| Plan Review Stops For Permit 05040596 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-28 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-06-28 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2005-06-28 00:00:00 | REVISION# 5JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-07 |
Time |
11:07 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-06-07 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-04-13 |
Time |
16:03 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2005-04-13 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2005-04-13 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05040596 | | | ADD: 515 N FLAGLER DR# 700 | | | CONT: MJ SIMPSON CORP | | | TEL: (954)733-9980 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) 704.2.1.4 CORRIDOR PARTITIONS, | | | SMOKE STOP PARTITIONS, HORIZONTAL EXIT | | | PART- ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3) SEE DOOR FOR OFFICE #704. | | | 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. REQUIRES 18" ON THE PULL | | | SIDE. | | | | | | 4) TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-20 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-05-20 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2005-05-20 00:00:00 | **** PLANS DID NOT CONTAIN ELECTRICAL | | | FIRST TIME IN. | | | NO ELECTRICAL CONT SIGNED ON, APPEARS TO | | | BE CROSSED OFF. | | | PLEASE SEE PLANS NOW CONTAIN ONE EM LT | | | ADDED TO REFLECTED CEILING PLAN FOR FIRE | | | REVIEW COMMENT. NO ELECTRICAL PLANS | | | SUBMITTED. | | | | | | IF ELECTRICAL WORK IS BEING DONE, A | | | SEPARATE PERMIT APPLICATION AND PLANS | | | WILL BE REQUIRED FORELECTRICAL SCOPE | | | OF WORK. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-06-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-06-02 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-06-02 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-04-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-04-14 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-04-14 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2005-04-14 00:00:00 | 1) THE DOOR SWING ON THE EXISTING CLOSET | | | CAUSES AN OBSTRUCTION OF GREATER THAN | | | 1/2 THE WIDTH OF THE MEANS OF EGRESS. | | | | | | 2) AN EMERGENCY LIGHT WILL BE REQUIRED | | | IN THE COMMON AREA NORTH OF THE LOBBY. | | | | | | 3) AS NOTED ON THE PLANS, SEPARATE SHOP | | | DRAWING AND PERMITS ARE REQUIRED FOR THE | | | FIRE ALARM AND FIRE SPRINKLER REMODELS. | | | | | | 4) ALL CONSTRUCTION, ALTERATION AND | | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-27 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-27 |
Time |
11:12 |
Sent To |
B |
|
| Notes |
| 2005-06-27 00:00:00 | TO "JWITMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-10 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-10 |
Time |
15:11 |
Sent To |
P |
|
| Notes |
| 2005-06-10 00:00:00 | TO PAUL SCHMITZ DESK (PLUMBING LAST | | | REVIEW, TOOK OFF OF BOARD) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-05-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-25 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-05-13 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2005-05-24 00:00:00 | TO "COMM" BD#26 | | 2005-05-13 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-06-11 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-06-11 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-25 |
Time |
18:40 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-04-25 |
Time |
18:40 |
Sent To |
|
|
| Notes |
| 2005-04-25 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | | | | 1) SINKS IN CONFERENCE ROOM, 707, AND | | | COFFEE STATION, 702, SHALL BE ACCESSIBLE | | | PROVIDE THE FOLLOWING INFORMATION ON | | | EACH DETAIL SHEET A-3.0: | | | A. KNEE CLEARANCE 11-4.24.3 | | | B. SINK DEPTH 11-4.24.4 | | | C. CLEAR FLOOR SPACE 11-4.24.5, FORWARD | | | APPROACH REQUIRED AND SHALL EXTEND | | | MAXIMUM 19" UNDERNEATH THE SINK. | | | D. EXPOSED PIPES & SURFACES 11-4.24.6 | | | E. FAUCETS 11-4.24.7 | | | 2) PER BUILDING OFFICAL CABINET DOORS | | | SHALL NOT BE IN CLEAR FLOOR SPACE FOR | | | SINKS AND A CLEAR OPENING IS REQUIRED. | | | 3) SHOW A TURNING AREA IN THE COFFEE | | | STATION ROOM. SECTION 104.2.3. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|