| Plan Review Stops For Permit 05041212 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-12-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-12-25 |
Time |
19:01 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-12-25 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2005-12-25 00:00:00 | REVISED A4.0 DATED 12/19/05 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-09-29 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-09-29 |
Time |
18:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-23 |
Time |
23:24 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-07-23 |
Time |
23:13 |
Sent To |
|
|
| Notes |
| 2005-07-23 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC. | | | | | | 2.)PROVIDE PRODUCT APPROVALS FOR THE | | | STOREFRONT GLASS.STATE OR LOCAL | | | PRODUCT APPROVALS REQUIRED IN ADDITION | | | TO THE EVALUATION OR TEST REPORT, | | | FAC9B72.IF PRODUCT APPROVALS ARE NOT | | | SUBMITTED PRIOR TO PERMIT ISSUANCE A | | | SEPARATE PERMIT WILL BE REQUIRED. | | | WWW.FLORIDABUILDING.ORG | | | | | | 3.)SEE PREVIOUS LIST, ITEM #5.THE | | | LOUNG SINKS A6 ARE TO COMPLY WITH | | | FBC11-4.24.THE CABINET DOORS ARE STILL | | | SHOWN ON THE DETAILS.PLEASE SEE FBC11 | | | FIGURE 32 AND REVISE. | | | | | | 4.)SEE ATTACHED FS553.80(2)(B). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-05-16 |
Time |
10:27 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-05-16 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2005-05-16 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PROVIDE MANEUVERING CLEARANCE ON | | | THE PLAN FOR DOOR 102, PUSH SIDE. | | | | | | 2.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVALS REQUIRED AS WELL AS TEST | | | REPORT WITH INSTALLATION INSTRUCTIONS OR | | | NOA, FAC9B72 (STOREFRONT WINDOW). | | | | | | 3.)IMPACT PROTECTION REQUIRED | | | FBC1606.1.4.IF THE STOREFRONT WINDOW | | | IS NOT IMPACT, SUBMIT PRODUCT APPROVALS | | | FOR SHUTTERS AND SHOW ON THE PLAN WHERE | | | THEY WILL BE STORED.IF THEY ARE STORED | | | VERTICALLY, PROVIDE A RACK DETAIL. | | | | | | 4.)THE SQUARE FOOTAGE ON THE ENERGY | | | CALC DOESN'T MATCH THE PLAN. | | | | | | 5.)THE LOUNGE SINKS A6 ARE TO COMPLY | | | WITH FBC11-4.24. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-01-30 |
Time |
14:56 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2006-01-30 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-12-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-12-08 |
Time |
09:24 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2005-12-08 |
Time |
09:12 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-04-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-26 |
Time |
16:01 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-04-26 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2005-04-26 00:00:00 | ***** PROVISO ****** | | | | | | | | | 1)NOTE:PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125% AND LARGEST MOTOR LOADS. | | | 215.3,230.42 ETC. | | | | | | REVISE LOAD CALCS BEFORE ROUGH. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-01-11 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-01-11 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-01-11 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2006-01-11 00:00:00 | REVISION DATED 11/14/05 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-05-10 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-10 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2005-05-10 00:00:00 | PASSED | | | | | | | | | 1) IN THE CITY OF WEST PALM BEACH, DUCT | | | SMOKE DETECTORS SHALL BE WIRED INTO THE | | | FIRE ALARM PANEL TO INITIATE A GENERAL | | | FIRE ALARM, NOT SUPERVISORY SIGNAL. | | | | | | 2) NEW FIRE ALARM SYSTEMS SUPERVISING A | | | SPRINKLER SYSTEM SHALL BE UL CERTIFIED | | | FOR CENTRAL STATION SERVICE. | | | | | | 3) SEPARATE SHOP DRAWING AND PERMITS ARE | | | REQUIRED FOR FIRE ALARM AND FIRE | | | SPRINKLER REMODELS. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 OR 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-01-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-13 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-13 |
Time |
16:39 |
Sent To |
M |
|
| Notes |
| 2006-01-13 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-22 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-22 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | TO "BOB"#7 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-10 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-10 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2006-01-11 00:00:00 | TO "COMM" BD#15 | | 2005-12-10 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-12-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-12-08 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2005-12-08 |
Time |
09:11 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-19 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-19 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2005-09-21 00:00:00 | TO "COMM" BD#3 | | 2005-09-19 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-08 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-08 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2005-07-18 00:00:00 | TO "COMM" BD#16 | | 2005-07-08 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-09 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-04-25 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2005-04-25 00:00:00 | TO "COMM" BD#45 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-01-31 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-01-31 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-01-23 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-01-23 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-22 |
Time |
16:26 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2005-12-22 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | MECH. REV. SUBMITTAL TO GO FROM SQUARE | | | DUCT TO ROUND. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-22 |
Time |
14:35 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2005-09-22 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2005-09-22 00:00:00 | APPROVED PER PER HAROLD MOSER 6-4-05 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-06-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-06-04 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-06-04 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2005-06-04 00:00:00 | REFER TO SECTION 601.4 EXCEPTION # 3 | | | HABITABLE ROOMS ONLEY SHALL BE REQUIRED | | | TO HAVE BALANCED RETURN AIR.BATHROOM OR | | | RESTROOMS ARE AN EXCEPTION. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-01-25 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-01-25 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-01-25 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2006-01-25 00:00:00 | RE-SUB |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-09-27 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-09-27 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-08 |
Time |
09:20 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-08-08 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2005-08-08 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | | | | A. FROM PREVIOUS REVIEW: COMMENT NUMBER | | | TO REFLECT NUMBER FROM FIRST REVIEW: | | | 3. CABINET DOORS ARE STILL SHOWN ON THE | | | THE DETAILS 1/A-6, D/A-6 & H/A-6. THE | | | CABINET DOORS ARE NOT ALLOWED IN THE | | | CLEAR FLOOR SPACE FOR THE SINKS. | | | 4. SHT A5.0 WALL TO BE NONABSORBENT PER | | | SECTION 1204.2. RESPONSE NOTED, BUT | | | REQUIREMENT TO USE WATER PROOF EPOXY | | | PAINT SHALL BE CALLED OUT IN THE FINISH | | | LEGEND OR FINISH NOTES. SECTION 104.2.1. | | | 5. SHT A6.0 DETAIL #1 TO REFLECT FIG. 31 | | | CHAPTER 11. INDICATE ALL MEASUREMENTS AS | | | SHOWN IN FIG. 31. (SEE DETAIL 13/A9.0) - | | | RESPONSE NOTED, BUT LAYOUT STILL DOES | | | NOT COMPLY. 27" MEASUREMENT FOR | | | CLEARANCE SHOWN ABOVE THE SINK. | | | **NEW COMMENT** SINK DEPTH TO BE 6-1/2" | | | MAXIMUM. PLEASE INDICATE ON DETAIL. | | | 11-4.24.4 | | | | | | NEW COMMENT: | | | 1B. SEE ATTACHED SHEET CONCERNING THE | | | DESIGN PROFESSIONAL AND FS 533.80(2)(B). | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-09 |
Time |
08:18 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2005-06-08 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2005-06-09 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | | | | 1. SHT A1.0 IN THE INSTALLATION OR | | | REMOVAL OF ANY PART OF THE DRAINAGE | | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. | | | SECTION 704.5 - ALL DEMO'D PIPING SHALL | | | BE INSPECTED PRIOR TO COVERING. | | | 2. SHT A3.0 MINIMUM FACILITIES TABLE | | | 403.1. 3 DRINKING FOUNTAINS ARE REQUIRED | | | BUT ONLY 2 ARE SHOWN. | | | 3. SHT A3.0 SHOW CLEAR FLOOR SAPCE FOR | | | ALL ACCESSIBLE FIXTURES IN THE TOILET | | | ROOMS AND LOUNGES. PER SECTIONS 11-4.16, | | | 11-4.19, 11-4.22, & 11-4.24. THE CLEAR | | | FLOOR SPACE FOR THE LOUNGE SINKS SHALL | | | BE FORWARD APPROACH AND EXTEND A MAXIMUM | | | OF 19" UNDERNEATH THE SINK. CABINET | | | DOORS ARE NOT APPROVED AS THEY WILL BE | | | IN THE CLEAR FLOOR SPACE OF THE FIXTURE. | | | OPENING UNDER THE SINK SHALL BE MINIMUM | | | OF 30" AND SHALL BE INDICATED ON PLANS. | | | 4. SHT A5.0 WALL TO BE NON-ABSORBENT PER | | | SECTION 1204.2. INDICATE HOW PAINTED GWB | | | WILL COMPLY WITH THIS REQUIREMENT. ROOMS | | | 119A, 120, 187, & 188. | | | 5. SHT A6.0 DETAIL #1 TO REFLECT FIG 31 | | | CHAPTER 11. TOE CLEARANCE 6" MAX, PLANS | | | TO 1'0". (SEE DETAIL 13/A9.0). | | | 6. SHT P0.1 DOMESTIC WATER ISOMETRIC, | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT IN THE CEILING AS SHOWN. PDI-WH 201 | | | - SANT. ISOMETRIC INDICATES ROOM 186, | | | BUT NEEDS TO BE FOR ROOM 188. PLEASE | | | CORRECT. SECTION 104.2.1. | | | 7. SHT P2.1 ANY PORTION OF THE DRAINAGE | | | SYSTEM INSTALLED UNDERGROUND SHALL BE | | | NOT LESS THAN 2" IN DIAMETER. THE | | | CONDENSATE LINES INDICATE 3/4", 1-1/4" & | | | 1-1/2" UNDERGROUND PIPING. SECTION 710.3 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|