | | ALSO ON A7.0. | | | | | | 8.-10.)ADDRESSED. | | | | | | 11.)LOCAL OR STATE PRODUCT APPROVAL | | | REQUIRED FOR: | | | SHINGLE OR METAL ROOF | | | WINDOWS | | | MULLIONS | | | FIXED GLASS WINDOWS | | | FRENCH DOORS | | | CASEMENT WINDOW | | | OVERHEAD DOOR | | | SKYLIGHTS | | | IMPACT PROTECTION IF REQUIRED | | | GARAGE DOOR | | | TEST REPORT AND INSTALLATION | | | INSTRUCTIONS REQUIRED IN ADDITION TO THE | | | FLORIDA OR LOCAL PRODUCT APPROVAL. | | | | | | SEPARATE PERMITS WILL BE REQUIRED FOR | | | ANY PRODUCT APPROVALS NOT PROPERLY | | | SUBMITTED AND REVIEWED PRIOR TO | | | ISSUANCE. | | | | | | (2ND REVIEW) NONE SUBMITTED.PRODUCT | | | APPROVALS TO BE REVIEWED BY DESIGNER OF | | | RECORD FBC*106.3.3. | | | | | | (3RD REVIEW) TWO COPIES REQUIRED OF ALL | | | DOCUMENTS.ONLY ONE ROOF PRODUCT | | | APPROVAL SUBMITTED. | | | | | | FIVE DIFFERENT TYPES OF WINDOWS ARE | | | SHOWN ON THE PLAN; ONLY ONE PRODUCT | | | APPROVAL SUBMITTED.PLANS NOT CLEAR, | | | SEE OTHER COMMENT REGARDING WINDOWS. | | | IMPACT S/H, IMPACT FIXED, IMPACT | | | CASEMENT, S/H, CASEMENT. | | | | | | THE PB COUNTY PRODUCT APPROVAL CHECKLIST | | | IS AN ACCEPTABLE METHOD OF SHOWING | | | COMPLIANCE WITH FBC*106.3.3, ARCHITECT | | | REVIEW.PROVIDE ORIGINAL SIGNATURES ON | | | THE FORM OR PROVIDE A REVIEW STAMP FOR | | | ALL PRODUCT APPROVALS.IF ADDING | | | PRODUCT APPROVALS, PLEASE REVISE THE | | | PRODUCT APPROVAL LIST. | | | | | | COMPLETE THE ATTACHED HURRICANE SHUTTER | | | INSTALLATION SCHEDULE, OR PROVIDE ALL | | | REQUIRED INFORMATION IN A SIMILAR | | | FORMAT. | | | | | | 12-13.)ADDRESSED. | | | | | | 14.) ADDRESSED. | | | | | | 15-16.)ADDRESSED. | | | | | | 17.)A7.0, PLYWOOD/GYPBOARD SHEATHING | | | NOTES, ITEM 2 (NAILING PATTERN 6IN | | | EDGES, 6IN FIELD) IS NON COMPLIANT, SEE | | | FBC*TABLE 2306.1.THE RESPONSE LETTER | | | STATES THAT THE SHEATHING NAILING WAS | | | CORRECTED TO 6IN OC EDGES AND 12IN OC | | | FIELD. | | | | | | (2ND REVIEW) NOT ADDRESSED.STILL | | | STATES 6/6.6/12 WAS SPECIFIED IN THE | | | RESPONSE LETTER. THIS IS ALSO NOT CODE | | | COMPLIANT.SEE FBC TABLE 2304.9.1. | | | | | | (3RD REVIEW) NOT ADDRESSED, PLANS STILL | | | SHOW 6/12.SUBFLOOR NAILING ALSO NOT | | | COMPLIANT WITH FBC TABLE 2304.9.1. | | | | | | 18.-19.)NOT ADDRESSED. | | | | | | 20.)WHAT IS THE CONSTRUCTION OF THE | | | CABANA WALLS?IT DOES NOT APPEAR TO BE | | | BLOCK.PROVIDE A DETAIL. | | | | | | 21.)PROVIDE A STRUCTURAL DETAIL FOR | | | THE BAY WINDOWS. | | | | | | (2ND REVIEW) NOT ADDRESSED.A CROSS | | | SECTION WAS PROVIDED SHOWING THE STAIR | | | AND BAY WINDOW.THIS IS NOT A | | | STRUCTURAL DETAIL AS SPACING, FASTENING, | | | DESIGN LOADS WERE NOT PROVIDED. | | | | | | (3RD REVIEW) NOT ADDRESSED.PROVIDE | | | DIMENSIONS, NONE SHOWN ON PLAN.SHOW | | | COMPLIANCE WITH FBC R302.1,302.2 (MUST | | | BE OVER 3' FROM PROPERTY LINE). | | | | | | 22-26.)ADDRESSED. | | | | | | 27.)SPECIFY INSULATION FOR THE | | | ADJACENT WALL (BETWEEN GARAGE AND ENTRY | | | HALL). | | | | | | (2ND REVIEW) NOT ADDRESSED.SHOWN | | | GRAPHICALLY BUT NOT SPECIFIED.ALSO | | | NEEDS INSULATION BETWEEN THE GARAGE AND | | | UTILITY ROOM. | | | | | | (3RD REVIEW) NOT ADDRESSED.THE FRAME | | | WALL WAS CHANGED TO BLOCK, STILL NEEDS | | | INSULATION.THE FRAME WALL SHOWS "SOUND | | | INSULATION", MUST HAVE R VALUE SPECIFIED | | | FBC13-602. | | | | | | 28.-32.)ADDRESSED. | | | | | | 31.)PROVIDE A STRUCTURAL DETAIL FOR | | | THE STAIRS, WITH ALL DIMENSIONS, | | | INCLUDING THE LANDING AND FIREBLOCKING | | | FBC2305.1.4(3). | | | | | | (2ND REVIEW) NOT ADDRESSED. | | | | | | (3RD REVIEW) NOT ADDRESSED. | | | | | | 32.)ADDRESSED. | | | | | | 33.)SAFETY GLASS REQUIRED AT TUBS AND | | | SHOWER, FBC2405.1. | | | | | | (2ND REVIEW) ADDRESSED IF IMPACT WINDOWS | | | ARE USED AS PER PLAN. | | | | | | (3RD REVIEW) UNSURE AS TO COMPLIANCE. | | | CONFLICTING NOTES REGARDING IMPACT | | | PROTECTION ON THE PLAN. | | | | | | 34.)THE CANTILEVERED BALCONY DETAIL A6 | | | DOES NOT HAVE A SLAB DIMENSION. | | | | | | (2ND & 3RD REVIEWS) NOT ADDRESSED. | | | | | | 35.)SPECIFY SOFFIT VENTING AND SHOW | | | COMPLIANCE FBC2309.7. | | | | | | (2ND & 3RD REVIEWS) NOT ADDRESSED. | | | | | | 36.)SPECIFY REACTION LOADS ON THE ROOF | | | FRAMING PLAN A7.0. | | | | | | NOT ADDRESSED. | | | | | | 37-39.) ADDRESSED. | | | | | | 40.) REINFORCEMENT ABOVE OPENINGS HAS | | | NOT BEEN SPECIFIED.PROVIDE A SCHEDULE. | | | | | | ADDRESSED BY STATING THAT LINTELS WILL | | | BE INSTALLED.SEE COMMENT 46 BELOW. | | | | | | PROVIDE A LINTEL SCHEDULE. | | | | | | 41.) A COPY OF THE PLANS HAS BEEN | | | RETAINED. | | | | | | ***NEW COMMENTS*** | | | | | | 42.)SHOW POSITIVE DRAINAGE FBC R401.3, | | | FBC*109.3.10. | | | | | | NOT ADDRESSED. | | | | | | 43.)ADDRESSED. | | | | | | 44.)ALL CHANGES TO THE PLAN ARE TO BE | | | CLEARLY INDICATED WITH A CLOUD AND | | | REVISION NUMBER.AS NONE OF THE CHANGES | | | WERE CLOUDED AND OLD SHEETS WERE NOT | | | SUBMITTED, THIS REQUIRED A COMPLETELY | | | NEW PLAN REVIEW.TO AVOID DELAYS, | | | CLEARLY INDICATE ALL CHANGES AND SUBMIT | | | OLD SHEETS AS IS STANDARD INDUSTRY | | | PRACTICE. | | | | | | 45.)ADDRESSED. | | | | | | 46.)PROVIDE INFORMATION IN REGARDS TO | | | THE BEAM ABOVE THE GARAGE DOOR.YOU | | | HAVE A 16? SPAN SUPPORTING CONCRETE | | | FLOOR JOISTS, A CONCRETE BALCONY AND A | | | CONCRETE BLOCK 2ND FLOOR WITH NO | | | STRUCTURAL INFORMATION AS TO HOW THIS | | | WILL BE ACCOMPLISHED.THERE IS A NOTE | | | STATING THAT LINTELS WILL GO OVER ALL | | | OPENINGS.PROVIDE MORE INFORMATION. | | | | | | (2ND REVIEW) BEAM HAS BEEN CHANGED TO | | | 8X20 W/2#6.PROVIDE CALCULATIONS; IT IS | | | NOT CLEAR HOW YOU ARE MAKING THESE | | | CHANGES TO ACCOMODATE THE 16' SPAN | | | SUPPORTING A SECOND STORY WHICH IS | | | BLOCK. | | | | | | 47.)PROVIDE A DETAIL FOR THE BEARING | | | WALL, INTERIOR NON BEARING WALLS, AND | | | THE CABANA WALL. | | | | | | NOT ADDRESSED. | | | | | | NEW COMMENTS, 3RD REVIEW: | | | | | | 48.)A7.0 REFERS TO ASCE7-98, CORRECT | | | REFERENCE IS ASCE7-02, FBC35. | | | | | | 49.)THE PLANS STATE THAT ALL WINDOWS | | | WILL BE IMPACT CASEMENT, SCHEDULE SHOWS | | | FIXED AND SINGLE HUNG, IMPACT 2ND | | | FLOOR,SHUTTERS 1ST FLOOR, AND SHUTTER | | | PRODUCT APPROVALS AND S/H NON IMPACT | | | WINDOW PRODUCT APPROVALS SUBMITTED. | | | ADDRESS. | | | | | | 50.)PROVIDE A SURVEY AND SOILS | | | INVESTIGATION REPORT FOR THIS JOB, TWO | | | ORIGINALS.I BELIEVE THAT THEY WERE IN | | | THE PACKAGE AT ONE TIME. | | | | | | 51.)THE ATTIC LIVE LOAD IS TO COMPLY | | | WITH FBC TABLE 1607.1 (MIN 10PSF ATTICS | | | WITHOUT STORAGE, 20 W/STORAGE). | | | | | | 52.)NOTE THAT THIS IS A PLAN CHECK | | | ONLY, PERMIT APPLICATION REQUIRED. | | | | | | 53.)PROVIDE ONE SET OF THE OLD PLANS | | | WHEN RESUBMITTING FOR REFERENCE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-02-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-02-10 |
Time |
15:48 |
Rev Time |
5.00 |
| Received By |
shill |
Date |
2006-02-09 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2006-02-10 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 | | | RESIDENTIAL | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | ***PLAN CHECK ONLY*** | | | | | | GOVERNING CODE IS FBC2004 EFFECTIVE | | | OCTOBER 1, 2005.NO PERMIT WAS APPLIED | | | FOR PRIOR TO THIS DATE.REVISE ALL | | | INCORRECT CODE REFERENCES. | | | | | | COMMENTS FROM THE PREVIOUS REVIEW; | | | NUMBERING TO REMAIN THE SAME FOR | | | CONSISTENCY.NOTE THAT CODE REFERENCE | | | NUMBERS HAVE CHANGED AS THE FIRST REVIEW | | | WAS DONE ON FBC2001, SECOND REVIEW ON | | | FBC2004. | | | | | | 1.) A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED, FS713.13. | | | | | | 2.) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY PRIOR TO PERMIT ISSUANCE. | | | THE PLANS MUST BE STAMPED AND THE | | | RECEIPT ATTACHED TO THE APPLICATION. | | | 561-233-5025 | | | | | | 3.)ADDRESSED. | | | | | | 4.)ADDRESSED. | | | | | | 5.)THE ARCHITECT FIRM IS TO HAVE A CA | | | NUMBER.TITLE BLOCK TO BE IN | | | CONFORMANCE WITH FAC61G1-16.003,004. | | | | | | NOT ADDRESSED.NO CA NUMBER PROVIDED | | | FOR FLORIDA KEY WEST DESIGN OR FLORIDA | | | DESIGN ARCHITECTS.A COPY OF THE TITLE | | | BLOCKS HAVE BEEN SENT TO THE ATTORNEY | | | FOR THE FLORIDA BOARD OF ARCHITECTS. | | | | | | 6.)ENERGY CALCS REQUIRED, FBC11-101.2. | | | SIGN THE OWNER/AGENT LINE OF THE ENERGY | | | CALC, FBC11-103.1.2. | | | | | | | | | ENERGY CALCS WERE SUBMITTED.THE | | | CEILING/FLOOR ASSEMBLY BETWEEN THE | | | UNCONDITIONED GARAGE AREA AND THE | | | CONDITIONED SECOND FLOOR IS NOT ON THE | | | ENERGY CALCS, FIRST PAGE.SECOND PAGE | | | SHOWS RAISED WOOD FLOOR ADJACENT, PLANS | | | SHOW CONCRETE FLOOR.THE PLAN DOES NOT | | | SHOW INSULATION BETWEEN THE LAUNDRY AREA | | | IN THE GARAGE AND THE UTILITY ROOM. | | | INSULATION IS SHOWN GRAPHICALLY ON A2.0 | | | BETWEEN FIRST AND SECOND FLOOR. | | | INSULATION SHOWN GRAPHICALLY BETWEEN | | | GARAGE AND ENTRY.PLEASE SPECIFY.THE | | | WOOD FRAME WALL IS NOT INCLUDED IN THE | | | ENERGY CALCS. | | | | | | 7.)THE WIND RESISTANCE NOTES ON T1 | | | WERE PREPARED BY ANOTHER DESIGN | | | PROFESSIONAL, MAKES REFERENCE TO A | | | COMMERCIAL STRUCTURE, AND STATE THAT | | | THIS IS A PARTIALLY ENCLOSED BUILDING | | | WHICH IS NOT TO BE SHUTTERED.OTHER | | | SHEETS SPECIFY IMPACT GLASS.PLEASE | | | CLARIFY. | | | | | | SHEET T1 STILL STATES THAT THIS IS A | | | PARTIALLY ENCLOSED STRUCTURE.SEE | | | FBC1609.2. | | | | | | 8.)ADDRESSED. | | | | | | 9.)ADDRESSED. | | | | | | 10.)ADDRESSED. | | | | | | 11.)LOCAL OR STATE PRODUCT APPROVAL | | | REQUIRED FOR: | | | SHINGLE OR METAL ROOF | | | WINDOWS | | | MULLIONS | | | FIXED GLASS WINDOWS | | | FRENCH DOORS | | | CASEMENT WINDOW | | | OVERHEAD DOOR | | | SKYLIGHTS | | | IMPACT PROTECTION IF REQUIRED | | | TEST REPORT AND INSTALLATION | | | INSTRUCTIONS REQUIRED IN ADDITION TO THE | | | FLORIDA OR LOCAL PRODUCT APPROVAL. | | | | | | SEPARATE PERMITS WILL BE REQUIRED FOR | | | ANY PRODUCT APPROVALS NOT PROPERLY | | | SUBMITTED AND REVIEWED PRIOR TO | | | ISSUANCE. | | | | | | NONE SUBMITTED.PRODUCT APPROVALS TO BE | | | REVIEWED BY DESIGNER OF RECORD | | | FBC*106.3.3. | | | | | | 12.)PLEASE READ FBC35 IN REGARDS TO | | | STANDARDS.YOU MAKE REFERENCE TO | | | ACI318-63 ON SHEET A3.(ALSO SPECIFIES | | | 300PSI CONCRETE.)THAT REFERENCE IS | | | VERY OUTDATED.CHECK ALL REFERENCES. | | | | | | NOT ADDRESSED.PLANS STILL STATE | | | ACI318-63.CHECK ALL REFERENCES. | | | | | | 13.)ADDRESSED. | | | | | | 14.)PROVIDE DESIGN CRITERIA REQUIRED | | | BY FBC1606.1.7.NO DESIGN PRESSURES FOR | | | ROOF OR COMPONENTS AND CLADDING WERE | | | PROVIDED. | | | | | | NOT ADDRESSED.WIND SPEED AND EXPOSURE | | | PROVIDED, NO COMPONENTS AND CLADDING | | | DESIGN PRESSURES AND PLANS STILL STATE | | | THAT THIS IS A PARTIALLY ENCLOSED | | | STRUCTURE. | | | | | | 15.)A7.0 SPECIFIES HUGHES CONNECTORS. | | | THEY HAVE BEEN OUT OF BUSINESS FOR MANY | | | YEARS.SPECIFY AVAILABLE, CODE | | | COMPLIANT PRODUCTS ONLY. | | | | | | SWITCHED TO SIMPSON, BUT I AM UNABLE TO | | | FIND TA STRAPS IN THE SIMPSON CATALOG. | | | | | | 16.)A7.0 MAKES REFERENCE TO BOCA 1996. | | | GOVERNING CODE IS FBC2001. | | | | | | NOT ADDRESSED.BOCA CODE REFERENCE | | | STILL ON THE PLAN.GOVERNING CODE IS | | | NOW FBC2004. | | | | | | 17.)A7.0, PLYWOOD/GYPBOARD SHEATHING | | | NOTES, ITEM 2 (NAILING PATTERN 6IN | | | EDGES, | | | 6IN FIELD) IS NON COMPLIANT, SEE | | | FBC*TABLE 2306.1.THE RESPONSE LETTER | | | STATES THAT THE SHEATHING NAILING WAS | | | CORRECTED TO 6IN OC EDGES AND 12IN OC | | | FIELD. | | | | | | NOT ADDRESSED.STILL STATES 6/6.6/12 | | | WAS SPECIFIED IN THE RESPONSE LETTER. | | | THIS IS ALSO NOT CODE COMPLIANT.SEE | | | FBC TABLE 2304.9.1. | | | | | | 18.)PROVIDE A WALL SECTION CONTINUOUS | | | FOUNDATION THROUGH ROOF, INCLUDING GRADE | | | IN RELATION TO FINISH FLOOR AND BOTTOM | | | OF FOOTER, FBC*104.3.1.1, FBC*1804.1.7. | | | | | | NOT ADDRESSED.NO INFORMATION GIVEN IN | | | REGARDS TO THE FIRST FLOOR BEAM. | | | | | | 19.)WATERSTOP REQUIRED FBC2111.1.9, | | | FIRST AND SECOND FLOOR. | | | | | | NOT ADDRESSED.THIS SHOULD BE SHOWN ON | | | THE WALL SECTION WHICH WAS NOT PROVIDED. | | | | | | 20.)WHAT IS THE CONSTRUCTION OF THE | | | CABANA WALLS?IT DOES NOT APPEAR TO BE | | | BLOCK.PROVIDE A DETAIL. | | | | | | 21.)PROVIDE A STRUCTURAL DETAIL FOR | | | THE BAY WINDOWS. | | | | | | NOT ADDRESSED.A CROSS SECTION WAS | | | PROVIDED SHOWING THE STAIR AND BAY | | | WINDOW.THIS IS NOT A STRUCTURAL DETAIL | | | AS SPACING, FASTENING, DESIGN LOADS WERE | | | NOT PROVIDED. | | | | | | 22.)ADDRESSED. | | | | | | 23.) PROVIDE CALCULATIONS FOR THE FILLED | | | CELLS SET AT EVERY 10FT. | | | | | | RESPONSE LETTER STATES THAT THEY WILL BE | | | EVERY 8FT, BUT THE NOTE ON A3 STATES | | | 10FT.2ND FLOOR, BEDROOM 3 HAS A | | | DISTANCE OF OVER 12FT. | | | | | | 24.)ADDRESSED. | | | | | | 25.)PROVIDE WINDOW AND DOOR BUCK | | | DETAILS. | | | | | | NOT ADDRESSED. | | | | | | 26.)ADDRESSED. | | | 26.)ADDRESSED. | | | | | | 27.)SPECIFY INSULATION FOR THE | | | ADJACENT WALL (BETWEEN GARAGE AND ENTRY | | | HALL). | | | | | | NOT ADDRESSED.SHOWN GRAPHICALLY BUT | | | NOT SPECIFIED.ALSO NEEDS INSULATION | | | BETWEEN THE GARAGE AND UTILITY ROOM. | | | | | | 28.)ADDRESSED. | | | | | | 29.)ADDRESSED. | | | | | | 30.)APPARENTLY ADDRESSED. | | | | | | 31.)ADDRESSED. | | | | | | 32.)DETAILS SHOWN ON A6.0 ARE NOT | | | CLEAR.COMPLETE DIMENSIONS AND | | | MATERIALS ARE NOT SHOWN. | | | | | | AS OLD SHEETS NOT SUBMITTED, UNSURE AS | | | TO WHAT THIS COMMENT REFERRED TO. | | | | | | 31.)PROVIDE A STRUCTURAL DETAIL FOR | | | THE STAIRS, WITH ALL DIMENSIONS, | | | INCLUDING THE LANDING AND FIREBLOCKING | | | FBC2305.1.4(3). | | | | | | NOT ADDRESSED. | | | | | | 32.)SHOW ATTIC ACCESS LOCATIONS AND | | | SIZE FBC2309. | | | | | | SPECIFY SIZE. | | | | | | 33.)SAFETY GLASS REQUIRED AT TUBS AND | | | SHOWER, FBC2405.1. | | | | | | ADDRESSED IF IMPACT WINDOWS ARE USED AS | | | PER PLAN. | | | | | | 34.)THE CANTILEVERED BALCONY DETAIL A6 | | | DOES NOT HAVE A SLAB DIMENSION. | | | | | | NOT ADDRESSED. | | | | | | 35.)SPECIFY SOFFIT VENTING AND SHOW | | | COMPLIANCE FBC2309.7. | | | | | | NOT ADDRESSED. | | | | | | 36.)SPECIFY REACTION LOADS ON THE ROOF | | | FRAMING PLAN A7.0. | | | | | | NOT ADDRESSED. | | | | | | 37.)PROVIDE CALCULATIONS FOR THE BOND | | | BEAM, ONE 8X8 WITH TWO #4S. | | | | | | NOT ADDRESSED.STILL SHOWS ONE 8X8 WITH | | | TWO #4S. | | | | | | 38.)PROVIDE DESIGN CRITERIA FOR | | | HANDRAILS AND GUARDRAILS, FBC1608.2, | | | FBC1007, FBC1015.STAIR DETAIL | | | DIFFICULT TO READ.THE RAILING CANNOT | | | BE 34", FBC1015, FBC1026.5. | | | | | | PROVIDE A DETAIL FOR THE RAILINGS.NOT | | | ADDRESSED. | | | | | | 39.)PROPERTY APPRAISER'S WEBSITE SHOW | | | TWO LOTS WITH THIS ADDRESS, EACH WITH A | | | STRUCTURE ON IT.PLEASE CLARIFY. | | | | | | THE PLANS SHOW TWO ADDRESSES.ADDRESS | | | ON THE PLAN IS TO BE ONE ADDRESS ONLY | | | WHICH SHOULD MATCH THE APPLICATION. | | | | | | 40.) REINFORCEMENT ABOVE OPENINGS HAS | | | NOT BEEN SPECIFIED.PROVIDE A SCHEDULE. | | | | | | ADDRESSED BY STATING THAT LINTELS WILL | | | BE INSTALLED.SEE COMMENT 46 BELOW. | | | | | | 41.) A COPY OF THE PLANS HAS BEEN | | | RETAINED. | | | | | | ***NEW COMMENTS*** | | | | | | 42.)SHOW POSITIVE DRAINAGE FBC R401.3, | | | FBC*109.3.10. | | | | | | 43.)PLANS SHOW AN ADDRESS OF 425 AND | | | 423 WILDER.APPLICATION IS FOR 423 | | | WILDER. | | | | | | 44.)ALL CHANGES TO THE PLAN ARE TO BE | | | CLEARLY INDICATED WITH A CLOUD AND | | | REVISION NUMBER.AS NONE OF THE CHANGES | | | WERE CLOUDED AND OLD SHEETS WERE NOT | | | SUBMITTED, THIS REQUIRED A COMPLETELY | | | NEW PLAN REVIEW.TO AVOID DELAYS, | | | CLEARLY INDICATE ALL CHANGES AND SUBMIT | | | OLD SHEETS AS IS STANDARD INDUSTRY | | | PRACTICE. | | | | | | 45.)A WOOD LOUVER IS SHOWN ON THE LEFT | | | SIDE ELEVATION, HAND WRITTEN ON THE | | | PLAN.PROVIDE A STRUCTURAL DETAIL AS TO | | | HOW THIS WILL BE BUILT AND COMPLY WITH | | | THE WIND PROVISIONS OF FBC16. | | | | | | 46.)PROVIDE INFORMATION IN REGARDS TO | | | THE BEAM ABOVE THE GARAGE DOOR.YOU | | | HAVE A 16? SPAN SUPPORTING CONCRETE | | | FLOOR JOISTS, A CONCRETE BALCONY AND A | | | CONCRETE BLOCK 2ND FLOOR WITH NO | | | STRUCTURAL INFORMATION AS TO HOW THIS | | | WILL BE ACCOMPLISHED.THERE IS A NOTE | | | STATING THAT LINTELS WILL GO OVER ALL | | | OPENINGS.PROVIDE MORE INFORMATION. | | | | | | 47.)PROVIDE A DETAIL FOR THE BEARING | | | WALL, INTERIOR NON BEARING WALLS, AND | | | THE CABANA WALL. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-05-25 |
Time |
14:12 |
Rev Time |
4.00 |
| Received By |
shill |
Date |
2005-05-24 |
Time |
17:11 |
Sent To |
PC |
|
| Notes |
| 2005-05-25 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.) A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED, FS713.13. | | | | | | 2.) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY PRIOR TO PERMIT ISSUANCE. | | | THE PLANS MUST BE STAMPED AND THE | | | RECEIPT ATTACHED TO THE APPLICATION. | | | 561-233-5025 | | | | | | 3.)PROVIDE A SURVEY FOR THIS PROPERTY. | | | | | | 4.)SOILS INVESTIGATION REPORT | | | REQUIRED. | | | | | | 5.)THE ARCHITECT FIRM IS TO HAVE A CA | | | NUMBER.TITLE BLOCK TO BE IN | | | CONFORMANCE WITH FAC61G1-16.003,004. | | | | | | 6.)ENERGY CALCS REQUIRED, FBC11-101.2. | | | SIGN THE OWNER/AGENT LINE OF THE ENERGY | | | CALC, FBC11-103.1.2. | | | | | | 7.)THE WIND RESISTANCE NOTES ON T1 | | | WERE PREPARED BY ANOTHER DESIGN | | | PROFESSIONAL, MAKES REFERENCE TO A | | | COMMERCIAL STRUCTURE, AND STATE THAT | | | THIS IS A PARTIALLY ENCLOSED BUILDING | | | WHICH IS NOT TO BE SHUTTERED.OTHER | | | SHEETS SPECIFY IMPACT GLASS.PLEASE | | | CLARIFY. | | | | | | 8.)SHOW THE BAY WINDOWS ON THE SITE | | | PLAN FOR ZONING REVIEW. | | | | | | 9.)INDICATE NORTH ON THE SITE PLAN AND | | | THE FLOOR PLAN. | | | | | | 10.)REGARDING THE MITERED GLASS, SEE | | | FBC2406 AND 1707.L.4.2, SHOW COMPLIANCE. | | | ALSO, LOCAL OR STATE PRODUCT APPROVAL | | | REQUIRED FAC9B72. | | | | | | 11.)LOCAL OR STATE PRODUCT APPROVAL | | | REQUIRED FOR: | | | SHINGLE OR METAL ROOF | | | WINDOWS | | | MULLIONS | | | FIXED GLASS WINDOWS | | | FRENCH DOORS | | | CASEMENT WINDOW | | | OVERHEAD DOOR | | | SKYLIGHTS | | | IMPACT PROTECTION IF REQUIRED | | | TEST REPORT AND INSTALLATION | | | INSTRUCTIONS REQUIRED IN ADDITION TO THE | | | FLORIDA OR LOCAL PRODUCT APPROVAL. | | | | | | SEPARATE PERMITS WILL BE REQUIRED FOR | | | ANY PRODUCT APPROVALS NOT PROPERLY | | | SUBMITTED AND REVIEWED PRIOR TO | | | ISSUANCE. | | | | | | 12.)PLEASE READ FBC35 IN REGARDS TO | | | STANDARDS.YOU MAKE REFERENCE TO | | | ACI318-63 ON SHEET A3.(ALSO SPECIFIES | | | 300PSI CONCRETE.) THAT REFERENCE IS VERY | | | OUTDATED.CHECK ALL REFERENCES. | | | | | | 13.)SHOW THE PLUMBING ON THE | | | FOUNDATION PLAN. | | | | | | 14.)PROVIDE DESIGN CRITERIA REQUIRED | | | BY FBC1606.1.7.NO DESIGN PRESSURES FOR | | | ROOF OR COMPONENTS AND CLADDING WERE | | | PROVIDED. | | | | | | 15.)A7.0 SPECIFIES HUGHES CONNECTORS. | | | THEY HAVE BEEN OUT OF BUSINESS FOR MANY | | | YEARS.SPECIFY AVAILABLE, CODE | | | COMPLIANT PRODUCTS ONLY. | | | | | | 16.)A7.0 MAKES REFERENCE TO BOCA 1996. | | | GOVERNING CODE IS FBC2001. | | | | | | 17.)A7.0, PLYWOOD/GYPBOARD SHEATHING | | | NOTES, ITEM 2 (NAILING PATTERN 6? EDGES, | | | 6? FIELD) IS NON COMPLIANT, SEE | | | FBC*TABLE 2306.1. | | | | | | 18.)PROVIDE A WALL SECTION CONTINUOUS | | | FOUNDATION THROUGH ROOF, INCLUDING GRADE | | | IN RELATION TO FINISH FLOOR AND BOTTOM | | | OF FOOTER, FBC*104.3.1.1, FBC*1804.1.7. | | | | | | 19.)WATERSTOP REQUIRED FBC2111.1.9, | | | FIRST AND SECOND FLOOR. | | | | | | 20.)WHAT IS THE CONSTRUCTION OF THE | | | CABANA WALLS?IT DOES NOT APPEAR TO BE | | | BLOCK.PROVIDE A DETAIL. | | | | | | 21.)PROVIDE A STRUCTURAL DETAIL FOR | | | THE BAY WINDOWS. | | | | | | 22.)PROVIDE CALCULATIONS TO JUSTIFY | | | THE 16X16 FOOTER WITH TWO #5S FOR THE | | | TWO STORY BLOCK STRUCTURE.A3, TYP CBS | | | EDGE DETAIL AND CONCRETE WORK ITEM 3 | | | SHOWS 16X16, PLAN STATES 16X24. | | | STRUCTURAL DETAILS SHOULD BE CONSISTENT. | | | | | | 23.) PROVIDE CALCULATIONS FOR THE FILLED | | | CELLS SET AT EVERY 10?. | | | | | | 24.)VERTICAL FILLED CELLS SHOWN AND | | | SPECIFIED ON ONE SIDE OF EACH OPENING | | | ONLY.WINDOW AND DOOR TEST REPORTS | | | GENERALLY HAVE A MINIMUM FASTENER | | | EMBEDMENT REQUIREMENT, HOW WILL THIS BE | | | ADDRESSED? | | | | | | 25.)PROVIDE WINDOW AND DOOR BUCK | | | DETAILS. | | | | | | 26.) A4.0 WALL BETWEEN GARAGE AND ENTRY | | | HALLWAY SHOWS A 6" CBS SOLID.WHAT DOES | | | THIS MEAN?PROVIDE A DETAIL. | | | | | | 27.)SPECIFY INSULATION FOR THE | | | ADJACENT WALL (BETWEEN GARAGE AND ENTRY | | | HALL). | | | | | | 28.)ADJACENT DOORS SHALL BE BE EITHER | | | SOLID CORE, INSULATED OR WOOD PANEL, | | | CANNOT BE HOLLOW CORE (DOOR 7). | | | | | | 29.)PROVIDE AREA CALCULATIONS ON THE | | | PLAN - AREAS UNDER AIR, 1ST AND 2ND | | | FLOORS, AND UNCONDITIONED SPACE. | | | | | | 30.)CASEMENT WINDOWS ARE SPECIFIED IN | | | THE WINDOW SCHEDULE, SINGLE HUNG ARE | | | SHOWN.THE MASONRY OPENING SIZES DO NOT | | | LEAVE ROOM FOR A WINDOW BUCK ON THE | | | SIDES. | | | | | | 31.)PROVIDE BEAM HEIGHTS ON THE PLAN. | | | | | | 32.)DETAILS SHOWN ON A6.0 ARE NOT | | | CLEAR.COMPLETE DIMENSIONS AND | | | MATERIALS ARE NOT SHOWN. | | | | | | 31.)PROVIDE A STRUCTURAL DETAIL FOR | | | THE STAIRS, WITH ALL DIMENSIONS, | | | INCLUDING THE LANDING AND FIREBLOCKING | | | FBC2305.1.4(3). | | | | | | 32.)SHOW ATTIC ACCESS LOCATIONS AND | | | SIZE FBC2309. | | | | | | 33.)SAFETY GLASS REQUIRED AT TUBS AND | | | SHOWER, FBC2405.1. | | | | | | 34.)THE CANTILEVERED BALCONY DETAIL A6 | | | DOES NOT HAVE A SLAB DIMENSION. | | | | | | 35.)SPECIFY SOFFIT VENTING AND SHOW | | | COMPLIANCE FBC2309.7. | | | | | | 36.)SPECIFY REACTION LOADS ON THE ROOF | | | FRAMING PLAN A7.0. | | | | | | 37.)PROVIDE CALCULATIONS FOR THE BOND | | | BEAM, ONE 8X8 WITH TWO #4S. | | | | | | 38.)PROVIDE DESIGN CRITERIA FOR | | | HANDRAILS AND GUARDRAILS, FBC1608.2, | | | FBC1007, FBC1015.STAIR DETAIL | | | DIFFICULT TO READ.THE RAILING CANNOT | | | BE 34", FBC1015, FBC1026.5. | | | | | | 39.)PROPERTY APPRAISER'S WEBSITE SHOW | | | TWO LOTS WITH THIS ADDRESS, EACH WITH A | | | STRUCTURE ON IT.PLEASE CLARIFY. | | | | | | 40.) REINFORCEMENT ABOVE OPENINGS HAS | | | NOT BEEN SPECIFIED.PROVIDE A SCHEDULE. | | | | | | 41.) A COPY OF THE PLANS HAS BEEN | | | RETAINED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-05-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-31 |
Time |
11:38 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-05-31 |
Time |
07:14 |
Sent To |
M |
|
| Notes |
| 2006-05-31 00:00:00 | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PER 110.9 AND 110.10: OBTAIN THE | | | AVAILABLE FAULT CURRENT AT THE UTILITY | | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | | INDICATE THE AIC RATING FOR THE | | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | | THE AVAILABLE FAULT. | | | | | | | | | 2} 250.6 OBJECTIONABLE CURRENT OVER | | | GROUNDING CONDUCTORS. | | | (A) ARRANGEMENT TO PREVENT OBJECTIONABLE | | | CURRENT. THE GROUNDING OF ELECTRICAL | | | SYSTEMS, CIRCUIT CONDUCTORS, SURGE | | | ARRESTERS, AND CONDUCTIVE | | | NON?CURRENT-CARRYING MATERIALS AND | | | EQUIPMENT SHALL BE INSTALLED AND | | | ARRANGED IN A MANNER THAT WILL PREVENT | | | OBJECTIONABLE CURRENT OVER THE GROUNDING | | | CONDUCTORS OR GROUNDING PATHS. | | | DISCONTINUE ONE OR MORE BUT NOT ALL OF | | | SUCH GROUNDING CONNECTIONS.PREFERABLY | | | AT PANEL "A". | | | | | | 3} 220.17 APPLIANCE LOAD DWELLING | | | UNIT(S). | | | IT SHALL BE PERMISSIBLE TO APPLY A | | | DEMAND FACTOR OF 75 PERCENT TO THE | | | NAMEPLATE RATING LOAD OF FOUR OR MORE | | | APPLIANCES FASTENED IN PLACE, OTHER THAN | | | ELECTRIC RANGES, CLOTHES DRYERS, | | | SPACE-HEATING EQUIPMENT, OR | | | AIR-CONDITIONING EQUIPMENT, THAT ARE | | | SERVED BY THE SAME FEEDER OR SERVICE IN | | | A ONE-FAMILY, TWO-FAMILY, OR MULTIFAMILY | | | DWELLING. RECALCULATE THE SERVICE LOAD | | | PER 220 PART II, OR OPTIONAL | | | CALCULATIONS PER 220 PART III. INDICATE | | | CALCULATION USED. | | | | | | 4} THE RANGE IS LISTED AT 8KW IN THE | | | CALC'S BUT AT 25 AMPS ON A 40 AMP | | | BREAKER ON THE SCHEDULE. | | | | | | 5} 11.8.3.5 NFPA-72 WHERE STAIRS LEAD TO | | | OTHER OCCUPIED LEVELS, A SMOKE ALARM OR | | | SMOKE DETECTOR SHALL BE LOCATED SO THAT | | | SMOKE RISING IN THE STAIRWAY CANNOT BE | | | PREVENTED FROM REACHING THE SMOKE ALARM | | | OR SMOKE DETECTOR BY AN INTERVENING DOOR | | | OR OBSTRUCTION.ADD ONE INSIDE THE STAIR | | | HALL. AFTER REVIEWING PREVIOUS NOTES, | | | IREALIZED THE ARTICLES FROM THAT REVIEW | | | WERE CURRENT. SEE NOTE #4, SAME INTENT, | | | DIFFERENT NUMBER. | | | | | | 6} SMOKE DETECTORS TARE REQUIRED TO BE | | | INTERCONNECTED PER R313.1 FBC, 11.8.2 | | | NFPA-72. PLEASE SUPPLY SPECIFICATIONS | | | INDICATING COMPLIANCE WITH THESE | | | ARTICLES WHILE THE DETECTORS ARE BEING | | | FED WITH MORE THAN ONE CIRCUIT. | | | | | | 7} PLEASE SEE 210.11(C)(3) BATHROOM | | | BRANCH CIRCUITS. IN ADDITION TO THE | | | NUMBER OF BRANCH CIRCUITS REQUIRED BY | | | OTHER PARTS OF THIS SECTION, AT LEAST | | | ONE 20-AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY THE BATHROOM | | | RECEPTACLE OUTLET(S). SUCH CIRCUITS | | | SHALL HAVE NO OTHER OUTLETS. | | | EXCEPTION: WHERE THE 20-AMPERE CIRCUIT | | | SUPPLIES A SINGLE BATHROOM, OUTLETS FOR | | | OTHER EQUIPMENT WITHIN THE SAME BATHROOM | | | SHALL BE PERMITTED TO BE SUPPLIED IN | | | ACCORDANCE WITH 210.23(A). ALL BATHS ARE | | | IN VIOLATION EXCEPT 35 AND 38. | | | | | | 8} 210.11(C)(1) SMALL-APPLIANCE BRANCH | | | CIRCUITS. IN ADDITION TO THE NUMBER OF | | | BRANCH CIRCUITS REQUIRED BY OTHER PARTS | | | OF THIS SECTION, TWO OR MORE 20-AMPERE | | | SMALL-APPLIANCE BRANCH CIRCUITS SHALL BE | | | PROVIDED FOR ALL RECEPTACLE OUTLETS | | | SPECIFIED BY 210.52(B). ONLY ONE | | | CIRCUIT, #34 APPEARS TO BE A "SMALL | | | APPLIANCE" CIRCUIT. IT SHOULD BE | | | DESIGNATED SUCH ON THE PANEL SCHEDULE, | | | ALONG WITH THE REQUIRED SECOND CIRCUIT. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-30 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-30 |
Time |
11:37 |
Sent To |
M |
|
| Notes |
| 2006-01-30 00:00:00 | *********** UNSAT2ND REVIEW ********* | | | | | | ** PLEASE SEE MANY NOTES FROM PREVIOUS | | | REVIEW WHICH STILL NEED TO BE ADDRESSED. | | | ** PLEASE ALSO SEE NEW NOTES DUE TO | | | CHANGES ON PLANS. | | | | | | | | | | | | ** PLEASE KNOW, PLANS HAVE ONLY BEEN | | | SUBMITTED FOR"PLAN REVIEW"AND NOT | | | FOR PERMIT. | | | PLEASE KNOW, AS OF OCT 1ST, 2005 THE FBC | | | HAS CHANGED TO THE 2004. PLANS MUST | | | CHANGE TO THE 2004 FBC WHEN SUBMITTED | | | FOR PERMIT. THIS WILL AFFECT MANY AREAS | | | OF PLANS. | | | PLEASE ALSO KNOW A NEW PERMIT PROCESSING | | | NUMBER MAY BE GIVEN. | | | | | | | | | | | | 1)NOTE: NOTE #1, NO, PLEASE SEE RESPONSE | | | LTR MENTIONS THIS WAS SUBMITTED, HOWEVER | | | THIS COULD NOT BE LOCATED ON PLANS. | | | | | | **PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 2) NOTE: NOTE #2 OK, HOWEVER PLEASE SEE | | | NOTE #12. | | | | | | | | | 3)NOTE: NOTE #3 NO, PLEASE SEE NEW | | | COMMENT FOR CIRCUITING ON PLANS. | | | PLEASE SEE THE REQUIRED DEDICATED BATH | | | CIRCUIT IS SHOWN ON WITH OTHER RECEPTS | | | ETC IN OTHER AREAS WHICH IS NOT | | | PERMITTED. | | | | | | ** PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | APPEAR TO BE SHOWN AS 20A'S HOWEVER NO | | | CONDUCTORS SIZES ARE SHOWN? | | | | | | 4)NOTE: NOTE #4 NO, PLEASE SEE MANY SD'S | | | WERE ADDED, HOWEVER PLEASE STILL SE | | | MISSING SD'S AS REDLINED. THESE MUST BE | | | INSIDE AND OUTSIDE ALL SLEEEPING RMS. | | | PLEASE ALSO SEE SD'S ARE REQUIRED TO BE | | | WIRED INLINEETC , HOWEVER PLEASE SEE | | | SD'S ARE BEING SHOWN TO AT LEAST 6 | | | SEPARATE CIRCUITS???? | | | | | | ** SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER: NFPA-72 11.5.1.1 | | | PLEASE SEE REDLINED PLANS, MANY ARE | | | MISSING. | | | | | | 5)NOTE: NOTE #5 NO, PLEASE SEE CWP IS | | | NOT SHOWN AS PART OF THE MAIN GROUNDING | | | ELETRODE SYSTEM AS REQUIRED PER 250.50, | | | 250.64C | | | | | | **PLEASE SHOW GROUNDING ELETRODE | | | SYSTEM PER 250.50. FOOTER STEEL/COLD | | | WATER/ ETC. SIZE ALL PER 250.66 | | | | | | 6)NOTE: NOTE #6 NO, PLEASE SEE REDLINED | | | PLANS FOR MISSING RECEPTS. | | | | | | ** PLEASE SHOW OUTLET SPACING PER | | | 210.52. 2',6`,12` RULE. | | | PLEASE SEE PLANS, THERE ARE NUMEROUS | | | MISSING. | | | PLEASE ALSO SEE "RAIL AREA" ON SECOND | | | FLR IS CONSIDERED WALL SPACE AND WILL | | | REQUIRED RECEPT(S). (FLR OUTLET) | | | | | | 7)NOTE: NOTE #7 OK. | | | | | | | | | 8)NOTE: NOTE #8 OK. | | | HOWEVER PLEASE SEE NEW COMMENT FOR POOL | | | PANEL. | | | | | | | | | 9)NOTE: NOTE #9 NO, PLEASE SEE THIS IS | | | STILL BEING SHOWN?? | | | | | | **PLEASE SEE 250.6,250.24, NO | | | EQUIPMENT GROUNDING SHALL BE INSTALLED | | | FROM METER TO MAIN. | | | | | | 10)NOTE: NOTE #10 NO, PLEASE SEE MISSING | | | IN HALL AS REDLINED ON PLANS. | | | | | | ** PLEASE 210.52H FOR MISSING | | | REQUIRED HALL RECEPTS. MORE THAN ONE | | | LOCATION. | | | | | | 11)NOTE: NOTE #11 NO, PLEASE SEE AREAS | | | WHERE ONLY A FAN IS BEING SHOWN FOR THE | | | MIN OF EITHER A SWITCHED RECEPT OR LIGHT | | | FIXTURE OF SOME SORT. | | | | | | **PLEASE SEE 210.70 FOR MISSING | | | EGRESS LIGHTING CONTROL(S) IN MORE THAN | | | ONE LOCATION. PLEASE ALSO SEE MISSING | | | LIGHTING FOR GRADE LEVEL ACCES STAIRS. | | | | | | 12)NOTE: NOTE #12 NO, PLEASE SEE MISSING | | | GFI RECEPT PENINSULAR. | | | | | | ** PLEASE SEE 210.52C-1-5 FOR | | | RECEPTS REQUIRED IN KITCHENS ALONG | | | COUNTERSPACES ETC. | | | | | | 13)NOTE: NOTE #13 OK. | | | | | | 14)NOTE: NOTE #14 OK. | | | | | | 15)NOTE: NOTE #15 OK. | | | | | | 16)NOTE: NOTE #16 OK. | | | | | | 17)NOTE: NOTE #17 OK. | | | | | | 18)NOTE: NOTE #18 NO, PLEASE SHOW | | | CALCUALTIONS PER NEC. | | | | | | ** PLEASE SEE NEC FOR LOAD | | | CALCULATIONS. | | | PLEASE SUBMIT LOAD CALCULATIONS BASED ON | | | MIN REQUIREMENTS UNDER 220.31 ETC. | | | | | | 19)NOTE: NOTE #19 OK, HOWEVER SEE NEW | | | NOTE FOR POOL PANEL. | | | | | | | | | 20)NOTE: NOTE #20, OK, HOWEVER PLEASE | | | SEE NEW NOTE FOR MIN LOAD. | | | | | | ** PLEASE SEE MISSING | | | LAUNDRY/WASHER CIRCUIT REQUIRED PER | | | 220.16, 210.11C2 | | | | | | 21)NOTE: NOTE #21 OK. | | | | | | 22)NOTE: NOTE #22 OK, WALL ADDED. | | | | | | | | | 23)NOTE: NOTE #23 NO, PLEASE SEE THIS | | | COMMENT IS THE SAME AS BEFORE. PLEASE | | | ALSO SEE NEW NOTES FOR SAID PLANS AND | | | SET BEING RETAINED FOR POSSIBLE REVIEW | | | BY THE STATE'S LEGAL COUNSEL. PLEASE SEE | | | BOTH COMPANIES AS SHOWN DOES SEEM TO BE | | | LICENSED AS REQUIRED AND NOTED ON | | | PREVIOUS REVIEW AS REQUIRED UNDER | | | FLORIDA STATUES. | | | PLANS ARE NOW SIGNED. | | | THIS COMMENT REMAINS FOR ALL TRADES AND | | | ALL REVIEWER(S) WHETHER OR NOT COMMENT | | | IS MADE BY OTHER(S). | | | | | | ** PLEASE SEE TITLE BLOCKS ARE | | | MISSING LICENSE INFORMATION AS REQUIRED | | | UNDER FAC 61G1-16.004 AND FS 481.219 | | | PLEASE ALSO SEE TITLE BLOCKS CHANGE FROM | | | PAGE TO PAGE WITH DIFFERENT COMPANY NAME | | | AND FIRMS SHOWN. | | | PLEASE SEE THIS COMMENT IS FOR ALL | | | TRADES AND FOR ALL SHEETS WHEATHER OR | | | NOT COMMENT IS MADE BY OTHER | | | REVIEWER(S). | | | | | | ** NEW NOTES** | | | | | | 1)NOTE: PLEASE CORRELAT EFLOORS WITH | | | OTHER SHEETS. PLEASE SEE THE FIRST FLOOR | | | IS NOTED AS THE "2ND FLR" THIS FLR | | | CONTAINS THE GARAGE, POOL ETC. | | | PLEASE ALSO ADJUST 2ND FLR, AS IT IS | | | SHOWN AS FIRST FLR. | | | | | | 2)NOTE: PLEASE SEE ITEM(S) IN LOAD | | | CALCUALTIONS AND NOT ON SCHEDULE OR | | | PLANS. | | | PLEASE SEE JACUZZI, ? PLEASE ALSO SEE | | | 680.71 FOR GFI PROTECTION REQUIRED TO BE | | | INDICATED. | | | | | | 3)NOTE: PLEASE SEE WASHER IS NOW LISTED, | | | HOWEVER THE MIN KW RATING FOR | | | WASHER/LAUNDRY CIRCUIT IS 1.5 KW. | | | 220.16 | | | | | | 4)NOTE: PLEASE CORRELATE ALL CIRCUITING | | | ON PLANS WITH PANEL SCHEDULE. | | | PLEASE SEE SMALL APPLIANCE CIRCUITS | | | SHOWN WITH RECEPTS OUTSIDE, BATHS ETC. | | | PLEASE SEE BATHS CIRCUITS SHOWN ON | | | OTHERS AS PREVIOUSLY NOTED. | | | PLEASE SEE SOME CIRCUIT(S) MISSING, | | | PLEASE SEE SD'S ETC ETC. | | | 215.5 | | | MANY OF THESE ARE REDLINED ON PLANS. | | | | | | 5)NOTE: PLEASE REMOVE POOL PANEL OR | | | LABLE AS "FUTURE". PLEASE KNOW, IF POOL | | | IS PERMITTED DURING CONSTRUCTION OF MAIN | | | HOUSE , THE PLANS WILL BE REQUIRED TO BE | | | REVISED TO INCLUDE THIS. | | | 215.5 | | | | | | 6)NOTE: PLEASE SEE FLORIDA STATUES | | | SECTION 553.80(2)(B) WITH RESPECT TO | | | DESIGN PROFESSIONAL AND CODE COMPLIANT | | | COMMENTS THREE OR MORE TIMES AND | | | POSSIBLE 4X FEE ACCESSED TO DESIGN | | | PROFESSIONALS. PLEASE KNOW THIS IS GIVEN | | | ONLY A NOTICE ON THIS REVIEW. | | | ** PLEASE KNOW, ONE SET OF PLANS ARE | | | BEING RETAINED FOR FILE AS MENTIONED | | | ABOVE. | | | | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | PLEASE SEE DUE TO THE AMOUNT OF COMMENTS | | | ,CODE CORRECTIONS NEEDED, AND MISSING | | | INFORMATION FURTHER COMMENTS MAY BE | | | POSSIBLE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-03 |
Time |
14:28 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-05-03 |
Time |
14:05 |
Sent To |
M |
|
| Notes |
| 2005-05-03 00:00:00 | ************* UNSAT ****************** | | | | | | PLANS SUBMITTED FOR "PLAN REVIEW ONLY | | | AND NOT SUBMITTED FOR PERMIT. | | | REVIEW FOR A NEW SFR. | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 2) NOTE: PLEASE SHOW ALL RECEPTS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED PER 210.8A-6 | | | | | | 3)NOTE: PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | APPEAR TO BE SHOWN AS 20A'S HOWEVER NO | | | CONDUCTORS SIZES ARE SHOWN? | | | | | | 4)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | PLEASE SEE REDLINED PLANS, MANY ARE | | | MISSING. | | | | | | 5)NOTE: PLEASE SHOW GROUNDING ELETRODE | | | SYSTEM PER 250.50. FOOTER STEEL/COLD | | | WATER/ ETC. SIZE ALL PER 250.66 | | | | | | 6)NOTE: PLEASE SHOW OUTLET SPACING PER | | | 210.52. 2',6`,12` RULE. | | | PLEASE SEE PLANS, THERE ARE NUMEROUS | | | MISSING. | | | PLEASE ALSO SEE "RAIL AREA" ON SECOND | | | FLR IS CONSIDERED WALL SPACE AND WILL | | | REQUIRED RECEPT(S). (FLR OUTLET) | | | | | | 7)NOTE: PLEASE SEE MISSING RECEPT REQ'D | | | FOR A/C EQUIPMENT. 210.63 | | | | | | 8)NOTE: PLEASE CORRELATE RISER DIGRAM(S | | | WITH PANEL SCHEDULE(S) AND PLANS. | | | PLANS INDICATE MULTIPLE PANELS A&B AND | | | MSB. PLEASE SEE NO PANEL SCHEDULE | | | SUBMITTED FOR PANEL "C". PLEASE SEE | | | THERE ARE NUMEROUS ITEMS THAT DO NOT | | | CORRELATE SERVICE AND PLANS. | | | | | | 9)NOTE: PLEASE SEE 250.6,250.24, NO | | | EQUIPMENT GROUNDING SHALL BE INSTALLED | | | FROM METER TO MAIN. | | | | | | 10)NOTE: PLEASE 210.52H FOR MISSING | | | REQUIRED HALL RECEPTS. MORE THAN ONE | | | LOCATION. | | | | | | 11)NOTE: PLEASE SEE 210.70 FOR MISSING | | | EGRESS LIGHTING CONTROL(S) IN MORE THAN | | | ONE LOCATION. PLEASE ALSO SEE MISSING | | | LIGHTING FOR GRADE LEVEL ACCES STAIRS. | | | | | | 12)NOTE: PLEASE SEE 210.52C-1-5 FOR | | | RECEPTS REQUIRED IN KITCHENS ALONG | | | COUNTERSPACES ETC. | | | | | | 13)NOTE: PLEASE SHOW ALL OUTSIDE, GARAGE | | | RECEPTS ETC AS GFI/ GFI PROTECTED. | | | 210.8B3 | | | | | | 14)NOTE: PLEASE SEE MISSING ISCONNECTS | | | FOR A/C EQUIPMENT.440.11 | | | | | | 15)NOTE: PLEASE CORRELATE LOAD | | | CALCAULTIONS AND PANEL SCHEDULES FOR A/C | | | EQUIPMENT. SHOWN AT 5KW. 7.5 KW, 10 KW | | | ?? | | | ETC ETC. | | | | | | 16)NOTE: PLEASE INCLUDE ALL CONDUCTOR | | | SIZES ON PANEL SCHEDULES AND CORRELATE | | | WITH THE OCP SHOWN. | | | 310.16,240.4 | | | | | | 17)NOTE: PLEASE SEE 210.11C1 FOR MISSING | | | REQUIRED SMALL APPLIANCE CIRCUITS. | | | PLEASE SEE LOAD CALCS INDICATE TWO, | | | HOWEVERONE SHOWN AT 1.5KW AND THE | | | OTHER AT 1.2? PLEASE SEE MIN OF 1.5KW IS | | | REQUIRED PER 220.16, 210.11C1 PLEASE | | | ALSO SEE PANEL SCHEDULES DO NOT INDICATE | | | SMALL APPLIANCE CIRCUITS?? | | | | | | 18)NOTE: PLEASE SEE NEC FOR LOAD | | | CALCULATIONS. | | | PLEASE SUBMIT LOAD CALCULATIONS BASED ON | | | MIN REQUIREMENTS UNDER 220.31 ETC. | | | | | | 19)NOTE: PLEASE SEE POOL HEATER MAY NOT | | | BE DERATED AT 65% AS THIS LOAD IS A | | | CONTINUOUS LOAD (3 OR MORE) HOURS AND | | | MUST BE SHOWN AT 125% ALONG WITH LARGEST | | | MPTORS LOADS. POOL PUMP IS ALSO 125% FOR | | | A CONT LOAD.215.3, 230.42 ETC. | | | | | | 20)NOTE: PLEASE SEE MISSING | | | LAUNDRY/WASHER CIRCUIT REQUIRED PER | | | 220.16, 210.11C2 | | | | | | 21)NOTE: PLEASE SEE THERE ARE THREE A/C | | | SYSTEMS SHOWN ON PANEL SCHEDULE, | | | HOWEVER, LOAD CALCS ONLY SHOWN 2??? | | | PLEASE CORRELATE. | | | 215.5 | | | | | | 22)NOTE: PLEASE SEE 110.26 FOR MIN | | | CLEARENCES REQUIRED FOR A/C, AHU DISC'S. | | | PLEASE ALSO SEE OCP IS NOT PERMITTED IN | | | CLOTHES/ STORAGE CLOSETS.240.24D ETC | | | | | | 23)NOTE: PLEASE SEE TITLE BLOCKS ARE | | | MISSING LICENSE INFORMATION AS REQUIRED | | | UNDER FAC 61G1-16.004 AND FS 481.219 | | | PLEASE ALSO SEE TITLE BLOCKS CHANGE FROM | | | PAGE TO PAGE WITH DIFFERENT COMPANY NAME | | | AND FIRMS SHOWN. | | | PLEASE SEE PLANS ALSO APPEAR TO BE | | | "SIGNED" WITH INITIALS WHICH ARE NOT | | | ACCEPTABLE. IF INDEED THIS IS THE "LEGAL | | | SIGNATURE" OF ARCH, PLEASE SUBMIT A | | | SIGNED, DATED SEALED AND NOTORTIZED | | | LETTER STATING LEGAL SIGNATURE. | | | FS 481.221 | | | PLEASE SEE THIS COMMENT IS FOR ALL | | | TRADES AND FOR ALL SHEETS WHEATHER OR | | | NOT COMMENT IS MADE BY OTHER | | | REVIEWER(S). | | | | | | PLEASE SEE DUE TO THE AMOUNT OF COMMENTS | | | ,CODE CORRECTIONS NEEDED, AND MISSING | | | INFORMATION FURTHER COMMENTS MAY BE | | | POSSIBLE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-05-18 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-18 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
N |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-05-18 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-18 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-26 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-26 |
Time |
11:11 |
Sent To |
E |
|
| Notes |
| 2006-05-26 00:00:00 | TO "E" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-15 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-15 |
Time |
14:07 |
Sent To |
Z |
|
| Notes |
| 2006-05-15 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-01-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-28 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-28 |
Time |
15:46 |
Sent To |
E |
|
| Notes |
| 2006-01-28 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-01-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-10 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-10 |
Time |
14:26 |
Sent To |
Z |
|
| Notes |
| 2006-01-10 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-03 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-03 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
| 2005-05-03 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-04-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-25 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-04-28 |
Time |
10:39 |
Sent To |
Z |
|
| Notes |
| 2005-04-28 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-06-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-07 |
Time |
10:34 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-06-07 |
Time |
10:34 |
Sent To |
B |
|
| Notes |
| 2006-06-07 00:00:00 | *** DENIED *** | | | 1) RETURN AIR DUCTS TO FIRST FLOOR ROOMS | | | OFFICE, STAIR HALL, GUEST ROOM, AND | | | IN-LAW BEDROOM ARE NOT SIZED OR SIZED TO | | | SMALL, SEE NOTE #5. | | | | | | 2) PLEASE SHOW OR EXPLAIN HOW RETURN AIR | | | DUCTS ARE TO TIE INTO THE OPEN RETURN IN | | | THE A/C CLOSET ( LOUV. DOOR R/A AND | | | DUCTED RETURN AIR). | | | | | | 3) PLEASE SUBMIT ENERGY CALCULATIONS | | | FORM 600A-04 (2004) PER FBC 13-600.3.A . | | | | | | 4) PLEASE SUBMITMANUAL J CALCULATIONS, | | | PER 2004 FBC 13-607.1.ABC.1 . | | | | | | 5)BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-31 |
Time |
11:25 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-01-31 |
Time |
11:25 |
Sent To |
P |
|
| Notes |
| 2006-01-31 00:00:00 | *** DENIED *** | | | 1) MACHANICAL PLAN (DUCT LAY-OUT) IS | | | DIFFICULT TO READ DUE TO SIZE. | | | CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY. PER 2004 FBC 106.1.1 | | | | | | 2) NO RETURN AIR PROVIDED FOR. BALANCED | | | RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | 4) WHEN APPLYING FOR PERMIT PLANS WILL | | | NEED TO COMPLY WITH 2004 BUILDING CODES, | | | AND ENERGY CALCULATIONS WILL NEEN TO BE | | | ON FORM 600A-2004. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-05-18 |
Time |
09:05 |
Rev Time |
0.75 |
| Received By |
prafter |
Date |
2005-05-18 |
Time |
09:05 |
Sent To |
FIRE |
|
| Notes |
| 2005-05-18 00:00:00 | MECH. PLAN REVIEW: | | | | | | 1. NO A/C EQUIPMENT INFORMATION. | | | | | | 2. NO ENERGY CALCULATIONS FOR BUILDING. | | | | | | 3. A/C SYSTEM MUST ADHEAR TO BALANCED | | | R/A 2003 FBC/M 601.4 . | | | | | | 4. A/C AHU MUST ADHEAR TO 2003 FBC/M | | | 307.2.3 FOR AUX. DRAIN PANS . | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-06-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-06 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-06 |
Time |
17:03 |
Sent To |
M |
|
| Notes |
| 2006-06-06 00:00:00 | DENIED; | | | SANITARY RISER DIAGRAM NOT TO CODE; | | | TOO MANY CODE VIOLATIONS TO LIST. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-31 |
Time |
14:46 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2006-01-31 |
Time |
14:46 |
Sent To |
B |
|
| Notes |
| 2006-01-31 00:00:00 | DENIED; | | | 1. FBC-2004 TO BE USED. | | | 2.THE 1/2 BATHROOMS ON 1 ST FLOOR DO NOT | | | APPEAR TO HAVE THE CLEARANCES REQUIRED | | | BY FBC-2004 PLUMBING SEC.405.3.1. | | | 3.SANIRARY RISER DIAGRAM, SIZE ALL | | | PIPES, VENTING VIOLATIONS, FIXTURES MISS | | | NAMED, DOES NOT FOLLOW FLOOR PLAN. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-05-03 |
Time |
15:39 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-05-03 |
Time |
15:39 |
Sent To |
M |
|
| Notes |
| 2005-05-03 00:00:00 | PLUMBING FIXTURES MAY NOT HAVE REQUIRED | | | CLEARANCES. SEE FBC 2001 PLUMBING SEC. | | | 405.3.1. | | | PLUMBING RISER IS NOT READABLE PLEASE | | | RE-DO.BEFORE RESUBING FOR PERMIT | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-05-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-24 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-24 |
Time |
10:29 |
Sent To |
I |
|
| Notes |
| 2006-05-24 00:00:00 | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/SECK. | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/WALL/GATE WITH EASEMENT APPROVAL | | | FROM THE CITY OF WEST PALM BEACH UTILITY | | | DEPT. | | | | | | NOTE: MUST MAINTAIN 1000SQ FT OR 75% | | | WHICHEVER IS LESS WITHIN THE FIRST 25FT | | | FRONT SETBACK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-27 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-26 |
Time |
18:42 |
Sent To |
I |
|
| Notes |
| 2006-01-26 00:00:00 | DENIED. | | | 1. TOO MUCH CONCRETE WITHIN THE FRONT | | | SETBACK OF PROPERTY. CAN ONLY 312.5SQ FT | | | OF CONCRETE WITHIN THE FRONT SETBACK. | | | | | | NOTE: MUST MAINTAIN | | | 2. THE FRONT PORCH MUST BE 25FT WITHIN | | | THE FRONT SETBACK. ROOF CAN ONLY PROJECT | | | 3FT INTO THE 25FT FRONT SETBACK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-04-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-03 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-04-29 |
Time |
10:43 |
Sent To |
I |
|
| Notes |
| 2005-04-29 00:00:00 | DENIED, | | | 1. MUST PROVIDE TWO COPY OF SURVEYS | | | SHOWING THE HOUSE WITH SETBACKS. | | | 2. TOO MUCH CONCRETE WITHIN THE FRONT | | | SETBACK 25FT. | | | NOTE: MUST MEET THE ZONING REQUIRMENTS | | | OF 1000SQ OR 75% OF LANDSCAPE WITHIN THE | | | FRONT SETBACK (25FT) | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
|