Plan Review Details - Permit 05040596
Plan Review Stops For Permit 05040596
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-06-28 Cont ID  
Sent By jwitmer Date 2005-06-28 Time 07:32 Rev Time 0.00
Received By jwitmer Date 2005-06-28 Time 07:31 Sent To  
Notes
2005-06-28 00:00:00REVISION# 5JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-06-07 Cont ID  
Sent By jwitmer Date 2005-06-07 Time 11:07 Rev Time 0.77
Received By jwitmer Date 2005-06-07 Time 11:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-04-13 Cont ID  
Sent By jwitmer Date 2005-04-13 Time 16:03 Rev Time 1.55
Received By jwitmer Date 2005-04-13 Time 16:03 Sent To  
Notes
2005-04-13 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05040596
 ADD: 515 N FLAGLER DR# 700
 CONT: MJ SIMPSON CORP
 TEL: (954)733-9980
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) 704.2.1.4 CORRIDOR PARTITIONS,
 SMOKE STOP PARTITIONS, HORIZONTAL EXIT
 PART- ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 3) SEE DOOR FOR OFFICE #704.
 11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARENCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARENCES SHALL BE
 CLEAR & LEVEL. REQUIRES 18" ON THE PULL
 SIDE.
  
 4) TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2005-05-20 Cont ID  
Sent By dpalmer Date 2005-05-20 Time 16:35 Rev Time 0.00
Received By dpalmer Date 2005-05-20 Time 16:35 Sent To  
Notes
2005-05-20 00:00:00**** PLANS DID NOT CONTAIN ELECTRICAL
 FIRST TIME IN.
 NO ELECTRICAL CONT SIGNED ON, APPEARS TO
 BE CROSSED OFF.
 PLEASE SEE PLANS NOW CONTAIN ONE EM LT
 ADDED TO REFLECTED CEILING PLAN FOR FIRE
 REVIEW COMMENT. NO ELECTRICAL PLANS
 SUBMITTED.
  
 IF ELECTRICAL WORK IS BEING DONE, A
 SEPARATE PERMIT APPLICATION AND PLANS
 WILL BE REQUIRED FORELECTRICAL SCOPE
 OF WORK.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-06-02 Cont ID  
Sent By mwennerg Date 2005-06-02 Time 14:50 Rev Time 0.00
Received By mwennerg Date 2005-06-02 Time 14:45 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2005-04-14 Cont ID  
Sent By mwennerg Date 2005-04-14 Time 09:54 Rev Time 0.00
Received By mwennerg Date 2005-04-14 Time 09:54 Sent To  
Notes
2005-04-14 00:00:001) THE DOOR SWING ON THE EXISTING CLOSET
 CAUSES AN OBSTRUCTION OF GREATER THAN
 1/2 THE WIDTH OF THE MEANS OF EGRESS.
  
 2) AN EMERGENCY LIGHT WILL BE REQUIRED
 IN THE COMMON AREA NORTH OF THE LOBBY.
  
 3) AS NOTED ON THE PLANS, SEPARATE SHOP
 DRAWING AND PERMITS ARE REQUIRED FOR THE
 FIRE ALARM AND FIRE SPRINKLER REMODELS.
  
 4) ALL CONSTRUCTION, ALTERATION AND
 DEMOLITION TO COMPLY WITH NFPA 241.
  
  
 MIKE WENNERGREN, A/CAPTAIN
 WPBFR(561) 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-06-27 Cont ID  
Sent By adarroug Date 2005-06-27 Time 11:12 Rev Time 0.00
Received By adarroug Date 2005-06-27 Time 11:12 Sent To B
Notes
2005-06-27 00:00:00TO "JWITMER" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-06-10 Cont ID  
Sent By shill Date 2005-06-10 Time 15:11 Rev Time 0.00
Received By shill Date 2005-06-10 Time 15:11 Sent To P
Notes
2005-06-10 00:00:00TO PAUL SCHMITZ DESK (PLUMBING LAST
 REVIEW, TOOK OFF OF BOARD)

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-05-13 Cont ID  
Sent By adarroug Date 2005-04-25 Time 10:34 Rev Time 0.00
Received By shill Date 2005-05-13 Time 10:34 Sent To  
Notes
2005-05-24 00:00:00TO "COMM" BD#26
2005-05-13 00:00:00IN INCOMING AWAITING SPACE ON "COMM" BD

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-06-11 Cont ID  
Sent By pschmitz Date 2005-06-11 Time 08:38 Rev Time 0.00
Received By pschmitz Date   Time   Sent To PC
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-04-25 Cont ID  
Sent By kstevens Date 2005-04-25 Time 18:40 Rev Time 0.50
Received By kstevens Date 2005-04-25 Time 18:40 Sent To  
Notes
2005-04-25 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
  
 1) SINKS IN CONFERENCE ROOM, 707, AND
 COFFEE STATION, 702, SHALL BE ACCESSIBLE
 PROVIDE THE FOLLOWING INFORMATION ON
 EACH DETAIL SHEET A-3.0:
 A. KNEE CLEARANCE 11-4.24.3
 B. SINK DEPTH 11-4.24.4
 C. CLEAR FLOOR SPACE 11-4.24.5, FORWARD
 APPROACH REQUIRED AND SHALL EXTEND
 MAXIMUM 19" UNDERNEATH THE SINK.
 D. EXPOSED PIPES & SURFACES 11-4.24.6
 E. FAUCETS 11-4.24.7
 2) PER BUILDING OFFICAL CABINET DOORS
 SHALL NOT BE IN CLEAR FLOOR SPACE FOR
 SINKS AND A CLEAR OPENING IS REQUIRED.
 3) SHOW A TURNING AREA IN THE COFFEE
 STATION ROOM. SECTION 104.2.3.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]