Plan Review Details - Permit 05041319
Plan Review Stops For Permit 05041319
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-05-31 Cont ID  
Sent By mjacobs Date 2005-05-31 Time 08:01 Rev Time 1.25
Received By mjacobs Date 2005-05-31 Time 06:51 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-05-16 Cont ID  
Sent By mjacobs Date 2005-05-16 Time 11:35 Rev Time 2.00
Received By mjacobs Date 2005-05-16 Time 09:37 Sent To PC
Notes
2005-05-16 00:00:00BUILDING PLAN REVIEW
 PERMIT:05041319
 ADD:8421 LEGEND CLUB DR.
 CONT:RICHARD HANNA BLDG-CONTRACTOR
 INC.
 TEL: (561)626-4046
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW:1ST
 ACTION:DENIED
  
 1) 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2) IMPACT FEES. THE PLANS SHALL BE TAKEN
 TO PALM BEACH COUNTY BUILDING DEPARTMENT
 FOR IMPACT FEE ASSESSMENT. THEY SHALL BE
 STAMPED AT THAT OFFICE AND A COPY OF THE
 PAID RECEIPT SUBMITTED TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
  
 3) THE PRODUCT APPROVALS SUBMITTED ARE
 MISSING THE STATE COVER SHEETS; AND THE
 ROOFING TILES STATE SHEET IS MISSING THE
 TEST REPORTS.PLEASE SUBMIT COMPLETE
 REPORTS FOR EACH PRODUCT.YOU ALSO NEED
 PRODUCT APPROVALS FOR U-LINTELS.
 PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003 ARE
 REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 BUILDING PLAN REVIEW
 MYRON JACOBS
 TEL: (561)805-6726
 FAX: (561)659-8026
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-04-29 Cont ID  
Sent By btrobaug Date 2005-04-29 Time 15:42 Rev Time 0.50
Received By btrobaug Date 2005-04-29 Time 15:27 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-05-27 Cont ID  
Sent By adarroug Date 2005-05-27 Time 10:14 Rev Time 0.00
Received By adarroug Date 2005-05-27 Time 10:14 Sent To B
Notes
2005-05-27 00:00:00TO "MJACOBS" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-04-28 Cont ID  
Sent By adarroug Date 2005-04-28 Time 13:07 Rev Time 0.00
Received By adarroug Date 2005-04-28 Time 13:07 Sent To E
Notes
2005-04-28 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By adarroug Date 2005-04-19 Time 15:51 Sent To  
Notes
2005-04-19 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-05-03 Cont ID  
Sent By prafter Date 2005-05-03 Time 09:12 Rev Time 0.50
Received By prafter Date 2005-05-03 Time 09:12 Sent To P
Notes
2005-05-03 00:00:00MECH. PLAN REVIEW:
  
 A/C CONTRACTOR TO SUBMIT A/C PLANS AND
 EQUIPMENT INFORMATION AT A/C PERMIT
 TIME.
  
 PAT RAFTER 561/805/6728 OR 805/6719
 PATTY KRAUSS.
  
 PLEASE CALL IF THEAR ANY QUESTIONS.

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-05-05 Cont ID  
Sent By kstevens Date 2005-05-05 Time 10:41 Rev Time 0.25
Received By kstevens Date 2005-05-05 Time 10:41 Sent To B1
Notes
2005-05-05 00:00:00NO PLUMBING WORK SHOWN OR PLUMBING PLANS
 SUBMITTED

Review Stop Z ZONING
Rev No 2 Status P Date 2005-05-26 Cont ID  
Sent By mmclean Date 2005-05-26 Time 15:49 Rev Time 0.00
Received By mmclean Date 2005-05-26 Time 15:49 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2005-04-28 Cont ID  
Sent By mmclean Date 2005-04-28 Time 11:03 Rev Time 0.00
Received By mmclean Date 2005-04-27 Time 18:22 Sent To I
Notes
2005-04-28 00:00:00DENIED,
 1. SITEPLAN AND SURVEY DOES NOT MATCH
 WITH SETBACKS.
 2. REAR SETBACK MUST BE 15FT.
 3. TOTAL SETBACK DOES NOT MATCH SURVEY
 27.88' AND FRONT SETBACK SURVEY SHOWS
 31'.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
2005-04-27 00:00:00GRACE TO GIVE OPINION REGARDING THE REAR
 SETBACK OF NEW CONSTRUCTION AND VERIFY
 THE SIDE SETBACK.