| Plan Review Stops For Permit 05041543 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-06-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-06-10 |
Time |
13:47 |
Rev Time |
1.75 |
| Received By |
alange |
Date |
2005-06-10 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-05-23 |
Time |
13:10 |
Rev Time |
3.00 |
| Received By |
alange |
Date |
2005-05-23 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2005-05-23 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.) FBC* 104.6.5BUILDING PERMIT | | | VALUATION.THE STATED VALUE OF THE | | | PROJECT HAS BEEN UNDER-ESTIMATED AT | | | $305,065.THE VALUE, CALCULATED USING | | | THE SOUTHERN BUILDING CODE CONGRESS | | | INTERNATIONAL (SBCCI) VALUATION TABLES, | | | IS $323,591.THE PERMIT APPLICATION FEE | | | HAS BEEN ADJUSTED ACCORDINGLY, SO THERE | | | IS AN OUTSTANDING BALANCE OF $1809.17. | | | THE REQUIRED AMOUNT SHALL BE PAID BEFORE | | | THE PLANS CAN BE RESUBMITTED. | | | | | | 3.BEDROOM #3 PGT WINDOW SH-701 DOES | | | NOT MEET EGREES REQUIREMENTS. | | | | | | 4.PGT SGD-2500 IS NOT AN IMPACT RATED | | | DOOR. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-22 |
Time |
09:48 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-11-22 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2005-11-22 00:00:00 | REDLINED | | | | | | 20A OCP SHOWN ON #14 AWG. | | | 240.4,310.16 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-05-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-02 |
Time |
08:58 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-05-02 |
Time |
08:58 |
Sent To |
M |
|
| Notes |
| 2005-05-02 00:00:00 | **** REDLINED**** | | | | | | | | | 1) CORRELATE PANEL SCHEDULE "B" WITH | | | RISER. SHOWS 3-#6'S FOR SUB PANEL AND | | | RISER SHOWS 2-#6'S AND 1-#8. | | | | | | 2) PLEASE SEE NEC 220 MOTOR LOADS ON SUB | | | PANEL ARE AT 100%, 125% FOR ALL | | | CONTINOUS LOADS. | | | LOAD ON SUB PANEL IS NOT DERATED AS | | | LIGHTING LOADS. | | | | | | | | | PLEASE REVISETHE ABOVE ALONG WITH ANY | | | OTHER REVISIONS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-18 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-18 |
Time |
14:08 |
Sent To |
E |
|
| Notes |
| 2005-11-18 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-29 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-29 |
Time |
18:42 |
Sent To |
P |
|
| Notes |
| 2005-09-29 00:00:00 | TO "P" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-01 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-01 |
Time |
14:14 |
Sent To |
B |
|
| Notes |
| 2005-06-01 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-04-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-29 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-29 |
Time |
12:54 |
Sent To |
E |
|
| Notes |
| 2005-04-29 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-05-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-05-23 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-04-22 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2005-04-22 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-05-03 |
Time |
08:35 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-05-03 |
Time |
08:35 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-05-03 |
Time |
18:33 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-05-03 |
Time |
18:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-04-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-04-28 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-04-28 |
Time |
18:14 |
Sent To |
I |
|
| Notes |
| 2005-04-28 00:00:00 | MUST PULL SEPERATE PERMIT FOR | | | POOL/SPA/DECK/SCREEN ENCLOSURE |
|
|