Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-05-16 Cont ID  
Sent By jwitmer Date 2005-05-16 Time 13:54 Rev Time 0.77
Received By jwitmer Date 2005-05-16 Time 13:54 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-04-26 Cont ID  
Sent By jwitmer Date 2005-04-26 Time 17:36 Rev Time 0.00
Received By jwitmer Date 2005-05-16 Time 13:54 Sent To  
Notes
2005-04-26 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05040448
 ADD: 301 SOUTHERN BLVD
 CONT: BURKHARDT CONSTRUCTION
 TEL: (561)718-2602
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1A)FL BLD CODE 104.2.1.2*
 ADDITIONAL INFORMATION REQUIRED,
 PLANS DO NOT INDICATE WHERE THE NORTH
 PROPERTY LINE IS, NOTE THERE ARE (2)
 LOTS ADJOINED! NO UNITY OF TITLE.
  
 1B) INDICATE THE AMOUNT OF OPENINGS (SQ
 FT) ON THE FIRST FLOOR NORTH SIDE OF
 BUILDING. ALSO INDICATE THE LOCATION OF
 THE 2ND FLOOR ON ELEVATION. TABLE 600
 ALLOWABLE OPENINGS.
  
 1C) DEPENDING ON THE LOCATION OF THE
 PROPERTY LINE ( WITHIN 15') OPENING
 PROTECTIVES MAY BE REQUIRED, 705.1.1.2.
  
 2)BOTKINS PLANS PHOTO COPIED NOT
 ORIGINAL SIGNTURE NOR RAISED SEAL.
 PLANS, SPECIFICATIONS,REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 3) PROVIDE THE MINIMUM BLDG TYPE AND THE
 OCCUPANCY CLASSIFICATION? TABLE 500
  
 4)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2005-05-16 Cont ID  
Sent By jwitmer Date 2005-05-16 Time 13:53 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-04-14 Cont ID  
Sent By mwennerg Date 2005-04-14 Time 13:23 Rev Time 0.00
Received By mwennerg Date 2005-04-14 Time 13:23 Sent To  
Notes
2005-04-14 00:00:001) IF THE DOOR IS PART OF THE REQUIRED
 MEANS OF EGRESS, IT SHALL REMAIN OPEN
 WHEN THE BUILDING IS OCCUPIED, AND HAVE
 THE APPROPRIATE SIGN ADJACENT TO THE
 DOOR.
  
 2) THE DOOR SHALL NOT CONSTITUTE MORE
 THAN 1/2 OF THE REQUIRED MEANS OF
 EGRESS.
  
 3) THE DOOR IN THE FULL OPEN POSITION
 SHALL NOT OBSTRUCT FIRE SPRINKLER HEADS
 IF APPLICABLE.
  
  
 MIKE WENNERGREN, A/CAPTAIN
 WPBFR(561) 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-10 Cont ID  
Sent By adarroug Date 2005-05-10 Time 15:25 Rev Time 0.00
Received By adarroug Date 2005-05-10 Time 15:25 Sent To B
Notes
2005-05-10 00:00:00TO "JWITMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-05-16 Cont ID  
Sent By jwitmer Date 2005-04-26 Time 13:52 Rev Time 0.00
Received By jwitmer Date 2005-04-11 Time 16:06 Sent To  
Notes
2005-04-11 00:00:00TO "COMM" BD#29

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-05-16 Cont ID  
Sent By jwitmer Date 2005-05-16 Time 13:52 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-05-16 Cont ID  
Sent By jwitmer Date 2005-05-16 Time 13:52 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy