| 2005-05-24 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2001 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC2001 |
| | |
| | 1.) THE "LEGAL DESCRIPTION" ON THE |
| | NOTICE OF COMMENCEMENT IS TO INCLUDE THE |
| | LEGAL DESCRIPTION OF THE PROPERTY |
| | FS713.13(1)(A)1.ONLY AN ADDRESS WAS |
| | PROVIDED. |
| | |
| | 2.) THE ARCHITECT'S SEAL IS TO BE DATED |
| | AS WELL AS SIGNED, FAC61G1-16.003, |
| | FS481. |
| | |
| | 3.)SHEET A0.1, PROJECT DATA, HAS 2C AS |
| | CONSTRUCTION TYPE, WHAT IS C?PLEASE |
| | SEE FBC604 AND CLARIFY. |
| | |
| | 4.)PRODUCT APPROVALS FOR FIXED GLASS |
| | WINDOWS WERE SUBMITTED.PLEASE SUBMIT |
| | LEGIBLE, ORIGINAL DOCUMENTS.THIS WAS A |
| | PHOTOCOPY STAMPED BY ANOTHER |
| | MUNICIPALITY.WWW.FLORIDABUILDING.ORG |
| | ON THE CLEAN COPY, INDICATE WHICH |
| | PRODUCT YOU ARE INSTALLING. |
| | |
| | 5.)WHERE ARE THE WINDOWS BEING |
| | INSTALLED?WHAT SIZE? |
| | |
| | 6.)PROVIDE INFORMATION REQUIRED BY |
| | FBC1606.1.7.DESIGN PRESSURES FOR THE |
| | WINDOWS ARE REQUIRED TO DETERMINE CODE |
| | COMPLIANCE.ALSO PROVIDE MEAN ROOF |
| | HEIGHT. |
| | |
| | 7.)PROVIDE A WINDOW BUCK DETAIL OR |
| | FASTENING SCHEDULE. |
| | |
| | 8.)IMPACT PROTECTION REQUIRED |
| | FBC1606.1.4. |
| | |
| | 9.)SEE ATTACHED IMPLEMENTATION |
| | STANDARD FOR HURRICANE MISSILE IMPACT |
| | PROTECTION, ITEMS 13 AND 14.SHUTTERS |
| | ARE ALLOWED FOR FIRST FLOOR ONLY IF |
| | APPROVED BY BUILDING OFFICIAL (IMPACT |
| | GLASS REQUIRED FOR SECOND AND THIRD |
| | FLOORS).IF YOU INTEND TO USE SHUTTERS |
| | FOR THE FIRST FLOOR WINDOWS, A PRE-STORM |
| | PREPARATION PLAN MUST BE APPROVED BY THE |
| | BUILDING OFFICIAL.THIS PLAN MAY BE |
| | SUBMITTED SEPARATELY FROM THE |
| | RESUBMITTAL FOR THE PERMIT.NOTE THAT |
| | SHUTTERS CANNOT BE STORED OFF SITE. |
| | |
| | 10.) ON THE FLORIDA PRODUCT APPROVAL, |
| | CIRCLE THE PRODUCT YOU WISH TO INSTALL. |
| | |
| | 11.)THE ADA ROOM DETAILS (SUCH AS |
| | A4.4, ADA CODE COMPLIANCE) REFER TO 28 |
| | CFR PART 36.PLEASE NOTE THAT THE |
| | GOVERNING CODE IS FBC CHAPTER 11, |
| | ACCESSIBILITY. |
| | |
| | 12.)THE EXISTING UNIVERSAL DOUBLE AND |
| | SINGLE UNITS HAVE BEEN REPLACED BY |
| | UNIVERSAL KING UNITS.PLEASE SEE |
| | FBC11-9.1.4(1) AND REVISE."FACTORS TO |
| | BE CONSIDERED INCLUDE ROOM SIZE, COST, |
| | AMENITIES PROVIDED, AND THE NUMBER OF |
| | BEDS PROVIDED."ADJOINING ROOMS WOULD |
| | ALSO BE CONSIDERED AN AMENITY.INDICATE |
| | ACCESSIBLE ROOMS WITH AN ADJOINING DOOR |
| | ON THE PLAN. |
| | |
| | 13.)SLEEPING ACCOMMODATIONS FOR |
| | PERSONS WITH HEARING IMPAIRMENTS |
| | REQUIRED, FBC11-9.1.3. |
| | |
| | 14.)INCLUDE WINDOW REPLACEMENT ON THE |
| | PERMIT APPLICATION. |
| | |
| | 15.)THE APPLICATION STATES THAT |
| | "ELECTRICAL AND PLUMBING WILL BE |
| | INCLUDED UNDER THIS PERMIT."A REVIEW |
| | WILL BE DONE UNDER THIS PERMIT BUT |
| | SEPARATE PERMIT APPLICATIONS FROM THE |
| | SUBCONTRACTORS ARE REQUIRED AS THIS IS |
| | NOT WITHIN THE SCOPE OF GC LICENSE. |
| | |
| | 16.)PROVIDE (ACCESSIBILITY) |
| | INFORMATION IN REGARDS TO THE ENTRANCE, |
| | ACCESSIBLE ROUTE, SIGNAGE, EXISTING |
| | RESTROOMS, TELEPHONES IN THE LOBBY.SEE |
| | FBC11-4.1.6(2), DUTY TO PROVIDE |
| | ACCESSIBLE FEATURES IN THE EVENT OF |
| | DISPROPORTIONALITY.IF ALL ITEMS ARE |
| | ALREADY ACCESSIBLE, SHOW COMPLIANCE ON |
| | THE PLAN (EXISTING CONDITIONS DETAIL). |
| | |
| | 17.)FBC*104.2.1, INFORMATION IS TO BE |
| | SPECIFIC, AND THE TECHNICAL CODES SHALL |
| | NOT BE CITED AS A WHOLE OR IN PART.FOR |
| | INSTANCE, A4.4, ADA CODE COMPLIANCE, |
| | "ALL OBJECTS AND CONTROLS INTENDED FOR |
| | GUEST USE COMPLY W/4.2.5 AND 4.2.6" AND |
| | "DOOR HARDWARE COMPLIANT W/4.13.9." |
| | PROVIDE SPECIFICATION, NOT CODE SECTION, |
| | IN ALL INSTANCES ON THE PLAN WHERE A |
| | CODE NUMBER WAS GIVEN IN LIEU OF DESIGN |
| | CRITERIA.THE TWO ABOVE WERE PROVIDED |
| | AS AN EXAMPLE; THERE MAY BE OTHER CODE |
| | REFERENCES WHICH NEED FURTHER DESIGN |
| | SPECIFICATION. |
| | |
| | 18.) PROVIDE ENTRY DOOR WIDTH FOR THE |
| | ACCESSIBLE UNITS. |
| | |
| | 19.)DRAWER HARDWARE IS TO BE COMPLIANT |
| | WITH FBC11-4.25.4, FBC11-4.27.4. |
| | |
| | 20.)SPECIFY DESIGN CRITERIA FOR |
| | STRENGTH OF GRAB BARS, ETC. |
| | FBC11-4.26.3. |
| | |
| | 21.)SHOW THE DEPTH OF THE PTAC FOR THE |
| | ACCESSIBLE UNITS, MAX OF 10" FBC11 |
| | FIGURE 6.WHEN SCALED, THIS DIMENSION |
| | IS GREATER THAN 12". |
| | |
| | 22.)COMBUSTIBLES NOT ALLOWED IN |
| | CONCEALED SPACES (2X4 BLOCKING) IN TYPE |
| | I, II AND IV CONSTRUCTION EXCEPT AS |
| | ALLOWED IN FBC707.1 AND FBC CHAPTER 8. |
| | |
| | 23.)A8.0, ELEVATIONS SHOW STUCCO.IS |
| | THIS EXISTING CONDITIONS OR NEW STUCCO? |
| | IF THIS IS NEW, PROVIDE A WALL SECTION. |
| | |
| | 24.)PROVIDE INTERIOR FINISH |
| | CLASSIFICATION FBC803.2. |
| | |
| | |
| | WHEN RESUBMITTING, REPLACE ONLY SHEETS |
| | WHICH HAVE CHANGED.SUBMIT OLD SHEETS |
| | SEPARATELY.TO EXPEDITE PLAN REVIEW, |
| | PROVIDE A TRANSMITTAL LETTER INDICATING |
| | HOW EACH ITEM WAS ADDRESSED. |
| | |
| | |