Plan Review Details - Permit 05040760
Plan Review Stops For Permit 05040760
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-06-16 Cont ID  
Sent By lsmith Date 2005-06-16 Time 06:50 Rev Time 0.50
Received By lsmith Date 2005-06-16 Time 06:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-05-03 Cont ID  
Sent By lsmith Date 2005-05-03 Time 08:16 Rev Time 0.50
Received By lsmith Date 2005-05-03 Time 08:16 Sent To  
Notes
2005-05-03 00:00:00BUILDING PLAN REVIEW: FAILED
  
 PLANS SHOW HEAT PUMP. MFGRS. SPECS
 SUBMITTED ARE FOR GAS HEATER. PLS
 CLARIFY.
  
 VALUE OF THE PERMIT UNDERSTATED PER
 MARSHALL SWIFT COST GUIDE. ADDITIONAL
 FEES OF $207.45 DUE BEFORE A PERMIT CAN
 BE ISSUED.
  
 A NOTICE OF COMMENCEMENT MUST BE FILLED
 & SUBMITTED BEFORE A PERMIT CAN BE
 ISSUED.
  
 THE BACKFLOW PREVENTER HAS TO BE BY
 SEPARATE PERMIT, BY PLUMBING CONTRACTOR
 & IN PLACE BEFORE THE POOL CAN BE
 STARTED.
  
 SEE NOTES FROM PLUMBING PLAN REVIEW.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-07-27 Cont ID  
Sent By btrobaug Date 2005-07-27 Time 09:56 Rev Time 0.33
Received By btrobaug Date 2005-07-27 Time 09:49 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-07-12 Cont ID  
Sent By btrobaug Date 2005-07-12 Time 15:46 Rev Time 0.33
Received By btrobaug Date 2005-07-12 Time 15:09 Sent To P
Notes
2005-07-12 00:00:00 
 PLEASE SEE 310.16 #10 CU MUST BE
 PROTECTED BY 30 AMP OCP MAX. THE
 SCHEMATIC SHOWS #10 SUB-PANEL FEEDERS
 AND #10 ON A 40 AMP BREAKER.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-04-26 Cont ID  
Sent By btrobaug Date 2005-04-26 Time 17:53 Rev Time 0.33
Received By btrobaug Date 2005-04-26 Time 17:39 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-07-27 Cont ID  
Sent By adarroug Date 2005-07-27 Time 08:48 Rev Time 0.00
Received By adarroug Date 2005-07-27 Time 08:48 Sent To E
Notes
2005-07-27 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-06-27 Cont ID  
Sent By adarroug Date 2005-06-27 Time 11:10 Rev Time 0.00
Received By adarroug Date 2005-06-27 Time 11:10 Sent To P
Notes
2005-06-27 00:00:00TO "KSTEVENS" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-05-24 Cont ID  
Sent By adarroug Date 2005-05-24 Time 19:06 Rev Time 0.00
Received By adarroug Date 2005-05-24 Time 19:06 Sent To P
Notes
2005-05-24 00:00:00TO "KSTEVENS" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-04-26 Cont ID  
Sent By adarroug Date 2005-04-26 Time 14:35 Rev Time 0.00
Received By adarroug Date 2005-04-26 Time 14:35 Sent To E
Notes
2005-04-26 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-04-14 Cont ID  
Sent By adarroug Date 2005-04-14 Time 16:28 Rev Time 0.00
Received By adarroug Date 2005-04-14 Time 16:28 Sent To Z
Notes
2005-04-14 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-07-13 Cont ID  
Sent By jleech Date 2005-07-13 Time 13:38 Rev Time 0.50
Received By jleech Date 2005-07-13 Time 13:38 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-06-14 Cont ID  
Sent By kstevens Date 2005-06-14 Time 06:38 Rev Time 0.33
Received By kstevens Date 2005-06-14 Time 06:38 Sent To B
Notes
2005-06-14 00:00:00DENIED
 REFERENCE: FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A. FROM PREVIOUS REVIEW:
  
 1. IMPRESSION TYPE SEAL SHALL IMPRESS
 ALL THE INFORMATION REQUIRED FOR THE
 SEAL ONTO THE SHEETS SEALED. THE
 IMPRESSION ON MOST SHEETS IS NOT LEGIBLE
 AND CAN NOT BE READ. FAC 61G15-23.001
 AND FS 471.025.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-05-02 Cont ID  
Sent By kstevens Date 2005-05-02 Time 14:13 Rev Time 0.60
Received By kstevens Date 2005-05-02 Time 14:13 Sent To B
Notes
2005-05-02 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) PAGE 1 OF 7 POOL SPECIFICATIONS
 INDICATE A 5 HP HEAT PUMP, BUT MANUF.
 SPECIFICATION SHEET INDICATES A GAS POOL
 HEATER. PLEASE CORRELATE PLANS AND
 MANUF. SHEET.
 2) IMPRESSION TYPE SEAL SHALL IMPRESS
 ALL THE INFORMATION REQUIRED FOR THE
 SEAL ONTO THE SHEETS SEALED. THE
 IMPRESSION ON MOST SHEETS IS NOT LEGIBLE
 AND CAN NOT BE READ. FAC 61G15-23.001
 AND FS 471.025.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2005-04-25 Cont ID  
Sent By mmclean Date 2005-04-18 Time 12:45 Rev Time 0.00
Received By mmclean Date 2005-04-18 Time 12:45 Sent To I
Notes
***NONE***