| Plan Review Stops For Permit 05041760 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-13 |
|
|
Cont ID |
|
| Sent By |
jhiggins |
Date |
2005-06-13 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-03-27 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2005-06-13 00:00:00 | ADDRESS 465 W EXECUTIVE CENTER DR | | | ASSIGNED TOPARCEL ON 2/17/05. JTH. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
40 |
Status |
P |
Date |
2007-12-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-12-21 |
Time |
16:11 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-12-21 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2007-12-21 16:12:25 | REVISED ENERGY CALCULATIONS 11/13/07 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
39 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2007-11-13 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2007-11-13 16:24:18 | 11-13-07 SKYLINE FABRICATORS SHEET M-6 - OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
38 |
Status |
P |
Date |
2007-11-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-13 |
Time |
14:23 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-11-13 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2007-11-13 14:24:41 | SHOP DRAWINGS SKYLINE STEEL FABRICATORS SHEET M-6 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
37 |
Status |
P |
Date |
2007-11-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-09 |
Time |
16:04 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2007-11-09 |
Time |
16:04 |
Sent To |
PC |
|
| Notes |
| 2007-11-09 16:05:03 | REVISION# 5, A-6.1 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
36 |
Status |
P |
Date |
2007-09-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-30 |
Time |
16:08 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2007-09-30 |
Time |
16:08 |
Sent To |
PC |
|
| Notes |
| 2007-09-30 16:22:07 | BUILDING PLAN REVIEW | | | PERMIT: 05041760 | | | ADD: 465 W EXECUTIVE CTR DR | | | CONT: THE WEITZ CO | | | TEL: (561)719-0102 | | | FL BLD CODE= 20041FLORIDA BUILDING CODE | | | WEST PALM BEACH AMENDMENTS | | | | | | 4TH REVISIONREVIEW | | | ACTION: REVIEWED | | | 1) SHEET # A-0.2, A-0.3, A-0.4, | | | A-1.0, A-1.1, A-1.2, A-1.3, A-1.5, | | | A-3.0, A-3.1, A-4.0, A-4.1, A-5.0, A-5.1, | | | A-6.0, A-6.2, A-7.0, A-7.2, | | | A-8.1, A-8.2, A-8.3 & A-10.1 | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
35 |
Status |
F |
Date |
2007-09-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-30 |
Time |
08:25 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2007-09-30 |
Time |
08:23 |
Sent To |
PC |
|
| Notes |
| 2007-09-30 08:27:22 | BUILDING PLAN REVIEW | | | PERMIT: 05041760 | | | ADD: 465 W EXECUTIVE CENTER DR | | | CONT: THE WEITZ CO | | | TEL: (561)719-0102 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISION# 4REVIEW | | | SHEET: A-6.1 | | | ACTION: DENIED | | | | | | SHEET A-6.1,DEETAIL 12 | | | | | | 1)THE HANDICAPPED SUITE KITHEN AREA, THE SINK BASE | | | CABINET INDICATES A 2'-3" WIDTH IN THE OPENING. | | | SINKS:11-4.24.2 SINKS, HEIGHT. SINKS SHALL BE | | | MOUNTED WITH THE COUNTER NO HIGHER THAN 34" ABOVE THE | | | FINISH FLOOR. | | | 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH | | | 30" WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH | | | SINKS. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE | | | APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
34 |
Status |
F |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-14 |
Time |
16:42 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-09-14 |
Time |
16:42 |
Sent To |
PC |
|
| Notes |
| 2007-09-14 16:46:09 | BUILDING PLAN REVIEW | | | PERMIT: 05041760 | | | ADD: 465 W EXECUTIVE CENTER DR | | | CONT: THE WEITZ CO | | | TEL: (561)719-0102 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | W/ * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)PLEASE PROVIDE THE FLORIDA COVERSHEETS THAT TIE TO | | | THESE REPORTS. NOTE THESE REPORTS ARE TO BE UNDER THE | | | 2001 FBC. | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
33 |
Status |
P |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-14 |
Time |
16:34 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2007-09-14 |
Time |
16:34 |
Sent To |
PC |
|
| Notes |
| 2007-09-14 16:40:20 | SUBMITTALS: | | | FIRESTOPPING FOR BUNDLED CABLES | | | W-J3082 CABLES THROUGH MASONRY | | | W-L3195 CABLES THROUGH DRYWALL | | | C-AJ-3030 CABLES THROUGH MASONARY WITH SLEEVES | | | ENGINEERING JUDGEMENT CAJ-3030 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
31 |
Status |
P |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-01 |
Time |
12:45 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2007-08-01 |
Time |
12:45 |
Sent To |
PC |
|
| Notes |
| 2007-08-01 12:46:43 | REVISIONS TO THE CANOPY STEEL FRAMING. | | | CALCULATIONS TO RAILING POST AND STAINLESS STEEL | | | EXTENSION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
30 |
Status |
F |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-01 |
Time |
12:39 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2007-08-01 |
Time |
12:39 |
Sent To |
PC |
|
| Notes |
| 2007-08-01 12:43:51 | BUILDING PLAN REVIEW | | | PERMIT: 05041760 | | | ADD: 465 W EXECUTIVE CTR DR | | | CONT: THE WEITZ CO | | | TEL: (561)719-0102 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | SHOP DRAWING HANDRAILREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)11-4.13.6 MANEUVERING CLEARENCES AT DOORS. | | | MINIMUM MANEUVERING CLEARANCES AT DOORS THAT ARE NOT | | | AUTOMATIC OR POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH IN THE REQUIRED | | | CLEARANCES SHALL BE CLEAR & LEVEL. | | | | | | 3) THE RAISED DECK DOES NOT HAVE EDGE PROTECTION A | | | WHEELCHAIR'S WHEEL COULD DROP BETWEEN THE DECK AND | | | GAURDRAIL. 11-4.8.7 EDGE PROTECTION. | | | RAMPS AND LANDINGS WITH DROP-OFFS SHALL HAVE CURBS, | | | WALLS, RAILINGS, OR PROJECTING SURFACES THAT PREVENT | | | PEOPLE FROM SLIPPING OFF THE RAMP. CURBS SHALL BE A | | | MINIMUM OF 2 INCHES (50 MM) HIGH (SEE FIGURE 17 ). | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
29 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-07-06 |
Time |
16:32 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-07-06 |
Time |
16:32 |
Sent To |
B |
|
| Notes |
| 2007-07-06 16:35:58 | BUILDING PLAN REVIEW | | | PERMIT:05041760 | | | ADD: 465 W EXECUTIVE CENTER DR | | | CONT: THE WEITZ CO | | | TEL: (561)719-0102 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) THE NOA'S SUBMITTED WERE NOT REVIEWED BY THE DESIGN | | | PROFESSIONAL. WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
28 |
Status |
P |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-07-06 |
Time |
14:28 |
Rev Time |
1.77 |
| Received By |
jwitmer |
Date |
2007-07-06 |
Time |
14:28 |
Sent To |
PC |
|
| Notes |
| 2007-07-06 15:33:24 | SUBMITTALS: SKYLINE STEEL SHOP DRAWINGS REVISIONS M-Z & | | | M-3 | | | OVERHEAD ROLLING GRILLE FOR GIFT SHOP | | | STRUCTURAL FRAMING SHOPS | | | STEEL LADDER & ROOF HATCH | | | FIRESTOPPING SUBMITTALS | | | SKETCH 19-20 REPAIR IN STAIRWAY# 1 RELOCATION OF DOOR | | | 100C TO THE SOUTH SIDE OF STAIRWELL. | | | BIO FIRESHIELD LECTRA STOP | | | CURRIES FL5773/2004 | | | ARCH ALUMINUM ALUMINUM OUTSWING DOOR NOA 04-1208.01 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
27 |
Status |
P |
Date |
2007-05-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-05-10 |
Time |
08:45 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-05-10 |
Time |
08:45 |
Sent To |
PC |
|
| Notes |
| 2007-05-10 08:46:01 | METAL PAN STAIR SHOP DRAWINGS-OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
26 |
Status |
P |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-05-07 |
Time |
09:58 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2007-05-07 |
Time |
09:58 |
Sent To |
PC |
|
| Notes |
| 2007-05-07 09:59:35 | SSKYLINE STEEL SHOPS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
25 |
Status |
P |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-05-07 |
Time |
09:50 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2007-05-07 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2007-05-07 09:53:04 | FILIGRREE PRECAST SLAB ROOF SHORING LETTER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
24 |
Status |
P |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-05-07 |
Time |
09:50 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2007-05-07 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2007-05-07 09:52:04 | POURED IN PLACE BEAM & SHORING ROOF LETTERES SKETCHES | | 2007-05-07 09:50:08 | FILIGREE PRECAST SLAB, ROOF SHORING LETTER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
23 |
Status |
F |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-05-07 |
Time |
09:15 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-05-07 |
Time |
09:15 |
Sent To |
PC |
|
| Notes |
| 2007-05-07 09:23:37 | BUILDING PLAN REVIEW | | | PERMIT: 05041760 | | | ADD: 465 W. EXECUTIVE CENTER DR | | | CONT: THE WEITZ CO | | | TEL: (561)719-0102 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | * WEST PALM BEACH AMENDMENTS | | | | | | STAIR SHOP DRAWINGREVIEW | | | | | | ACTION: DENIED | | | | | | 1) 1007.3.1 RISERS SHALL BE A MAXIMUM HEIGHT OF 7 IN. | | | (17.8 CM) AND A | | | MINIMUM HEIGHT OF 4 IN. (10.2 CM). TREADS SHALL BE A | | | MINIMUM OF 11 IN. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
22 |
Status |
P |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-03-19 |
Time |
13:40 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-03-19 |
Time |
13:40 |
Sent To |
PC |
|
| Notes |
| 2007-03-19 15:50:36 | 3-19-07 SUBMITTALS REVIEWED | | | | | | 1)STRUCTURAL STUD FRAMING, EXTERIOR | | | 2) 6TH FLOOR BEAM AND POURED IN PLACE SLAB SHORING | | | LETTERS & SKETCHES | | | 3) FILIGREE PRECAST SLAB SHORING LETTERS | | | 4) LAUNDRY CHUTE SHOP DRAWINGS | | | 5)SUBMITTALS SHOP DRAWINGS FOR WINDOWS, TRANSOMS & | | | STOREFRONT DOORS | | | 6)BESAM AUTOMATIC SLIDING DOOR | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
21 |
Status |
P |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-03-01 |
Time |
13:16 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-03-01 |
Time |
13:16 |
Sent To |
PC |
|
| Notes |
| 2007-03-01 13:17:40 | 5TH FLOOR BEAM SHORING INSPECTION LETTER | | | 5TH FLOOR FILIGREE SHORING INSPECTION LETTER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
20 |
Status |
P |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-03-01 |
Time |
12:21 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2007-03-01 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2007-03-01 12:21:55 | DAILY REPORTS 70-74 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
19 |
Status |
N |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-02-20 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2007-02-20 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2007-02-20 09:01:42 | DAILY REPORTS 63-69 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
18 |
Status |
F |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-02-20 |
Time |
08:46 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-02-20 |
Time |
08:46 |
Sent To |
PC |
|
| Notes |
| 2007-02-20 08:50:13 | BUILDING PLAN REVIEW | | | PERMIT: 05041760 | | | ADD: 465 W EXECUTIVE CTR | | | CONT: THE WEITZ CO | | | TEL: (561)719-0102 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | LAUNDRY CHUTEREVIEW | | | ACTION: DENIED | | | | | | 1) DOCUMENTS SUBMITTED, TWO SETS, THIS IS A THRESHOLD | | | BUILDING REQUIRING THREE SETS OF ALL DOCUMENTS | | | SUBMITTED. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
17 |
Status |
P |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-01-25 |
Time |
09:30 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2007-01-25 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2007-01-25 09:31:17 | 4TH FLOOR BEAM SHORING LETTER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
16 |
Status |
P |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-01-25 |
Time |
09:27 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-01-25 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2007-01-25 09:28:40 | 4TH FLOOR PRE-CAST SLAB SHORING- FILIGREE- OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
F |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-01-25 |
Time |
07:11 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2007-01-25 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2007-01-25 07:14:34 | | | | | | | | | | | | | | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 05041760 | | | ADD: 465 W EXECUTIVE CTR DR | | | CONT: THE WEITZ CO | | | TEL: (561)719-0102 | | | | | | | | | 2001 FBC=2001 FLORIDA BUILDING CODE | | | *= W. P. B. AMENDMENTS | | | | | | REVISION: REFUSE CHUTE | | | REVIEW | | | ACTION: DENIED | | | | | | 1) FBC 104.2.1ALL INFORMATION, | | | DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME | | | AND SIGNATURE OF THE PERSON RESPONSIBLE | | | FOR THE DESIGN.PLEASE COMPLY. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 2007-01-02 13:29:41 | 3RD FLOOR DECK FILIGREE PRECAST SLAB INSPECTION LETTER | | | 3RD FLOOR BEAM SHORING INSPECTION LETTER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
N |
Date |
2006-12-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-12-14 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2006-12-14 08:47:49 | DAILY INSPECTION REPORTS 27-29 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
N |
Date |
2006-12-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-12-04 |
Time |
13:06 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-12-04 |
Time |
13:06 |
Sent To |
PC |
|
| Notes |
| 2006-12-04 13:07:59 | PRECAST SLAB LETTER | | | PRE-CAST SLAB SHORING SHOP DRAWINGS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
N |
Date |
2006-12-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-12-04 |
Time |
12:58 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-12-04 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2006-12-04 12:58:40 | DAILY INSPECTION REPORTS 16- 26. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
N |
Date |
2006-11-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-11-15 |
Time |
08:19 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-11-15 |
Time |
08:19 |
Sent To |
PC |
|
| Notes |
| 2006-11-15 08:20:32 | 11-15-06 | | | 1) DRY- IN PLAN | | | 2) BEAM SHORING PLAN | | | 3) INSPECTION REPORTS 7-16 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
N |
Date |
2006-10-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-10-30 |
Time |
08:34 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2006-10-30 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2006-10-30 08:36:40 | 2 SUBMITTALS: | | | 1) WELDERS QUALIFICATION RECORD | | | 2) BEARING CAPACITY CERTIFICATION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
N |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-10-25 |
Time |
09:39 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2006-10-25 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2006-10-25 09:40:32 | HAWTHORNE SUITES DAILY INSPECTION REPORTS 1-6. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
N |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-10-17 |
Time |
16:52 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2006-10-17 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-10-17 |
Time |
16:43 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-10-17 |
Time |
16:43 |
Sent To |
PC |
|
| Notes |
| 2006-10-17 16:44:55 | STRUCTURAL STEEL SHOP DRAWINGS JOIST SKYLINE STEEL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
N |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-08-03 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2006-08-03 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2006-08-03 00:00:00 | THRESHOLD INSPECTION PLAN: SLIDER | | | ENGINEERING GROUP | | | PAUL BARBIERI P.E. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
N |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-08-03 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2006-08-03 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2006-08-03 00:00:00 | RECEIVED SPECIAL INSPECTOR AGREEMENT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-08-03 |
Time |
14:02 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2006-08-03 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2006-08-03 00:00:00 | | | | PERMIT: 05041760 | | | ADD: 465 W. EXECUTIVE CENTER DR. | | | (74-43-43-20-00-000-3010) | | | CONT: THE WEITZ CO. | | | TEL: (561)686-5511 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | ---ISSUED PERMIT--- | | | | | | | | | BUILDING PROVISO: | | | | | | | | | 1) PLEASE SUBMIT PRODUCT APPROVAL & FL | | | COVERSHEET FOR 6'-0"X7'-0"OUTSWING | | | COMMERCIAL STEEL DOORS LOCATED IN ZONE # | | | 5 BEFORE DOOR AND WINDOW BUCK | | | INSPECTION. DESIGN PRESURE FOR 6'-4"X | | | 7'-0" OPENING IS -68.3. | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-04-12 |
Time |
10:48 |
Rev Time |
5.55 |
| Received By |
jwitmer |
Date |
2006-04-12 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2006-04-12 00:00:00 | PERMIT: 05041760 | | | ADD: XXX W. EXECUTIVE CENTER DR. | | | (74-43-43-20-00-000-3010) | | | CONT: THE WEITZ CO. | | | TEL: (561)686-5511 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1)COMMENT# 3 FROM THE PREVIOUS REVIEW, | | | COMPLIED.THRESHOLD INSPECTION REPORT. | | | | | | 2) COMMENT# 5 FROM THE PREVIOUS REVIEW, | | | DEALS WITH IMPACT FEES ONLY 1 SET | | | STAMPED MINIMUM 2 SETS REQUIRE SSTAMP, | | | AND THERE ISN'T ANY COUNTY RECEIPT IN | | | PACKAGE INDICATING PAYMENT.BEFORE A | | | PERMIT TO CONSTRUCT CAN BE ISSUED, | | | IMPACT FEES MUST BE PAID TO PALM BEACH | | | CO.,THE PERMIT PLANS STAMPED BY THEM AND | | | THE RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. | | | | | | 3A) COMMENTS 6& 7 FROM THE PREVIOUS | | | REVIEW, DEALS WITH ACCESSIBILITY, FAIR | | | HOUSING. ONLY 1 SEET OF PLANS APPROVED | | | BY PLANNING, 3 ARE REQUIRED. | | | 3B) THE SIDEWALK FROM THE RIGHT-OF-WAY | | | TO THE ENTRY, PLANS DO NOT INDICATE CURB | | | CUTS, NOR IS THE CROSS WALK FROM POOL TO | | | HOTEL ENTRY SHOW CROSS HATCHING. | | | 3C) HANDICAPPED PARKING WITH ACCESS | | | AISLES, NO DETAILS TRANSITION FROM | | | ACCESS AISLE TO SIDEWALK? | | | 3D) PLANS DO NOT INDICATE ACCESS TO | | | DROP OFF ZONE IN FRONT OF HOTEL. | | | | | | 4) COMMENT# 11 FROM THE PREVIOUS REVIEW | | | DEALS WITH CURRIES EXTERIOR DOORS | | | MISSING REPORT FOR DOUBLE DOORS | | | (6'-0"X7'-0") LOCATED IN END ZONE(5). | | | PRESSURES 38.6/-68.3. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-02 |
Time |
09:39 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2005-12-02 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2005-12-02 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05041760 | | | ADD: XXX W. EXECUTIVE CENTER DR. | | | (74-43-43-20-00-000-3010) | | | CONT: THE WEITZ CO. | | | TEL: (561)686-5511 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) COMMENT# 2FROM THE PREVIOUS REVIEW, | | | PERMIT APPLICATION CORRECT THE PCN TO | | | (74-43-43-20-00-000-3010) OR PROVIDE | | | ADDITIONAL INFORMATION.THE CITY GIS | | | SYSTEM ONLY INDICATES A SINGLE LOT SEE | | | ATTACHED PAGES. OWNER AS COURTNEY LAKES | | | APARTMENTS LLC. PALM BEACH COUNTY | | | PROPERTY APPRAISERS OFFICE INDICATES | | | THIS SINGLE LOT HAS BEEN REPLATED INTO | | | (5) LOTS. THE CITY HAS NOT RECEIVED A | | | COPY OF THE REPLAT TO UPDATE OUR LAND | | | FILE AND TO ADDRESS THE NEWLY FORMED | | | LOTS. PROVIDE A COPY OF THE RECORDED | | | REPLAT!!!!! | | | | | | 2) COMMENT# 3 FROM THE PREVIOUS REVIEW | | | SEE ATTACHMENT,LOW VALUE, CALCULATED | | | VALUE IS: $9,907,170.00 SEE ADDITIONAL | | | FEES. | | | | | | 3) COMMENT# 5 FROM THE PREVIOUS | | | REVIEWDEALS WWITH THE THRESHOLD | | | INSPECTOR FORMS TO BE FILLED OUT,WPB | | | AMENDMENT 105.13.6. W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A | | | SPECIAL INSPECTOR AS REQUIRED BY S. | | | 553.79(5) FLORIDA STATUTES TO THE MIN- | | | IMUM INSPECTIONS REQUIRED BY THIS CODE. | | | CONTACT HAROLD PISKURA MANAGER OF THE | | | SPECIAL INSPECTOR PROGRAM AT (561) | | | 805-6711 FOR FURTHER INFORMATION BEFORE | | | THE PERMIT MAY BE ISSUED. | | | | | | 4) COMMENT# 7FROM THE PEVIOUS REVIW, | | | 903.8.2 FLOR ST STATUTE 553.895(2) | | | ALL RESIDENTIAL BUILD. 3 OR MORE STORIES | | | TALL WHETHER DESIGNATED AS TOWNHOUSE, | | | CONDOMINIUMS, "APARTMENT HOUSES, | | | TENEMENTS, GARDEN APARTMENTS OR BY ANY | | | OTHER NAME SHALL BE SUPPLIED BY FIRE | | | SPRINKLERS MEETING NFPA 101. SINCE THE | | | FIRE SPRINKLERS ARE REQUIRED BY CODE | | | THEY MUST BE PART OF THE PERMIT PACKAGE. | | | | | | 5)COMMENT# 10 FROM THE PREVIOUS REVIEW, | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 6) COMMENT# 3A) FROM THE PREVIOUS REVIEW | | | | | | DEALS WITH CROSSWALKS FOR ACCESSIBLE | | | ROUTES, PLEASE INDICATE WHERE THE | | | ACCESSIBLE ROUTE IS ON EITHER C-2 OR | | | C-3, ALSO INDICATE FLARED CURBING FOR | | | SIDEWALKS.11-4.1.2(1) AT LEAST ONE | | | ACCESSIBLE ROUTE COMPLYING WITH ?11-4.3 | | | SHALL BE PROVIDED WITHIN THE BOUNDARY OF | | | THE SITE FROM PUBLIC TRANSPORTATION | | | STOPS, ACCESSIBLE PARKING SPACES, | | | PASSENGER LOADING ZONES IF PROVIDED, AND | | | PUBLIC STREETS OR SIDEWALKS, TO AN | | | ACCESSIBLE BUILDING ENTRANCE. | | | | | | 7) PLANS INDICATE THE ACCESSIBLE PARKING | | | | | | COMMENT# 14 FROM THE PREVIOUS REVIEW, | | | | | | THE ACCESSIBLE PARKING SPACES ARE TO BE | | | ON THE SHORTEST ROUTE OF TRAVEL. | | | 11-4.6.2 LOCATION. ACCESSIBLE PARKING | | | SPACES SERVING A PARTICULAR | | | BUILDING SHALL BE LOCATED ON THE | | | SHORTEST SAFELY ACCESSIBLE ROUTE OF | | | TRAVEL FROM ADJACENT PARKING TO AN | | | ACCESSIBLE ENTRANCE.IN PARKING | | | FACILITIES THAT DO NOT SERVE A | | | PARTICULAR BUILDING, ACCESSIBLE PARKING | | | SHALL BE LOCATED ON THE SHORTEST | | | ACCESSIBLE ROUTE OF TRAVEL TO AN | | | ACCESSIBLE PEDESTRIAN ENTRANCE OF THE | | | PARKING FACILITY.IN BUILDINGS WITH | | | MULTIPLE ACCESSIBLE ENTRANCES WITH | | | ADJACENT PARKING, ACCESSIBLE PARKING | | | SPACES SHALL BE DISPERSED AND LOCATED | | | CLOSEST TO THE ACCESSIBLE ENTRANCES. | | | | | | 8) COMMENT# 18 FROM THE PREVIOUS REVIEW | | | INDICATE COMPLIANCE WITH 11-9.1.4(1) FOR | | | SUITE TYPE "C".18) 11-9.1.4(1) IN | | | ORDER TO PROVIDE PERSONS WITH | | | DISABILITIES A RANGE OF OPTIONS | | | EQUIVALENT TO THOSE AVAILABLE TO OTHER | | | PERSONS SERVED BY THE FACILITY, SLEEPING | | | ROOMS AND SUITES REQUIRED TO BE | | | ACCESSIBLE BY11-9.1.2 SHALL BE | | | DISPERSED AMONG THE VARIOUS CLASSES OF | | | SLEEPINGACCOMMODATIONS AVAILABLE TO | | | PATRONS OF THE PLACE OF TRANSIENT | | | LODGING.FACTORS TO BE CONSIDERED | | | INCLUDE ROOM SIZE, COST, AMENITIES | | | PROVIDED, & THE NUMBER OF BEDS PROVIDED. | | | | | | 9) COMMENT FROM# 24 FROM THE PREVIOUS | | | REVIEW, THERE SEEMS TO BE CONFUSION ON | | | THE LAUNDRY& REFUSE CHUTE ON LOCATION | | | SEE A-1.2 & A-1.3 . | | | | | | 10) COMMENT # 26 FROM THE PREVIOUS | | | REVIEW, MISSING RATING ON DOORS LEADING | | | TO REFUSE & LAUNDRY ROOMS A 3/4HR | | | RATING.705.2.4.3 REFUSE AND LAUNDRY | | | CHUTE ACCESS ROOMS.ACCESS OPENINGS | | | FOR REFUSE AND LAUNDRY CHUTES SHALL BE | | | LOCATED IN ROOMS OR COMPARTMENTS | | | COMPLETELY ENCLOSED BY CONSTRUCTION AND | | | OPENING PROTECTIVES IN ACCORDANCE WITH | | | TABLE 705.1.2.ACCESS OPENINGS TO | | | REFUSE AND LAUNDRY CHUTES SHALL NOT BE | | | LOCATED IN EXIT ACCESS CORRIDORS OR EXIT | | | ENCLOSURES. | | | | | | 11) COMMENT# 40 FROM THE PREVIOUS REVIEW | | | DEALS WITH CURRIES EXTERIOR DOORS IN END | | | ZONE# 5, REPORT GOOD FOR +/- 62 REQUIRES | | | A -68.3. | | | | | | 12) COMMENT# 41 FROM THE PREVIOUS REVIEW | | | | | | DEALS WITH RESAM AES AUTO DOORS, ARCH | | | PLANS A4.1 SECTION# 1 INDICATES A NEW | | | STEEL MULLION NOT DEPICTED ON STRUCRURAL | | | PLANS. 1707.4.5.2 MULLIONS SHALL BE | | | DESIGNED TO TRANSFER THE DESIGN PRESSURE | | | LOADS APPLIED BY THE WINDOW OR DOOR | | | ASSEMBLIES TO THE ROUGH OPENING | | | SUBTRATE. INDICATE COMPLIANCE. | | | | | | 13) A-3.0 WINDOW SCHEDULE INDICATES A | | | WINDOW TYPE "A" BUT DOESN'T INDICATE IF | | | THIS IS A HORIZONTAL SLIDER OR FIXED? | | | IF THE WINDOWS ARE SLIDERS THE REPORT | | | WAS TESTED WITH A 63" WINDOW WHEREAS THE | | | PLANS CALL FOR A 65" WINDOW. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-08 |
Time |
14:38 |
Rev Time |
12.00 |
| Received By |
jwitmer |
Date |
2005-06-08 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2005-06-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05041760 | | | ADD: XXX W. EXECUTIVE CENTER DR. | | | (74-43-43-20-00-000-3010) | | | CONT: THE WEITZ CO. | | | TEL: (561)686-5511 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) ADDRESS TO BE DETERMINED BY CITY MIS | | | DEPARTMENT, JOHN HIGGINS 822-1239. | | | | | | 2) PERMIT APPLICATION CORRECT THE PCN TO | | | (74-43-43-20-00-000-3010) OR PROVIDE | | | ADDITIONAL INFORMATION. | | | | | | 3) LOW VALUE, CALCULATED VALUE IS: | | | $9,907,170.00 SEE ADDITIONAL FEES. | | | | | | 4) FL S. S. 553.71(7) " THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN | | | HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPAN | | | CY CLASSIFICATION AS DEINED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS | | | 5,000 SQ FT IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | 105.13.1 THE ENFORCING AGENCY SHALL | | | REQUIRE A SPECIAL INSPECTOR TO PERFORM | | | SRUCTURAL INSPECTIONS ON A THRESHOLD | | | BUILDING PURSUANT TO A STRUCTURAL INSPEC | | | TION PLAN PREPARED BY THE ENGINEER OF | | | RECORD. THE STRUCTURAL INSPECTION PLAN | | | MUST BE SUBMITTED TO THE ENFORCING AGEN- | | | CY PRIOR TO THE ISSUANCE OF A BUILDING | | | PERMIT FOR THE CONSTRUCTION OF A THRESH- | | | OLD BUILDING. THE PURPOSE OF THE SRUCTUR | | | AL INSPECTION PLAN IS TO PROVIDE SPECIF- | | | IC INSPECTION PROCEDURES AND SCHEDULES | | | SO THAT THE BUILDING CAN BE ADEQUATELY | | | INSPECTED FOR COMPLIANCE WITH THE | | | PERMITTED DOCUMENTS. | | | S-7 SHORING NOTES, SHORING TO BE SET | | | BY CONTRACTOR BUT THE THRESHOLD | | | INSPECTOR TO SIGN OFF FOR APPROVAL. | | | | | | 5) WPB AMENDMENT 105.13.6. W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A | | | SPECIAL INSPECTOR AS REQUIRED BY S. | | | 553.79(5) FLORIDA STATUTES TO THE MIN- | | | IMUM INSPECTIONS REQUIRED BY THIS CODE. | | | CONTACT HAROLD PISKURA MANAGER OF THE | | | SPECIAL INSPECTOR PROGRAM AT (561) | | | 805-6711 FOR FURTHER INFORMATION BEFORE | | | THE PERMIT MAY BE ISSUED. | | | | | | 6) W.P.B. AMENDMENT 105.13.4.4 ALL PLANS | | | FOR THE BUILDING WHICH ARE REQUIRED TO | | | BE SIGNED AND SEALED BY THE ARCHITECT OR | | | ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S OR | | | ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS | | | DETERMINED BY THE LOCAL AUTHORITY IN | | | ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 7) 903.8.2 FLOR ST STATUTE 553.895(2) | | | ALL RESIDENTIAL BUILD. 3 OR MORE STORIES | | | TALL WHETHER DESIGNATED AS TOWNHOUSE, | | | CONDOMINIUMS, "APARTMENT HOUSES, | | | TENEMENTS, GARDEN APARTMENTS OR BY ANY | | | OTHER NAME SHALL BE SUPPLIED BY FIRE | | | SPRINKLERS MEETING NFPA 101. | | | | | | 8) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS: | | | A) THE REPORT SUBMITTED DOES HAVE A | | | RAISED SEAL BUT THE SIGNATURE IS COPIED. | | | B) TEST BORING SHEETS COPIED NOT SIGNED | | | OR SEALED. | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 9) SURVEY OR SITE PLAN WITH THE | | | FOOTPRINT LOCATED ON PROPERTY,WITH | | | DIMENSIONS TO THE PROPERTY LINES, | | | TABLE 600,% OF ALLOWABLE OPENINGS. | | | | | | 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 11) HANSON PROFESSIONAL SERVICES TO | | | COMPLY WITH CERTIFICATE OF AUTHORIZATION | | | NUMBER TO BE ON PLANS, THE ADDRESS | | | LISTED WITH THE STATE OF FL IS | | | SPRINGFIELD, ILL. 481.219 F.S. | | | CERTIFICATE OF AUTHORIZATION.THE TITLE | | | BLOCK FOR ANY SHEET BEARING THE NAME OF | | | AN ARCHITECT PRACTICING UNDER A | | | FICTITIOUS NAME, A CORPORATION, OR A | | | PARTNERSHIP, OFFERING ARCHITECTURAL | | | SERVICES, SHALL INCLUDE THE CERTIFICATE | | | OF AUTHORIZATION NUMBER. | | | | | | 12)A-0.1 CONSTRUCTION TYPE INDICATES THE | | | BUILDING TO BE A TYPE IV, UNPROTECTED, | | | FULLY SPRINKLERED STRUCTURE, HOWEVER | | | SHEET A-3.0 INDICATES TOP OF BUILDING TO | | | BE 71.66' WITH 6 STORIES. THIS IS IN | | | EXCESS OF THE ALLOWABLE 55' AND 5 | | | STORIES ALLOWED UNDER TABLE 500. | | | FOOTNOTE "H" DOES NOT ALLOW FOR A STORY | | | INCREASE.THIS IS A TYPE II | | | CONSTRUCTION. SEE TABLE 500 AND 604. | | | | | | 13A) PROVIDE: 11-4.1.2(1) AT LEAST ONE | | | ACCESSIBLE ROUTE COMPLYING WITH 11-4.3 | | | SHALL PROVIDED WITHIN THE BOUNDARY OF | | | THE SITE FROM PUBLIC TRANSPORTATION | | | STOPS, ACCESSIBLE PARKING SPACES, | | | PASSENGER LOADING ZONES IF PROVIDED, AND | | | PUBLIC STREETS OR SIDEWALKS, TO AN | | | ACCESSIBLE BUILDING ENTRANCE. | | | | | | 13B) PROVIDE: 11-4.1.3(1) AT LEAST ONE | | | ACCESSIBLE ROUTE COMPLYING WITH 11-4.3 | | | SHALL CONNECT ACCESSIBLE BUILDING OR | | | FACILITY ENETRANCES WITH ALL ACCESSIBLE | | | SPACES AND ELEMENTS WITHIN THE BUILDING | | | OR FACILITY. | | | | | | 14)11-4.6.2 LOCATION. ACCESSIBLE PARKING | | | SPACES SERVING A PARTICULARBUILDING | | | SHALL BE LOCATED ON THE SHORTEST SAFELY | | | ACCESSIBLE ROUTE OFTRAVEL FROM | | | ADJACENT PARKING TO AN ACCESSIBLE | | | ENTRANCE.IN PARKINGFACILITIES THAT | | | DO NOT SERVE A PARTICULAR BUILDING, | | | ACCESSIBLE PARKINGSHALL BE LOCATED ON | | | THE SHORTEST ACCESSIBLE ROUTE OF TRAVEL | | | TO ANACCESSIBLE PEDESTRIAN ENTRANCE | | | OF THE PARKING FACILITY.IN BUILDINGS | | | WITHMULTIPLE ACCESSIBLE ENTRANCES | | | WITH ADJACENT PARKING, ACCESSIBLE | | | PARKING SPACES SHALL BE DISPERSED AND | | | LOCATED CLOSEST TO THE ACCESSIBLE | | | ENTRANCES. EACH PARKING SPACE MUST BE NO | | | LESS THAN 12 FEET WIDE. | | | | | | 15) PROVIDE COMPLIANCE WITH HEAD ROOM | | | BENEATH STAIRS- A BARRIEER TO WARN BLIND | | | OR VISUALLY IMPAIRED PERSONS SHALL BE | | | PROVIDED.11-4.4.2.SEE SHEET A-7.0 . | | | | | | 16A) 11-9.1.2 PLANS INDICATE 120 | | | SLEEPING UNITS, 11-9.1.2 REQUIRES 2 | | | ROOMS WITH ROLL IN SHOWERS, PROVIDE | | | COMPLIANCE. | | | | | | 16B) FL S. S. 509 A NUMBER OF ROOMS | | | EQUALING AT LEAST 5% OF THE GUEST ROOMS | | | MINUS THE NUMBER OF "ACCESSIBLE ROOMS" | | | REQUIRED BY THE TABLE IN 11-9.1.2 SHALL | | | PROVIDE THE ADDITIOINAL SPECIAL | | | ACCESSIBILTY FEATURES OF 11-9.2.3 | | | 11-9.2.3 HOTEL, MOTEL AND CONDOMINIUM | | | SPECIAL ACCESSIBILITY FEATURE. | | | NOTHING IN THIS SECTION SHALL BE | | | CONSTRUED AS RELIEVING THE OWNER OF THE | | | RESPONSIBILITY OF PROVIDING ACCESSIBLE | | | ROOMS IN CONFORMANCE WITH 11-9.1 | | | 11-9.5 OF THE CODE. | | | | | | IN ALL BUILDINGS, STRUCTURES AND | | | FACILITIES LICENSED AS A HOTEL, MOTEL OR | | | RESORT CONDOMINIUM PURSUANT TO CHAPTER | | | 509, FLORIDA STATUTES, A NUMBER | | | OF ROOMS EQUALING AT LEAST 5 PERCENT | | | OF THE GUEST ROOMS MINUS THE NUMBER | | | OF ACCESSIBLE ROOMS REQUIRED BY THE | | | TABLE IN 11-9.1.2 SHALL PROVIDE THE | | | FOLLOWING ADDITIONAL SPECIAL | | | ACCESSIBILITY FEATURES: | | | | | | 11-9.2.3(1) GRAB RAILS IN BATHROOMS | | | AND TOILET ROOMS WHICH COMPLY | | | WITH ?11-4.16.4 OF THIS CODE. | | | | | | 11-9.2.3(2) ALL BEDS IN DESIGNED | | | ACCESSIBLE GUEST ROOMS SHALL BE | | | OPEN-FRAME TYPE TO PERMIT PASSAGE OF | | | LIFT DEVICES. | | | | | | 11-9.2.3(3) ALL STANDARD WATER | | | CLOSET SEATS SHALL BE AT A HEIGHT OF | | | 15 INCHES, MEASURED VERTICALLY FROM | | | THE FINISH FLOOR TO THE TOP OF THE | | | SEAT, WITH A VARIATION OF PLUS OR | | | MINUS 1/2 INCH.A PORTABLE OR | | | ATTACHED RAISED TOILET SEAT SHALL BE | | | PROVIDED IN ALL DESIGNATED | | | PERMANENT DISABILITY ACCESSIBLE | | | ROOMS. | | | | | | | | | 17) 11-9.3.1 GENERAL. IN SLEEPING ROOMS | | | REQUIRED TO COMPLY WITH THISSECTION, | | | AUXILIARY VISUAL ALARMS SHALL BE | | | PROVIDED AND SHALL COMPLY WITH | | | ?11-4.28.4.VISUAL NOTIFICATION | | | DEVICES SHALL ALSO BE PROVIDED IN | | | UNITS, SLEEPING ROOMS AND SUITES TO | | | ALERT ROOM OCCUPANTS OF INCOMING | | | TELEPHONE CALLS AND A DOOR KNOCK OR | | | BELL. | | | | | | 18) 11-9.1.4(1) IN ORDER TO PROVIDE | | | PERSONS WITH DISABILITIES A RANGE OF | | | OPTIONS EQUIVALENT TO THOSE AVAILABLE | | | TO OTHER PERSONS SERVED BY THE | | | FACILITY, SLEEPING ROOMS AND SUITES | | | REQUIRED TO BE ACCESSIBLE BY | | | 11-9.1.2 SHALL BE DISPERSED AMONG THE | | | VARIOUS CLASSES OF SLEEPING | | | ACCOMMODATIONS AVAILABLE TO PATRONS OF | | | THE PLACE OF TRANSIENT LODGING. | | | FACTORS TO BE CONSIDERED INCLUDE ROOM | | | SIZE, COST, AMENITIES PROVIDED, AND | | | THE NUMBER OF BEDS PROVIDED. | | | | | | 19) 11-9.4 OTHER SLEEPING ROOMS AND | | | SUITES. DOORS AND DOORWAYS DESIGNED TO | | | ALLOW PASSAGE INTO AND WITHIN ALL | | | SLEEPING UNITS OR OTHER COVERED UNITS | | | SHALL COMPLY WITH 11-4.13.5. CLEAR | | | WIDTH. | | | | | | 20A) 11-4.10.5 RAISED AND BRAILLE | | | CHARACTERS ON HOISTWAY ENTRANCES. | | | | | | 20B) 11-4.10.12(2) TACTILE, BRAILLE, AND | | | VISUAL CONTROL INDICATORS. | | | | | | 21) 11-4.30 SIGNAGE.?11-4.30.1 | | | GENERAL. SIGNAGE REQUIRED TO BE | | | ACCESSIBLE BY ?11-4.1 SHALL COMPLY WITH | | | THE APPLICABLE PROVISIONS OF ?11-4.30. | | | | | | | | | | | | 22)SHEET A-1.0 HAWTHORN ROOMPROVIDE | | | USEAGE, FOR THIS REVIEW CONSIDERED AS | | | RESTRAUNT OCC LOAD 2104/15= 141 | | | OCCUPANTS REQUIRES (2) EXITS, 1/3 THE | | | DISTANCE OF THE ROOM APART, 1004.1.4 | | | WHERE 2 OR MORE EXITS OR EXIT ACCESS | | | DOORS ARE REQUIED, AT LEAST 2 OF THE | | | EXIT OR EXIT ACCESS DOORS SHALL BE | | | PLACED A DISTANCE APART EQUAL TO NOT | | | LESS THAN 1/2 OF THE LENGTH OF THE | | | MAXIMUM OVERALL DIAGONAL DIMENSION OF | | | THE BUILDING OR AREA TO BE SERVED, | | | (1/3RD DISTANCE FOR FIRE SPRINKLERED | | | BUILDINGS). | | | | | | 23)SHEET A-1.0,/A- 6.3 TRIM CIRCULAR | | | COLUMN WRAP, CHAIRAIL AND 8" CROWN | | | MOLDING, PROVIDE ADDITIONAL DETAILS SEE | | | 803.4 FOAM PLASTICS. FOAM PLASTICS SHALL | | | NOT BE USED AS INTERIOR FINISH.4 | | | EXECPTIONS. | | | | | | 24) SHEET A-1.0705.2.4.1 GENERAL. | | | REFUSE AND LAUNDRY CHUTES, ACCESS AND | | | TERMINATION ROOMS AND INCINERATOR ROOMS | | | SHALL BE CONSTRUCTED IN ACCORDANCE WITH | | | 705.2.4.2 THROUGH 705.2.4.6.INDICATE | | | COMPLIANCE | | | | | | 25) SHEET A-1.0 705.2.4.4 TERMINATION | | | ROOM. REFUSE AND LAUNDRY CHUTES SHALL | | | DISCHARGE INTO AN ENCLOSED TERMINATION | | | ROOM COMPLETELY SEPARATED FROM THE | | | REMAINDER OF THE BUILDING BY | | | CONSTRUCTION AND OPENING PROTECTIVES | | | IN ACCORDANCE WITH TABLE 705.1.2. | | | REFUSE CHUTES SHALL NOT TERMINATE IN AN | | | INCINERATOR ROOM. INDICATE COMPLIANCE | | | | | | 26) SHEET A-1.2/ A-1.3705.2.4.3 | | | REFUSE AND LAUNDRY CHUTE ACCESS ROOMS. | | | ACCESS OPENINGSFOR REFUSE AND | | | LAUNDRY CHUTES SHALL BE LOCATED IN ROOMS | | | OR COMPARTMENTSCOMPLETELY ENCLOSED | | | BY CONSTRUCTION AND OPENING PROTECTIVES | | | IN ACCORDANCE WITH TABLE 705.1.2. | | | ACCESS OPENINGS TO REFUSE AND LAUNDRY | | | CHUTES SHALL NOT BE LOCATED IN EXIT | | | ACCESS CORRIDORS OR EXIT ENCLOSURES. | | | INDICATE COMPLIANCE. | | | | | | 27) ALL RATED CORRIDORS, ETC: | | | 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 28) 1016.4 STAIR IDENTIFICATION. AN | | | APPROVED SIGN SHALL BE LOCATED AT EACH | | | FLOOR LEVEL LANDING IN ALL ENCLOSED | | | STAIRWAYS OF BUILDINGS FOUR OR MORE | | | STORIES IN HEIGHT.THE SIGN SHALL | | | INDICATE THE FLOOR LEVEL AND THE | | | AVAILABILITY OF ROOF ACCESS FROM THAT | | | STAIRWAY AND AN IDENTIFICATION OF THE | | | STAIRWAY.THE SIGN SHALL ALSO STATE THE | | | FLOOR LEVEL OF AND DIRECTION TO | | | EXIT DISCHARGE.THE SIGN SHALL BE | | | LOCATED APPROXIMATELY 5 FT (1524 MM) | | | ABOVE THE FLOOR LANDING IN A POSITION | | | WHICH IS READILY VISIBLE WHEN THE | | | DOOR IS IN THE OPEN OR CLOSED POSITION. | | | | | | 29) SHEET A-1.3 INDICATES A EXIT ONTO | | | THE ROOF DOOR 615B/ 615 A, SEE 1006.2.2 | | | FOR REQUIRED ROOF-OVER BALCONY, PORCH OR | | | GALLERY. | | | | | | 30) SHEET A-1.3 DETAIL A-5.2 DETAIL# 4 | | | INDICATES A USE OF A RAISED WALKABLW | | | DECK AND HANDRAIL. PROVIDE DETAILS FOR | | | GAURDRAIL, INDICATE COMPLIANCE WITH: | | | | | | 30A)11015.3 OPENINGS. OPEN GUARDRAILS | | | SHALL HAVE INTERMEDIATE RAILS OR | | | ORNAMENTAL PATTERN SUCH THAT A 4-INCH | | | (102 MM) DIAMETER SPHERE CANNOT PASS | | | THROUGH ANY OPENING UP TO A HEIGHT OF 34 | | | INCHES.A BOTTOM RAIL OR CURB | | | SHALL BE PROVIDED THAT WILL REJECT THE | | | PASSAGE OF 2-INCH (51 MM) DIAMETER | | | SPHERE. | | | | | | 30B)1608.2.2.1 GUARDRAIL SYSTEMS SHALL | | | BE DESIGNED AND CONSTRUCTED FOR A | | | CONCENTRATED LOAD OF 200 LB (890 N) | | | APPLIED AT ANY POINT AND IN ANY | | | DIRECTION AT THE TOP OF THE GUARDRAIL. | | | | | | 30C)1608.2.2.2 GUARDRAIL SYSTEMS LOCATED | | | OTHER THAN WITHIN DWELLING UNITS SHALL | | | BE DESIGNED AND CONSTRUCTED FOR A LOAD | | | OF 50 PLF (730 N/M) APPLIED HORIZONTALLY | | | AT THE REQUIRED GUARDRAIL HEIGHT AND A | | | SIMULTANEOUS LOAD OF 100 PLF (1459 N/M) | | | APPLIED VERTICALLY DOWNWARD AT THE TOP | | | OF THE GUARDRAIL. | | | | | | 30D) 1608.2.2.3 THE GUARDRAIL SYSTEM | | | SHALL ALSO BE DESIGNED ANDCONSTRUCTED TO | | | RESIST A 200 LB (890 N) CONCENTRATED | | | HORIZONTAL LOAD APPLIED ON A 1 SQ FT | | | AREA (0.093 M^2) AT ANY POINT IN THE | | | SYSTEM INCLUDING INTERMEDIATE RAILS OR | | | OTHER ELEMENTS SERVING THIS PURPOSE. | | | | | | 31) SHEET A-1.3 ROOM 621 A MULTI-PURPOSE | | | ROOM WITH AN OCC LOAD OF 260 (ASSEMBLY | | | OCCUPANCY) REQUIRES A 2HR RATED WALL/ | | | WITH 1 1/2 HR RATED DOORS, SEE TABLE | | | 705.1.2. | | | | | | 32A) SHEET A-1.3 CONFERENCE ROOM | | | INDICATES A 1 HR RATED WALL, PROVIDE | | | INFORMATION ON THE RATING OF WINDOW NEXT | | | TO DOOR.TABLE 705.1.2. | | | | | | 32B)THIS SAME WINDOW TO BE SAFETY GLASS, | | | HAZARDOUS AREA. FL BLD CODE 2405.2 | | | HAZARDOUS LOCATION PROVIDE SAFETY GLASS | | | FOR THIS LOCATION. | | | | | | 33) SHEET A-4.1 DETAIL 3 INDICATES THE | | | USE OF ELEVATED SLABS & CMU. 2111.1.9* | | | LOCAL AMENDMENT, WHERE EXTERIOR WALL | | | MASONARY UNITS BEAR ON A CONCRETE FLOOR | | | SURFACE, A 1.5" RECESS SHALL BE PROVIDED | | | TO MINIMIZE WATER INTRUSION INTO | | | FINISHED AREAS. | | | | | | 34) SHEET A-5.0 DETAIL# 6, THE CANOPY | | | DETAIL INDICATES THE CEILING OF THE | | | CANOPY TO BE CONSTRUCTED OF STUCCO ON | | | 5/8" CEMENT BOARD. PROVIDE ADDITIONAL | | | INFORMATION. THE STO PRODUCT APPROVAL | | | SUBMITTED UNDER LIMITATIONS 3.1 "THIS | | | SYSTEM IS NOT TO BE USED ON HORIZONTAL | | | SURFACES. | | | | | | 35) THE PLANS ALSO INDICATE THE USE OF | | | EFIS SYSTEMS FOR THE EXTERIOR WALLS, | | | | | | 35A) THE SUBMITTED STO EFIS REPORT | | | INDICATES THAT IT WAS TESTED WITH STUDS | | | AND PLYWOOD SUBSTRATE, PROVIDE TEESTING | | | REPORT FOR THE ASSEMBLY THAT WILL BE | | | USED FOR TYPE II BUILDING, SECTION 604 | | | NONCOMBUSTIBLE EXTERIOR WALLS. | | | | | | 35B) SHOW COMPLIANCE WITH :2603.6 | | | EXTERIOR WALLS OF BUILDINGS OF ANY | | | HEIGHT. EXTERIOR WALLS OF | | | BUILDINGS OF TYPES I, II, III, IV AND V0 | | | CONSTRUCTION OF ANY HEIGHT SHALL | | | COMPLY WITH ?2603.6.1 THROUGH ?2603.6.7. | | | | | | 35C)1404.1.1 ARCHITECTURAL TRIM ON | | | BUILDINGS OF TYPE I, II AND IV | | | CONSTRUCTION NOT MORE THAN THREE STORIES | | | OR 40 FT (12.2 M) HIGH MAY BE OF | | | TYPE VI CONSTRUCTION, AND MAY BE OF TYPE | | | VI CONSTRUCTION ON ALL BUILDINGS | | | OF TYPE III, V AND VI CONSTRUCTION. | | | TRIM SHALL BE SECURED TO THE WALL | | | WITH METAL OR OTHER APPROVED BRACKETS OR | | | FASTENERS.WHEN ARCHITECTURAL | | | TRIM IS LOCATED ALONG THE TOP OF | | | EXTERIOR WALLS, IT SHALL BE COMPLETELY | | | BACKED BY THE EXTERIOR WALL AND SHALL | | | NOT EXTEND OVER THE TOP OF EXTERIOR | | | WALLS. | | | | | | 36) S-7 CODE DESIGN NOTES INDICATE THAT | | | THIS 6 STORY STRUCTURE WAAS DESIGNED TO | | | ASCE 7-98, EXPOSURE "C". PROVIDE THE | | | POSITIVE AND NEGATIVE PRESSURES FOR | | | WALLS, INTERIOR AND END ZONES FOR THE | | | EFIS APPLICATION,1606.1.1./ CHAPTER 6 | | | ASCE 7-98. | | | | | | 37) IN READING THE ICC REPORT SUBMITTED | | | FOR 5/8" DENS-GLASS GOLD THE REPORT | | | STATES (7.4)IT IS PERMITTED WHERE THE | | | DESIGN WIND PRESSURES DO NOT EXCEED | | | 21.7 PSF. | | | | | | 38) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 39) PRODUCT APPROVAL- ROOFING JOHN | | | MANVILLE MODIFIED BITUMEN ROOF SYSTEMS, | | | THIS REPORT THIS REPORT HAS (8) | | | APPLICATIONS SOME INSULATEDAND OTHERS | | | NON-INSULATED. DEPENDING ONWHICH REPORT | | | USED, THE PRESSURES MAY HAVE LIMITATION | | | 7 OR 9 NOT ALLOWING INCREASES. HIGHLIGHT | | | THE REPORT TO BE USED.!!!!!! | | | | | | 40) CURRIES EXTERIOR DOORS THE | | | 6'X7'DOORS LOCATED IN END ZONE 5 WILL | | | REQUIRE -121PSF, SUBMITTED REPORTS LOW | | | PRESSURE OR REPORTS ARE EXPIRED. SEE | | | DOORS 130B & 137B.CURRIES 747 16 GA LOW | | | PRESSURE REPORT ONLY GOOD FOR -62. | | | | | | 41) RESAM AES AUTO DOORS- LOW PRESSURE | | | | | | 42) PGT HORIZONTAL ROLLER WINDOWHR-810: | | | LOW PRESSURES IN ZONE# 5, MISSING FL | | | COVERSHEET. | | | | | | 43) MISSING REPORTS FOR WALL LOUVER, | | | NO FL COVERSHEET. | | | | | | 44) EXTERIOR GUARDRAILS, MISSING PRODUCT | | | APPROVALS & FL COVERSHEET. | | | | | | 45) FIXED WINDOWS, ABOVE AUTOMATIC | | | SLIDING DOORS, NO REPORT,OR FL COVER | | | SHEET. | | | | | | 46A) HORIZONTAL MULLION OVER FRONT | | | HORIZONTAL SLIDING ENTRY DOOR. NO REPORT | | | NOR FL COVERSHEET. | | | | | | 46B) 1707.4.5.1 MULLIONS OCCURRING | | | BETWEEN INDIVIDUAL WINDOW AND GLASS | | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | | REQUIRED BY AN APPROVED TESTING | | | LABORATORY OR BE ENGINEERED. | | | | | | 46C) 1707.4.5.2 MULLIONS SHALL BE | | | DESIGN- ED TO TRANSFER THE DESIGN | | | PRESSURE LOADS APPLIED BY THE WINDOW OR | | | DOOR ASSEMBLIES TO THE ROUGH OPENING | | | SUBTRATE. | | | | | | 47) 3003.6.1 VENTS. HOISTWAYS OF ELEVA- | | | TORS SERVING MORE THAN 3 FLOORS SHALL BE | | | PROVIDED WITH MEANS OF VENTING SMOKE AND | | | HOT GASES TO THE OUTER AIR IN CASE OF | | | FIRE. | | | | | | 48) 3003.6.3 THE AREA OF THE VENTS SHALL | | | BE NOT LESS THAN 3 SQ FT FOR EACH | | | ELEVATOR CAR, WHICHEVER IS GREATER. | | | | | | 49) 3003.7.1 ACCESS TO MACHINE ROOMS AND | | | MACHINERY SPACES. A PERMANENT, SAFE AND | | | CONVENIENT MEANS OF ACCESS TO ELEVA- TOR | | | MACHINE ROOMS AND OVERHEAD MACHINERY | | | SPACES SHALL BE PROVIDED FOR AUTHORIZED | | | PERSONAL. THE MEANS OF ACCESS SHALL NOT | | | BE THROUGH RESTROOMS, DRESSING ROOMS, | | | OR TENANT ( INCLUDING OWNER-OCCUPIED) | | | SPACES. | | | | | | 50) 3003.4.1 IN ALL STRUCTURES THAT ARE | | | MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE | | | BOTTOM TERMINAL LANDING AND THE | | | TOP TERMINAL LANDING EXCEEDS 25 FEET | | | (7.6 M) MUST BE CONSTRUCTED TO | | | CONTAIN AT LEAST ONE PASSENGER LEVATOR | | | THAT IS OPERATIONAL AND WILL | | | ACCOMMODATE AN AMBULANCE STRETCHER 76 | | | INCHES (1931 MM) LONG AND 24 INCHES | | | (610 MM) WIDE IN THE HORIZONTAL | | | POSITION.THIS ELEVATOR SHALL BE | | | IDENTIFIED. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
22 |
Status |
P |
Date |
2009-10-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-10-14 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-10-14 |
Time |
14:52 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
21 |
Status |
F |
Date |
2008-05-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-22 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-22 |
Time |
11:41 |
Sent To |
B |
|
| Notes |
| 2008-05-22 11:41:20 | ** DENIEDREVIEW** | | | | | | | | | | | | 1) NOTE: PLEASE KNOW THE LETTER SUBMITTED BY THE | | | GENERAC BUSINESS DEVELOPMENT MANAGER IS NOT ACCEPTABLE. | | | THE GENERATOR SHALL BE INSTALLED AT A MINIMUM PER THE | | | MANUFACTURES SPECS/CUT SHEET WHICH IS ALREADY ON FILE. | | | THIS UNIT PER PREVIOUS SPECS STATE A MINIMUM OF 5FT | | | AROUND UNIT. | | | IN EITHER CASE COMBUSTIBLES WILL ALSO BE NOTED UNDER | | | BUILDING/FIRE MARSHAL REVIEW. | | | PLEASE SEE NFPA-110 WHICH REQUIRES INSTALLATION PER | | | CHAPTER 7. THERE ARE TOO MANY CODE SECTIONS TO LIST. | | | PLEASE SEE THE CHAPTER AS NOTED. | | | PLEASE SEE THE MINIMUM REQUIREMENTS FOR INSTALLATION | | | FOR ELECTRICAL SHALL MEET 110.3, 90.7, 110.26. AS SHOWN | | | THIS UNIT WITH INSTALLED WOOD FENCING WITHIN 6 INCHES | | | OF GENERATOR DOES NOT MEET ANY KNOWN CODES AND NOT THE | | | GENERATOR MANUFACTURES INSTALLATION INSTRUCTIONS FOR | | | MINIMUM CLEARANCES. | | | | | | ** AS THIS IS A LIFE SAFETY/ EMERGENCY GENERATOR, THE | | | WALL ENCLOSURE AS INSTALLED AND SHOWN SHALL BE REMOVED | | | IMMEDIATELY UNTIL ALL CODE ITEMS ARE RESOLVED. THIS IS | | | A FIRE/LIFE SAFETY AND PROPERTY HAZARD. | | | | | | | | | | | | | | | ** IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
20 |
Status |
F |
Date |
2008-05-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-04 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-04 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2008-05-04 12:59:32 | ** DENIED REVISIONS** | | | | | | ** REVIEW BASED ON NEW PLANS NOW SUBMITTED WHICH WERE | | | NOT PREVIOUSLY SUBMITTED SHOWING THE ENCLOSURE. | | | | | | 1) NOTE: PLEASE KNOW THE PLANS NOW SHOW AN ENCLOSURE | | | BUILT RIGHT UP NEXT TO THE GENERATOR. PLEASE PROVIDE | | | THE MINIMUM CLEARANCES PER THE GENERATOR MANUFACTURE. | | | THIS OFFICE IS NOT AWARE OF ANY GENERATOR MANUFACTURE | | | WHO ALLOWS ONLY 6 INCHES OF CLEARANCE ON THE SIDES. IN | | | FACT THIS MANUFACTURE AS SUBMITTED REQUIRED AS MUCH AS | | | 5FT ON PREVIOUS PROJECTS/DOCUMENTS SUBMITTED TO THIS | | | OFFICE ON PREVIOUS REVIEWS. | | | PLEASE ALSO KNOW THAT REMOVABLE PANELS ARE NOT | | | ACCEPTABLE AS THESE ARE NOT READILY ACCESSIBLE OR | | | ACCESSIBLE AS REQUIRED BY CODE. | | | THIS IS A LIFE SAFETY AND FIRE HAZARD AND THIS FENCING | | | SHALL BE REMOVED IMMEDIATELY UNTIL SUCH TIME AS MINIMUM | | | CODE COMPLIANCE IS DETERMINED.BASED ON INFORMATION TO | | | THIS OFFICE THIS IS A CURRENT HAZARD. THIS INFORMATION | | | HAS BEEN FORWARDED TO INSPECTION SERVICES AS OF THIS | | | REVIEW. | | | PLEASE SEE THE LIMITATIONS AS SHOWN ON PLANS WITH ONLY | | | 6 INCHES ON TWO SIDES AND ONLY 1.5 AND 2FT ON THE OTHER | | | IS NOT PERMITTED. | | | MUST SUPPLY *MINIMUM* PER CODE AND MANUFACTURE. | | | 90.7, 110.3, 110.26, 100, 700.12B6, 701.10B5, 702.11 | | | PLEASE ALSO SEE SECTION 7 OF NFPA-110. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
19 |
Status |
F |
Date |
2008-04-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-24 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-24 |
Time |
16:03 |
Sent To |
PC |
|
| Notes |
| 2008-04-24 16:05:15 | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE SEE NOTES DATED 4/7/08 WHICH REQUESTED | | | SUBMISSION OF UPDATED SHEETS FOR OTHER TRADES SUCH AS | | | ARCHITECTURAL, SITE ETC. | | | STILL NEED UPDATE SLAB DETAILS, ELEVATION, TIE DOWN, | | | OVER TURN DETAILS AS REQUIRE DIN FBC AND NFPA-110 | | | CHAPTER 7. | | | PLEASE KNOW ONCE THE OTHER DETAILS AND PLANS ARE | | | REVIEWED AND MEET THE REQUIREMENTS OF THE FBC AND OTHER | | | ADOPTED CODES ELECTRICAL REVIEW WILL BE OK. | | | | | | 2) NOTE: PLEASE SEE THAT THREE SETS OF THE MANUFACTURES | | | SPECS/CUT SHEETS ARE SUBMITTED. | | | FBC106.1.2 THIS IS A THRESHOLD PROJECT. | | | ONE COMPLETE SET REMAINS ON FILE THE OTHER TWO ARE FOR | | | JOB-SITE. | | | | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
18 |
Status |
F |
Date |
2008-04-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-07 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
PC |
|
| Notes |
| 2008-04-07 11:18:27 | STILL NEED TO SUBMIT REVISED PLANS FOR GENERATOR WHICH | | | IS TO INCLUDE REVISED SITE, ELECTRICAL, MECHANICAL, AND | | | ARCHITECTURAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
17 |
Status |
P |
Date |
2008-02-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-02-07 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-02-07 |
Time |
10:18 |
Sent To |
PC |
|
| Notes |
| 2008-02-07 10:19:33 | GENERATOR ONLY ON ELEC RISER. IS NOT ON OTHER PLANS OR | | | SHEETS FOR ANY OTHER TRADE REVIEWS SINCE BEGINING OF | | | PROJECT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
16 |
Status |
P |
Date |
2008-01-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-22 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-22 |
Time |
09:11 |
Sent To |
PC |
|
| Notes |
| 2008-01-22 09:14:51 | REDLINED NEUTRAL SHOWN FOR FIRE PUMP. THIS CONDUCTOR | | | MAY NOT BE SMALLER THAN THE GROUNDING ELECTRODE. | | | 250.24C, 230.42C |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
15 |
Status |
P |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-28 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-28 |
Time |
15:33 |
Sent To |
M |
|
| Notes |
| 2007-11-28 15:34:14 | ENERGY CALCS STAMPED FOR ELEC ONLY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
14 |
Status |
P |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-27 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-27 |
Time |
11:03 |
Sent To |
PC |
|
| Notes |
| 2007-11-27 11:05:34 | REDLINED, NEUTRAL CONDUCTOR FOR FIRE PUMP SHALL NOT BE | | | SMALLER THAN GROUNDING ELECTRODE CONDUCTOR. | | | 230.42C, 250.24C. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
13 |
Status |
F |
Date |
2007-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-27 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-27 |
Time |
09:33 |
Sent To |
PC |
|
| Notes |
| 2007-10-27 10:09:02 | ** DENIED REVISION ** | | | | | | 1) NOTE: PLEASE SEE COMMENTS FROM TWO PREVIOUS REVIEWS | | | AS THE COMMENTS WITH RESPECT THE ENERGY CALCULATIONS | | | HAS NOT YET BEEN ADDRESSED. AS PREVIOUSLY MENTIONED NO | | | FURTHER ELECTRICAL REVISIONS WILL BE GRANTED UNTIL THE | | | CALCULATIONS HAVE BEEN CORRECTED, SUBMITTED AND ARE | | | CODE COMPLIANT FOR BUILDING BEING CONSTRUCTED. | | | FBC 2001 CHAPTER 13. | | | | | | 2) NOTE: PLEASE SEE MISSING NEUTRAL CONDUCTOR TO THE | | | FIRST MEANS OF DISCONNECT AT THE FIRE PUMP CONTROLLER. | | | PLEASE SEE THE PLANS HAVE NOW BEEN REVISED TO INDICATE | | | AN INCREASE IN FIRE PUMP FROM 20HP TO 60HP. | | | PLEASE PROVIDE NEW LOCK ROTOR OVER CURRENT PROTECTION. | | | PLEASE SUBMIT NEW MANUFACTURES SPECS/CUT SHEETS FOR THE | | | NEW FIRE PUMP CONTROLLER, AND FIRE PUMP. | | | PLEASE SEE THE FIRE SPRINKLER PLANS ON FILE DO NOT | | | CORRELATE WITH SIZE AND WILL BE REQUIRED TO BE REVISED | | | ALSO. | | | PLEASE SEE 250.20, 250.24, ETC FOR GROUNDED NEUTRAL. IS | | | THE #2 AS SHOWN ON #27 NOTE FROM FPL THE NEUTRAL? IF SO | | | PLEASE COORDINATE THIS WITH NOTE #3. | | | OTHER ADDITIONAL INFORMATION AND COORDINATION PER | | | 104.1.2, OF 2001 FBC AND NEC 695.4, NFPA-20, NEC 110.3, | | | 90.7 ETC. | | | | | | 3) NOTE: PLEASE SEE UNIT B MISSING BEDROOM #2 | | | RECEPTACLE PER 210.62, 210.52 | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. | | | PLEASE ADDRESS COMMENT NUMBER #1. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
12 |
Status |
F |
Date |
2007-10-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-05 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-05 |
Time |
12:11 |
Sent To |
M |
|
| Notes |
| 2007-10-05 12:29:05 | *** DENIED REVISION *** | | | | | | | | | 1) NOTE:PLEASE SUBMIT COMPLETED ENERGY CALCULATIONS | | | WHICH COORDINATE ALL LIGHTING ON PLANS AND FIXTURE | | | LEGEND. PLEASE SEE THE INPUT DATA REPORT NEEDS ALL | | | ITEMS ON PLANS WHICH CONSUME ENERGY AND PROVIDES | | | EFFICIENCY TO BE ON THE IDR. | | | PLEASE SEE THE LIGHTING FIXTURE WATTAGES AS SHOWN DO | | | NOT MATCH WITH THE LIGHTING FIXTURES WATTAGES AS SHOWN | | | AND LISTED ON PLANS. | | | PLEASE SEE THAT NO EXTERIOR LIGHTING COULD BE FOUND ON | | | THE IDR SO NO REVIEW OF THESE COULD BE DONE. CHAPTER | | | 13, 400.2, 400.3.A, 415.1.AB.1, 415.1.A, TABLE 4-15, | | | 415.2 ETC. | | | PLEASE CLARIFY HOW 13-415.1.ABCD.1.1.4 IS MET? | | | | | | CALCULATIONS WILL BE ROUTED TO OTHER TRADES. | | | | | | IF THERE ARE ANY QUESTIONS AS STATED ON PREVIOUS | | | REVIEW | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
11 |
Status |
F |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-27 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-27 |
Time |
14:37 |
Sent To |
PC |
|
| Notes |
| 2007-08-27 14:37:54 | | | | SOME SHEETS OK, AND STAMPED. | | | | | | | | | | | | | | | | | | *** DENIED*** | | | | | | SHEETS E16 | | | | | | 1) NOTE: PLEASE SEE THE NOTES ON THE ENERGY | | | CALCULATIONS AS NO FURTHER REVISIONS WILL BE ACCEPTED | | | UNTIL THE COMMENTS ARE CORRECTED FOR THE FBC CHAPTER 13 | | | REQUIREMENTS. | | | | | | | | | 2) NOTE: PLEASE SEE THE REVISED SHEET E-16 AS THERE ARE | | | FEEDERS WHICH DO NOT MEET THE MINIMUM SIZE PER THE | | | NEC. | | | PLEASE SEE 240.4 WHEN A CONDUCTOR SIZE DOES NOT | | | COORDINATE WITH THE OVER CURRENT PROTECTION DEVICES, IT | | | IS PERMISSIBLE TO GO THE NEXT STANDARD SIZE OVER | | | CURRENT PROTECTION PER 240.6, HOWEVER YOU MAY NOT | | | EXCEED THAT NEXT STANDARD SIZE. | | | PLEASE SEE THE MINIMUM FEEDERS FOR EEP AND P1A | | | 110.14, 240.4, 310.16 | | | | | | PLEASE REVISE. | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
P |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-27 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-27 |
Time |
14:38 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-27 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-27 |
Time |
14:38 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-27 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-27 |
Time |
07:44 |
Sent To |
PC |
|
| Notes |
| 2007-08-27 07:45:15 | *** DENIED *** | | | | | | 1) NOTE: PLEASE SEE THE ENERGY CALCULATIONS AS | | | SUBMITTED ARE DONE UNDER THE 2004 EDITION OF THE FBC | | | WITH THE 2006 REVISIONS. | | | ** THIS PROJECT IS UNDER THE 2001 FBC. PLEASE SEE | | | 13-400, 13-400.3, 13-400.3.ABCD,.1, .2, AND.3. | | | | | | ** NO REVIEW OF CALCULATIONS COULD BE DONE AT THIS | | | TIME. | | | | | | ** PLEASE KNOW THIS WILL HOLD UP AND OR DELAY ANY TCO | | | AND CO FOR PROJECT AS THERE COULD BE ITEMS WHICH MAY | | | NEED TO BE CHANGED OR ADJUSTED ON SITE. | | | | | | ** THESE HAVE BEEN NOTED AND ON HOLD AS OF 7/9/07 | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-06 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-06 |
Time |
12:56 |
Sent To |
PC |
|
| Notes |
| 2007-08-06 13:09:41 | **HOLD ** | | | | | | | | | PLANS UNDER "T" FOR PU, AS THE REVISED ENERGY | | | CALCUALTIONS WERE NOT SUBMITTED. | | | CALLED CONTRACTOR TWICE AND LEFT MESSAGES. TWO SETS OF | | | REVISIONS SUBMITTED ARE UNDER "T" ON HOLD FOR REVIEW. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-06 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-07 |
Time |
12:19 |
Sent To |
PC |
|
| Notes |
| 2007-08-06 13:10:52 | PLANS UNDER T ON HOLD. | | | CALLED CONTRACTOR TWICE. | | 2007-07-07 13:18:44 | 2007-07-07 13:18:44 | | | PLANS PLACED OUTFRONT. | | 2007-07-07 13:18:05 | ** PLANS ARE ON HOLD UNTIL MONDAY 7/9/07. | | | THE PREVIOUS REVIEW REQUESTED REVISED ENERGY | | | CALCULATIONS WHICH NEED TO CORRELATE WITH PLANS AS | | | LIGHTING WAS REVISED. | | | CALLED THE CONTRACTOR AND LEFT MESSAGE TO CALL ASAP. DV | | | PALMER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-06-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-09 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-09 |
Time |
16:44 |
Sent To |
PC |
|
| Notes |
| 2007-06-09 17:28:25 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE PERMIT 07050818 FOR LV DATA AND | | | VOICE HAS BEEN PLACED ON HOLD FOR NO INSPECTIONS AS | | | THESE SYSTEMS WERE NOT ON PRIMARY PLANS AND THE | | | REVISION HAVE FAILED WITH COMMENTS FOR THESE ITEMS. | | | | | | 2) NOTE: PLEASE SEE THAT NO LOW VOLTAGE PERMIT HAS BEEN | | | APPLIED FOR ALL OTHER LOW VOLTAGE SYSTEMS FOR | | | CATV/PHONE SYSTEMS WHICH ARE ONE MASTER/PRIME PLANS. | | | PLEASE SE FBC ADMIN SECTION 105.1 WHICH REQUIRES | | | PERMITS. THE VALUE IS BASED ON THESE SEPARATELY AS THE | | | FBC VALUATION TABLES FOR PERMIT DOES NOT INCLUDE LV. | | | | | | 3) NOTE: PLEASE SEE THE VOICE/DATA OUTLETS ARE NO ADDED | | | TO PLANS AS *HAND-DRAWN* WHICH IS NOT PERMITTED UNDER | | | FS 471.025. NO CHANGES ARE TO BE MADE TO THE ENGINEERS | | | PLANS. | | | PLEASE KNOW AS THESE ITEMS WERE NOT PART OF THE | | | ORIGINAL PLANS, SEPARATE PLANS ARE TO BE SUBMITTED | | | WHICH WILL BE PLACED UNDER PERMIT WHICH IS NOTED ABOVE | | | BEING PLACED ON HOLD. | | | | | | | | | 4) NOTE: PLEASE SEE AS IT APPEARS SOME LIGHTING HAS | | | BEEN REVISED, PLEASE SUBMIT REVISED ENERGY CALCULATIONS | | | PER FBC CHAPTER 13. | | | | | | 5) NOTE: PLEASE SEE THAT THE PARCEL CONTAINS SEVERAL | | | HOLDS FROM THE ASSISTANT BUILDING OFFICIAL, LICENSE | | | SUPERVISOR AND ADDRESSING REVIEWER. PLEASE SEE HOLDS | | | STATES ADDRESS IS TO BE CHANGED AND NO PERMITS CAN BE | | | ISSUED UNTIL THESE ITEMS ARE DONE. | | | PLEASE CONTACT THE ADDRESSING REVIEWER AND THE ABOVE | | | MENTIONED PERSON FOR NEW ADDRESS AS THE TITLE BLOCKS ON | | | PLANS WILL BE REQUIRED TO COORDINATE FOR THESE. PLEASE | | | ISSUE ALL NEW REVISED SHEETS FOR ELECTRICAL ONCE THIS | | | IS DONE. | | | | | | 6) NOTE: PLEASE SEE REDLINED PLANS WHICH REQUESTED UPON | | | ISSUANCE OF PERMIT FOR NOTES FOR SIGNAGE ON STORAGE | | | ROOM DOORS AND OTHER REDLINED NOTES. PLEASE SEE THE | | | PREVIOUS REVIEW ON 7/15/2006 AND NOTES BELOW WHICH ARE | | | FROM REDLINED PLANS AND REVIEW OF THAT DATE. | | | | | | | | | **** NOTES REDLINED **** | | | | | | | | | 1) EM BATTERY BACK LT FIXTURE OF SOME | | | SORT WILL BE REQUIRED IN THE FIRE PUMP | | | RM. LS 101 7.8,7.9, NEC 700.16. | | | | | | | | | 2) SIGNAGE REQUIRED AT ALL DOORS FOR ENTRANCE THROUGH | | | STORAGE RMS TO ELECTRICAL ROOMS. SIGNAGE SHALL INCLUDE | | | WORDING. "CLEAR PATH OF EGRESS TO ALL ELECTRICAL ROOMS | | | SHALL BE MAINTAINED AT ALL TIMES" OR WORDS TO THAT | | | EFFECT. | | | MIN 1" LTRS ON CONTRASTING BACK AND SIGNAGE SHALL BE | | | PERMANENTLY AFFIXED. | | | | | | 3) SIGNAGE REQUIRED FOR ALL MAINS AND DISCONNECTING | | | MEANS. | | | 230.2E,700.8,701.9 | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-07-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-15 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-15 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2006-07-15 00:00:00 | **** NOTES REDLINED **** | | | | | | | | | 1) EM BATTERY BACK LT FIXTURE OF SOME | | | SORT WILL BE REQUIRED IN THE FIRE PUMP | | | RM. LS 101 7.8,7.9, NEC 700.16. | | | | | | | | | 2) SIGNAGE REQUIRED AT ALL DOORS FOR | | | ENTRANCE THROUGH STORAGE RMS TO | | | ELECTRICAL ROOMS. SIGNAGE SHALL INCLUDE | | | WORDING. "CLEAR PATH OF EGRESS TO ALL | | | ELECTRICAL ROOMS SHALL BE MAINTAINED AT | | | ALL TIMES" OR WORDS TO THAT EFFECT. | | | MIN 1" LTRS ON CONTRASTING BACK AND | | | SIGNAGE SHALL BE PERMANANTLY AFFIXED. | | | | | | 3) SIGNAGE REQUIRED FOR ALL MAINS AND DISCONNECTING | | | MEANS. | | | 230.2E,700.8,701.9 | | | | | | | | | *********************************** | | | | | | FIRE PUMP SUBMITTIALS STAMPED AND | | | INSERTED INTO SPEC BOOKS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-04-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-18 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-17 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2006-04-18 00:00:00 | *** UNSAT *** | | | | | | 1) NOTE: PELASE SUBMIT THE MANUFACTURES | | | SPECS/CUT SHEETS FOR FIRE PUMP AND FIRE | | | PUMP CONTROLLER. THIS WAS REQUESTED ON | | | THE TWO PREVIOUS REVIEWS AND THE | | | RESPONSE LTR MENTIONS THESE ARE TO BE | | | SUBMITTED, HOWEVER THESE COULD NOT BE | | | LOCATED ON PACKAGE. | | | THESE ARE NEED TO VERIFY COMPLIANCE FOR | | | LOCKED ROTOR SETTING FOR MAX OCP , THE | | | MEANS OF DISCONNECT REQUIRED PER NFPA-20 | | | CHAPTERS 6 AND 7, (1999)7-3.6, 7-4.2 AND | | | NFPA-70.695.5, 230.76,230.79 | | | | | | 2) NOTE: PLEASE SEE THAT ALL ELECTRICAL | | | SHEETS ARE SIGNED, DATED AND SEALED AS | | | REQUIRED PER FS 471.025 | | | PLEASE SEE NEW SHEETS ARE SIGNED, DATED | | | AND SEALED AND MANY OF THE OTHER SHEETS | | | ARE NOT DATED. | | | PLEASE SEE PLANS MUST BE RE-SEALED AS | | | THE SEAL AS SHOWN IS NO LONGER | | | ACCEPTABLE AS PUBLIC RECORD FOR THE | | | FLORIDA BOARD OF PROFESSINAL ENGINEER'S. | | | PLEASE SEE FAC 61G15-23.001 WHICH IN FEB | | | 04 CHANGED TO NOW REQUIRE ALL SEALS TO | | | CONTAIN THE WORDING OF "LICENSE" AND | | | COULD NO LONGER USE "CERTIFICATE". | | | PLEASE KNOW, AN EXTENSION WAS GRANTED TO | | | THE DATE OF 12/31/05 TO GIVE ALL | | | ENGINEERS 2 YRS TO OBTAIN NEW SEALS. WE | | | CAN NO LONGER ACCEPT OLD SEALS. | | | PLEASE SEE PREVIOUS SHEETS WERE NOT | | | DATED. | | | | | | ** PLEASE SEE THE FOLLOWING IS A NEW | | | COMMENT AND CAN BE SET UP AS A "PROVISO" | | | WHICH WOULD REQUIRE REVISIONS BEFORE | | | ROUGH OR MAY BE ADDRESSED AT THIS TIME | | | SINCE PLANS ARE COMING BACK FOR COMMENTS | | | AND COMMENTS FROM OTHER TRADES. | | | | | | 1) NOTE: PLEASE SEE NFPA-101 (2003) | | | 7.8.1.3 AND 7.9.2.2 WHICH REQUIRES AMIN | | | OF 10FT CANDLE (108LUX) IN STAIR TOWERS. | | | | | | PLEASE ALSO KNOW A MIN OF ONE BATTERY | | | BACK UP FIXTURE ON EVERY OTHER LEVEL | | | MEETING THE MIN OF 1FT CANDLE UNDER | | | EMERGENCY CONDITIONS WILL BE REQUIRED. | | | PLEASE PROVIDE PHOTO-METRICS FOR STAIRS | | | WALKING SURFACE. PLEASE KNOW, THIS CAN | | | BE A TYPICAL DETAIL AS EACH STAIR TOWER | | | AND FLOOR LEVEL IS THE SAME. | | | PLEASE KNOW, THE BATTERY BACK UP FIXTURE | | | ON EVERY OTHER LEVEL AT A MIN IS | | | REQUIRED DUE THE POSSIBLE TRIPPING IS | | | DISCONNECTING OF A SINGLE MEANS OF OCP | | | AND WOULD LEAVE STAIR TOWERS IN TOTAL | | | DARKNESS. | | | PLEASE SEE THE CORRIDORS ARE ONLY | | | REQUIRED TO MEET 1 FT CANDLE UNDER | | | NORMAL AND EMERGENCY CONDITIONS. | | | A BATTERY BACK UP FIXTURE MEETING THE | | | MIN FT CANDLES WILL BE REQUIRED IN THE | | | EGRESS PATH. | | | ** PLEASE KNOW, THIS WAS NOT IN PREVIOUS | | | COMMENTS FROM ELECTRICAL REVIEW, HOWEVER | | | THE NEW REQUIREMENTS OF THE 2003 LS101 | | | WAS ADOPTED BY THE STATE OF FLORIDA ON | | | JAN 1ST, 2005. | | | ** AS MENTIONED ABOVE THIS CAN BE DONE | | | AT THIS TIME OR A "PROVISO" BEFORE FIRST | | | ROUGH INSPECTION CAN BE SET UP. | | | IF THERE ARE ANY QUESTIONS ON THIS, | | | PLEASE CALL. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2006-04-17 00:00:00 | REVIEW COMMENCED, | | 2006-04-13 00:00:00 | IN ELECTRICAL FOR REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-14 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-11-14 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2005-11-14 00:00:00 | *** UNSAT *** | | | | | | PLEASE SEE SOME COMMENTS FROM PREVIOUS | | | REVIEW AND SOME NEW COMMENTS DUE TO | | | INFORMATION NOW SUBMITTED AND/OR CHANGES | | | IN DESIGN. | | | | | | 1)NOTE: PLEASE SEE NO INFORMATION WAS | | | SUBMITTED FOR FIRE PUMP WITH FIRE PUMP | | | CONTROLLER. PLEASE SEE RISER DIAGRAM | | | DOES NOT INCLUDE HP RATING OF PUMP IN | | | ORDER TO VERIFY FEEDERS/SEC'S ETC. | | | SPECS NOT SPECIFIC TO ANY ONE SIZE. | | | PLEASE ALSO SUBMIT SPECS FOR PUMP, THE | | | MANUFACTURE CUT SHEETS. | | | | | | 2)NOTE: PLEASE SEE NEC NFPA-70, | | | 701.11(B)3, WHICH REQUIRES ADDITIONAL | | | "ON-SITE" FUEL SOURCE WHEN RELYING ON | | | THE UTILITY COMPANY ONLY FOR FUEL. | | | PLEASE SUBMIT SPECS/ CUT SHEETS FOR | | | "ON-SITE" TANK, LP). PLEASE SEE FIRE | | | REVIEW COMMENTS FOR SIZING OF THE TANK | | | AND WHETHER OR NOT THE SIZE MAY REQUIRE | | | TANK TO BE DIRECTLY BURIED IN THE | | | GROUND. | | | | | | 3)NOTE: PLEASE SEE RESPONSE LETTER | | | MENTIONS CORRECTIONS MADE TO PLANS FOR | | | GFI PROTECTION FOR ALL KITCHEN CIRCUITS | | | 15AND 20A AND 120V. PER 2002 NEC 210.8B3 | | | COULD NOT LOCATE THIS. | | | | | | 4)NOTE: PLEASE SEE EEP AND ELP WILL BE | | | REQUIRED TO HAVE MCB'S AS SPECS FOR ATS | | | SWITCH SUBMITTED FOR BOTH UNITS DOES NOT | | | CONTAIN AN MANUAL MEANS OF DISCONNECT | | | LOCATED ON THE OUTSIDE OF THE ATS FOR | | | DISCONNECTING FEEDERS COMING INTO | | | BUILDING FROM GEN. | | | 225.31,225.34. | | | PLEASE ALSO VERIFY IF THE SPECS FOR | | | ATS'S SUBMITTED IS FOR BOTH. | | | ** PLEASE KNOW, IT IS KNOW THAT SPEC | | | BOOKS SUBMITTED DOES CONTAIN A NOTE FOR | | | MANUAL MEANS OF DISCONNECT, HOWEVER THE | | | MANUFACTURE SPECS/CUT SHEETS DID NOT | | | MATHC WITH THIS. | | | | | | 5)NOTEL PLEASE SEE P1B AS THIS IS A 225A | | | MLO WITH 300A OCP FEEDING THIS PANEL. | | | | | | 6)NOTE: PLEASE SEE SOME CIRCUITS STILL | | | SHOWN AS 30A OCP ON #12 AWG, PLEASE SEE | | | MOST WERE CORRECTED ON PREVIOUS REVIEW. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-05-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-09 |
Time |
06:30 |
Rev Time |
8.00 |
| Received By |
dpalmer |
Date |
2005-05-04 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2005-05-09 00:00:00 | ********* UNSAT ********* | | | | | | HAWTHORNE SUITES 6- STORY HOTEL | | | | | | 1)NOTE: PLEASE SEE MISSING LICENSE | | | INFORMATIONREQUIRED ON TITLE BLOCKS | | | PER FAC 61G1-16.004 FOR ARCHITECT'S AND | | | ARCHITECTUAL FIRMS. PLEASE ALSO SEE FAC | | | 61G15-23.002 FOR ENGINEERS AND | | | ENGINEERING FIRMS. | | | PLEASE SEE FS 481.219 AND FS 471.023. | | | | | | 2)NOTE: PLEASE SEE LS 101 5-9 FOR | | | CIRCUITING OF EM LIGHTING. PLEASE SEE | | | STAIRS AND HALL WILL REQUIRE TWO CIRUITS | | | FROM EM PANEL OR BATTERY BACK-UP | | | FIXTURES WILL BE REQUIRED. | | | | | | 3)NOTE: PLEASE VERIFY EM LTS REQUIRED IN | | | ELEVATOR EQUIPMENT RMS AND ELECTRICAL | | | RMS. LS 101 5-9 | | | | | | 4)NOTE: PLEASE SEE NOTE #28 ON | | | ELECTRICAL EQUIPMENT SCHEDULE. PLEASE | | | SEE 695.4B1, THE OVERCURRENT PROTECTIVE | | | DEVICE(S) SHALL BE SELECTED OR SET TO | | | CARRY INDEFINITELY THE SUM OF THE | | | LOCKED-ROTOR CURRENT OF THE FIRE PUMP | | | MOTOR(S) AND THE PRESSURE MAINTENANCE | | | PUMP MOTOR(S) AND THE FULL-LOAD CURRENT | | | OF THE ASSOCIATED FIRE PUMP ACCESSORY | | | EQUIPMENT WHEN CONNECTED TO THIS POWER | | | SUPPLY. PLEASE SEE 300A IS SHOWN FOR | | | LOCKED ROTOR EXCEEDING. | | | PLEASE ALSO SEE LOCATION OF FIRE PUMP | | | DISCONNECT/ SERVICE MEANS SHALL BE | | | REMOTE FROM MAIN ELECTRICAL SERVICE. | | | PLEASE SEE NEC 2002 695.3 COMMENTARY | | | THE POWER SOURCE FOR AN ELECTRIC | | | MOTOR-DRIVEN FIRE PUMP MUST BE RELIABLE | | | AND HAVE ADEQUATE CAPACITY TO CARRY THE | | | LOCKED-ROTOR CURRENTS OF THE FIRE PUMP | | | MOTOR AND ACCESSORY EQUIPMENT. THESE TWO | | | MAIN REQUIREMENTS ENSURE THAT THE FIRE | | | PUMP WILL OPERATE IN THE EVENT OF A FIRE | | | WITHOUT BEING ACCIDENTALLY DISCONNECTED | | | AND THAT THE FIRE PUMP WILL CONTINUE TO | | | OPERATE UNTIL THE FIRE IS EXTINGUISHED, | | | THE FIRE PUMP IS PURPOSELY SHUT DOWN, OR | | | THE PUMP ITSELF IS DESTROYED. | | | PLEASE SEE FOLLOWING COMMENTS FOR | | | REQUESTED INFORAMTION INCLUDING FIRE | | | PUMP INFORMATION. | | | PLEASE SEE FIRE PUMP IS SHOWN HAVING TWO | | | FEEDS FROM THE MAIN SWITCH BOARD?? | | | | | | 5)NOTE: PLEASE SEE ELECTRICAL PANELS / | | | OCP NOT PERMITTED IN STORAGE AREAS AND | | | AREAS WITH EASILY IGNITIBLE MATERIALS. | | | PLEASE SEE 110.26,408.7 240.24D | | | PLEASE SEE THESE AREAS SHALL BE | | | DEDICATED TO ELECTRICAL EQUIPMENT. | | | | | | 6)NOTE:PLEASE SEE DISCONNECTING MEANS | | | REQUIRED FOR FEEDS FROM GENERATOR TO BE | | | LOCATED AT MAIN BLDG/ ELECTRICAL RMS. | | | PLEASE SEE 225.31-36. | | | | | | 7)NOTE: PLEASE SEE GENERATOR APPEARS TO | | | BE A SEPARATELY DERIVED SYSTEM. PLEASE | | | SEE NOTES TO ELECTRICAL RISER DIAGRAM | | | APPEARS TO SHOW TRANSFER SWITCH(S) AS | | | 4-POLE?? | | | PLEASE SEE 250.30 FOR SYSTEM SEPARATELY | | | DERIVED. | | | PLEASE SEE ALSO SEE 250.24,250.6 FOR | | | GROUNDING/EQUIPMENT GROUNDING. | | | | | | 8)NOTE: PLEASE SEE NOTES TO RISER | | | DIAGRAM #15 AND #16 ARE LEFT BLANK? | | | HOWEVER, PLEASE SEE THESE #'S ARE USED | | | ON RISER. | | | | | | 9)NOTE: PLEASE SEE FIRE PUMP DISC IS | | | SHOWN BEING CONNECTED TO MAIN SERVICE | | | EQUIPMENT. PLEASE SEE 695.4 THIS IS NOT | | | PERMITTED. FIRE PUMP DISCONNECTING MEANS | | | SHALL BE DIRECTLY CONNECTED TO UTILITY | | | SERVICE. FPL. | | | | | | 10)NOTE: PLEASE VERIFY OF MSB HAS A MCB | | | WITH A MANUAL MEANS OF DISCONNECT | | | LOCATED ON THE OUTSIDE OF EQUIPMENT. | | | PLEASE SEE 230.76,230.79 | | | | | | 11)NOTE: PLEASE CORRELATE OCP SHOWN ON | | | MSWBD WITH RATINGS OF PANELS. PLEASE SEE | | | SOME PANELS ARE SHOWN WITH 400A OCP AND | | | PANELS ARE RATED AT 225A'S. | | | PLEASE SEE 100A OCP FEEDING PANELS RATED | | | AT 400A'S. PLEASE SEE THIS IS OK, | | | HOWEVER ITEMS ON PANEL APPEAR TO HAVE | | | LOAD EXCEEDING THE 100'S. | | | THIS CAN NOT BE VERIFIED AT THIS TIME | | | DUE TO LOAD CALCS NOT BEING SHOWN ON | | | EACH PANEL. | | | | | | 12)NOTE: PLEASE SEE 250.104 FOR OTHER | | | METAL PIPES REQUIRED. (FIRE PUMP) ETC. | | | | | | 13)NOTE: PLEASE PROVIDE LOAD ON EACH | | | PANEL SCHEDULE PER NEC 220,215.5 | | | | | | 14)NOTE: PLEASE SHOW ALL CONTINUOUS | | | LOADS AND LARGEST MOTORS LOADS @ 125%. | | | PLEASE SEE LIGHTING ETC. 215.3,230.42 | | | ETC. | | | | | | 15)NOTE: PLEASE SEE NOE FEEDERS | | | SHOWN/NOTED FOR PD1. 215.5,310.16,240.4 | | | | | | 16)NOTE: PLEASE SEE NO PANEL SCHEDULE | | | WAS PROVIDED FOR PANEL "PP". | | | 215.5 | | | | | | 17)NOTE: PLEASE SEE PANEL H3P IS ALSO | | | SHOWN AS HP3? | | | PLEASE CORRELATE. | | | | | | 18)NOTE: PLEASE SEE FIRE PUMP IS NOT | | | SHOWN BEING FED FROM THE GENERATOR? | | | PLEASE SEE TWO MEANS OF POWER SHALL BE | | | SUPPLIED FOR BLDG'S EXCEEDING | | | 75'/HIGH-RISE. IF BLDG DOES NOT EXCEED | | | 75', A DIRECT CONNECTION TO FPL MAY BE | | | ACCEAPTED AS A RELIABLE SOURCE. | | | | | | 19)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH PANEL | | | SCHEDULES. PLEASE ALSO SEE TYPICAL | | | SUITES SHALL REQUIRE THIS ALSO. | | | | | | 20)NOTE: PLEASE SEE NOTE #28 ON | | | EQUIPMENT SCHEDULE MENTIONS THAT | | | PLUMBING CONTRACTOR IS TO SUPPLY AND | | | INSTALL FIRE PUMP, FIRE PUMP | | | CONTROLLER/DISCONNECT ETC. | | | PLEASE SEE STATE OF FLORIDA ECLB SCOPE | | | OF WORK PERMITTED UNDER PLUMB | | | CONTRACTORSA LICENSE DOES NOT PERMIT PC, | | | TO INSTALL ELECTRICAL EQUIPMENT. PELASE | | | ADJUST NOTES. | | | | | | 21)NOTE: PLEASE SEE NUMEROUS PANEL | | | SCHEDULES WHICH INDICATE 30A OCP ON #12 | | | AWG? | | | PLEASE SEE 310.16 AND 240.4 FOR MIN | | | SIZING REQUIRED. | | | | | | 22)NOTE: PLEASE SEE WIND LOADING IS | | | REQUIRED FOR SITE LIGHTING POLES AND | | | FIXTURES. THIS IS REQUIRED AT THIS TIME | | | IF SHOWN ON PLANS. | | | WIND LOADING IS @ 140MPH PER FBC. | | | | | | 23)NOTE: : PLEASE SEE EEP IS BEING FED | | | WITH A 100A OCP FROM GEN? HOWEVER THIS | | | IS BEING FED WITH 400A OCP FROM MSWBD? | | | | | | 24)NOTE: PLEASE SEE NOTES TO RISER | | | DIAGRAM MENTIONS 9-4" CONDUITS TO MAINS, | | | HOWEVER CONDUCTORS FOR THESE CONDUITS | | | COULD NOT BE LOCATED? | | | PLEASE SEE 240.4,310.16 | | | 215.5 | | | | | | 25)NOTE: PLEASE PROVIDE ALL MANUFACTURE | | | SPEC/CUT SHEETS FOR FIRE PUMP, FIRE PUMP | | | CONTROLLER, ATS'S SWITCHES, GENERATOR | | | ETC. PLEASE ALSO PROVIDE INFORMATION FOR | | | GEN. PRIME MOVER. IF A SUB-BASE FUEL | | | TANK, PLEASE PROVIDE MANUFACT SHEETS. | | | | | | 26)NOTE: PLEASE SEE NEC 2002 210.8B3 FOR | | | GFI PROTECTION REQUIRED IN KITCHEN/ | | | SERVING AREAS. PLEASE ALSO SEE EMPLOYEE | | | KITCHEN. | | | | | | 27)NOTE: PLEASE SEE POSSIBLE COMMENTS | | | FROM OTHER REVIEWER(S) WHICH MAY HAVE AN | | | AFFECT ON ELECTRICAL PLANS. | | | | | | 28)NOTE: PLEASE SEE DUE TO MISSING | | | INFORMATION A COMPLETE REVIEW FOR CODE | | | COMPLIANCE CAN NOT BE DONE AT THIS TIME. | | | PLEASE BE SURE TO PROVIDE ALL | | | INFORMATION AS REQUESTED ABOVE. | | | | | | ***PLEASE BE SURE TO REMOVE OLD/VOIDED | | | SHEETS FROM SETS AND ONLY INSERT NEW | | | REVISED SHEETS INTO THREE COMPLETE SETS | | | FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | 2005-05-06 00:00:00 | NOTES TO FOLLOW UPON COMPLETION OF | | | REVIEW. | | | PLANS WILL BE IN THE FAILED STATUS ONCE | | | THESE NOTES ARE COMPLETE. | | | 5/6/05 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2006-10-19 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-10-19 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-10-19 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2006-10-19 09:19:41 | NO COMMENTS 10/19/06 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2005-10-12 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-10-12 |
Time |
10:39 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-10-12 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-05-10 |
Time |
10:20 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-05-10 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2005-05-10 00:00:00 | FAILED: | | | | | | 1. PLEASE SUBMIT THE FINAL CIVIL PLANS | | | AS APPROVED BY THE PUBLIC UTILIRIES AND | | | ENGINEERING FOR ALL THE CONNECTIONS TO | | | THE SERVICES. | | | 2. PLEASE SUBMIT A COPY OF SITE | | | ASSESSMENT STUDY REPORT AND REMEDIAL | | | ACTION PLANS IF ANY. | | | 3. PLEASE NOTE THAT POLLUTION PREVENTION | | | PLANS MUST BE INCLUDED IN CIVIL PLANS. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
8 |
Status |
F |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-06-02 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-06-02 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2008-06-02 15:52:56 | ***DENIED*** | | | | | | 1) PLEASE SEE MECHANICAL COMMENT #1 REGARDING DISTANCE | | | FROM STORAGE TANK TO PROPERTY LINE. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
F |
Date |
2008-05-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-05-14 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-05-14 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2008-05-14 16:12:14 | *****PROVISO***** | | | | | | | | | 1.THE ACTUAL ADDRESS OF THE PROJECT SITE SHALL BE | | | SHOWN IN THE TITLE BLOCK OF EACH SUBMITTED PLAN SHEET. | | | NO ADDRESS SHOWN ON SHEETS MSP1, MSP2, AND E-16;THE | | | INCORRECT ADDRESS IS SHOWN ON SHEET SK-6. | | | | | | 2.PLEASE ADDRESS ELECTRICAL PLAN REVIEW COMMENT. | | | | | | | | | THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN | | | THE ABOVE COMMENTS HAVE BEEN ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
N |
Date |
2008-04-16 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-04-16 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-04-16 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2008-04-16 17:05:35 | *****REVIEWED***** | | | | | | | | | REVIEWED SHEETS MSP1 & MSP2, FH-C2, AND PD-C1;THE | | | SCOPE OF REVISIONS HAVE NO OR VERY LITTLE BEARING ON | | | LIFE SAFETY. | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2008-03-26 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-03-26 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-03-26 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2008-03-26 15:32:28 | REVISED SHEETS FA-1- FA-7. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-02-22 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-02-22 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2008-02-22 15:49:03 | *****DENIED***** | | | | | | | | | AS PER BATTALLION CHIEF/FIRE MARSHAL MIKE CARSILLO, THE | | | SUBMITTED PLAN SHEETS WILL NOT BE ACCEPTED WITH | | | HAND-DRAWN, INK, OR WHITE/BLACK OUTED MARKINGS. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-01-24 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-01-24 |
Time |
15:00 |
Sent To |
M |
|
| Notes |
| 2007-01-24 15:06:48 | ***PROVISO*** | | | | | | 1) LAUNDRY CHUTE SHOP DRAWINGS SUBMITTED FOR REVIEW OK | | | PROVIDED THAT REQUIRED FIRE PROTECTION SYSTEM IS NOT | | | ALTERED OR NEGATIVELY IMPACTED REGARDING INTENT OF | | | DESIGN. | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | (561) 805-6722 OR 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-11-16 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-11-16 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2005-11-16 00:00:00 | ******PROVISO****** | | | | | | THANK YOU FOR YOUR WELL ADDRESSED | | | RESPONSES. ALTHOUGH ITEMS #14-20 AND | | | #23-24 ARE INFORMATIONAL, AN | | | ACKNOWLEDGMENT WOULD BE APPRECIATED. | | | PLANS WILL BE STAMPED WHEN RETURNED FOR | | | OTHER REVIEW COMMENTS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-05-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-05-31 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-31 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2005-05-31 00:00:00 | ****DENIED**** | | | | | | 1) ALL LIFE SAFETY SHALL BE IN | | | ACCORDANCE WITH NFPA 101, 2003 EDITION. | | | | | | 2) CHAPTER 26 OF NFPA 101 IS REFERENCED | | | IN REGARDS TO OCCUPANT CLASSIFICATION, | | | HOWEVER CHAPTER 28 SHOULD BE USED. | | | | | | 3) TACTILE SIGNS ARE REQUIRED AT EXITS. | | | | | | 4) PLEASE CLARIFY THE OCCUPANT LOAD FOR | | | THE HAWTHORN ROOM AND EXPLAIN EXITING. | | | | | | 5) WHAT IS THE SEPARATION BETWEEN THE | | | ELECTRIC ROOM AND THE HC SUITE ON THE | | | FIRST FLOOR? | | | | | | 6) SIGNAGE IS REQUIRED WITHIN THE STAIR | | | ENCLOSURES INDICATING THE TOP, BOTTOM, | | | FLOOR NUMBER AND ROOF ACCESS. | | | | | | 7) IT APPEARS THAT AN ADDITIONAL EXIT | | | SIGN MAY BE REQUIRED AT THE 6TH FLOOR | | | CORRIDOR LEADING TO STAIR #1. | | | | | | 8) THE DOOR TO THE FOOD SERVICE ROOM | | | WHEN OPEN, APPEARS TO OBSTRUCT THE | | | CORRIDOR BY GREATER THAN 1/2 THE WIDTH. | | | | | | 9) THE ELEVATOR LOBBIES ABOVE THE LEVEL | | | OF EXIT DISCHARGE, ARE REQUIRED TO BE | | | SEPARATED FROM THE REMAINDER OF THE | | | BUILDING. | | | | | | 10) WHAT IMPACT WILL THE CARD READERS | | | HAVE ON EXITING? | | | | | | 11) AN ADDRESS NUMBER AT LEAST 6" IN | | | HEIGHT AND CONTRASTING TO THE | | | BACKGROUND, WILL BE REQUIRED ON THE | | | BUILDING. | | | | | | 12) PLEASE PROVIDE THE PRESCRIPTIVE | | | STRENGTH REQUIREMENTS OF ALL HANDRAILS | | | AND GUARDRAILS. | | | | | | 13) PANIC HARDWARE IS REQUIRED ON DOORS | | | SERVING AN OCCUPANT LOAD OF MORE THAT | | | 100 PERSONS. | | | | | | 14) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR THE FIRE SPRINKLER AND | | | FIRE ALARM SYSTEMS. | | | | | | 15) NEW FIRE ALARM SYSTEMS SUPERVISING A | | | SPRINKLER SYSTEM SHALL BE MONITORED BY | | | UL CERTIFIED CENTRAL STATION SERVICE. | | | | | | 16) A CHAIN AND LOCK SHALL BE PROVIDED | | | ON THE DOUBLE CHECK DETECTOR ASSEMBLY IN | | | ADDITION TO ELECTRONIC SUPERVISION. | | | | | | 17) PLEASE SEE ELECTRICAL COMMENTS IN | | | REGARDS TO THE FIRE PUMP REQUIREMENTS. | | | | | | 18) SMOKE DETECTORS WIRED TO THE FIRE | | | ALARM SYSTEM ARE REQUIRED IN THE | | | CORRIDORS AND OTHER COMMON AREAS. SINGLE | | | STATION SMOKE DETECTORS ARE REQUIRED IN | | | LIVING UNITS. | | | | | | 19) DUCT SMOKE DETECTORS WHERE PROVIDED, | | | ARE TO MEET LOCAL REQUIREMENTS OF | | | INITIATING A GENERAL FIRE ALARM, AND NOT | | | SUPERVISORY SIGNAL. | | | | | | 20) TEMPORARY STANDPIPES SHALL BE | | | PROVIDED WHEN THE BUILDING REACHES 3 | | | STORIES OR 30' IN HEIGHT. | | | | | | 21) PLEASE ILLUSTRATE IF ELEVATORS ARE | | | STRETCHER ACCESSIBLE. | | | | | | 22) A KNOX BOX WILL BE REQUIRED NEAR THE | | | FRONT ENTRANCE. | | | | | | 23) LOCKING KNOX BOX CAPS SHALL BE | | | PROVIDED FOR THE FIRE DEPARTMENT | | | CONNECTION. | | | | | | 24) FIRE DEPARTMENT CONNECTION SHALL BE | | | LOCATED NO FURTHER THAN 150' FROM THE | | | CLOSEST FIRE HYDRANT. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2951 OR 805-6722 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
10 |
Status |
P |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-05-02 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-05-02 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2008-05-02 11:13:57 | REVISION OK - SHT P-08 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
9 |
Status |
P |
Date |
2008-03-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-03-26 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-03-26 |
Time |
13:13 |
Sent To |
PC |
|
| Notes |
| 2008-03-26 13:15:29 | REVISION SHEET P-08: "OK" NEW GAS RISER W/2 PSI | | | DELIVERY PRESSURE AND MP REGULATORS. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
8 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-22 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-22 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2008-02-22 14:32:44 | REVISIONDENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. SHT P-08 GAS RISER DIAGRAM 2-1/2" REQUIRED FROM THE | | | METER AND UP TO THE BRANCH LINE FOR THE GAS DRYERS. | | | TABLE 402(8).--POOL/BATH HOUSE GAS RISER DIAGRAM | | | DOES NOT REFLECT THE GAS RISER DIAGRAM AT THE METER. | | | SHOW ALL CUT LENGTHS FOR THE POOL HEATER GAS LINES FROM | | | WHERE IT CONNECTS TO THE MAIN GAS RISER DIAGRAM.-- | | | INDICATE REGULATOR MODEL NUMBERS FOR THE GAS DRYERS, | | | THE HOT WATER BOOSTER, POOL HEATER AND THE RTU'S 1, 2 & | | | 3. | | | ****RESPONSE NOTED, BUT THE RISER DIAGRAM STILL SHOWS | | | 2" PIPE UP TO THE BRANCH LINE FOR THE GAS DRYERS. THERE | | | WAS NO RESPONSE TO THE RISER DIAGRAM FOR THE POOL/BATH | | | RISER NOT REFLECTING THE GASE RISER AT THE METER AND | | | ALL CUT SECTIONS WERE NOT PROVIDED.--REGULATOR | | | MODELS INDICATED FOR RTU'S 1 & 2 ARE NOT APPROVED. | | | MAXIMUM 140 MBH FOR THE MODEL 325-3L, BUT 150 MBH | | | INDICATED ON THE RISER DIAGRAM. | | | | | | ****FROM PREVIOUS PLUMBING REVIEW: | | | | | | 5. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2.-- THE | | | MANUF. SHEETS FOR THE POOL HEATER SHALL | | | BE SUBMITTED. | | | ****RESPONSE NOTED, BUT THE DRYER MANUF SHEETS ARE NOT | | | APPROVED. THERE IS NO LISTING INDICATED ON THE MANUF. | | | SHEETS.NO BTU LOAD INDICATED. COVER SHEET STATES | | | "REFER TO PAGE 4 FOR MODEL IDENTIFICATION". PAGE 4 HAS | | | NOT BEEN SUBMITTED WITH MANUF. SPECIFICATION SHEETS. | | | --NO MANUF. SHEETS FOR RTU UNITS 1 & 2 SUBMITTED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
7 |
Status |
F |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-01-17 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-01-17 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2008-01-17 12:08:52 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | 1. SHT P-08 GAS RISER DIAGRAM 2-1/2" REQUIRED FROM THE | | | METER AND UP TO THE BRANCH LINE FOR THE GAS DRYERS. | | | TABLE 402(8).--POOL/BATH HOUSE GAS RISER DIAGRAM | | | DOES NOT REFLECT THE GAS RISER DIAGRAM AT THE METER. | | | SHOW ALL CUT LENGTHS FOR THE POOL HEATER GAS LINES FROM | | | WHERE IT CONNECTS TO THE MAIN GAS RISER DIAGRAM.-- | | | INDICATE REGULATOR MODEL NUMBERS FOR THE GAS DRYERS, | | | THE HOT WATER BOOSTER, POOL HEATER AND THE RTU'S 1, 2 & | | | 3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
6 |
Status |
P |
Date |
2007-11-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-11-13 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-11-13 |
Time |
11:37 |
Sent To |
B1 |
|
| Notes |
| 2007-11-13 11:38:06 | ENERGY CALCULATIONS FOR THE WATER HEATERS APPROVED. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
F |
Date |
2007-10-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-15 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-15 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2007-10-15 14:33:13 | SEE COMMENTS FROM REVIEW FOR SHT P-08 DATED 10-13-07: | | | | | | | | | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE.--COMPLETE ISOMETRIC NOT SUBMITTED. | | | SUBMIT A COMPLETE ISOMETRIC WITH THE PIPING FOR THE | | | POOL HOUSE WATER HEATER SHOWN WITH ALL CUT SECTIONS AND | | | CORRESPONDING LENGHTS.--INDICATE THE MODEL OF EACH | | | REGULATOR ON THE ISOMETRIC. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED.--NOT | | | INDICATED FOR POOL HOUSE WATER HEATER. | | | | | | 3. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33).--POOL HOUSE WATER HEATER NOT INDICATED. | | | | | | 4. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4).--TO BE VERIFIED ONCE | | | RESPONSE FOR COMMENT IS REVIEWED. | | | | | | 5. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2.--POOL HOUSE WATER | | | HEATER MANUF. SHEETS REQUIRED. | | | | | | 6. SUBMIT THE MANUF. SPECIFICATION SHEETS FOR ALL | | | REGULATORS. INDICATED MODEL NUMBER USED FOR EACH | | | REGULATOR AND INDICATE WHERE EACH REGULATOR MODEL WILL | | | BE USED TO VERIFY CAPACITY. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2007-10-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-13 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-13 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2007-10-13 10:43:34 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE.--COMPLETE ISOMETRIC NOT SUBMITTED. | | | SUBMIT A COMPLETE ISOMETRIC WITH THE PIPING FOR THE | | | POOL HOUSE WATER HEATER SHOWN WITH ALL CUT SECTIONS AND | | | CORRESPONDING LENGHTS.--INDICATE THE MODEL OF EACH | | | REGULATOR ON THE ISOMETRIC. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED.--NOT | | | INDICATED FOR POOL HOUSE WATER HEATER. | | | | | | 3. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33).--POOL HOUSE WATER HEATER NOT INDICATED. | | | | | | 4. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4).--TO BE VERIFIED ONCE | | | RESPONSE FOR COMMENT IS REVIEWED. | | | | | | 5. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2.--POOL HOUSE WATER | | | HEATER MANUF. SHEETS REQUIRED. | | | | | | 6. SUBMIT THE MANUF. SPECIFICATION SHEETS FOR ALL | | | REGULATORS. INDICATED MODEL NUMBER USED FOR EACH | | | REGULATOR AND INDICATE WHERE EACH REGULATOR MODEL WILL | | | BE USED TO VERIFY CAPACITY. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2007-09-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-05 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-04 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2007-09-05 12:54:56 | REVISION DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | 1. SHT P-08 GAS RISER ISOMETRIC DIAGRAM. THE GAS | | | REGULATORS FOR THE DOMESTIC WATER BOILERS ARE NOT | | | APPROVED. THE MAXIMUM INDIVIDUAL LOAD FOR THE MAXITROL | | | MODEL 325-51 IS ONLY 250,000 BTU'S. THE RISER DIAGRAM | | | INDICATES 400,000 BTU'S FOR EACH BOILER. (SEE ATTACHED | | | SHEET). PLEASE SPECIFY THE CORRECT REGULATORS FOR THE | | | BOILERS. SECTION 410.2(1). (ALSO CORRECT REGULATOR | | | MODEL NUMBER ON DETAIL FOR WATER HEATERS SHEET P-07). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-06-19 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-06-19 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2007-06-19 07:56:13 | REVISION OK - SHT P-02A--REVISION REQUIRED FOR GAS | | | RISER DIAGRAM TO REFLECT THE CHANGES INDICATED ON THE | | | FLOOR PLAN. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2006-08-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-31 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-12 |
Time |
18:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
76 |
Status |
N |
Date |
2008-05-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-14 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-14 |
Time |
09:11 |
Sent To |
E |
|
| Notes |
| 2008-05-14 09:11:40 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
75 |
Status |
N |
Date |
2008-04-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-29 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-29 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2008-04-29 11:42:48 | TO "COMM" BD#12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
74 |
Status |
N |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-22 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-22 |
Time |
11:50 |
Sent To |
P |
|
| Notes |
| 2008-04-22 11:51:09 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
73 |
Status |
N |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-17 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-17 |
Time |
15:41 |
Sent To |
E |
|
| Notes |
| 2008-04-17 15:42:11 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
72 |
Status |
N |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-04 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-04 |
Time |
16:18 |
Sent To |
Z |
|
| Notes |
| 2008-04-04 16:19:29 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
71 |
Status |
N |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-04 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-04 |
Time |
16:16 |
Sent To |
Z |
|
| Notes |
| 2008-04-04 16:17:13 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
70 |
Status |
N |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-04 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-04 |
Time |
16:12 |
Sent To |
E |
|
| Notes |
| 2008-04-04 16:12:19 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
69 |
Status |
N |
Date |
2008-03-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-26 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-26 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2008-03-26 10:12:28 | TO "COMM" BD#14 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
68 |
Status |
N |
Date |
2008-03-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-26 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-26 |
Time |
10:00 |
Sent To |
Z |
|
| Notes |
| 2008-03-26 10:00:41 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
67 |
Status |
N |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-25 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-25 |
Time |
08:41 |
Sent To |
G |
|
| Notes |
| 2008-03-25 08:43:09 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
66 |
Status |
N |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-07 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-07 |
Time |
10:51 |
Sent To |
FIRE |
|
| Notes |
| 2008-03-07 10:51:49 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
65 |
Status |
N |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-07 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-07 |
Time |
10:45 |
Sent To |
M |
|
| Notes |
| 2008-03-07 10:46:14 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
64 |
Status |
N |
Date |
2008-02-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-01 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-01 |
Time |
14:44 |
Sent To |
P |
|
| Notes |
| 2008-02-01 14:44:41 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
63 |
Status |
N |
Date |
2008-01-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-28 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-28 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2008-01-28 09:25:58 | TO "F" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
62 |
Status |
N |
Date |
2007-12-26 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-12-26 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-12-26 |
Time |
09:58 |
Sent To |
P |
|
| Notes |
| 2007-12-26 09:58:29 | SENT TO KEN STEVEN'S DESK MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
61 |
Status |
N |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-19 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-19 |
Time |
09:44 |
Sent To |
E |
|
| Notes |
| 2007-11-19 09:45:56 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
60 |
Status |
N |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-16 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-16 |
Time |
14:53 |
Sent To |
B |
|
| Notes |
| 2007-11-16 14:53:55 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
59 |
Status |
N |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-07 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-07 |
Time |
11:29 |
Sent To |
B |
|
| Notes |
| 2007-11-07 11:29:48 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
58 |
Status |
N |
Date |
2007-10-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-24 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-24 |
Time |
10:54 |
Sent To |
E |
|
| Notes |
| 2007-10-24 10:54:34 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
57 |
Status |
N |
Date |
2007-10-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-17 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-17 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2007-11-05 10:11:23 | TO "COMM" BD#13 | | 2007-10-17 10:51:23 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
56 |
Status |
N |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-25 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-25 |
Time |
09:50 |
Sent To |
E |
|
| Notes |
| 2007-09-25 09:50:48 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
55 |
Status |
N |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-25 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-25 |
Time |
09:31 |
Sent To |
B |
|
| Notes |
| 2007-09-25 09:31:57 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
54 |
Status |
N |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-25 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-25 |
Time |
09:27 |
Sent To |
M |
|
| Notes |
| 2007-09-25 09:27:47 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
53 |
Status |
N |
Date |
2007-09-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-13 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-13 |
Time |
10:54 |
Sent To |
B |
|
| Notes |
| 2007-09-13 10:54:33 | TO "JWITMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
52 |
Status |
N |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-10 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-10 |
Time |
10:42 |
Sent To |
B |
|
| Notes |
| 2007-09-10 10:43:31 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
51 |
Status |
N |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-28 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-28 |
Time |
16:11 |
Sent To |
P |
|
| Notes |
| 2007-08-28 16:12:13 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
50 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-21 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-21 |
Time |
09:53 |
Sent To |
E |
|
| Notes |
| 2007-08-21 09:53:24 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
49 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-21 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-21 |
Time |
09:40 |
Sent To |
E |
|
| Notes |
| 2007-08-21 09:40:56 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
48 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-21 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-21 |
Time |
09:38 |
Sent To |
B |
|
| Notes |
| 2007-08-21 09:38:33 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
47 |
Status |
N |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-16 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-16 |
Time |
08:25 |
Sent To |
E |
|
| Notes |
| 2007-08-16 08:26:02 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
46 |
Status |
N |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-16 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-16 |
Time |
08:19 |
Sent To |
B |
|
| Notes |
| 2007-08-16 08:20:12 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
45 |
Status |
N |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-16 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-16 |
Time |
08:15 |
Sent To |
M |
|
| Notes |
| 2007-08-16 08:15:30 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
44 |
Status |
N |
Date |
2007-07-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-27 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-27 |
Time |
16:08 |
Sent To |
B |
|
| Notes |
| 2007-07-27 16:08:32 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
43 |
Status |
N |
Date |
2007-07-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-24 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-24 |
Time |
14:01 |
Sent To |
M |
|
| Notes |
| 2007-07-24 14:02:04 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
42 |
Status |
N |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-18 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-18 |
Time |
16:51 |
Sent To |
E |
|
| Notes |
| 2007-07-18 16:51:32 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
41 |
Status |
N |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-18 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-18 |
Time |
16:49 |
Sent To |
B |
|
| Notes |
| 2007-07-18 16:49:48 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
40 |
Status |
N |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-18 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-18 |
Time |
16:45 |
Sent To |
P |
|
| Notes |
| 2007-07-18 16:46:13 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
39 |
Status |
N |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-06 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-06 |
Time |
10:51 |
Sent To |
E |
|
| Notes |
| 2007-07-06 10:52:06 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
38 |
Status |
N |
Date |
2007-07-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-05 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-05 |
Time |
09:04 |
Sent To |
E |
|
| Notes |
| 2007-07-05 09:04:34 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
37 |
Status |
N |
Date |
2007-06-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-29 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-29 |
Time |
16:50 |
Sent To |
M |
|
| Notes |
| 2007-06-29 16:50:49 | TO"M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
36 |
Status |
N |
Date |
2007-06-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-29 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-29 |
Time |
16:35 |
Sent To |
B |
|
| Notes |
| 2007-06-29 16:35:49 | TO "JWITMER' DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
35 |
Status |
N |
Date |
2007-06-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-22 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-22 |
Time |
16:18 |
Sent To |
B |
|
| Notes |
| 2007-06-22 16:18:59 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
34 |
Status |
N |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-20 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-20 |
Time |
14:32 |
Sent To |
B |
|
| Notes |
| 2007-06-20 14:33:01 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
33 |
Status |
N |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-20 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-20 |
Time |
14:29 |
Sent To |
B |
|
| Notes |
| 2007-06-20 14:29:28 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
32 |
Status |
N |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-20 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-20 |
Time |
14:28 |
Sent To |
B |
|
| Notes |
| 2007-06-20 14:28:52 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
31 |
Status |
N |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-20 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-20 |
Time |
14:28 |
Sent To |
B |
|
| Notes |
| 2007-06-20 14:28:10 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
30 |
Status |
N |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-20 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-20 |
Time |
14:27 |
Sent To |
B |
|
| Notes |
| 2007-06-20 14:27:39 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
29 |
Status |
N |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-20 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-20 |
Time |
14:26 |
Sent To |
B |
|
| Notes |
| 2007-06-20 14:26:55 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
28 |
Status |
N |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-13 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-13 |
Time |
14:26 |
Sent To |
B |
|
| Notes |
| 2007-06-13 14:27:04 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
27 |
Status |
N |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-13 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-13 |
Time |
14:25 |
Sent To |
B |
|
| Notes |
| 2007-06-13 14:25:57 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
26 |
Status |
N |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-23 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-23 |
Time |
08:55 |
Sent To |
E |
|
| Notes |
| 2007-05-23 08:55:37 | TO "E" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
25 |
Status |
N |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-23 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-23 |
Time |
08:53 |
Sent To |
P |
|
| Notes |
| 2007-05-23 08:54:07 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2007-05-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-22 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-22 |
Time |
16:41 |
Sent To |
M |
|
| Notes |
| 2007-05-22 16:41:27 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-16 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-16 |
Time |
09:58 |
Sent To |
I |
|
| Notes |
| 2007-05-16 09:59:16 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2007-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-02 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-02 |
Time |
09:32 |
Sent To |
B |
|
| Notes |
| 2007-05-02 09:32:56 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2007-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-02 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-02 |
Time |
08:54 |
Sent To |
B |
|
| Notes |
| 2007-05-02 08:54:58 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2007-04-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-13 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-13 |
Time |
14:53 |
Sent To |
B |
|
| Notes |
| 2007-04-13 14:54:01 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2007-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-12 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-12 |
Time |
09:42 |
Sent To |
B |
|
| Notes |
| 2007-04-12 09:42:39 | TO "JWITMER' DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-14 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-14 |
Time |
11:22 |
Sent To |
B |
|
| Notes |
| 2007-03-14 11:23:18 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-08 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-08 |
Time |
15:58 |
Sent To |
B |
|
| Notes |
| 2007-03-08 15:59:12 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-08 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-08 |
Time |
11:10 |
Sent To |
B |
|
| Notes |
| 2007-03-08 11:13:22 | TO "JWITMER" DESK/3 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-21 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-21 |
Time |
08:40 |
Sent To |
B |
|
| Notes |
| 2007-02-21 08:40:22 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-15 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-15 |
Time |
13:24 |
Sent To |
B |
|
| Notes |
| 2007-02-15 13:24:45 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-22 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-22 |
Time |
09:34 |
Sent To |
B |
|
| Notes |
| 2007-01-22 09:34:43 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-10 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-10 |
Time |
09:18 |
Sent To |
FIRE |
|
| Notes |
| 2007-01-10 09:18:36 | TO "F" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-12-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-26 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-26 |
Time |
09:13 |
Sent To |
B |
|
| Notes |
| 2006-12-26 09:14:28 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
|
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2006-11-29 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2006-11-29 |
Time |
18:59 |
Sent To |
B |
|
| Notes |
| 2006-11-29 18:59:30 | SENT TO JIM WITMER'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
|
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2006-11-29 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2006-11-29 |
Time |
19:00 |
Sent To |
B |
|
| Notes |
| 2006-11-29 18:57:45 | SENT TO JIM WITMER'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-11-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-04 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-04 |
Time |
16:10 |
Sent To |
B |
|
| Notes |
| 2006-11-04 16:10:58 | TO "JWITMER" DESK/ 2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-10-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-19 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-19 |
Time |
10:17 |
Sent To |
B |
|
| Notes |
| 2006-10-19 10:18:09 | TO "JWITMER" DESK/ 2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-14 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-14 |
Time |
16:36 |
Sent To |
B |
|
| Notes |
| 2006-10-14 16:36:34 | TO "JWITMER" DESK/3 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-11 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-11 |
Time |
09:12 |
Sent To |
ENG |
|
| Notes |
| 2006-10-11 09:13:27 | TO "ENG" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-07-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-14 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-14 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2006-07-14 00:00:00 | TO "COMM" BD#30/PLANS ON RACK/4 ROLLS | | | AND BINDERS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-09 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-09 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2006-04-06 00:00:00 | TO "COMM" BD#43 | | 2006-03-14 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-30 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-30 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2005-10-06 00:00:00 | TO "COMM" BD#18/PLANS ON RACK 4 ROLLS | | | AND BINDERS | | 2005-09-30 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-16 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-05-02 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2005-05-02 00:00:00 | TO "COMM" BD#13/PLANS ON RACK, 3 ROLLS |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2008-04-08 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
RKUSSNER |
Date |
2008-04-08 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2008-04-08 17:20:26 | LANDSCAPING: **** PASSED WITH PROVISO *** | | | | | | SEE ZONING NOTES:CONTACT ROBERT KUSSNER FOR | | | LANDSCAPING COMMENTS. | | | | | | | | | ROBERT KUSSNER | | | LANDSCAPE PLANNER | | | TEL (561) 822-1462 | | | | | | PLANNING AND ZONING: **** PASSED WITH THE PROVISO THAT | | | THE MINOR AMENDMENT NOTED ON COMM. #2 IS APPROVED BY | | | THE PLANNING AND ZONING DEPT. PRIOR TO FINAL | | | CERTIFICATE OF OCCUPANCY ("CO").**** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | | | 2. THIS PERMIT IS PART OF AN APPLICATION UNDER REVIEW | | | FOR A MINOR AMENDMENT (PB1402F) TO THE COURTNEY LAKES | | | RESIDENTIAL PLANNED DEVELOPMENT (RPD), HAWTHORN SUITES | | | HOTEL.SIGN-OFF FROM THE PLANNING AND ZONING DEPT. FOR | | | THE FINAL CO. IS CONTINGENT UPON THE APPROVAL OF THE | | | MINOR AMENDMENT.THE DRAWINGS SHALL REFLECT ALL | | | REVISIONS PERTAINING TO LANDSCAPING, RE-LOCATION OF THE | | | COMPACT SPACES, SCREENING OF THE GENERATOR AND | | | MECHANICAL EQUIPMENT ON ROOF-TOP, INCLUDING DETAILS. | | | PROVIDE ALL SHEETS INCLUDING, BUT NOT LIMITED TO MSP 1 | | | AND 2, PD/SHEET C1, FH/SHEET C2 AND LANDSCAPING SHEETS | | | (LA-1 AND LA-2) THAT ARE PART OF PERMIT NUMBER. | | | 05041760 - "RE-SUBMITTAL TO GO WITH ENGINEERING | | | DRAWINGS" (RECEIVED ON APRIL 4, 2008) UNDER COMMENTS | | | COVER FORM (THE WEITZ CO.). | | | *** NOTE: ADDRESS ALL LANDSCAPING COMMENTS FROM ROBERT | | | KUSSNER. | | | | | | 3.THE BOLLARD(S) NEED TO BE RELOCATED/RECONFIGURED | | | OUT OF THE PARKING SPACE LOCATED NEXT TO THE LARGE | | | GENERATOR. | | | | | | 4.LANDSCAPING PLANS - LABEL COMPACT SPACES ON | | | LANDSCAPE PLANS AS NOTED ON SITE PLANS (SHEETS MSP1 AND | | | MSP2). | | | | | | 5.SHEET MSP2 OF 2 - LOCATION OF HANDICAP SYMBOL'S | | | LOWER-END SHALL BE TWO (2) FEET FROM THE PARKING STRIPE | | | DETAIL INSTEAD OF FOUR (4) FEET SIX (6) INCHES. | | | | | | 6.PROVIDE AN ENLARGED DETAIL OF THE HOTEL SITE PLAN | | | AREA FOR THE DIMENSIONS, ETC. TO BE LEGIBLE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME AT THE | | | NUMBER BELOW. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2008-03-27 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-03-27 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-03-27 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2008-03-27 16:02:31 | MUST PROCESS THE MINOR AMENDMENT WHICH WILL INCLUDE ALL | | | CHANGES TO SITE AND LANDSCAPE PLANS PRIOR TO APPROVAL | | | OF PERMIT. | | | REFER TO PREVIOUS INSPECTION COMMENTS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
15 |
Status |
P |
Date |
2008-07-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-07-16 |
Time |
10:36 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2008-07-16 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2008-07-16 10:38:25 | RECIVED SUBMITTAL SHOWING GENERATOR FUEL TANK 10.9 FEET | | | FROM PROPERTY LINE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
14 |
Status |
F |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-02 |
Time |
14:25 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-06-02 |
Time |
14:25 |
Sent To |
FIRE |
|
| Notes |
| 2008-06-02 15:03:29 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | | | | 1) IT HAS BEEN BROUGHT TO MY ATTENTION THAT THE FUEL | | | STORAGE TANK FOR THE GENERATOR IS 550 GAL. DIESEL FUEL. | | | PER NFPA 30 TABLE 4.3.2.1.1 (B), THE STORAGE TANK MUST | | | BE 10 FEET FROM THE PROPERTY LINE. PLEASE SUBMIT | | | DOCUMENTATION SHOWING THE DISTANCE BETWEEN THE FUEL | | | STORAGE TANK AND THE PROPERTY LINE. | | | | | | 2) PLEASE SUBMIT DOCUMENTATION STATING THE SIZE OF THE | | | GENERATOR'S FUEL STORAGE TANK AND TYPE OF FUEL. PER | | | 2004 FBC 106.3, 106.4, AND 106.5. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
13 |
Status |
P |
Date |
2008-03-20 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-03-20 |
Time |
19:25 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-03-20 |
Time |
19:25 |
Sent To |
|
|
| Notes |
| 2008-03-20 19:27:02 | TEST & BALANCE REPORT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
12 |
Status |
P |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-28 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-28 |
Time |
17:53 |
Sent To |
B |
|
| Notes |
| 2007-11-28 17:54:11 | REVISED ENERGY CALCULATIONS DATED 11/13/07 MECH OK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
11 |
Status |
P |
Date |
2007-11-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-05 |
Time |
14:23 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-11-05 |
Time |
14:23 |
Sent To |
P |
|
| Notes |
| 2007-11-05 14:25:09 | SUBMITTED ENERGY CALCULATIONS FORM 400A-2001 (2001 FBC) |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
10 |
Status |
F |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-26 |
Time |
10:29 |
Rev Time |
2.00 |
| Received By |
tgordon |
Date |
2007-09-26 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2007-09-26 11:05:10 | PLAN REVIEW UNDER THE 2001 FLORIDA BUILDING CODE & | | | REFERENCED CODES, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | *** DENIED *** | | | THE FOLLOWING COMMENTS MAY HAVE BEEN PROVISO-ED IN | | | PREVIOUS REVIEWS BUT REVISED MECHANICAL PLANS STILL DO | | | NOT SHOW COMPLIANCE WITH 2001 FBC/M 607.1.2 OR | | | EXCEPTIONS 607.1.3. | | | | | | 1) REVISED MECHANICAL PLAN PAGE M-03 SHOWS A 22" X 10" | | | SUPPLY AIR DUCT PENETRATING TWO 1 HOUR FIRE RATED WALLS | | | TO THE ELECTRICAL ROOM #120, THE DUCTS WILL NEED FIRE | | | DAMPERS, SEE 2001 FBC/M 607.1.2. | | | | | | 2) REVISED MECHANICAL PLAN PAGE M-04 SHOWS A 12" X 8" | | | SUPPLY AIR DUCT PENETRATING A ONE HOUR FIRE RATED WALL | | | FROM STORAGE ROOM #228 TO CORRIDOR #223, AND A 8" X 6" | | | DUCT FROM STORAGE ROOM #213 TO CORRIDOR #223, THE DUCTS | | | WILL NEED A FIRE DAMPERS, SEE 2001 FBC/M 607.1.2. | | | | | | 3) REVISED MECHANICAL PLAN PAGE M-05 SHOWS A 12" X 15" | | | SUPPLY AIR DUCT PENETRATING A ONE HOUR FIRE RATED WALL | | | FROM STORAGE ROOM #623 TO MULTIPURPOSE ROOM #621, THE | | | DUCT WILL NEED A FIRE DAMPER, SEE 2001 FBC/M 607.1.2. | | | | | | 4) REVISED MECHANICAL PLAN PAGE M-02 PASSED REVIEW AND | | | WAS STAMPED. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2007-08-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-17 |
Time |
08:23 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-08-17 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2007-08-17 08:23:48 | MECH. REVISION PAGE M-04. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2007-07-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-25 |
Time |
10:39 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-07-25 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2007-07-25 10:46:34 | ** MECHANICAL REVISION TO PLANS PAGES M-03, M-04, AND | | | M-05. | | | *** PROVISO *** | | | 1) 2001 FBC/M 504.7 COMMERCIAL CLOTHES DRYERS. | | | THE INSTALLATION OF DRYER EXHAUST DUCTS SERVING TYPE 2 | | | CLOTHES DRYERS SHALL COMPLY WITH THE APPLIANCE | | | MANUFACTURER?S INSTALLATION INSTRUCTIONS. EXHAUST FAN | | | MOTORS INSTALLED IN EXHAUST SYSTEMS SHALL BE LOCATED | | | OUTSIDE OF THE AIRSTREAM. IN MULTIPLE INSTALLATIONS, | | | THE FAN SHALL OPERATE CONTINUOUSLY OR BE INTERLOCKED TO | | | OPERATE WHEN ANY INDIVIDUAL UNIT IS OPERATING. DUCTS | | | SHALL HAVE A MINIMUM CLEARANCE OF 6 INCHES (152 MM) TO | | | COMBUSTIBLE MATERIALS. CLOTHES DRYER TRANSITION DUCTS | | | USED TO CONNECT THE APPLIANCE TO THE EXHAUST DUCT | | | SYSTEM SHALL BE LIMITED TO SINGLE LENGTHS NOT TO EXCEED | | | 8 FEET (2438 MM) IN LENGTH AND SHALL BE LISTED AND | | | LABELED FOR THE APPLICATION. TRANSITION DUCTS SHALL NOT | | | BE CONCEALED WITHIN CONSTRUCTION. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-03 |
Time |
11:07 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-07-03 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2007-07-03 11:15:33 | REVISION TO MECH. PLANS PAGES M-04, M-05 AND M-06. | | | | | | *** PROVISO *** | | | 1) FRESH AIR INTAKE TO COMPLY WITH 2004 FBC/M 401.5.1 | | | INTAKE OPENINGS. | | | MECHANICAL AND GRAVITY OUTSIDE AIR INTAKE OPENINGS | | | SHALL BE LOCATED A MINIMUM OF 10 FEET (3048 MM) FROM | | | ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | | AND LOADING DOCKS, EXCEPT AS OTHERWISE SPECIFIED IN | | | THIS CODE. FRESH AIR INTAKES SHALL NOT BE LOCATED | | | CLOSER THAN 10 FEET (3048 MM) FROM ANY CHIMNEY OR VENT | | | OUTLET, OR SANITARY SEWER VENT OUTLET. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-23 |
Time |
12:13 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2007-05-23 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2007-05-23 12:15:22 | REVISION TO MECH. PLANS PAGES M-03, M-04, M-06, AND | | | M-07. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-19 |
Time |
15:58 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-03-19 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2007-03-19 15:59:23 | REVISION TO MECHANICAL PLANS PAGES M-02, M-04, M-05, | | | AND M-06. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-09-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-09-06 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-09-06 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2006-09-06 00:00:00 | PROVISO: | | | PER RESPONSE LETTER DATED JUNE 19, 2006 | | | THE FOLLOWING ITEMS WILL BE REVISED | | | AFTER PERMIT IS ISSUED. | | | | | | PLAN SHEET M-04 8 X 4 DUCT PENETRATING | | | STORAGE ROOM 213 & 228, DUCT SHALL | | | COMPLY WITH 2001 FMC 607.1.3 #3 ITEMS 1 | | | THROUGH 4. | | | | | | PER 2001 FBC 705.2.4.6, AUTOMATIC | | | SPRINKLERS - AN APPROVED AUTOMATIC | | | SPRINKLER SYSTEM SHALL BE INSTALLED AT | | | THE TOP AND AT ALTERNATE FLOOR LEVELS IN | | | REFUSE AND LAUNDRY CHUTES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719 OR | | | E-MAIL [email protected]. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-06-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-06-04 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-06-04 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2006-06-04 00:00:00 | DENIED: | | | COMMENT FROM REVIEW DATED | | | PLANS ARE TO BE DATED IN ACCORDANCE WITH | | | FS 471.025 & FAC 61G15-23.002 (2) | | | SIGNATURE AND DATE SHALL BE LOCATED ON | | | SEAL.PLEASE NOTE, PLANS REVISED AND | | | SUBMITTED AFTER JANUARY 1,2006 THE SEAL | | | SHALL INDICATE "LICENSE" NUMBER NOT | | | "CERTIFICATE" NUMBER. | | | | | | PROVISO: | | | PLAN SHEET M-04 8 X 4 DUCT PENETRATING | | | STORAGE ROOM 213 & 228, DUCT SHALL | | | COMPLY WITH 2001 FMC 607.1.3 #3 ITEMS 1 | | | THROUGH 4. | | | | | | PER 2001 FBC 705.2.4.6, AUTOMATIC | | | SPRINKLERS - AN APPROVED AUTOMATIC | | | SPRINKLER SYSTEM SHALL BE INSTALLED AT | | | THE TOP AND AT ALTERNATE FLOOR LEVELS IN | | | REFUSE AND LAUNDRY CHUTES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719 OR | | | E-MAIL [email protected]. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-12-07 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-12-07 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2005-12-07 00:00:00 | DENIED: | | | PLEASE CLARIFY THE FOLLOWING RESPONSES | | | TO 2ND REVIEW (1ST REVIEW DATE 6/16/05): | | | | | | COMMENT #2 - RESPONSE INDICATES BIRD | | | SCREEN REMOVED FROM DRYER VENTS.PER | | | 2001 FMC 504.4, DRYER EXHAUST IS TO BE | | | EQUIPPED WITH A BACKDRAFT DAMPER. | | | | | | COMMENT #3 & 1 - PLEASE PROVIDE | | | SUBMITTAL FOR THE COMMERCIAL GAS DRYERS | | | & EXHAUST FANS.APPROVAL CANNOT BE | | | GIVEN WITHOUT MANUFACTURER'S SUBMITTAL & | | | INSTALLATION DATA FOR EQUIPMENT & | | | APPLIANCES. | | | | | | PLEASE NOTE, PLANS ARE TO BE DATED IN | | | ACCORDANCE WITH FS 471.025 & FAC | | | 61G15-23.002 (2). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-16 |
Time |
13:58 |
Rev Time |
6.50 |
| Received By |
pkrauss |
Date |
2005-06-16 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2005-06-16 00:00:00 | DENIED: | | | 1.SUBMITTAL BOOK DOES NOT INCLUDE | | | SUBMITTAL DATA FOR MECHANICAL EQUIPMENT; | | | RTU'S, SPLIT SYSTEMS, EXHAUST FANS | | | DRYERS, ETC. | | | | | | 2.PLAN SHEET M-02 FAN SCHEDULE - FAN | | | #7 &8 ARE INDICATED FOR DRYERS. THE | | | "REMARK" COLOUM IT INDICATES #4 A | | | BIRDSCREEN.PER 2001 FBC(M)504.4, | | | SCREENS SHALL NOT BE INSTALLEDAT DUCT | | | TERMINATION. | | | | | | 3.PLAN SHEET M-03, GUEST LAUNDRY - | | | 2001 FBC(M)504.6 DOESNOT ALLOW FOR | | | IN-LINE FANS IN THE DRYER EXHAUST DUCT. | | | IS THIS APPLICATION PERMITTED BY THE | | | DRYER MANUFACTURER?COMMERCIAL LAUNDRY | | | ROOM - 2001 FBC(M) 504.7, EXHAUST FAN | | | MOTORS SHALL BE LOCATED OUTSIDE THE | | | AIRSTREAM. IN MULTIPLE INSTALLATIONS THE | | | FAN SHALL RUN CONTINUOUSLY OR BE | | | INTERLOCKED TO RUN WHEN ANY INDIVIDUAL | | | UNIT IS RUNNING. | | | | | | 4.PLEASE NOTE, PER 2001 FBC(M)504.2 | | | CLOTHES DRYER EXHAUST DUCTS SHALL NOTE | | | PENETRATE OR TERMINATE WITHIN ANY FIRE | | | BLOCKING OR ANY FIRE RATED ASSEMBLY | | | UNLESS DUCT IS CONSTRUCTED OF GALVENIZED | | | OR ALUMINUM AS SPECIFIED IN TABLE 603.3. | | | | | | 5.EXHAUST SHALL NOT BE DIRECTED ONTO | | | WALK-WAYS, OR TERMINATE IN A MANNER THAT | | | CREATES A NUISANCE. 2001 FBC(M) 401.5.2. | | | | | | 6.OUTSIDE AIR INTAKES SHALL BE LOCATED | | | A MINIMUM OF 10 FT FORM ANY NOXIOUS | | | CONTAMINANT, PARKING LOTS, AND LOADING | | | DOCKS.2001 FBC(M)401.5.1 | | | | | | 7.PLAN SHEET M-04, CLARIFY LOCATION OF | | | TW-2.IT APPEARS TO BE IN A CLOSET IN | | | BEDROOM 1 & INDICATES 18" X 18" LOUVER | | | DOOR.SHOULD THIS READ GRILLE? | | | RETURN AIR FROM BEDROOM 2 REQUIRED. | | | RETURN FROM BEDROOM 2 SHALL BE SIZED IN | | | ACCORDANCE WITH 2001 FBC(M)601.4. | | | | | | 8.PLAN SHEET M-05 & M-03, INDICATE | | | RETURN AIR PLENUMS IN THE COMMON AREAS. | | | NO COMBUSTIBLES ALLOWED ABOVE THE | | | CEILING IN THE RETURN AIR PLENUM, 2001 | | | FBC(M) 602.2.1. | | | | | | 9.PLAN SHEET M-07 NOTE #1, PLEASE NOTE | | | AUXILIARY DRAIN PAN SHALL HAVE OVERFLOW | | | ROTECTION.PLEASE INDICATE WHICH METHOD | | | WILL BE USED AS SPECIFIED IN 307.2.3. | | | | | | 10.PLEASE PROVIDE OUSTIDE AIR | | | CALUCALTIONS FOR ALL AREAS PER 2001 | | | FBC(M) TABLE 403.3. | | | | | | 11.PLEASE CLARIFY SMOKE CONTROL (IF | | | ANY).PROVIDE SEQUENCE OF OPERATION. | | | | | | 12. PROVIDE DETAIL FOR THE CONDESING | | | UNIT STANDS LOCATED ON THE ROOF. HEIGHT | | | FROM THE ROOF SURFACE TO THE BOTTOM OF | | | THE SUPPORT RAIL SHALL BE IN ACCORDANCE | | | WITH 2001 FBC 1511.7.PROVIDE DETAIL | | | FOR SECURING UNITS. | | | | | | IF YOU HAVE ANY QUESTIONSS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
13 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-22 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-22 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2008-02-22 14:30:47 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 FUEL GAS | | | | | | 1. OK | | | 2. OK | | | | | | 3. SHT P-08 GAS RISER DIAGRAM 2-1/2" REQUIRED FROM THE | | | METER AND UP TO THE BRANCH LINE FOR THE GAS DRYERS. | | | TABLE 402(8).--POOL/BATH HOUSE GAS RISER DIAGRAM | | | DOES NOT REFLECT THE GAS RISER DIAGRAM AT THE METER. | | | SHOW ALL CUT LENGTHS FOR THE POOL HEATER GAS LINES FROM | | | WHERE IT CONNECTS TO THE MAIN GAS RISER DIAGRAM.-- | | | INDICATE REGULATOR MODEL NUMBERS FOR THE GAS DRYERS, | | | THE HOT WATER BOOSTER, POOL HEATER AND THE RTU'S 1, 2 & | | | 3. | | | ****RESPONSE NOTED, BUT THE RISER DIAGRAM STILL SHOWS | | | 2" PIPE UP TO THE BRANCH LINE FOR THE GAS DRYERS. THERE | | | WAS NO RESPONSE TO THE RISER DIAGRAM FOR THE POOL/BATH | | | RISER NOT REFLECTING THE GAS RISER AT THE METER AND ALL | | | CUT SECTIONS WERE NOT PROVIDED.--REGULATOR MODELS | | | INDICATED FOR RTU'S 1 & 2 ARE NOT APPROVED. MAXIMUM 140 | | | MBH FOR THE MODEL 325-3L, BUT 150 MBH INDICATED ON THE | | | RISER DIAGRAM. | | | | | | 4. SHT P-08 REVISION HISTORY ON STAMPED/REVIEWED SHEET | | | INDICATES REVISIONS 2 & 3. THESE HAVE BEEN DELETED FROM | | | THE REVISION HISTORY.--NEW REVISIONS THIS SUBMITTAL | | | INDICATE REVISIONS 5, 7 & 8, BUT ONLY REVISION 8 HAS | | | BEEN LOCATED. PLEASE INDICATE WHERE REVISIONS 5 & 7 CAN | | | BE FOUND. SHOW THE COMPLETE REVISION HISTORY ON THE | | | REVISION INDEX. SECTION 104.2.1.3. | | | ****RESPONSE NOTED, BUT THE SHEET ON FILE AND REVIEWED | | | SHOWS REVISION 2, DATED 1-13-06, AND REVISION 3, DATED | | | 6-12-06. PLEASE SHOW COMPLETE REVISION HISTORY ON THE | | | REVISION INDEX. SECTION 104.2.1.3. | | | | | | 5. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2.-- THE | | | MANUF. SHEETS FOR THE POOL HEATER SHALL | | | BE SUBMITTED. | | | ****RESPONSE NOTED, BUT THE DRYER MANUF SHEETS ARE NOT | | | APPROVED. THERE IS NO LISTING INDICATED ON THE MANUF. | | | SHEETS.NO BTU LOAD INDICATED. COVER SHEET STATES | | | "REFER TO PAGE 4 FOR MODEL IDENTIFICATION". PAGE 4 HAS | | | NOT BEEN SUBMITTED WITH MANUF. SPECIFICATION SHEETS. -- | | | NO MANUF. SHEETS FOR THE RTU UNITS1 & 2 SUBMITTED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
12 |
Status |
P |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-22 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-22 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2008-02-22 14:18:36 | REVISIONS OK--SHTS P-05A, P-05B & P-06 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
11 |
Status |
F |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-01-17 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-01-16 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2008-01-17 12:06:39 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 FUEL GAS | | | | | | 1. SHTS P-05A, P-O5B & P-06 PER SECTION 1107.3 THE | | | CROSS-SECTIONAL AREA OF AN OVERFLOW SCUPPER SHALL BE | | | THREE TIMES THE CROSS-SECTIONAL AREA OF THE PRIMARY | | | ROOF DRAIN AND THE SCUPPER SHALL HAVE A MINIMUM OPENING | | | DIMENSION OF 4 INCHES. | | | | | | 2. SHTS P-05A, P-05B & P-06 PER SECTION 1503.4.2 | | | OVERFLOW SCUPPERS SHALL HAVE A MINIMUM OPENING | | | DIMENSION OF 4 INCHES IN HEIGHT AND SHALL BE PLACED IN | | | WALLS OR PARAPETS WITH THE INLET FLOW LINE NOT LESS | | | THAN 2 INCHES ABOVE THE ROOF SURFACE, EXCLUDING SUMPS, | | | OR MORE THAN 4 INCHES ABOVE THE ROOF SURFACE AND SHALL | | | BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED VERTICAL | | | LEADERS. EACH VERTICAL LEADER SHALL BE SUPPLIED WITH AN | | | EMERGENCY OVERFLOW SCUPPER SIZED PER SECTION 1107.3 OF | | | THE PLUMBING CODE. | | | | | | 3. SHT P-08 GAS RISER DIAGRAM 2-1/2" REQUIRED FROM THE | | | METER AND UP TO THE BRANCH LINE FOR THE GAS DRYERS. | | | TABLE 402(8).--POOL/BATH HOUSE GAS RISER DIAGRAM | | | DOES NOT REFLECT THE GAS RISER DIAGRAM AT THE METER. | | | SHOW ALL CUT LENGTHS FOR THE POOL HEATER GAS LINES FROM | | | WHERE IT CONNECTS TO THE MAIN GAS RISER DIAGRAM.-- | | | INDICATE REGULATOR MODEL NUMBERS FOR THE GAS DRYERS, | | | THE HOT WATER BOOSTER, POOL HEATER AND THE RTU'S 1, 2 & | | | 3. | | | | | | 4. SHT P-08 REVISION HISTORY ON STAMPED/REVIEWED SHEET | | | INDICATES REVISIONS 2 & 3. THESE HAVE BEEN DELETED FROM | | | THE REVISION HISTORY.--NEW REVISIONS THIS SUBMITTAL | | | INDICATE REVISIONS 5, 7 & 8, BUT ONLY REVISION 8 HAS | | | BEEN LOCATED. PLEASE INDICATE WHERE REVISIONS 5 & 7 CAN | | | BE FOUND. SHOW THE COMPLETE REVISION HISTORY ON THE | | | REVISION INDEX. SECTION 10104.2.1.3. | | | | | | 5. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2.-- THE | | | MANUF. SHEETS FOR THE POOL HEATER SHALL | | | BE SUBMITTED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
10 |
Status |
F |
Date |
2007-10-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-15 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-15 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2007-10-15 14:44:50 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | | | | A. SHT P-02C REVISION #5 DATED 07/11/07 & REVISION #6 | | | DATED 07/22/07 WERE APPROVED PREVIOUSLY. NO | | | CHANGE/REVISION NOTED. SHEET NOT APPROVED. | | | | | | B. SHT P-06 THE ROOF DRAINAGE AREA SHOWN DOES NOT | | | APPEAR TO BE CORRECT. SEE PREVIOUS REVISION COMMENTS | | | FOR THIS SHEET. NO CALCULATIONS WERE SUBMITTED, AND NO | | | INFORMATION FOR THE SCUPPERS AS REQUESTED. (SEE | | | FOLLOWING FROM PREVIOUS REVIEW DATED 09/05/07): | | | | | | (5). SHT P-06 INDICATES A ROOF DRAIN ON WHAT APPEARS TO | | | BE A HIP ROOF. PLEASE CLARIFY.--SUBMIT A DETAIL FOR | | | THE ROOF DRAIN CONNECTION TO THE PEAK OF THE ROOF. -- | | | SUBMIT CALCULATIONS FOR THE PRIMARY AND SECONDARY ROOF | | | DRAINS, (IF ROOF HAS A PARAPET) PER SECTIONS 1106 & | | | 1107 WITH ALL SUBSECTIONS & TABLES. SHOW THE SQUARE | | | FOOTAGE OF THE ROOF AND 1/2 AREA OF ALL VERTICAL WALLS | | | INCLUDING PARAPETS ADDED TO THE ROOF AREA IN THE | | | CALCULATIONS.--ROOF DRAIN IS NOT SHOWN ON THE | | | STORM DRAIN TABLE. PLEASE CLARIFY. SECTION 104.2.1.-- | | | SHOW THE LOCATION OF ALL SECONDARY ROOF DRAINS OR | | | EMERGENCY ROOF SCUPPERS. SECTION 104.2.1.--NOTE ON | | | PLANS STATES "FOR RELIEF SCUPPER DRAINS SEE ARCH. | | | DRAWINGS". PLEASE INDICATE WHERE IN THE ARCHITECTURAL | | | DRAWINGS THESE CAN BE FOUND. SECTION 104.2.1.-- | | | PLEASE RESPOND TO ALL OF THIS AFTER AND INCLUDING | | | "SUBMIT CALCULATIONS..... | | | | | | C. SHT P-08 SEE THE FOLLOWING COMMENTS FROM 10/13/07 | | | FOR THE GAS ISOMETRIC RISER DIAGRAM: | | | | | | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE.--COMPLETE ISOMETRIC NOT SUBMITTED. | | | SUBMIT A COMPLETE ISOMETRIC WITH THE PIPING FOR THE | | | POOL HOUSE WATER HEATER SHOWN WITH ALL CUT SECTIONS AND | | | CORRESPONDING LENGHTS.--INDICATE THE MODEL OF EACH | | | REGULATOR ON THE ISOMETRIC. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED.--NOT | | | INDICATED FOR POOL HOUSE WATER HEATER. | | | | | | 3. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33).--POOL HOUSE WATER HEATER NOT INDICATED. | | | | | | 4. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4).--TO BE VERIFIED ONCE | | | RESPONSE FOR COMMENT IS REVIEWED. | | | | | | 5. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2.--POOL HOUSE WATER | | | HEATER MANUF. SHEETS REQUIRED. | | | | | | 6. SUBMIT THE MANUF. SPECIFICATION SHEETS FOR ALL | | | REGULATORS. INDICATED MODEL NUMBER USED FOR EACH | | | REGULATOR AND INDICATE WHERE EACH REGULATOR MODEL WILL | | | BE USED TO VERIFY CAPACITY. | | | | | | ****END OF GAS COMMENTS FROM 10-13-07**** | | | | | | D. SHT P-11 NO CHANGE FROM REVISION #4 ON SHEET SEALED | | | 07/06/07. SHEET NOT APPROVED AS THERE ARE NO NEW | | | REVISIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
P |
Date |
2007-10-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-15 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-15 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2007-10-15 14:34:52 | REVISIONS OK--SHTS P-03A, P-04A, P-05A & P-11 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
P |
Date |
2007-10-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-13 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-13 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2007-10-13 10:24:18 | REVISION OK--SHT P-02C CHANGES TO GAS SIZING AND | | | INDICATING NEW LINE TO POOL HOUSE HEATER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2007-09-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-05 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-05 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2007-09-05 14:06:19 | REVISIONS OK--SHTS P-01, P-02A, P-05B & P-11 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2007-09-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-05 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-04 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2007-09-05 12:53:05 | REVISION DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | | | | 1. SHT P-02C REVISION #5 TO BE INDICATED ON ALL | | | REVISIONS ON SHEET. CLOUDS INDICATED, BUT WITHOUT THE | | | REVISION NUMBERS. SECTION 104.2.1.3. | | | | | | 2. SHT P-03A DRAWING NOTES (14) & (15). ICE MACHINE AND | | | FLOOR SINK DELETED FROM THE FLOOR PLAN, BUT NOTES STILL | | | SHOWN. DELETE NOTES ALSO. SECTION 104.2.1. | | | | | | 3. SHT P-04A DRAWING NOTES (14) & (15). ICE MACHINE AND | | | FLOOR SINK DELETED FROM THE FLOOR PLAN, BUT NOTES STILL | | | SHOWN. DELETE NOTES ALSO. SECTION 104.2.1.-- REVISION | | | #5 HAS NOT BEEN LOCATED. MANY REVISIONS INDICATED | | | WITHOUT REVISION NUMBERS. ALL REVISIONS TO BE CLOUDED | | | AND NUMBERED. SECTION 104.2.1.3.--REVISION #4 CLOUD | | | VERY FAINT AND NOT VERY LEGIBLE. DARKEN CLOUDS TO MAKE | | | REVISIONS NOTICIBLE. SECTION 104.2.1.3.-- REVISION #4 | | | SHOWS WATER LINES UP TO A SHOWER, A TUB & LAV, BUT SHT | | | P-05A SHOWS NOT UNIT ABOVE. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | | | | 4. SHT P-05A REVISION INDICATED FOR THE GAS RISER WITH | | | A CLOUD, BUT NO REVISION NUMBER INDICATED. PLEASE CLOUD | | | AND NUMBER ALL REVISIONS. SECTION 104.2.1.3. | | | | | | 5. SHT P-06 INDICATES A ROOF DRAIN ON WHAT APPEARS TO | | | BE A HIP ROOF. PLEASE CLARIFY.--SUBMIT A DETAIL FOR | | | THE ROOF DRAIN CONNECTION TO THE PEAK OF THE ROOF. -- | | | SUBMIT CALCULATIONS FOR THE PRIMARY AND SECONDARY ROOF | | | DRAINS, (IF ROOF HAS A PARAPET) PER SECTIONS 1106 & | | | 1107 WITH ALL SUBSECTIONS & TABLES. SHOW THE SQUARE | | | FOOTAGE OF THE ROOF AND 1/2 AREA OF ALL VERTICAL WALLS | | | INCLUDING PARAPETS ADDED TO THE ROOF AREA IN THE | | | CALCULATIONS.--ROOF DRAIN IS NOT SHOWN ON THE | | | STORM DRAIN TABLE. PLEASE CLARIFY. SECTION 104.2.1.-- | | | SHOW THE LOCATION OF ALL SECONDARY ROOF DRAINS OR | | | EMERGENCY ROOF SCUPPERS. SECTION 104.2.1.--NOTE ON | | | PLANS STATES "FOR RELIEF SCUPPER DRAINS SEE ARCH. | | | DRAWINGS". PLEASE INDICATE WHERE IN THE ARCHITECTURAL | | | DRAWINGS THESE CAN BE FOUND. SECTION 104.2.1. | | | | | | 6. SHT P-08 GAS RISER ISOMETRIC DIAGRAM. THE GAS | | | REGULATORS FOR THE DOMESTIC WATER BOILERS ARE NOT | | | APPROVED. THE MAXIMUM INDIVIDUAL LOAD FOR THE MAXITROL | | | MODEL 325-51 IS ONLY 250,000 BTU'S. THE RISER DIAGRAM | | | INDICATES 400,000 BTU'S FOR EACH BOILER. (SEE ATTACHED | | | SHEET). PLEASE SPECIFY THE CORRECT REGULATORS FOR THE | | | BOILERS. SECTION 410.2(1). (ALSO CORRECT REGULATOR | | | MODEL NUMBER ON DETAIL FOR WATER HEATERS SHEET P-07). | | | | | | 7. SHT P-16 WATER RISER DIAGRAM DOES NOT REFLECT THE | | | FLOOR PLAN. RISER SHOWS 2 TUBS, WHEREAS THE FLOOR PLAN | | | SHOWS ONE TUB. ALSO SEE SHT P-04A THE WATER SUPPLY IS | | | SHOWN IN UNIT 214 WHICH IS RISER W2, BUT THE WATER | | | SUPPLY FOR UNIT ON THE 6TH FLOOR IS SHOWN ON RISER W4 | | | ON THE RISER DIAGRAM. PLEASE CORRELATE. SECTION | | | 104.2.1. | | | | | | 8. NOTE: WHEN SUBMITTING REVISIONS, PLEASE TURN OFF ALL | | | PREVIOUSLY APPROVED REVISION CLOUDS AND REVISION | | | NUMBERS. LEAVING THE PREVIOUS CLOUDS AND REVISION | | | NUMBERS CAUSES CONFUSION AND INCREASES THE TURN AROUND | | | TIME FOR THE REVIEWS. THANK YOU. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-06-19 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-06-18 |
Time |
19:02 |
Sent To |
|
|
| Notes |
| 2007-06-19 07:58:13 | | | | | | | | | | REVISION OK--SHTS P-02A & P-02B--REVISIONS | | | REQUIRED FOR THE GAS, WATER, SANT, OR CONDENSATE RISER | | | DIAGRAMS TO REFLECT THE CHANGES SHOWN ON THE FLOOR | | | PLAN. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-15 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-12 |
Time |
18:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-05-08 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-05-05 |
Time |
18:57 |
Sent To |
|
|
| Notes |
| 2006-05-08 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW: | | | 1. PLANS SHALL BE ROUTED TO DBPR | | | DIVISION OF HOTEL AND RESTURANTS FOR | | | REVIEW. MINIMUM OF 2 STAMPED SETS OF | | | PLANS SHALL BE SUBMITTED TO THE CITY FOR | | | REVIEW WITH 2 PAGE "WORK SHEETS" | | | ATTACHED TO EACH SET. SECTION 101.4.7. - | | | PER RESPONSE SHEET CONTRACTOR WAS | | | SUPPOSED TO DO THIS. NO STAMPED SETS OF | | | PLANS OR WORKSHEETS SUBMITTED. | | | ***RESPONSE NOTED, BUT "SULLIVAN HAS NOT | | | DONE THIS. | | | | | | 4. SHT C-8 CIVIL WATER AND SEWER PLANS. | | | NO WATER SERVICE TO THE BUILDING IS | | | SHOWN. PLEASE INDICATE WATER SERVICE ON | | | PLANS INCLUDING PIPE SIZE, VALVES, | | | BACKFLOW ECT. - SHT C-9 INDICATES A 3" | | | DIP WATER SERVICE, BUT NO BACKFLOW SHOWN | | | FOR WATER SERVICE TO BUILDING. | | | ***RESPONSE NOTED, BUT I CONTACTED MR. | | | DEAN LAUDERMILK FROM WPB ENGINEERING, | | | AND HE ADVISED ME THAT NEW SHEETS, DATED | | | 4-4-06, SHOWING A SEPARATE 8" LINE FOR | | | FIRE AND 4" LINE FOR DOMESTIC WATER WITH | | | A 3" METER ARE SHOWN. PLEASE SUBMIT NEW | | | SHEETS FOR CIVIL WITH NEXT RESUBMITTAL. | | | SECTION 106.1.1. | | | | | | 9. SHT A-6.2 SHOW THE ACCESSIBLE W/C'S | | | TO BE 18" OFF THE WALL TO THE CENTERLINE | | | OF THE FIXTURE, AS REQUIRED IN FIG. 28. | | | - NOT ADDRESSED, ALSO SEE FIG 30E. | | | ***RESPONSE NOTED, MEASUREMENTS FOUND ON | | | SHEETS A-1.1, A-1.4 & A-6.0,BUT THIS IS | | | NOT SHOWN ON ANY OF THE ELEVATIONS ON | | | SHEET A-6.2 AS INDICATED. | | | | | | 10) SHT A-6.2 SHOW THE FOLLOWING FOR THE | | | ACCESSIBLE FIXTURES: | | | FOR W/C'S | | | E. DISPENSERS 11-4.16.6 INDICATE HEIGHT | | | AS REQUIRED. (PLANS SHOW WITHIN REACH) | | | FOR LAVS | | | A. HEIGHT & CLEARANCES 11-4.19.2 - | | | CLEARANCE MEASUREMENT NOT SHOWN. NO | | | CLEARANCE SHOWN AS OF YET. | | | ***RESPONSE NOTED, BUT RESPONSE NOT | | | ADEQUATE. W/C 'C' INDICATES GRAB BARS TO | | | BE 36" MIN. WHEN THEY ARE TO BE 33" TO | | | 36". DETAIL FOR ACCESSIBLETOILET | | | ACCESSORIES INDICATE THAT THE LIP OF THE | | | URINAL TO BE 20". IT IS SUPPOSED TO BE | | | 17" MAX. PLUS SEE NOTES "C" FOR W/C AND | | | "A" FOR LAVS. | | | | | | 12. ALL MECH., ELECT., & PLMB. SHEETS. | | | EACH SHEET OF PLANS WHICH MUST BE SEALED | | | UNDER THE PROVISIONS OF CHAPTER 471 | | | SHALL BE SEALED, SIGNED AND DATED BY THE | | | PROFESSIONAL ENGINEER. 61G15-23.002(1). | | | NO DATE AFFIXED TO SEAL/SIGNATURE. - | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME AND LICENSE NUMBER, AS WELL AS THE | | | NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. 61G15-23.002(2) | | | FAC, & FS 471.025. - THE DATE SEAL AND | | | SIGNATURE SHALL BE PLACED ON SEAL. | | | ***RESPONSE NOTED, BUT THE SEAL IS NOT | | | DATED YET ON MANY SHEETS. ALSO SHEETS | | | SEALED AFTER JAN. 1, 2006 SHALL BE | | | SEALED WITH THE NEW "LICENCE" SEAL PER | | | ATTACHED LETER FROM THE FLORIDA BOARD OF | | | PROFESSIONAL ENGENEERS. | | | | | | 30. THE FOLLOWING INFORMATION IS RQUIRED | | | FOR GAS PERMIT: | | | D. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). - WILL CHECK | | | WHEN ALL LENGTHS ARE SHOWN. ***RESPONSE | | | NOTED, BUT THE TOTAL DEVELOPED LENGTH | | | ADDS UP TO 232FT TO R.T.U #2, NOT 244 | | | FT. AS SHOWN. | | | F. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. - | | | DELEVERY PRESSURE IS USUALLY 11 TO 14 | | | INCHES OF WATER COLUMN OR 56 INCHES OF | | | WATER COLUMN, AND PLANS SHOW 7". PLEASE | | | CHECK WITH GAS PROVIDER AND VERIFY THE | | | DELIVERY PRESSURE. -RESPONSE NOTED, | | | BUT PLANS STILL SHOW 7" WATER COLUMN. | | | ***RESPONSE NOTED, BUT THE PLANS STILL | | | SHOW 7"WC PRESSURE. PLEASE CALL MR. | | | ROLAND PARKER, SERVICE MANAGER FLORIDA | | | PUBLIC UTILITIES AT (561) 838-1818 AS HE | | | HAS INDICATED TO ME THAT FPU DELIVERS | | | 12" TO 14" WATER COLUMN MINIMUM | | | PRESSURE. | | | G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2. - GAS | | | DRYER AND RTU'S MANUF. SHEETS NOT FOUND. | | | ***RESPONSE NOTED, BUT MANUF. SHEETS FOR | | | THE RTU-2 UNITS HAVE NOT BEEN SUBMITTED. | | | ALSO DRYER MANUF. SPECIFICATION SHEET | | | INDICATES THE BTU'SARE 165,000 WHERE | | | AS THE RISER DIAGRAM INDICATES 215,000 | | | BTU'S. PLEASE CLARIFY AND CORRELATE THE | | | MANUF. INFORMATION WITH THE RISER | | | DIAGRAM. | | | | | | ***************NEW COMMENT************** | | | 1C. SHT P-08 THE FOLLOWING INFORMATION | | | HAS BEEN DELETED FROM PREVIOUS SUBMITTED | | | SHEETS: | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | 2C. SEE ATTACHED SHEET CONCERNING THE | | | DESIGN PROFESSIONAL AND FS 553.80(2)(B). | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-11-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-11-26 |
Time |
20:13 |
Rev Time |
7.00 |
| Received By |
kstevens |
Date |
2005-11-26 |
Time |
20:13 |
Sent To |
|
|
| Notes |
| 2005-11-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW: | | | 1. PLANS SHALL BE ROUTED TO DBPR | | | DIVISION OF HOTEL AND RESTURANTS FOR | | | REVIEW. MINIMUM OF 2 STAMPED SETS OF | | | PLANS SHALL BE SUBMITTED TO THE CITY FOR | | | REVIEW WITH 2 PAGE "WORK SHEETS" | | | ATTACHED TO EACH SET. SECTION 101.4.7. - | | | PER RESPONSE SHEET CONTRACTOR WAS | | | SUPPOSED TO DO THIS. NO STAMPED SETS OF | | | PLANS OR WORKSHEETS SUBMITTED. | | | 3. GREASE INTERCEPTOR SHALL BE SIZED BY | | | RODNEY COMPO, ENVIRONMENTAL COMPLIANCE. | | | (561) 837-4074, E-MAIL [email protected], | | | OR FAX (561) 659-7458. THE DETERMINATION | | | WORKSHEET FROM MR. COMPO SHALL BE | | | ATTACHED TO PLANS WHEN RESUBMITTING FOR | | | REVIEW. - NO INFORMATION FROM MR. COMPO | | | AS OF YET. I WILL CHECK TO SEE IF HE HAS | | | A DETERMINATION FOR THIS JOB. | | | 4. SHT C-8 CIVIL WATER AND SEWER PLANS. | | | NO WATER SERVICE TO THE BUILDING IS | | | SHOWN. PLEASE INDICATE WATER SERVICE ON | | | PLANS INCLUDING PIPE SIZE, VALVES, | | | BACKFLOW ECT. - SHT C-9 INDICATES A 3" | | | DIP WATER SERVICE, BUT NO BACKFLOW SHOWN | | | FOR WATER SERVICE TO BUILDING. | | | 5. SHTS A-1.0, & A-6.1,(DETAILS 10 & 11) | | | LOUNGE SINK SHALL COMPLY WITH 11-4.24 | | | AND ALL SUBSECTIONS. SHOW THE FOLLOWING: | | | B. KNEE CLEARANCE 11-4.24.3 - KNEE | | | CLEARANCE NOT SHOWN. | | | C. SINK DEPTH 11-4.24.4 - SINK DEPTH | | | NOT SHOWN. | | | D. CLEAR FLOOR SPACE 11-4.24.5 SHALL BE | | | FORWARD APPROACH, AND SHALL EXTEND A | | | MAXIMUM 19" UNDERNEATH THE SINK. CABINET | | | DOORS ARE NOT APPROVED, MUST BE "CLEAR" | | | FLOOR SPACE. - CLEAR FLOOR SPACE SHALL | | | BE SHOWN ON THE FLOOR PLAN. | | | E. EXPOSED PIPES & SURFACES 11-4.24.6 - | | | NO RESPONSE TO THIS REQUIREMENT. | | | F. FAUCETS 11-4.24.7 - NO RESPONSE TO | | | THIS REQUIREMENT. | | | 6. SHOW COMPLIANCE WITH SECTION 11-9.1.4 | | | INDICATE ROOM NUMBERS FOR EACH | | | REQUIREMENT. - THERE ARE 6 DIFFERENT | | | TYPES OF UNITS SHOWN, BUT ONLY SUITES 1, | | | 2, AND A SHOW ACCESSIBLE UNITS. PLEASE | | | INDICATE WHY SUITES B, C, AND D HAVE NO | | | ACCESSIBLE UNITS AS REQUIRED BY SECTION | | | 11-9.1.4. | | | 9. SHT A-6.2 SHOW THE ACCESSIBLE W/C'S | | | TO BE 18" OFF THE WALL TO THE CENTERLINE | | | OF THE FIXTURE, AS REQUIRED IN FIG. 28. | | | - NOT ADDRESSED, ALSO SEE FIG 30E. | | | 10) SHT A-6.2 SHOW THE FOLLOWING FOR THE | | | ACCESSIBLE FIXTURES: | | | FOR W/C'S | | | A. CLEAR FLOOR SPACE. 11-4.16.2 - | | | SUPERIMPOSE CLEAR FLOOR SPACE ON PLANS. | | | SEE FIG'S 28 & 30E. | | | D. FLUSH CONTROLS 11-4.16.5 - NOT | | | INDICATED TO WIDE SIDE OF W/C. | | | E. DISPENSERS 11-4.16.6 - INDICATE | | | HEIGHT AS REQUIRED. | | | FOR URINAL | | | B. CLEAR FLOOR SPACE 11-4.18.3 - NOT | | | SHOWN. | | | FOR LAVS | | | A. HEIGHT & CLEARANCES 11-4.19.2 - | | | CLEARANCE MEASUREMENT NOT SHOWN. | | | B. CLEAR FLOOR SPACE 11-4.19.3 - SHOW | | | ON PLANS. | | | C. EXPOSED PIPES & SURFACES 11-4.19.4 - | | | INDICATE METHOD. | | | D. FAUCETS 11-4.19.5 - NOT ADDRESSED. | | | 12. ALL MECH., ELECT., & PLMB. SHEETS. | | | EACH SHEET OF PLANS WHICH MUST BE SEALED | | | UNDER THE PROVISIONS OF CHAPTER 471 | | | SHALL BE SEALED, SIGNED AND DATED BY THE | | | PROFESSIONAL ENGINEER. 61G15-23.002(1). | | | NO DATE AFFIXED TO SEAL/SIGNATURE. - | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME AND LICENSE NUMBER, AS WELL AS THE | | | NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. 61G15-23.002(2) | | | FAC, & FS 471.025. - THE DATE SEAL AND | | | SIGNATURE SHALL BE PLACED ON SEAL. | | | 13. SHT P-01 DOMESTIC PUMPS SHALL BE | | | LISTED. SUBMIT MANUF. SPECIFICATION | | | SHEETS. SECTION 303.4. - NO LISTING | | | SHOWN ON SHEETS. | | | 19. SHT P-02C KITCHEN EQUIPMENT | | | CONNECTION NOTES 1 & 4. THE AIR GAP | | | SHALL BE TWICE THE DIAMETER OF THE | | | EFFECTIVE OPENING OF THE INDIRECT WASTE | | | PIPE. SECTION 802.2.1. - NOTE #1 3" AIR | | | GAP REQUIRED. 1-1/2" SHOWN. | | | 30. THE FOLLOWING INFORMATION IS RQUIRED | | | FOR GAS PERMIT: | | | A. SHT P-08 SUBMIT AN ISOMETRIC DRAWING | | | THAT CLEARLY SHOWS ALL CUT SECTIONS OF | | | PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2001 FUEL GAS CODE. - NOT ALL | | | SECTIONS SHOW THE LENGTH OF THE PIPES. | | | D. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). - WILL CHECK | | | WHEN ALL LENGTHS ARE SHOWN. | | | F. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. - | | | DELEVERY PRESSURE IS USUALLY 11 TO 14 | | | INCHES OF WATER COLUMN OR 56 INCHES OF | | | WATER COLUMN, AND PLANS SHOW 7". PLEASE | | | CHECK WITH GAS PROVIDER AND VERIFY THE | | | DELIVERY PRESSURE. -RESPONSE NOTED, | | | BUT PLANS STILL SHOW 7" WATER COLUMN. | | | G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2. - GAS | | | DRYER AND RTU'S MANUF. SHEETS NOT FOUND. | | | ***************NEW COMMENT************** | | | 1B. GREASE INTERCEPTOR SHOWN IN STORAGE | | | ROOM NOT APPROVED. GREASE INTERCEPTOR | | | SHALL BE LOCATED OUTSIDE OF THE BUILDING | | | FOR SERVICING. MISSED LOCATION ON FIRST | | | REVIEW. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-07 |
Time |
12:50 |
Rev Time |
18.50 |
| Received By |
kstevens |
Date |
2005-06-06 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2005-06-07 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. PLANS SHALL BE ROUTED TO DBPR | | | DIVISION OF HOTEL AND RESTURANTS FOR | | | REVIEW. MINIMUM OF 2 STAMPED SETS OF | | | PLANS SHALL BE SUBMITTED TO THE CITY FOR | | | REVIEW WITH 2 PAGE "WORK SHEETS" | | | ATTACHED TO EACH SET. SECTION 101.4.7. | | | 2. SUBMIT CALCULATIONS FOR MINIMUM | | | FACILITIES FOR 1ST AND 6TH FLOOR COMMON | | | AREAS PER TABLES 1003.2 (BLDG) AND 104.3 | | | (PLMG). SHOW SQUARE FEET OF EACH COMMON | | | AREA. ASSEMBLY AREAS SHALL HAVE POTTY | | | PARITY PER SECTION 403.1.1. | | | 3. GREASE INTERCEPTOR SHALL BE SIZED BY | | | RODNEY COMPO, ENVIRONMENTAL COMPLIANCE. | | | (561) 837-4074, E-MAIL [email protected], | | | OR FAX (561) 659-7458. THE DETERMINATION | | | WORKSHEET FROM MR. COMPO SHALL BE | | | ATTACHED TO PLANS WHEN RESUBMITTING FOR | | | REVIEW. | | | 4. SHT C-8 CIVIL WATER AND SEWER PLANS. | | | NO WATER SERVICE TO THE BUILDING IS | | | SHOWN. PLEASE INDICATE WATER SERVICE ON | | | PLANS INCLUDING PIPE SIZE, VALVES, | | | BACKFLOW ECT. | | | 5. SHTS A-1.0, & A-6.1,(DETAILS 10 & 11) | | | LOUNGE SINK SHALL COMPLY WITH 11-4.24 | | | AND ALL SUBSECTIONS. SHOW THE FOLLOWING: | | | A. HEIGHT 11-4.24.2 | | | B. KNEE CLEARANCE 11-4.24.3 | | | C. SINK DEPTH 11-4.24.4 | | | D. CLEAR FLOOR SPACE 11-4.24.5 SHALL BE | | | FORWARD APPROACH, AND SHALL EXTEND A | | | MAXIMUM 19" UNDERNEATH THE SINK. CABINET | | | DOORS ARE NOT APPROVED, MUST BE "CLEAR" | | | FLOOR SPACE. | | | E. EXPOSED PIPES & SURFACES 11-4.24.6 | | | F. FAUCETS 11-4.24.7 | | | 6. SHOW COMPLIANCE WITH SECTIONS | | | 11-9.1.2, 11-9.1.3, 11-9-1-4, & 11-9.2.3 | | | INDICATE ROOM NUMBERS FOR EACH | | | REQUIREMENT. | | | 7. SHT A-1.5 SUBMIT CALCULATIONS FOR | | | PRIMARY AND SECONDARY ROOF DRAINS PER | | | SECTIONS 1106 & 1107 AND ALL SUBSECTIONS | | | INDICATE THE SQUARE FOOTAGE OF EACH | | | AREA, AND SHOW 1/2 AREA OF ALL VERTICAL | | | WALLS INCLUDING PARAPETS ADDED TO THE | | | SQUARE FOOTAGE OF EACH AREA AS WELL AS | | | ANY ROOF AREA DRAINING ON TO THE FOOR | | | FROM ABOVE IN THE CALCULATIONS. SHOW THE | | | LOCATIONS FOR ALL SECONDARY ROOF DRAINS. | | | 8. SHT A-6.0 SHOW CLEAR FLOOR SPACE FOR | | | LAVS. SECTION 11-4.19.3. | | | 9. SHT A-6.2 SHOW THE ACCESSIBLE W/C'S | | | TO BE 18" OFF THE WALL TO THE CENTERLINE | | | OF THE FIXTURE, AS REQUIRED IN FIG. 28. | | | 10) SHT A-6.2 SHOW THE FOLLOWING FOR THE | | | ACCESSIBLE FIXTURES: | | | FOR W/C'S | | | A. CLEAR FLOOR SPACE. 11-4.16.2 | | | B. HEIGHT 11-4.16.3 (ONE SHOWS 15") | | | C. GRAB BARS 11-4.16.4 (ONE SHOWS 37") | | | D. FLUSH CONTROLS 11-4.16.5 | | | E. DISPENSERS 11-4.16.6 | | | FOR URINAL | | | A. HEIGHT 11-4.18.2 | | | B. CLEAR FLOOR SPACE 11-4.18.3 | | | C. FLUSH CONTROLS 11-4.18.4 | | | FOR LAVS | | | A. HEIGHT & CLEARANCES 11-4.19.2 | | | B. CLEAR FLOOR SPACE 11-4.19.3 | | | C. EXPOSED PIPES & SURFACES 11-4.19.4 | | | D. FAUCETS 11-4.19.5 | | | 11. SHT A-8.0 ROOM FINISH SCHEDULE. 1ST | | | FLOOR AND 6TH FLOOR TOILET ROOMS. WALLS | | | SHALL BE NON-ABSORBENT UP TO 4' ABOVE | | | THE FLOOR. EXPLAIN HOW THIS WILL | | | ACHIEVED BY PAINTING GWB. SECTION 1204.2 | | | 12. ALL MECH., ELECT., & PLMB. SHEETS. | | | EACH SHEET OF PLANS WHICH MUST BE SEALED | | | UNDER THE PROVISIONS OF CHAPTER 471 | | | SHALL BE SEALED, SIGNED AND DATED BY THE | | | PROFESSIONAL ENGINEER. 61G15-23.002(1). | | | NO DATE AFFIXED TO SEAL/SIGNATURE. - | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME AND LICENSE NUMBER, AS WELL AS THE | | | NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. 61G15-23.002(2) | | | FAC, & FS 471.025. | | | 13. SHT P-01 DOMESTIC PUMPS SHALL BE | | | LISTED. SUBMIT MANUF. SPECIFICATION | | | SHEETS. SECTION 303.4 | | | 14. SHT P-01 170 GAL. SYNCROFLO | | | HYDROCUMULATOR TANK HAS NO PIPING TO IT. | | | PLEASE INDICATE HOW THIS WILL BE PIPED. | | | SECTION 104.2.1. | | | 15. SHTS P-02A & P-04B 2" EXPRESS DRAIN | | | FOR FIRE SPRINKLER SYSTEM TO DRAIN TO | | | THE SANT. SYSTEM. SECTION 701.4 | | | 16. SHT P-02A INDICATE SANT. RISER | | | NUMBER FOR LINE NEXT TO ST/10 RISER. | | | SECTION 104.2.1. | | | 17. SHT P-02A LINES AT MATCH LINE ABOVE | | | BUILDING SANT. DRAIN LINE (GAS, HOT | | | WATER ECT.) NOT SHOWN AS CONTINUING ON | | | SHT P-02B. PLEASE INDICATE WHERE THESE | | | LINES CONTINUE TO RUN, LABEL AND | | | IDENTIFY ALL LINES. SECTION 104.2.1. | | | 18. SHTS P-02A & P-02C 2-WAY CLEANOUTS | | | ARE REQUIRED ON THE INLET AND OUTLET OF | | | THE GREASE INTERCEPTOR. CITY STANDARD. - | | | ALSO A 2-WAY CLEANOUT IS REQUIRED NEAR | | | THE JUNCTION OF THE BUILDING DRAIN AND | | | THE BUILDING SEWER. SECTION 708.3. | | | 19. SHT P-02C KITCHEN EQUIPMENT | | | CONNECTION NOTES 1 & 4. THE AIR GAP | | | SHALL BE TWICE THE DIAMETER OF THE | | | EFFECTIVE OPENING OF THE INDIRECT WASTE | | | PIPE. SECTION 802.2.1. | | | 20. SHT P-02C MORE INFORMATION IS | | | REQUIRED ON THE "OPEN SITE DRAINS". | | | PLEASE INDICATE WHAT TYPE OF FIXTURE | | | THIS IS, AND WHAT IS THE PURPOSE FOR | | | THIS FIXTURE. SECTION 104.2.1. | | | 21. SUBMIT A BUILDING DRAIN SANITARY | | | RISER DIAGRAM IN ISOMETRIC FORM SHOWING | | | ALL PIPE SIZES, CLEANOUTS, VENTS, RISER | | | LOCATIONS, AND DRAINAGE FIXTURE UNITS AS | | | THEY ACCUMULATE IN THE SYSTEM. SECTIONS | | | 104.2.1. & 140.3.1.1. | | | 22. SHT P-02B SANT. BRANCH LINE | | | CONNECTING DOWNSTREAM OF RISER P/8. | | | PLEASE INDICATE WHAT FIXTURES CONNECT TO | | | THIS BRANCH LINE. SECTION 104.2.1. | | | 23. SHT P-07 WATER HEATER DETAIL. BOTTOM | | | FED WATER HEATERS SHALL HAVE A VACUUM | | | RELIEF VALVE INSTALLED. SECTION 504.2. - | | | ONE WATER HEATER DETAIL INDICATES (3 | | | REQUIRED) AND THE OTHER DETAIL INDICATES | | | (6 REQUIRED). PLEASE CLARIFY. SECTION | | | 104.2.1. | | | 24. SHT P-08 ROOFTOP PIPING SUPPORT TO | | | COMPLY WITH TABLE 308.5. - INDICATE HOW | | | SUPPORT IS ATTACHED TO ROOF AND HOW THE | | | SUPPORTS COMPLY WITH 140 MPH WIND LOADS. | | | SECTION 104.2.1. | | | 25. SHT P-10 RISER P/3 DOES NOT REFLECT | | | THE FLOOR PLAN AT 6TH FLOOR. SECTION | | | 104.2.1. | | | RISERS P/7 & P7A DOES NOT REFLECT THE | | | FLOOR PLAN 6TH FLOOR. SECTION 104.2.1. | | | 26. SHT P-11 BLDG DRAIN DOES NOT REFLECT | | | THE FLOOR PLAN. CLEANOUT IS NOT SHOWN ON | | | THE FLOOR PLAN UPSTREAM OF BRANCH LINE | | | TO RISER P/2. SECTION 104.2.1. | | | 26. SHT P-11 RISER P/4 DOES NOT REFLECT | | | THE FLOOR PLAN AT 6TH FLOOR. SECTION | | | 104.2.1. | | | 27. SHT P-11 PARTIAL SANITARY RISER | | | DIAGRAM DOES NOT REFLECT THE FLOOR PLAN. | | | F2 ON FLOOR PLAN SHOWN AS F1 ON RISER | | | DIAGRAM. PLEASE CORRELATE RISER WITH | | | FLOOR PLAN. SECTION 104.2.1. | | | 28. SHT P-13 RISER DOES NOT REFLECT | | | FLOOR PLAN. FLOOR DRAINS UPSTREAM OF | | | P/14 SHOWN AS 3" ON FLOOR PLAN AND 4" | | | ON THE RISER DIAGRAM. SECTION 104.2.1. | | | ALSO PIPE SHALL NOT REDUCE IN THE | | | DIRECTION OF FLOW. SECTION 704.2 | | | 29. SHT P-14 THE FOLLOWING CORRECTIONS | | | ON THE FOLLOWING RISER REQUIRED: | | | A. ST/3 5" MINIMUM ON HORIZONTAL | | | B. ST/9 4" MINIMUM ON HORIZONTAL | | | C. ST/11 4" MINIMUM ON HORIZONTAL | | | D. ST/13 4" MINIMUM ON HORIZONTAL | | | E. ST/15 4" MINIMUM ON HORIZONTAL | | | 30. THE FOLLOWING INFORMATION IS RQUIRED | | | FOR GAS PERMIT: | | | A. SHT P-08 SUBMIT AN ISOMETRIC DRAWING | | | THAT CLEARLY SHOWS ALL CUT SECTIONS OF | | | PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2001 FUEL GAS CODE. | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | C. TYPE OF GAS, (LP OR NATURAL) | | | D. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | E. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | | GAS CODE SECTION 304. - THIS IS FOR THE | | | WATER BOOSTER. | | | F. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. - | | | DELEVERY PRESSURE IS USUALLY 11 TO 14 | | | INCHES OF WATER COLUMN OR 56 INCHES OF | | | WATER COLUMN, AND PLANS SHOW 7". PLEASE | | | CHECK WITH GAS PROVIDER AND VERIFY THE | | | DELIVERY PRESSURE. | | | G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | H. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | I. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | 31. ARCHITECTURAL SHEETS, THERE ARE SOME | | | SHEETS THAT ARE NOT SEALED, AND MOST | | | SHEETS THE SEAL DOES NOT SHOW THE | | | INFORMATION REQUIRED BY FAC 61G1-16.002 | | | AND FS 481.221 - THE TITLE BLOCK IS | | | MISSING THE FOLLOWING INFORMATION: | | | (2) FIRM LICENSE NUMBER | | | SEE FAC 61G1-16.004 & FS 481.2055 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
9 |
Status |
P |
Date |
2008-05-07 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2008-05-07 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2008-05-07 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2008-05-07 17:55:56 | PLANNING AND ZONING: **** PASSED WITH THE PROVISO THAT | | | THE MINOR AMENDMENT NOTED ON COMM. #2 IS APPROVED BY | | | THE PLANNING AND ZONING DEPT. PRIOR TO FINAL | | | CERTIFICATE OF OCCUPANCY ("CO").**** | | | | | | NOTE: THE PASSED STATUS IS ONLY FOR THE GENERATOR | | | ENCLOSURE. | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | | | THE FOLLOWING COMMENTS ARE TO BE ADDRESSED IN THE MINOR | | | AMENDMENT AS WELL AS THE FINAL PERMIT. | | | | | | 2. THIS PERMIT IS PART OF AN APPLICATION UNDER REVIEW | | | FOR A MINOR AMENDMENT (PB1402F) TO THE COURTNEY LAKES | | | RESIDENTIAL PLANNED DEVELOPMENT (RPD), HAWTHORN SUITES | | | HOTEL.SIGN-OFF FROM THE PLANNING AND ZONING DEPT. FOR | | | THE FINAL CO. IS CONTINGENT UPON THE APPROVAL OF THE | | | MINOR AMENDMENT.THE DRAWINGS SHALL REFLECT ALL | | | REVISIONS PERTAINING TO LANDSCAPING, RE-LOCATION OF THE | | | COMPACT SPACES, SCREENING OF THE GENERATOR AND | | | MECHANICAL EQUIPMENT ON ROOF-TOP, INCLUDING DETAILS. | | | PROVIDE ALL SHEETS INCLUDING, BUT NOT LIMITED TO MSP 1 | | | AND 2, PD/SHEET C1, FH/SHEET C2 AND LANDSCAPING SHEETS | | | (LA-1 AND LA-2) THAT ARE PART OF PERMIT NUMBER. | | | 05041760 - "RE-SUBMITTAL TO GO WITH ENGINEERING | | | DRAWINGS" (RECEIVED ON APRIL 4, 2008) UNDER COMMENTS | | | COVER FORM (THE WEITZ CO.). | | | *** NOTE: ADDRESS ALL LANDSCAPING COMMENTS FROM ROBERT | | | KUSSNER. | | | | | | 3.THE BOLLARD(S) NEED TO BE RELOCATED/RECONFIGURED | | | OUT OF THE PARKING SPACE LOCATED NEXT TO THE LARGE | | | GENERATOR. | | | | | | 4.LANDSCAPING PLANS - LABEL COMPACT SPACES ON | | | LANDSCAPE PLANS AS NOTED ON SITE PLANS (SHEETS MSP1 AND | | | MSP2). | | | | | | 5.SHEET MSP2 OF 2 - LOCATION OF HANDICAP SYMBOL'S | | | LOWER-END SHALL BE TWO (2) FEET FROM THE PARKING STRIPE | | | DETAIL INSTEAD OF FOUR (4) FEET SIX (6) INCHES. | | | | | | 6.PROVIDE AN ENLARGED DETAIL OF THE HOTEL SITE PLAN | | | AREA FOR THE DIMENSIONS, ETC. TO BE LEGIBLE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME AT THE | | | NUMBER BELOW. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
8 |
Status |
P |
Date |
2008-04-07 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2008-04-07 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2008-04-07 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2008-04-07 19:05:44 | PLANNING AND ZONING: **** PASSED WITH THE PROVISO THAT | | | THE MINOR AMENDMENT NOTED ON COMM. #2 IS APPROVED BY | | | THE PLANNING AND ZONING DEPT. PRIOR TO FINAL | | | CERTIFICATE OF OCCUPANCY ("CO").**** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | | | 2. THIS PERMIT IS PART OF AN APPLICATION UNDER REVIEW | | | FOR A MINOR AMENDMENT (PB1402F) TO THE COURTNEY LAKES | | | RESIDENTIAL PLANNED DEVELOPMENT (RPD), HAWTHORN SUITES | | | HOTEL.SIGN-OFF FROM THE PLANNING AND ZONING DEPT. FOR | | | THE FINAL CO. IS CONTINGENT UPON THE APPROVAL OF THE | | | MINOR AMENDMENT.THE DRAWINGS SHALL REFLECT ALL | | | REVISIONS PERTAINING TO LANDSCAPING, RE-LOCATION OF THE | | | COMPACT SPACES, SCREENING OF THE GENERATOR AND | | | MECHANICAL EQUIPMENT ON ROOF-TOP, INCLUDING DETAILS. | | | PROVIDE ALL SHEETS INCLUDING, BUT NOT LIMITED TO MSP 1 | | | AND 2, PD/SHEET C1, FH/SHEET C2 AND LANDSCAPING SHEETS | | | (LA-1 AND LA-2) THAT ARE PART OF PERMIT NUMBER. | | | 05041760 - "RE-SUBMITTAL TO GO WITH ENGINEERING | | | DRAWINGS" (RECEIVED ON APRIL 4, 2008) UNDER COMMENTS | | | COVER FORM (THE WEITZ CO.). | | | *** NOTE: ADDRESS ALL LANDSCAPING COMMENTS FROM ROBERT | | | KUSSNER. | | | | | | 3.THE BOLLARD(S) NEED TO BE RELOCATED/RECONFIGURED | | | OUT OF THE PARKING SPACE LOCATED NEXT TO THE LARGE | | | GENERATOR. | | | | | | 4.LANDSCAPING PLANS - LABEL COMPACT SPACES ON | | | LANDSCAPE PLANS AS NOTED ON SITE PLANS (SHEETS MSP1 AND | | | MSP2). | | | | | | 5.SHEET MSP2 OF 2 - LOCATION OF HANDICAP SYMBOL'S | | | LOWER-END SHALL BE TWO (2) FEET FROM THE PARKING STRIPE | | | DETAIL INSTEAD OF FOUR (4) FEET SIX (6) INCHES. | | | | | | 6.PROVIDE AN ENLARGED DETAIL OF THE HOTEL SITE PLAN | | | AREA FOR THE DIMENSIONS, ETC. TO BE LEGIBLE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME AT THE | | | NUMBER BELOW. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
7 |
Status |
P |
Date |
2006-08-04 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-08-04 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-08-04 |
Time |
16:57 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
F |
Date |
2006-07-25 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-07-25 |
Time |
19:18 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-07-25 |
Time |
18:52 |
Sent To |
I |
|
| Notes |
| 2006-07-25 00:00:00 | PLANNING AND ZONING: FAILED | | | | | | 1. PROVIDE ALL RESPONSES TO COMMENTS IN | | | WRITING. | | | | | | 2. PLANS NEED TO HAVE ORIGINAL SIGNED | | | AND SEALED STAMP (I.E. SITE PLAN, | | | LANDSCAPE PLANS, AND OTHER PERTINENT | | | PLANS) | | | | | | 3.PURSUANT TO 94-444- DUMPSTER SHOWN | | | ON SITE PLAN DOES NOT COMPLY WITH | | | DIMENSIONAL REQUIREMENTS AND | | | SPECIFICATION.SEE FIGURE XIV-3.I | | | HAVE INCLUDED A DETAIL COPY FOR YOUR | | | USE.THE DUMPSTER SHOWN ON SITE PLAN | | | SHOWS TO BE A WIDTH OF ONLY 12 FEET. | | | | | | 4.IN ADDITION, YOUR DUMPSTER DETAIL ON | | | MSP PLANS, SHEET 2 OF 2 INCLUDES A | | | RECYCLE BIN, THIS IS NOT SHOWN ON THE | | | SITE PLAN. REVISE TO CORRELATE ON BOTH | | | DETAILS SHEET, SITE PLAN, LANDSCAPE PLAN | | | AND ALL OTHER PERTINENT DOCUMENTATION. | | | REDUCTION IN LANDSCAPE STRIP WILL NOT BE | | | ALLOWED TO ACCOMODATE RECYCLE BIN IF | | | CALCULATIONS FOR LANDSCAPING WERE | | | INCLUDED IN THIS AREA. THERE ARE 2 | | | DUMPSTER DETAILS SHOWN. ONE HAS A | | | RECYCLE BIN OF 5'-8" THE OTHER 8'-10" IN | | | WIDTH.PLEASE CLARIFY, AS ONLY ONE | | | DUMPSTER AREA IS SHOWN ON SITE PLAN. | | | | | | 5.PURSUANT TO SECTION 94-485 -STALL | | | PAINTING DETAIL ON MSP PLANS, SHEET 2 OF | | | 2 DOES NOT COMPLY.A COPY OF THE | | | STRIPPING DETAIL IS ATTACHED FOR | | | REFERENCE. THE INTERIOR WIDTH NEED TO BE | | | 12" AND THE WHITE LINES ON THE OUTER | | | AREA NEED TO BE 4".PLEASE REFERENCE ON | | | NOTES THAT THE PARKING DETAILS WILL | | | COMPLY WITH CITY OF WEST PALM BEACH CODE | | | REQUIREMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | LINDA MIA FRANCO @ (561) 822-1435. | | | | | | THANK YOU. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2006-07-20 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-07-20 |
Time |
19:28 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-07-20 |
Time |
19:28 |
Sent To |
I |
|
| Notes |
| 2006-07-20 00:00:00 | PLANNING AND ZONING: | | | FAILED ON 7-20-06-NO SITE PLAN WAS | | | SUBMITTED. | | | | | | FAILED ON 5-17-06 | | | | | | COMMENTS FROM 4-4-06 ARE STILL | | | OUTSTANDING. | | | | | | 1. THE SITE PLANS ON ALL SUBMITTED | | | DOCUMENTATION NEED TO MATCH THE MINOR | | | AMENDMENT CASE PB1402C APPROVED | | | (4-03-06) SITE PLANS. (I.E. ALL THE | | | ELECTRICAL PLANS, MILLER LEGG PLANS USED | | | THE OLD, NON CONFORMING SITE PLAN AS | | | THEIR FOOTPRINT). | | | | | | | | | 2.A COPY OF THE ORIGINAL APPROVED | | | PLANS HAS BEEN SUBMITTED FROM THE | | | PLANNING DEPARTMENT INTO YOUR PACKET, | | | FOR YOUR USE. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | LINDA MIA FRANCO @ (561) 822-1435. | | | | | | THANK YOU, | | | | | | LINDA MIA FRANCO |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-05-18 |
Time |
19:07 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-05-18 |
Time |
19:07 |
Sent To |
I |
|
| Notes |
| 2006-05-18 00:00:00 | PLANNING AND ZONING: FAILED ON 5-17-06 | | | | | | COMMENTS FROM 4-4-06 ARE STILL | | | OUTSTANDING. | | | | | | 1. THE SITE PLANS ON ALL SUBMITTED | | | DOCUMENTATION NEED TO MATCH THE MINOR | | | AMENDMENT CASE PB1402C APPROVED | | | (4-03-06) SITE PLANS. (I.E. ALL THE | | | ELECTRICAL PLANS, MILLER LEGG PLANS USED | | | THE OLD, NON CONFORMING SITE PLAN AS | | | THEIR FOOTPRINT). | | | | | | | | | 2.A COPY OF THE ORIGINAL APPROVED | | | PLANS HAS BEEN SUBMITTED FROM THE | | | PLANNING DEPARTMENT INTO YOUR PACKET, | | | FOR YOUR USE. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | LINDA MIA FRANCO @ (561) 822-1435. | | | | | | THANK YOU, | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | CITY OF WEST PALM BEACH |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-04-04 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-04-04 |
Time |
16:37 |
Sent To |
I |
|
| Notes |
| 2006-04-05 00:00:00 | PLANNING AND ZONING: FAILED | | | | | | 1. THE SITE PLANS ON ALL SUBMITTED | | | DOCUMENTATION NEED TO MATCH THE MINOR | | | AMENDMENT CASE PB1402C APPROVED | | | (4-03-06) SITE PLANS. (I.E. ALL THE | | | ELECTRICAL PLANS, MILLER LEGG PLANS USED | | | THE OLD, NON CONFORMING SITE PLAN AS | | | THEIR FOOTPRINT). | | | | | | | | | 2.A COPY OF THE ORIGINAL APPROVED | | | PLANS HAS BEEN SUBMITTED FROM THE | | | PLANNING DEPARTMENT INTO YOUR PACKET, | | | FOR YOUR USE. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | LINDA MIA FRANCO @ (561) 822-1435. | | | | | | THANK YOU, | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | CITY OF WEST PALM BEACH |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-01-06 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-01-05 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-01-05 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2006-01-05 00:00:00 | FAILED: | | | | | | ZONING COMMENTS: | | | | | | 1.PROVIDE RESPONSES TO COMMENTS IN | | | WRITING AND INDICATE THE REVISIONS ON | | | SITE PLAN. | | | | | | 2.PURSUANT TO SECTION 94-485(O)PAGE | | | CD 94:272 OF THE CODE,THE PROPOSED | | | "COMPACT" SMALL CAR SPACE DOES NOT | | | COMPLY WITH CODE REQUIREMENTS.FOR | | | EXAMPLE: | | | A. THE PROPOSED COMPACT SPACES, EXCEED | | | THE 30 PERCENT ALLOWED;AND, | | | B.SMALL AND STANDARD PARKING SPACES | | | SHALL BE DISTRIBUTED EQUALLY THROUGHOUT | | | A PARKING LOT, AND THE CITY ENGINEER | | | SHALL REVIEW THE DESIGN OF ALL PROPOSED | | | PARKING FACILITIES TO ENSURE THAT THE | | | INTENT OF THIS SECTION IS SATISFIED. | | | CONTACT THE CITY ENGINEER TO COORDINATE | | | AND PROVIDE A LETTER FROM THEM STATING | | | THAT THIS REQUIREMENT HAS BEEN | | | SATISFIED. | | | | | | 3.PURSUANT TO SECTION 94-485(O)PAGE | | | CD 94:273 OF THE CODE, THE AMOUNT OF | | | DISABLED PARKING SPACES PROPOSED DOES | | | NOT COMPLY.THERE ARE FIVE (5) REQUIRED | | | PARKING SPACES THAT NEED TO BE PROVIDED. | | | IN ADDITION, THE LOCATION OF THE SPACES | | | SHALL BE LOCATED SO THAT USERS ARE NOT | | | COMPELLED TO WALK OR OTHERWISE MOVE | | | BEHIND PARKED VEHICLES.WHY ARE THESE | | | SPACES LOCATED ACROSS DRIVE AISLES | | | INSTEAD OF CLOSE PROXIMITY TO THE | | | BUILDING ACCESS? REVISE ACCORDINGLY. | | | | | | 4.THE TYPICAL PARKING DETAIL DOES NOT | | | COMPLY WITH THE STALL PAINTING DETAIL IN | | | SECTION 94-485 (PAGE CD94:272).THE | | | BOTTOM STRIPPING DETAIL NEEDS TO BE | | | SQUARED-OFF.IN ADDITION, THERE NEEDS | | | TO BE TWO (2)FEET CLEARANCE FOR VEHICLE | | | OVERHANG, REFER TO DETAIL IN SECTION | | | 94-443 (PAGE CD94:253). | | | | | | 5. PURSUANT TO SECTION 94-486(O) PAGE | | | CD 94:274 OF THE CODE,THE SITE PLAN | | | DOES NOT SHOW OR ALLOCATE THE REQUIRED | | | BICYCLE PARKING SPACES. | | | | | | 6.PURSUANT TO SECTION 94-443(E)PAGE CD | | | 94:254 OF THE CODE, AT LEAST 30 PERCENT | | | OF THE LINEAR FEET AROUND THE EXTERIOR | | | OF ALL COMMERCIAL STRUCTURES SHALL BE | | | PLANTED WITH TREES, SHRUBS OR HEDGES; | | | THE PROPOSED SITE PLAN DOES NOT COMPLY | | | WITH THE REQUIRED FOUNDATION PLANTING. | | | | | | 7.PROVIDE CALCULATIONS OF OPEN SPACE | | | AND LANDSCAPE PERCENTAGE FOR THIS | | | (HOTEL) SITE. | | | | | | 8.PROVIDE THE SITE DATA ON PLANS (I.E. | | | BUILDING COVERAGE, SETBACKS, PARKING | | | REQUIREMENTS, DENSITY CALCULATIONS. | | | SITE PLAN NEEDS TO MATCH THE APPROVED | | | SITE PLAN OF RECORD. | | | | | | 9. IDENTIFY THE SQUARE FOOTAGE OF THE | | | DINING AREAS, KITCHENS, BARS, LOUNGES | | | AND MEETING ROOMS. PROVIDE INFORMATION | | | ON SITE DATA TABLE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
jlong |
Date |
2005-06-15 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
jlong |
Date |
2005-06-15 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2005-06-15 00:00:00 | 1. A MINOR PLANNED DEVELOPMENT AMENDMENT | | | IS REQUIRED TO APPROVE THE ALTERATION | | | AND RELOCATION OF PARKING, DUMPSTER, | | | POOL AND LANDSCAPING. | | | | | | 2. A COPY OF THE RECORDED PLAT WITH THE | | | FOLLOWING CONDITIONS IS REQUIRED: | | | A. TRACT C, LAKE, AND TRACT D, ROAD, | | | MUST REMAIN IN COMMON OWNERSHIP OF THE | | | OWNERS OF TRACT A, COURTNEY LAKES, AND | | | TRACT B, HOTEL. | | | B. PERPETUAL EASEMENTS FOR INGRESS, | | | EGRESS, DRAINAGE AND COMMON AREA | | | MAINTENANCE MUST EXIST BETWEEN ALL | | | PARCELS. | | | C. A PUBLIC ACCESS EASEMENT FOR THE LAKE | | | PATH IS REQUIRED. | | | | | | 3. A SITE DATA SHEET IS REQUIRED, THE | | | SHEET MUST IDENTIFY THE SQUARE FOOTAGE | | | OF THE DINING AREAS, KITCHENS, BARS, | | | LOUNGES AND MEETING ROOMS. | | | | | | 4. NONE OF THE HOTEL'S AMENITIES MAY BE | | | ADVERTISED TO THE PUBLIC. | | | | | | 5.CAN NOT PLACE A TRANSFORMER IN A | | | REQUIRED LANDSCAPE ISLAND. | | | | | | 6. MAY NOT HAVE MORE THAN 10 PARKING | | | SPACES IN ONE ROW. |
|
|