| Plan Review Stops For Permit 05041605 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-01 |
Time |
14:12 |
Rev Time |
1.20 |
| Received By |
jwitmer |
Date |
2005-12-01 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2005-12-01 00:00:00 | REVISIONS TO FOUNDATION #1 8-19-05JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-31 |
Time |
09:42 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2005-07-31 |
Time |
09:42 |
Sent To |
PC |
|
| Notes |
| 2005-07-31 00:00:00 | | | | *** ISSUED PERMIT*** | | | -PLAN REVIEW HISTORY- | | | | | | PERMIT# 05041605 | | | ADDRESS: 2211 N FLAGLER DR. | | | CONT: CENTEX | | | TELL # (561)478-0381 | | | | | | | | | | | | | | | | | | FOUNDATION PERMIT, SCOPE OF WORK TO | | | INCLUDE: | | | | | | VIBRO FLOTATION, TEST PILE, AUGERCAST | | | PILES, PILE CAPS, & SPREAD FOOTERS. | | | | | | | | | | | | | | | THE ATTACHED COMMENTS ARE PART OF THE | | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | | NOT TO BE REMOVED FROM THE ISSUED SET OF | | | PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | | | | | BUILDING PROVISO: | | | 104.4.5*. SPECIAL FOUNDATION | | | PERMIT WHEN APPLICATION FOR A PERMIT TO | | | ERECT OR ENLARGE A BUILDING HAS BEEN | | | FILED, & PENDING ISSURANCE OF SUCH | | | PERMIT, THE BUILDING OFFICIAL MAY, AT | | | HIS/ HER DISCRETION, ISSUE A SPECIAL | | | PERMIT FOR THE FOUNDATION ONLY, UPON | | | WRITTEN REQUEST OF THE OWNER AND | | | CONTRACTOR. THE HOLDER OF SUCH A SPECIAL | | | PERMIT IS PROCEEDING AT HIS OR HER OWN | | | RISK AND WITHOUT ASSURANCE THAT A PERMIT | | | FOR THE REMAINDER OF THE WORK WILL BE | | | GRANTED AND THAT CORRECTIONS WILL NOT BE | | | REQUIRED IN ORDER TO MEET THE PROVISIONS | | | OF THE TECHNICAL CODE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-06 |
Time |
09:36 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-06-06 |
Time |
08:47 |
Sent To |
PC |
|
| Notes |
| 2005-06-06 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05041605 | | | ADD: 2211 N FLAGLER | | | CONT:DELANT CONST | | | TEL: (305)495-3745 | | | | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) DESCREPANCY, WHEN THE MARK ANDREW | | | BUILDING WAS REVIEWED THIS PROJECT WAS | | | ASSIGNED 2323 N FLAGLER. THE 2211 IS A | | | BROWARD AVENUE ADDRESS. THE CITY WAS TO | | | ABANDONDED THE ROAD AND PARK. IF THE | | | ADDRESS 2211 IS TO BE USED, PLEASE | | | INDICATE SO BY WRITTEN REQUEST TO : | | | JOHN HIGGINS, MIS DEPARTMENT, CITY OF | | | WEST PALM BEACH, FL 33401. | | | | | | 3) TABLE 600, THE PROPOSED BUILDING | | | TRANSGRESSES PROPERTY LINES ACCORDING TO | | | THE SURVEY SUBMITTED. A REPLAT WILL BE | | | REQUIRED. | | | | | | 4) WPB AMENDMENT 105.13.6. W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A | | | SPECIAL INSPECTOR AS REQUIRED BY S. | | | 553.79(5) FLORIDA STATUTES TO THE MIN- | | | IMUM INSPECTIONS REQUIRED BY THIS CODE. | | | CONTACT HAROLD PISKURA MANAGER OF THE | | | SPECIAL INSPECTOR PROGRAM AT (561) | | | 805-6711 FOR FURTHER INFORMATION BEFORE | | | THE PERMIT MAY BE ISSUED. | | | | | | 5)BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2005-07-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-31 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2005-07-31 00:00:00 | FOUNDATION PERMIT ONLY, VIBROFLOTATION, | | | CAST AUGER PILE, PILE CAPS AND SPREAD | | | FOOTERS JW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-10 |
Time |
16:28 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-05-10 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2005-05-10 00:00:00 | ONE ROLL IN ELECTRICAL FOR REVIEW. | | | ************ UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE PLANS SUBMITTED FOR | | | FOUNDATION PERMIT TO INCLUDE UP TO | | | ELEVATION OF 10'. | | | PLEASE SEE PLANS ARE NOT COMPLETE AT | | | THIS TIME FOR FOUNDATION PERMIT. | | | | | | PLEASE SEE SIZE OF SERVICE , CONDUITS, | | | FEEDERS, GROUNDING, ETC CAN NOT BE | | | VERIFIED AT THIS TIME DUE TO PLANS BEING | | | INCOMPLETE FOR THIS. | | | PLEASE SEE PLANS NEED TO SHOW ALL | | | ELECTRICAL WHICH MAY NEED TO BE | | | INSTALLED IN FOUNDATION. | | | LOCATIONS OF ALL ELECTRICAL EQUIPMENT | | | FOR CODE COMPLIANCE NEEDS TO BE VERIFIED | | | FOR 2002 NEC AND ALL OTHER APPLICABLE | | | CODES. | | | | | | 2)NOTE: PLEASE SEE PLANS ARE REQUIRED TO | | | BE SIGNED, DATED AND SEALED BY | | | ARCHITECT'S AND ENGINEER'S OF RECORD PER | | | FAC 61G15-23.002,61G1-16, FS 481.221 AND | | | 471.025 | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | TRADES WHICH MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-18 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-18 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2005-10-18 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-06 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-05-02 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2005-05-02 00:00:00 | TO "COMM" BD#5/PLANS ON RACK, 3 ROLLS | | | AND 1 BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-07-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-31 |
Time |
09:43 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-31 |
Time |
09:44 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-03 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2005-06-03 |
Time |
14:36 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2005-06-03 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2005-06-03 00:00:00 | 06-03-05 SENT TO ZONING JOSH LONG |
|
|