Plan Review Details - Permit 05040742
Plan Review Stops For Permit 05040742
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-06-15 Cont ID  
Sent By alange Date 2005-06-15 Time 09:25 Rev Time 1.50
Received By alange Date 2005-06-15 Time 07:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-05-09 Cont ID  
Sent By alange Date 2005-05-09 Time 11:03 Rev Time 1.66
Received By alange Date 2005-05-09 Time 09:13 Sent To  
Notes
2005-05-09 00:00:00DENIED
  
 1.PLEASE SIGN OWNER/AGENT ON ENERGY
 CALCS.
  
 2.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR WINDOW MULLIONS.
 ALL PRODUCT APPROVALS SUBMITTED REQUIRE
 THE FOLLOWING TO BE ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-04-17 Cont ID  
Sent By btrobaug Date 2006-04-17 Time 10:02 Rev Time 0.50
Received By btrobaug Date 2006-04-17 Time 06:34 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-03-28 Cont ID  
Sent By btrobaug Date 2006-03-28 Time 06:50 Rev Time 0.33
Received By btrobaug Date 2006-03-28 Time 06:44 Sent To PC
Notes
2006-03-28 00:00:00 
  
 ALL CHANGES TO THE PLAN MUST BE MADE BY
 THE DESIGNER OF RECORD (ENGINEER) PER
 ARTICLE 471 FLORIDA STATUTED.
 WHITE OUT ON THE PLAN IS NOT ACCEPTABLE.
 RETURN THE PLANS TO THE ENGINEER TO BE
 REDRAWN AND RESUBMIT FOR REVIEW.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-04-29 Cont ID  
Sent By btrobaug Date 2005-04-29 Time 12:18 Rev Time 0.33
Received By btrobaug Date 2005-04-29 Time 11:58 Sent To P
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2005-04-13 Cont ID  
Sent By spalmer Date 2005-04-13 Time 11:42 Rev Time 0.15
Received By spalmer Date 2005-04-13 Time 11:42 Sent To  
Notes
2005-04-13 00:00:00OKAY PER NEELAM FATIMA

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-04-12 Cont ID  
Sent By adarroug Date 2006-04-12 Time 16:11 Rev Time 0.00
Received By adarroug Date 2006-04-12 Time 16:11 Sent To E
Notes
2006-04-12 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-03-24 Cont ID  
Sent By spalmer Date 2006-03-24 Time 17:40 Rev Time 0.00
Received By spalmer Date 2006-03-24 Time 17:40 Sent To E
Notes
2006-03-24 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-05-27 Cont ID  
Sent By adarroug Date 2005-05-27 Time 11:11 Rev Time 0.00
Received By adarroug Date 2005-05-27 Time 11:11 Sent To M
Notes
2005-05-27 00:00:00TO "PKRAUSS" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-04-27 Cont ID  
Sent By adarroug Date 2005-04-27 Time 16:32 Rev Time 0.00
Received By adarroug Date 2005-04-27 Time 16:32 Sent To E
Notes
2005-04-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-05-09 Cont ID  
Sent By alange Date 2005-05-09 Time 11:04 Rev Time 0.00
Received By alange Date 2005-04-15 Time 10:15 Sent To  
Notes
2005-04-15 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-05-28 Cont ID  
Sent By hmoser Date 2005-05-28 Time 10:56 Rev Time 0.00
Received By hmoser Date 2005-05-28 Time 10:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-05-02 Cont ID  
Sent By hmoser Date 2005-05-02 Time   Rev Time 0.00
Received By hmoser Date 2005-05-02 Time 14:59 Sent To B
Notes
2005-05-02 00:00:00PLAN DENIED
 1) YOU CAN NOT TIE 12IN.DUCT IN A 12X8
 CAN.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-06-14 Cont ID  
Sent By kstevens Date 2005-06-14 Time 06:55 Rev Time 0.25
Received By kstevens Date 2005-06-14 Time 06:54 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-05-02 Cont ID  
Sent By kstevens Date 2005-05-02 Time 13:38 Rev Time 0.50
Received By kstevens Date 2005-05-02 Time 13:38 Sent To M
Notes
2005-05-02 00:00:00DENIED
 REFERENCE; FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT A1 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS:
 A. TRAP REQUIRED FOR SHOWER SEC 1002.1
 B. SHOW ALL PIPE SIZES TABLE 710.1(1)
 C. WASH MACHINE TRAP SHALL CONNECT LOW
 ON THE STACK FOR STANDPIPE. SECTION
 1002.1 (SEE RED LINE CORRECTIONS ON ONE
 SET OF PLANS).
 2) INFORMATIONAL THE CLEANOUT OPPOSITE
 OF THE W/C IS NOT REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2005-04-26 Cont ID  
Sent By mmclean Date 2005-04-26 Time 18:02 Rev Time 0.00
Received By mmclean Date 2005-04-26 Time 18:02 Sent To I
Notes
***NONE***