| Plan Review Stops For Permit 05040920 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
N |
Date |
2005-12-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-12-28 |
Time |
09:55 |
Rev Time |
0.33 |
| Received By |
jgomez |
Date |
2005-12-28 |
Time |
09:55 |
Sent To |
M |
|
| Notes |
| 2005-12-28 00:00:00 | INFORMATION SUBMITTED IS NOT FOR A | | | FIREPLACE, BUT FOR A ROOM HEATER. | | | THEREFORE, UL 127 TESTING REQUIREMENTS | | | REQUIRED BY SEC. 2806 FBC 2001 DON'T | | | APPLY.SENT FOR MECHANICAL REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2005-12-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-12-21 |
Time |
17:57 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2005-12-21 |
Time |
17:57 |
Sent To |
M |
|
| Notes |
| 2005-12-21 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | | 1- NEED LISTED SEE THRU PRE FABRICATED | | | FIREPLACE AS SHOWN ON PLANS TESTED AND | | | MEETING THE REQUIREMENTS OF UL 127. | | | SECTION 2806.1.2 FBC 2001. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-09-08 |
Time |
14:09 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2005-09-08 |
Time |
14:09 |
Sent To |
PC |
|
| Notes |
| 2005-09-08 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- AS AGREED WITH G.C. A) APPLY FOR | | | SHUTTERS UNDER A SEPARATE PERMIT. | | | B) APPLY FOR NON-IMPACT SLIDING GLASS | | | DOOR UNDER A SEPARATE PERMIT. | | | 2- NEED COMPLETE SPECS FOR BBQ GRILL | | | INCLUDING MODEL & HOOD FOR EXTERIOR USE. | | | 3- PROVIDE PRODUCT APPROVAL FOR CASEMENT | | | WINDOWS WITH LEGIBLE DRAWINGS (WITHOUT | | | CUTTING INFORMATION ON TOP OR BOTTOM OF | | | PAGE) AND SPECIFY GLASS TYPE TO BE USED | | | TO VERIFY COMPLIANCE W/ DESIGN PRESSURES | | | 4- PROVIDE COMPLETE SPECS AND UL LISTING | | | FOR SEE THRU FIREPLACE AS SHOWN ON | | | PLANS. AND, PROVIDE COMBUSTION AIR CALCS | | | FOR MECHANICAL PLAN REVIEWER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-08-16 |
Time |
12:31 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-08-16 |
Time |
12:31 |
Sent To |
PC |
|
| Notes |
| 2005-08-16 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | 2- A) PROVIDE COMPLETE SPECS & APPROVED | | | LISTING FOR GRILL. INCLUDING MODEL TO BE | | | USED. | | | | | | B) PROVIDE SPECS AND APPROVED LISTING | | | FOR HOOD SPECIFICALLY FOR EXTERIOR USE. | | | | | | 3- SLIDING GLASS DOOR PRODUCT APPROVAL | | | SUBMITTED DOESN'T MATCH DOOR ASSEMBLY AS | | | SHOWN ON PLANS. SEE PLANS AND RE-SUBMIT | | | FLORIDA OR LOCAL PRODUCT APPROVAL FOR | | | THAT SPECIFIC ASSEMBLY. | | | | | | 4- CLARIFY IF USING IMPACT GLASS OR | | | SHUTTERS. MIXED INFORMATION WAS | | | SUBMITTED. THERE IS A NOTE FOR STORM | | | SHUTTERS UNDER A SEPARATE PERMIT, WHILE | | | THERE ARE SOME PRODUCT APPROVALS WITH | | | IMPACT GLASS AND SOME OTHERS ARE NOT. | | | | | | 5- PRODUCT APPROVAL DRAWINGS FOR | | | CASEMENT WINDOWS ARE NOT CLEAR. THEY ARE | | | MISSING INFORMATION. PLEASE COPY | | | DRAWINGS THAT FIT IN THE SELECTED PAPER | | | WITHOUT CUTTING OUT INFORMATION. | | | | | | 6- PROVIDE FLORIDA/LOCAL PRODUCT | | | APPROVAL FOR ENTRY DOORS. | | | | | | 7- PROVIDE COMPLETE SPECS AND APPROVED | | | UL LISTING FOR SEE THRU FIREPLACE AS | | | SHOWN ON PLANS. SEC. 2806 FBC 2001. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-07-06 |
Time |
11:39 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-07-06 |
Time |
11:39 |
Sent To |
Z |
|
| Notes |
| 2005-07-06 00:00:00 | SECOND CHECKLIST: | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | 2- PROVIDE COMPLETE INFORMATION FOR | | | STORM SHUTTERS OR APPLY FOR A SEPARATE | | | PERMIT. | | | | | | 3- THE BUILDING OFFICIAL IS THE ONE WHO | | | APPROVES THE BBQ INSTALLATION. HE WANTS | | | TO SEE TESTING AND ENGINEERING | | | JUSTIFYING WHY PROPOSED INSTALLATION | | | DOESN'T NEED THE EXHAUST HOOD SINCE | | | THERE ARE OTHER COMPANIES WHO DESIGNED | | | BBQ'S FOR LANAI OR PORCH INSTALLATION | | | AND THEY REQUIRE HOOD EXHAUST. | | | LETTER SUBMITTED IS INSUFFICIENT AND IS | | | SIGNED BY NOBODY. BESIDES, MANUFACTURER | | | SPECS SAYS FOR OUTDOOR INSTALLATION ONLY | | | | | | 4- SHEET A3: A) REVISE/UPDATE TRUSS | | | ANCHOR SCHEDULE (NOT DONE FROM PREVIOUS | | | CHECKLIST). SEE LATEST CATALOGUE WHICH | | | WAS REVISED TO COMPLY WITH SECTION | | | 1609.4.3 FBC 2001. PROVIDE TESTING AND | | | ENGINEERING CALCS FOR NUMBER AND SIZE OF | | | NAILS THAT DIFFER FROM THOSE ALREADY | | | TESTED AND PUBLISHED BY MANUFACTURER. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | | | B) CONNECTOR THD210 IS A WOOD TO WOOD | | | CONNECTOR. NEED TO SPECIFY MASONRY | | | CONNECTOR. SEE CATALOGUE FOR PROPER | | | MASONRY CONNECTOR. | | | | | | C) SPECIFY CONNECTOR FOR TRUSS GIRDER | | | END AT INTERSECTION OF MASTER BEDROOM | | | AND CLUB ROOM CORNER. SEE PLANS. | | | | | | 5- A)SLIDING GLASS DOORS NOA AND FLORIDA | | | PRODUCT APPROVAL DON'T CORRESPOND TO | | | EACH OTHER. | | | B) NOA SUBMITTED IS FOR IMPACT DOORS. | | | ARE IMPACT DOORS GOING TO BE INSTALLED? | | | | | | 6- MULLIONS SPECIFIED FOR WINDOWS AT | | | LIVING ROOM DON'T RESIST CALCULATED | | | DESIGN PRESSURES. REVISE SIZE OF | | | MULLIONS AND PROVIDE PRODUCT APPROVAL | | | AS REQUIRED. | | | | | | 7- DADE COUNTY NOA SUBMITTED FOR | | | CASEMENT WINDOWS DOESN'T MATCH NOA | | | LISTED IN THE FLORIDA PRODUCT APPROVAL. | | | REVISE AS REQUIRED AND MAKE SURE IS THE | | | TYPE OF WINDOW ASSEMBLY TO BE INSTALLED. | | | | | | 8- REAR ELEVATION DOESN'T MATCH FLOOR | | | PLAN. REVISE LIVING ROOM WINDOW AND | | | CABANA BATH WING TO MATCH FLOOR PLAN. | | | | | | 9- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR IMPACT GLASS CASEMENT | | | WINDOW FOR BREAKFAST AREA. | | | | | | 10- PROVIDE ENERGY CALCULATIONS SHOWING | | | WORST CASE SCENARIO FOR THIS MODEL. | | | CALCULATIONS TO MATCH FLOOR PLAN. SEE | | | OVERHANG LENGTH AND HEIGHT, SIZES OF | | | WINDOWS/DOORS ETC. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-06-01 |
Time |
13:47 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-06-01 |
Time |
13:47 |
Sent To |
PC |
|
| Notes |
| 2005-06-01 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | 2- SHEET T1: A) UPDATE GENERAL NOTES. | | | SEE COMMENTS ON PLANS AND RETURN | | | REVIEWED SET AFTER CORRECTIONS ARE DONE | | | TO ORIGINAL DRAWINGS TO EXPEDITE REVIEW. | | | | | | 3- DESIGN PARAMETERS: CLARIFY WHERE IS | | | THE BASIC VELOCITY PRESSURE TAKEN FROM. | | | SEE SEC. 1606 FBC 2001. | | | ALSO, CLARIFY WHY THE MIN. SOIL BEARING | | | PRESSURE IS -NA? | | | | | | 4- PROVIDE COMPLETE INFORMATION FOR | | | STORM SHUTTERS OR APPLY FOR A SEPARATE | | | PERMIT. | | | | | | 5- SHEET A1: A) COLUMNS AT LANAI WERE | | | KEYED WRONG. THEY SHOULD BE C4 NOT C2. | | | SEE COMMENTS ON PLANS & REVISE AS REQ'D. | | | | | | B) DETAIL 4 DOESN'T MATCH FOOTING SHOWN | | | ON PLAN BETWEEN BEDROOM #2 AND GARAGE. | | | REVISE AS REQUIRED. | | | | | | 6- SHEET A2: A) SPECIFY SAFETY GLASS FOR | | | WINDOWS AT HER BATH, HIS BATH AND LIVING | | | ROOM. SEC. 2405.2 FBC 2001. | | | | | | B) CLARIFY NOTE #6. ARE WINDOWS AND | | | DOORS HAVING IMPACT GLAZING OR STORM | | | SHUTTERS?. SEE NOTE UNDER DESIGN | | | PRESSURES CHART AND REVISE AS REQ'D. | | | | | | 7- PROVIDE COMPLETE BBQ SPECS STATING | | | THAT GRILL IS DESIGNED TO BE INSTALLED | | | IN PORCH OR LANAI. SEC. 2808 FBC 2001. | | | | | | 8- SHEET A3: A) REVISE/UPDATE TRUSS | | | ANCHOR SCHEDULE. SEE LATEST CATALOGUE | | | WHICH WAS REVISED TO COMPLY WITH SEC. | | | 1609.4.3 FBC 2001. PROVIDE COMPLETE | | | ENGINEERING CALCULATIONS SHOWING | | | COMPLIANCE WITH SEC. 1609.4.3 FBC 2001 | | | FOR FASTENERS TYPE AND SPACING THAT | | | DIFFER FROM THOSE TESTED AND PUBLISHED | | | BY THE MANUFACTURER. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | B) CONNECTOR THD210 IS A WOOD TO WOOD | | | CONNECTOR. NEED TO SPECIFY WOOD TO | | | MASONRY HANGER. SEE CATALOGUE FOR PROPER | | | MASONRY CONNECTORS AND REVISE AS | | | REQUIRED. | | | | | | C) SPECIFY CONNECTOR FOR TRUSS GIRDER | | | END AT INTERSECTION OF MASTER BEDROOM | | | AND CLUB ROOM CORNER. SEE PLANS. | | | | | | 9- APPLY FOR LOCAL PRODUCT APPROVAL FOR | | | CORNER SLIDING GLASS DOORS. DADE COUNTY | | | NOA ALONE IS NOT AUTOMATICALLY A FLORIDA | | | PRODUCT APPROVAL. FILL OUT APPLICATION | | | FOR LOCAL PRODUCT APPROVAL. SEE | | | WWW.FLORIDABUILDING.ORG. | | | | | | 10- WINDOW AND DOOR MULLIONS: CLEARLY | | | INDICATE SIZE AND ANCHOR TYPE ACCORDING | | | TO ASSEMBLY TO VERIFY COMPLIANCE WITH | | | DESIGN PRESSURES. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 11- DADE COUNTY NOA SUBMITTED FOR | | | CASEMENT WINDOWS DOESN'T MATCH NOA | | | LISTED ON FLORIDA PRODUCT APPROVAL COVER | | | PAGE. REVISE AS REQUIRED. | | | | | | 12- PROVIDE COMPLETE LISTING FOR | | | FIREPLACE SHOWING COMPLIANCE WITH UL 127 | | | REQUIREMENTS. SEC. 2806 FBC 2001. | | | | | | *** PLEASE DON'T STAPLE PRODUCT | | | APPROVALS TO PLANS. IT WILL EXPEDITE | | | REVIEW PROCESS AND HANDLING OF PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-09-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-21 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-21 |
Time |
07:32 |
Sent To |
PC |
|
| Notes |
| 2006-09-21 00:00:00 | REDLINED, TWO AHU'S #3 BEING SHOWN, ONE | | | SHOULD BE #2. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-04-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-17 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-17 |
Time |
11:19 |
Sent To |
PC |
|
| Notes |
| 2006-04-17 00:00:00 | REDLINED | | | | | | | | | ** 110.26 FOR A/C DISC'S. | | | ** AFCI FOR SD'S AS NOTE MENTIONS TO | | | WIRE TO KITCHEN OR BATH LT CIRCUIT. | | | 210.12 | | | ** PANEL "A" SHOWS 50A BRKR TO PANEL | | | "C", HOWEVER LOAD AND SIZE OF PANEL "C" | | | IS 100A'S PER RISER AND PANEL SCHEDULE. | | | | | | | | | THE ABOVE ARE REDLINED AND NEEDS TO BE | | | CORRECTED WITH OTHER REV'S BEFORE ROUGH. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-25 |
Time |
12:25 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-04-25 |
Time |
12:25 |
Sent To |
M |
|
| Notes |
| 2005-04-25 00:00:00 | ** PROVISO ** | | | | | | 1)NOTE: PLEASE SEE POSSIBLE MISSING | | | RECEPT FOR 2' OF WALL. | | | 210.52 | | | | | | 2)NOTE: PLEASE SEE PANEL "C" SHOWN ON | | | RISER IS NOT SHOWN ON PLANS. | | | | | | PLEASE REVISE THE ABOVE ALONG WITH ANY | | | OTHER CHANGES BEFORE ROUGH ELECTRICAL | | | INSPECTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-15 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-15 |
Time |
16:31 |
Sent To |
E |
|
| Notes |
| 2006-09-15 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-14 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-14 |
Time |
16:37 |
Sent To |
E |
|
| Notes |
| 2006-04-14 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-16 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-16 |
Time |
13:38 |
Sent To |
B |
|
| Notes |
| 2005-11-16 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-01 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-01 |
Time |
14:43 |
Sent To |
B |
|
| Notes |
| 2005-09-01 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-02 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-02 |
Time |
08:26 |
Sent To |
B |
|
| Notes |
| 2005-08-02 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-28 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-28 |
Time |
11:07 |
Sent To |
Z |
|
| Notes |
| 2005-07-28 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-07 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-07 |
Time |
13:09 |
Sent To |
P |
|
| Notes |
| 2005-07-07 00:00:00 | TO "KSTEVENS" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-23 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-23 |
Time |
16:18 |
Sent To |
M |
|
| Notes |
| 2005-06-23 00:00:00 | TO "PKRAUSS" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-04-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-22 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-22 |
Time |
11:14 |
Sent To |
E |
|
| Notes |
| 2005-04-22 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-06-01 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2005-08-16 |
Time |
12:30 |
Sent To |
PC |
|
| Notes |
| 2005-04-15 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-22 |
Time |
14:42 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2005-12-22 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | | | | 1) COMBUSTION AIR CALCULATIONS HAVE BEEN | | | SUBMITTED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-28 |
Time |
08:10 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-06-28 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2005-06-28 00:00:00 | PROVISO:2ND REQUEST | | | PROVIDE COMBUSTION AIR CALCULATIONS FOR | | | THE VENTLESS FIREPLACE PRIOR TO | | | INPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-02 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-05-02 |
Time |
11:46 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-05-02 |
Time |
11:46 |
Sent To |
P |
|
| Notes |
| 2005-05-02 00:00:00 | MECH. PLAN REVIEW: | | | PROVIDE PRODUCT APPROVAL FOR GAS FIRE | | | PLACE WITH COMBUSTION AIR INFORMATION. | | | PAT RAFTER 561/805/6728 OR805/6719 | | | PATTY KRAUSS. | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-12 |
Time |
07:47 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-07-12 |
Time |
07:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-05-05 |
Time |
13:56 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-05-05 |
Time |
13:56 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-01 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-01 |
Time |
16:25 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-07 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-07 |
Time |
08:29 |
Sent To |
I |
|
| Notes |
| 2005-07-07 00:00:00 | DENIED - RESUB - NEW SURVEYS | | | 1. DOES NOT MEET THE SETBACK (SIDE). | | | 2. NOT APART OF THE MINOR PD AMENDMENT | | | FOR PARCEL FF. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-04-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-04-21 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-04-21 |
Time |
16:24 |
Sent To |
I |
|
| Notes |
|
|