Plan Review Details - Permit 05041807
| Plan Review Stops For Permit 05041807 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-05-18 |
Time |
11:18 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-05-18 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-06-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-22 |
Time |
12:42 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-06-22 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2005-06-22 00:00:00 | ********** PROVISO/REVISION REQ'D ***** | | | | | | PLEASE SEE NOW THAT CIRCUITING IS SHOWN | | | ON PLANS AND PANEL SCHEDULE IS | | | SUBMITTED, PLEASE SEE THE FOLLOWING CODE | | | COMMENTS FOR CORRECTION NEEDED. | | | | | | 1)NOTE: PLEASE SEE ALL SD'S WHICH ARE | | | REQUIRED TO BE WIRED "INLINE" ARE ALL | | | SHOWN ON SEPARATE CIRCUITS??? THIS IS | | | NOT POSSIBLE . PLEASE ADJUST CIRCUITING, | | | ALL SD'S ON SAME CIRCUIT AND THIS | | | CIRCUIT SHALL BE ARC FAULT PROTECTED. | | | SD'S MAY BE PLACED ON ONE OF THE BEDRM | | | CIRCUITS. | | | NFPA-72 8-1.4.1.6.2, 210.12 | | | | | | 2)NOTE: PLEASE SEE CIRCUITING REQ'D FOR | | | "DINING RM". PLEASE SEE DIN RM RECEPTS | | | ARE SHOWN ON WITH LIV RM CIRCUITS. | | | 210.52B1 | | | | | | 3)NOTE: PLEASE SEE GFI RECEPT PLACEMENT | | | FOR WHAT APPEARS TO BE A KITCHEN | | | PENINSULAR IS TO BE VERIFIED AND SHOWN | | | TO MEET 210.52C3,5 | | | | | | PLEASE MAKE THE ABOVE CORRECTIONS AND | | | SUBMIT REVISED PLANS BEFORE ROUGH | | | ELECTRICAL INSPECTION IS CALLED IN. | | | | | | PLEASE NOTE: IF PLANS COME BACK WITH AMY | | | OTHER CORRECTIONS NEEDED BEFORE PERMIT | | | IS ISSUED, PLEASE MAKE CORRECTIONS AT | | | THATTIME. THIS WILL ALSO ALLEVIATE A | | | REVSION FEE AT A LATER DATE. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-03 |
Time |
13:45 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-05-03 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2005-05-03 00:00:00 | ** UNSAT **' | | | | | | 1)NOTE: PLEASE SHOW CIRCUITING ON PLANS | | | AND CORRELATE WITH A PANEL SCHEDULE TO | | | BE SUBMITTED. | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE SWITCHES SHOWN AND | | | NOTED TO SW OUTLETS, HOWEVER THESE ARE | | | NOTE SHOWN? PLEASE SHOW. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE ALL NEW CIRCUTING TO | | | BEDRMS SHALL HAVE ARC FAULT PROTECTION | | | AS REQUIRED UNDER 2002 NEC 210.12. | | | THIS WOULD INCLUDE , RECEPTS, LTS, FANS, | | | SD'S. | | | | | | 4)NOTE: PLEASE SEE 210.52D,210.11C3 FOR | | | IN 20A #12FOR BATH(S) CIRCUIT(S). | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
N |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-05-10 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-10 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2005-05-10 00:00:00 | 1) THERE DOESN'T APPEAR TO BE ANYTHING | | | THAT WILL EFFECT LIFE SAFETY IN THE | | | SCOPE OF THIS WORK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-08 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-08 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2005-06-15 00:00:00 | WAITING FOR COMM BOARD | | | | | | COMM BOARD 38 | | 2005-06-08 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-26 |
Time |
18:23 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-05-02 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2005-05-02 00:00:00 | TO "COMM" BD#7 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-30 |
Time |
13:29 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-06-30 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-26 |
Time |
18:15 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-05-26 |
Time |
18:15 |
Sent To |
|
|
| Notes |
| 2005-05-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1. SUBMIT SANITARY RISER DIAGRAM TO SHOW | | | CHANGES IN LOCATION FOR TUB, SHOWER, AND | | | KITCHEN SINK. SHOW ALL PIPE SIZES, | | | VENTING, AND LOCATION OF CONNECTION FOR | | | EACH FIXTURES MOVED. SECTION 104.3.1.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
|