Plan Review Details - Permit 05041543
Plan Review Stops For Permit 05041543
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-06-10 Cont ID  
Sent By alange Date 2005-06-10 Time 13:47 Rev Time 1.75
Received By alange Date 2005-06-10 Time 12:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-05-23 Cont ID  
Sent By alange Date 2005-05-23 Time 13:10 Rev Time 3.00
Received By alange Date 2005-05-23 Time 10:10 Sent To  
Notes
2005-05-23 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.) FBC* 104.6.5BUILDING PERMIT
 VALUATION.THE STATED VALUE OF THE
 PROJECT HAS BEEN UNDER-ESTIMATED AT
 $305,065.THE VALUE, CALCULATED USING
 THE SOUTHERN BUILDING CODE CONGRESS
 INTERNATIONAL (SBCCI) VALUATION TABLES,
 IS $323,591.THE PERMIT APPLICATION FEE
 HAS BEEN ADJUSTED ACCORDINGLY, SO THERE
 IS AN OUTSTANDING BALANCE OF $1809.17.
 THE REQUIRED AMOUNT SHALL BE PAID BEFORE
 THE PLANS CAN BE RESUBMITTED.
  
 3.BEDROOM #3 PGT WINDOW SH-701 DOES
 NOT MEET EGREES REQUIREMENTS.
  
 4.PGT SGD-2500 IS NOT AN IMPACT RATED
 DOOR.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-11-22 Cont ID  
Sent By dpalmer Date 2005-11-22 Time 09:48 Rev Time 0.30
Received By dpalmer Date 2005-11-22 Time 09:48 Sent To  
Notes
2005-11-22 00:00:00REDLINED
  
 20A OCP SHOWN ON #14 AWG.
 240.4,310.16

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-05-02 Cont ID  
Sent By dpalmer Date 2005-05-02 Time 08:58 Rev Time 0.33
Received By dpalmer Date 2005-05-02 Time 08:58 Sent To M
Notes
2005-05-02 00:00:00**** REDLINED****
  
  
 1) CORRELATE PANEL SCHEDULE "B" WITH
 RISER. SHOWS 3-#6'S FOR SUB PANEL AND
 RISER SHOWS 2-#6'S AND 1-#8.
  
 2) PLEASE SEE NEC 220 MOTOR LOADS ON SUB
 PANEL ARE AT 100%, 125% FOR ALL
 CONTINOUS LOADS.
 LOAD ON SUB PANEL IS NOT DERATED AS
 LIGHTING LOADS.
  
  
 PLEASE REVISETHE ABOVE ALONG WITH ANY
 OTHER REVISIONS.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-11-18 Cont ID  
Sent By adarroug Date 2005-11-18 Time 14:08 Rev Time 0.00
Received By adarroug Date 2005-11-18 Time 14:08 Sent To E
Notes
2005-11-18 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-09-29 Cont ID  
Sent By adarroug Date 2005-09-29 Time 18:42 Rev Time 0.00
Received By adarroug Date 2005-09-29 Time 18:42 Sent To P
Notes
2005-09-29 00:00:00TO "P" BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-06-01 Cont ID  
Sent By adarroug Date 2005-06-01 Time 14:14 Rev Time 0.00
Received By adarroug Date 2005-06-01 Time 14:14 Sent To B
Notes
2005-06-01 00:00:00TO "ALANGE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-04-29 Cont ID  
Sent By adarroug Date 2005-04-29 Time 12:54 Rev Time 0.00
Received By adarroug Date 2005-04-29 Time 12:54 Sent To E
Notes
2005-04-29 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-05-23 Cont ID  
Sent By alange Date 2005-05-23 Time 13:11 Rev Time 0.00
Received By alange Date 2005-04-22 Time 16:50 Sent To  
Notes
2005-04-22 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-05-03 Cont ID  
Sent By prafter Date 2005-05-03 Time 08:35 Rev Time 0.50
Received By prafter Date 2005-05-03 Time 08:35 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-05-03 Cont ID  
Sent By jleech Date 2005-05-03 Time 18:33 Rev Time 0.33
Received By jleech Date 2005-05-03 Time 18:33 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-04-28 Cont ID  
Sent By mmclean Date 2005-04-28 Time 18:14 Rev Time 0.00
Received By mmclean Date 2005-04-28 Time 18:14 Sent To I
Notes
2005-04-28 00:00:00MUST PULL SEPERATE PERMIT FOR
 POOL/SPA/DECK/SCREEN ENCLOSURE