Plan Review Details - Permit 05040709
Plan Review Stops For Permit 05040709
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-08-08 Cont ID  
Sent By alange Date 2005-08-08 Time 16:03 Rev Time 2.00
Received By alange Date 2005-08-08 Time 11:43 Sent To  
Notes
2005-08-08 00:00:00 
 DENIED
 COMMENT FROM FIRST REVIEW:
  
 4.BASED ON SBCCI BUILDING VALUATION
 DATA THE VALUE OF $47,000 IS TOO LOW.
 THE ROOM ADDITION ALONE IS
 451SQ.FT X $76.96 PER SQ.FT. = $34,700.
 PLUS THE COMPLETE RENOVATION OF THE
 EXISTING BUILDING INCLUDING A NEW SLAB
 ROOF FRAMING AND A COMPLETE INTERIOR
 DEMO AND REBUILD.
 RECALCULATE VALUE SUBMITTED AND PAY
 ADDTIONAL PERMIT FEES.
  
 NEW COMMENTS:
  
 A.EXISTING SLAB PERMIT 03040474 IS
 EXPIRED. NO FINAL INSPECTION IS SHOWN ON
 OUR RECORDS.
  
 B. FOOTING DESIGN SHALL BE A MINIMUM 16
 INCH FOOTING WITH 4" ABOVE GRADE AND 12
 INCHES BELOW GRADE AS MINIMUMS. FOOTING
 SHOW ON EXISTING PERMIT IS ONLY 12
 INCHES.FBC 1804.1.3
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-05-09 Cont ID  
Sent By alange Date 2005-05-09 Time 08:16 Rev Time 1.50
Received By alange Date 2005-05-09 Time 07:19 Sent To  
Notes
2005-05-09 00:00:00 
 DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME, ADDRESS AND LICENSE NUMBER
 ON EACH PAGE. THE ADDRESS AND LICENSE
 NUMBER ARE NOT WRITTEN ON EACH SHEET.
 FAC 61G15-25.002 (2) AND FS 471.025
  
 4.BASED ON SBCCI BUILDING VALUATION
 DATA THE VALUE OF $35,000 IS TOO LOW.
 THE ROOM ADDITION ALONE IS
 899SQ.FT X $76.96 PER SQ.FT. = $69,187.
 RECALCULATE VALUE SUBMITTED AND PAY
 ADDTIONAL PERMIT FEES.
  
 5.SUBMIT PRODUCT APPROVALS FOR STRAPS
 AND TIE-DOWNS.
 ALL PRODUCT APPROVALS SUBMITTED REQUIRE
 THE FOLLOWING TO BE ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 6.SHOW DETAIL FOR WOOD TRUSS
 CONNECTION.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-08-04 Cont ID  
Sent By btrobaug Date 2005-08-04 Time 13:53 Rev Time 0.50
Received By btrobaug Date 2005-08-04 Time 12:53 Sent To B
Notes
2005-08-04 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE ORIGINAL APPLICATION MUST BE
 SUBMITTED WITH THE PLANS.
  
 2} PLEASE VERIFY THE SCALE IS 1/8" AS
 NOTED.
  
 3} A RECEPTACLE NEEDS TO BE ADDED IN
 BEDROOM #FOR COMPLIANCE WITH 210.52
 (A)(1).
  
 4} THE #10 WIRE ON THE 60 AMP AHU
 BREAKER IS IN VIOLATION OF 310.16.
  
 PLEASE HAVE MR. ESPINOZA SIGN HIS NAME
 TO THE SEAL. IT APPEARS THIS SET IS
 INITIALLED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-04-27 Cont ID  
Sent By prafter Date 2005-08-04 Time 12:28 Rev Time 0.50
Received By btrobaug Date 2005-04-27 Time 07:32 Sent To P
Notes
2005-04-27 00:00:00 
 PROVISO
 ~~~~~~~
 PROVIDE A CORRECTED PANEL SCHEDULE PRIOR
 TO ROUGH INSPECTION.
  
 CORRET REDLINED ITEMS ON THE NEXT
 REVISED PLAN. SHOW ACTUAL LOCATION OF
 DEVICES ADDED TO PLAN.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-08-02 Cont ID  
Sent By adarroug Date 2005-08-02 Time 08:30 Rev Time 0.00
Received By adarroug Date 2005-08-02 Time 08:30 Sent To P
Notes
2005-08-02 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-21 Cont ID  
Sent By adarroug Date 2005-07-21 Time 16:06 Rev Time 0.00
Received By adarroug Date 2005-07-21 Time 16:06 Sent To Z
Notes
2005-07-21 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-04-22 Cont ID  
Sent By adarroug Date 2005-04-22 Time 11:00 Rev Time 0.00
Received By adarroug Date 2005-04-22 Time 11:00 Sent To E
Notes
2005-04-22 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-05-09 Cont ID  
Sent By alange Date 2005-05-09 Time 08:17 Rev Time 0.00
Received By alange Date 2005-04-13 Time 16:44 Sent To  
Notes
2005-04-13 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2005-08-04 Cont ID  
Sent By prafter Date 2005-08-04 Time 12:12 Rev Time 1.00
Received By prafter Date 2005-08-04 Time 12:12 Sent To E
Notes
2005-08-04 00:00:00MECH. PLAN REVIEW:
  
 1.PROVIDE FOR AUX. DRAIN PAN UNDER
 A.H.U. WITH DRAIN PROTECTION.
 2003 FBC/M 307.2.3.
  
 2. BEDROOMS REQUIRE BALLANCED R/A2003
 FBC/M 604.1 EXCEPTION #1 .
  
 3. MECH.PLAN NOTE PAGE B6,NO ATTACHED
 A/C CONT. PLAN.
  
 PAT RAFTER 561/805/6728 OR 805/6719
 PATTY KRAUSS.
  
 PLEASE CALL IF THEAR ANY QUESTIONS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status   Date 2005-05-02 Cont ID  
Sent By hmoser Date 2005-05-02 Time 14:58 Rev Time 0.00
Received By hmoser Date 2005-05-02 Time 14:58 Sent To B
Notes
2005-05-02 00:00:00PLAN DENIED
 1) PLEASE MARK DUCT SIZES ON PLAN.
 2) PLEASE SUMIT A COPY OF THE ARI PAGE
 SHOWING THE MODEL NUMBERS OF THE A/C
 EQUIPMENT,AND SHOWING SEER.
 3) SHOW BATHROOM EXHAUST FANS AND
 TERMINATION OF FANS ON MECHANICAL PLANS.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-08-04 Cont ID  
Sent By jleech Date 2005-08-04 Time 10:38 Rev Time 0.33
Received By jleech Date 2005-08-04 Time 10:38 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-04-29 Cont ID  
Sent By kstevens Date 2005-04-29 Time 08:25 Rev Time 1.50
Received By kstevens Date 2005-04-29 Time 08:25 Sent To M
Notes
2005-04-29 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 BUILDING
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
 CITY WPB CODE
  
 1) SHT 6 SANITARY RISER DIAGRAM AND
 DRAIN PLAN DO NOT MEET CODE REQUIREMENTS
 FOR THE FOLLOWING:
 A. TUB NOT VENTED IN BATH #2 SECTION
 901.2.1.
 B. W/C IN BOTH BATHS SHALL NOT BE
 TRAPPED AS THERE IS AN INTEGRAL TRAP IN
 THE FIXTURE. SECTION 1002.1.
 C. LAVS IN BOTH BATHS TRAPS SHALL BE ON
 THE STACK NOT UNDERGROUND. SECTION
 1002.1.
 D. DRAIN PAN FOR THE WATER HEATER SHALL
 NOT CONNECT TO SANITARY, BUT SHALL DRAIN
 SEPARATELY OUTSIDE AND TERMINATE A
 MINIMUM OF 6" ABOVE GRADE, OR DRAIN TO
 AN INDIRECT WASTE RECEPTOR. SECTION
 504.8.2 - WATER HEATER PANS ARE NOT
 REQUIRED ON THE FIRST FLOOR. SECTION
 504.8.
 E. A/C CONDENSATE SHALL NOT DRAIN INTO
 THE SANITARY DRAINAGE SYSTEM, BUT SHALL
 DRAIN SEPARATELY TO THE OUTSIDE OF THE
 BUILDING MINIMUM 1 FOOT FROM THE
 STRUCTURE SIDEWALL. SECTION 1503.4.4 OF
 THE BUILDING CODE AND CITY CODE SECTION
 90-125(B).
 F. DRY HORIZONTAL VENT UPSTREAM OF THE
 W/C IN BATH #1 IS NOT APPROVED. SECTIONS
 905.3 & 905.4.
 2) SEE ATTACHED SHEET FOR AN EXAMPLE OF
 A SANT. RISER DIAGRAM THAT MEETS CODE
 REQUIREMENTS.
 3) ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME, ADDRESS, AND LICENSE NUMBER
 ON EACH SHEET. THE ADDRESS AND LICENSE
 NUMBER ARE NOT WRITTEN ON EACH SHEET.
 FAC 61G15-25.002(2) & FS 471.025.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2005-08-01 Cont ID  
Sent By mmclean Date 2005-08-01 Time 14:43 Rev Time 0.00
Received By mmclean Date 2005-07-29 Time 17:51 Sent To I
Notes
2005-07-29 00:00:00NEED TO HAVE SECOND OPINION FROM
 PLANNING.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-04-21 Cont ID  
Sent By mmclean Date 2005-04-21 Time 09:07 Rev Time 0.00
Received By mmclean Date 2005-04-21 Time 09:07 Sent To I
Notes
2005-04-21 00:00:00DENIED,
 1. MUST PROVIDE PLANS TO MEET THE 6
 PARKING SPACES FOR ADDRESS (TWO PARKING
 PER UNITS).
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720