| Plan Review Stops For Permit 05041364 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2006-06-24 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-06-24 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-06-24 |
Time |
08:27 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2006-06-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-06-16 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-06-16 |
Time |
06:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2006-05-01 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-05-01 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-05-01 |
Time |
12:06 |
Sent To |
PC |
|
| Notes |
| 2006-05-01 00:00:00 | 1) FBC 13-103.1.2 BEFORE A BUILDING | | | PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHETECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | | | | 2) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3) PLANS WHICH WERE BROUGHT IN UNDER THE | | | 2001 FBC CANNOT BE CHANGE TO 2004 CODE | | | DURING THE REVIEW PROCESS. SEE SHEET 2 | | | OF 6. WHICH REFERS TO THE 2004 CODE.SO | | | PLEASE CHANGE INFORMATION TO REFLECT THE | | | 2001 CODE. | | | | | | 4) THE PRODUCT APPROVAL FOR THE MODIFIED | | | ROOF INDICATES A WOOD INSULATED SYSTEM | | | HOWEVER, THE INFORMATION ON THE DRAWINGS | | | ABOUT THE ROOF (SHEET 2), DOES NOT | | | INDICATE ANY INSULATION. THE PRODUCT | | | APPROVAL HAS TO MATCH WHAT IS ON THE | | | DRAWINGS. READ THE APPROVED ASSEMBLY TO | | | BE SURE THAT IS THE TYPE WHICH WILL BE | | | INSTALLED. | | | | | | 5 ) 713.13(2) F.S.THE NOTICE OF | | | COMMENCEMENT MUST BE RE-RECORDED BECAUSE | | | THE DESCRIBED IMPROVEMENT OR | | | CONSTRUCTION DID NOT COMMENCE WITHIN 90 | | | DAYS OF RECORDING. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-01-27 |
Time |
09:02 |
Rev Time |
2.00 |
| Received By |
mjacobs |
Date |
2006-01-26 |
Time |
14:10 |
Sent To |
PC |
|
| Notes |
| 2006-01-26 00:00:00 | 1) PLEASE SEE NOTES FROM PREVIOUS REVIEW | | | WHICH WERE NOT ADDRESSED. | | | | | | 2) SOME OF THE PRODUCT APPROVALS ARE | | | MISSING THE NOA REPORTS.NOTE: THE | | | PRODUCT APPROVALS ARE INCOMPLETE IF THE | | | INSTALLATION INSTRUCTIONS ARE MISSING | | | FROM THE REPORTS. ALSO SOME PRODUCT WERE | | | NOT APPROVED WHEN THEY WERE SUBMITTED,SO | | | CHECK THE WEB-SITE FOR THE APPROVED | | | SHEETS.EG FL42-R2 WHICH WAS STILL | | | PENDING AT THE TIME OF SUBMITTAL. | | | HOWEVER, THIS PRODUCT HAS SINCE BEEN | | | APPROVED WHICH MEANS THAT THE APPROVED | | | SHEETS SHOULD REPLACE THOSE PENDING | | | SHEETS. CHECK ALL PRODUCT APPROVALS AND | | | MAKE SURE THEY HAVE APPROVED AND UPDATED | | | SHEETS,ALSO THE INSTALLATION REPORTS. | | | | | | 3) CHOOSE THE SYSTEM FROM THE PRODUCT | | | APPROVAL FOR THE MODIFIED ROOF. SEE | | | PAGES 6-32 AND INDICATE WHICH SYSTEM | | | WILL BE INSTALLED. | | | | | | 4) AGAIN SEE NOTES FROM PREVIOUS REVIEW. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-12-20 |
Time |
08:50 |
Rev Time |
2.50 |
| Received By |
mjacobs |
Date |
2005-12-20 |
Time |
06:09 |
Sent To |
PC |
|
| Notes |
| 2005-12-20 00:00:00 | | | | 1) IMPACT FEES. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE | | | ISSUED.PLEASE CALL (561) 233-5025 FOR | | | MORE INFORMATION. | | | | | | 2) FBC 13-103.1.2 BEFORE A BUILDING | | | PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHETECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | PROVIDE ENERGY CALCULATIONS AND | | | EQUIPMENT SIZING CALCULATIONS (MANUAL J) | | | AS REQUIRED BY THE 2001 FLORIDA ENERGY | | | EFFICIENTCY CODE FOR BUILDING CONSTRUC- | | | TION. | | | | | | 3) 471.023 F.S.CERTIFICATE OF | | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ENGINEER | | | PRACTICING UNDER A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING | | | ENGINEERING SERVICES, SHALL INCLUDE THE | | | CERTIFICATE OF AUTHORIZATION NUMBER. | | | ADD THE NUMBER TO EACH SHEET.THIS MAY | | | BE ADDED BY HAND. | | | | | | 4) FBC 1203.1 EVERY HABITABLE ROOM OF | | | BUILDINGS HEREAFTER ERECTED SHALL HAVE | | | ONE OR MORE WINDOWS, UNLESS OTHERWISE | | | SPECIFICALLY PROVIDED HEREIN, TO AFFORD | | | ADEQUATE LIGHT AND VENTILATION. SEE | | | BEDROOM NEXT TO NEW OFFICE.PG 1 OF 6. | | | | | | 5) 2001 FL BLD CODE, 1005.4: | | | PROVIDE EMERGENCY EGRESS WINDOWS IN | | | SLEEPING ROOMS WITH A MINIMUM NET CLEAR | | | OPENING HEIGTH OF 24" AND NET CLEAR | | | OPENING WIDTH OF 20" AND A NET CLEAR | | | OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR | | | OPENINGS ARE PERMITTED TO HAVE A NET | | | CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH | | | SHALL NOT BE MORE THAN 44 " ABOVE THE | | | FINISH FLOOR. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL (561) 805-6726 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-08-17 |
Time |
09:51 |
Rev Time |
1.75 |
| Received By |
mjacobs |
Date |
2005-08-17 |
Time |
06:53 |
Sent To |
PC |
|
| Notes |
| 2005-08-17 00:00:00 | 1) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2) SUBMIT EXISTING FLOOR PLAN SHOWING | | | EGRESS OPENINGS NEXT TO NEW | | | CONSTRUCTION. ALSO PLEASE SHOW ACCESS | | | FROM EXISTING STRUCTURE TO NEEW ENCLOSE | | | AREA. | | | | | | 3) PLEASE LOOK CLOSELY AT PAGE 1 OF 6 OF | | | THE TWO SETS OF PLANS AND SEE THAT ONE | | | OF THE DRAWINGS IS DIFFERENT FROM THE | | | OTHER. THE PLANS SHOULD BE IDENTICAL FOR | | | RECORDING PURPOSES. | | | | | | 4) ONE OF THE PRODUCT APPROVAL ISFOR A | | | 8' DOOR. WHERE WILL THIS DOOR BE USED? | | | PLEASE INDICATE ON THE PLANS THE SIZE | | | AND LOCATION OF EACH DOOR. | | | | | | 5) WHERE WILL THE AWNING WINDOW BE | | | INSTALLED? PLEASE INDICATE ON PLANS. | | | | | | 6) EACH PRODUCT APPROVAL NEEDS A STATE | | | COVER SHEET OR LOCAL PRODUCT APPROVAL. I | | | PUT A FEW COVER SHEETS IN THE PACKAGE | | | PLEASE MAKE SURE THAT EACH PRODUCT | | | APPROVAL HAS IT'S OWN COVER SHEET WHEN | | | RESUBMITTING. | | | | | | 7) FBC 13-103.1.2BEFORE A BUILDING | | | PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHITECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-05-17 |
Time |
09:01 |
Rev Time |
2.50 |
| Received By |
mjacobs |
Date |
2005-05-17 |
Time |
06:45 |
Sent To |
PC |
|
| Notes |
| 2005-05-17 00:00:00 | 5/17/05 | | | | | | 1) 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2) IMPACT FEES. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | | | 3) FBC 13-103.1.2BEFORE A BUILDING | | | PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHITECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | | | | 4) SUBMIT EXISTING FLOOR PLAN SHOWING | | | EGRESS OPENINGS NEXT TO NEW | | | CONSTRUCTION. ALSO PLEASE SHOW ACCESS | | | FROM EXISTING STRUCTURE TO NEW ENCLOSE | | | AREA. | | | | | | 5) THE TITLE BLOCK IS MISSING FROM SHEET | | | 6 OF 6. | | | | | | 6) PRODUCT APPROVALS ARE MISSING TEST | | | REPORTS. ALSO PLEASE SELECT THE PRODUCT | | | TO BE USED WITHEACH REPORT. YOU NEED | | | MORE THAN THE COVER SHEET. | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 ARE | | | REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-06-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-06-16 |
Time |
09:44 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-06-16 |
Time |
09:43 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-27 |
Time |
14:27 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-04-27 |
Time |
14:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-01-23 |
Time |
15:06 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-01-23 |
Time |
14:17 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-12-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-16 |
Time |
07:37 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-12-16 |
Time |
07:27 |
Sent To |
B |
|
| Notes |
| 2005-12-16 00:00:00 | | | | THE ENGINEER MUST COMPLY WITH 471 FS AND | | | 61G15-23.002 FAC. TITLE BLOCKS AND | | | CERTIFICATE OF AUTHORIZATION REQUIRED, | | | ALL SHEETS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-16 |
Time |
12:29 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-08-16 |
Time |
12:21 |
Sent To |
B |
|
| Notes |
| 2005-08-16 00:00:00 | | | | | | | THE DESIGNER MUST PRINT NAME AND SIGN | | | PLANS THEY ARE RESPONSIBLE FOR. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL | | | AS NOTED ON LAST REVIEW. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-05-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-10 |
Time |
18:21 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-11 |
Time |
06:44 |
Sent To |
B |
|
| Notes |
| 2005-05-11 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE HAND DRAWN CHANGES ON THE PLAN | | | ARE NOT ACCEPTABLE FOR RETENTION OR JOB | | | SITE REVIEWED PLAN PER 104.2.1.3 FBC. | | | | | | 2} A RECEPTACLE MUST BE ADDED TO THE | | | REAR OF THE BUILDING (IF NONE EXIST)PER | | | 210.52(E). | | | | | | 3} THE ENGINEER MUST ATTACH A TITLE | | | BLOCK TO THE PLANS PER 61G15-23.002. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-15 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-15 |
Time |
10:06 |
Sent To |
B |
|
| Notes |
| 2006-06-15 00:00:00 | TO "LMARTINEZ' DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-27 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-27 |
Time |
10:23 |
Sent To |
E |
|
| Notes |
| 2006-04-27 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-17 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-17 |
Time |
11:41 |
Sent To |
Z |
|
| Notes |
| 2006-04-17 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-22 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-22 |
Time |
12:07 |
Sent To |
E |
|
| Notes |
| 2006-01-22 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-10 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-10 |
Time |
10:08 |
Sent To |
E |
|
| Notes |
| 2005-12-10 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-11-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-23 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-23 |
Time |
08:22 |
Sent To |
Z |
|
| Notes |
| 2005-11-23 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-19 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-16 |
Time |
09:33 |
Sent To |
E |
|
| Notes |
| 2005-08-16 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-09 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-09 |
Time |
10:14 |
Sent To |
Z |
|
| Notes |
| 2005-08-09 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-10 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-10 |
Time |
14:41 |
Sent To |
E |
|
| Notes |
| 2005-05-10 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-03 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-03 |
Time |
11:15 |
Sent To |
B |
|
| Notes |
| 2005-05-03 00:00:00 | TO "MISC" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-04-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-20 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-20 |
Time |
16:31 |
Sent To |
Z |
|
| Notes |
| 2005-04-20 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
N |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-26 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-26 |
Time |
07:34 |
Sent To |
I |
|
| Notes |
| 2006-04-26 00:00:00 | NO CHANGES TO LAST APPROVED REVIEW | | | 12/7/05 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-07 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-07 |
Time |
16:39 |
Sent To |
I |
|
| Notes |
| 2005-12-07 00:00:00 | ADDITION MEETS THE FRONT & SIDE SETBACK | | | AND INTERIOR ACCESS TO MAIN STRUCTURE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-08-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-15 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-15 |
Time |
12:10 |
Sent To |
I |
|
| Notes |
| 2005-08-15 00:00:00 | DENIED, | | | 1. MUST HAVE ACCESS FROM THE MAIN TO | | | ADDITION (LIBRARY) AND EXISTING | | | RESIDENCE. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-04-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-04-29 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-04-28 |
Time |
17:10 |
Sent To |
I |
|
| Notes |
| 2005-04-29 00:00:00 | DENIED, | | | 1. MUST HAVE INTERIOR ACCESS FROM THE | | | ADDITION TO MAIN STRUCTURE AND MAIN | | | STRUCTURE TO ADDITION. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | 2005-04-28 00:00:00 | NEED A PLANNER OPINION REGARDING THE | | | ADDITION AND INTERIOR ENTRANCE. |
|
|