| Plan Review Stops For Permit 05040418 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-10-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-10-13 |
Time |
10:44 |
Rev Time |
1.77 |
| Received By |
jwitmer |
Date |
2005-10-13 |
Time |
10:23 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-09-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-09-15 |
Time |
12:24 |
Rev Time |
1.25 |
| Received By |
jwitmer |
Date |
2005-09-15 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2005-09-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05040418 | | | ADD: 1800 N FLORIDA MANGO RD | | | CONT: CARTER & BURGESS | | | TEL: (754)247-0047 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | PLAN REVIEW | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | *******CONTRACTOR TO SET MEETING WITH | | | J WITMER (561)805-6715************* | | | | | | ALL ITEMS LISTED BELOW ARE CONTRACTOR | | | ITEMS TO FOLLOW UP ON!!!!!!!!!!!!!!!! | | | | | | | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK OF | | | COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | NO PERMIT APPLICATION ONLY A SUBMITTAL | | | SHEET, SUBMITTAL SHEET INDICATES | | | RENOVATIONS & REMODELING SHOWROOMS & | | | SOME OFFICES. PLANS INDICATE EXTERIOR | | | WORK A NEW FACADE, RAMPS STAIRS AND | | | LOADING DOCK, ARE THESE ITEMS TO BE | | | INCLUDEDUNDER THIS PERMIT. | | | | | | 3) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) STOREFRONT A1.3 | | | DOORS | | | WINDOWS | | | MULLIONS | | | B) HANDRAILS | | | C) ROOFING ASSEMBLIES | | | D) STORM SHUTTERS | | | | | | 4) 1606.1.4(1) IN WIND BORNE DEBRIS | | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | | ASSUMED TO BE OPENINGS UNLESS SUCH | | | GLAZING IS IMPACT RESISTANT OR PROTECTED | | | WITH AN IMPACT RESISTANT COVERING MEET- | | | ING THE REQUIREMENTS OF SSTD 12, ASTM | | | E 1886 AND ASTM E 1996 OR MIAMI-DADE. | | | 1) GLAZED OPENINGS LOCATED WITHIN 30 FT | | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | | LARGE MISSLE TEST. | | | | | | 5)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-28 |
Time |
07:39 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-07-28 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2005-07-28 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05040418 | | | ADD: 1800 N FLORIDA MANGO RD | | | CONT: CARTER & BURGESS | | | TEL: (754)247-0047 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | PLAN REVIEW | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK OF | | | COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | NO PERMIT APPLICATION ONLY A SUBMITTAL | | | SHEET, SUBMITTAL SHEET INDICATES | | | RENOVATIONS & REMODELING SHOWROOMS & | | | SOME OFFICES. PLANS INDICATE EXTERIOR | | | WORK A NEW FACADE, RAMPS STAIRS AND | | | LOADING DOCK, ARE THESE ITEMS TO BE | | | INCLUDEDUNDER THIS PERMIT. | | | | | | 3) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) STOREFRONT A1.3 | | | DOORS | | | WINDOWS | | | MULLIONS | | | B) HANDRAILS | | | C) ROOFING ASSEMBLIES | | | D) STORM SHUTTERS | | | | | | 4) 1606.1.4(1) IN WIND BORNE DEBRIS | | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | | ASSUMED TO BE OPENINGS UNLESS SUCH | | | GLAZING IS IMPACT RESISTANT OR PROTECTED | | | WITH AN IMPACT RESISTANT COVERING MEET- | | | ING THE REQUIREMENTS OF SSTD 12, ASTM | | | E 1886 AND ASTM E 1996 OR MIAMI-DADE. | | | 1) GLAZED OPENINGS LOCATED WITHIN 30 FT | | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | | LARGE MISSLE TEST. | | | | | | 5)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-05-06 |
Time |
10:58 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2005-05-06 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2005-05-06 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05040418 | | | ADD: 1800 N FLORIDA MANGO RD | | | CONT: CARTER & BURGESS | | | TEL: (754)247-0047 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | PLAN REVIEW | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK OF | | | COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | NO PERMIT APPLICATION ONLY A SUBMITTAL | | | SHEET, SUBMITTAL SHEET INDICATES | | | RENOVATIONS & REMODELING SHOWROOMS & | | | SOME OFFICES. PLANS INDICATE EXTERIOR | | | WORK A NEW FACADE, RAMPS STAIRS AND | | | LOADING DOCK, ARE THESE ITEMS TO BE | | | INCLUDEDUNDER THIS PERMIT. | | | | | | 3)FBC* F102.2.4ROOF COVERINGS, ON | | | BUILDINGS LOCATED IN THE FIRE DISTRICT, | | | SHALL CONFORM TO THE REQUIREMENTS OF | | | CLASS A OR B ROOF COVERINGS, AS DEFINED | | | IN FBC 1505.ANNOTATE THE PLANS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 4) FBC* F102.2.7ARCHITECTURAL TRIM, ON | | | BUILDINGS LOCATED IN THE FIRE DISTRICT, | | | SHALL BE CONSTRUCTED OF APPROVED | | | NON-COMBUSTIBLE MATERIALS OR FIRE | | | RETARDANT TREATED WOOD.ANNOTATE THE | | | PLANS TO DEMONSTRATE COMPLIANCE. | | | | | | 5)FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) STOREFRONT A1.3 | | | DOORS | | | WINDOWS | | | MULLIONS | | | B) HANDRAILS | | | C) ROOFING ASSEMBLIES | | | | | | 6) 1606.1.4(1) IN WIND BORNE DEBRIS | | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | | ASSUMED TO BE OPENINGS UNLESS SUCH | | | GLAZING IS IMPACT RESISTANT OR PROTECTED | | | WITH AN IMPACT RESISTANT COVERING MEET- | | | ING THE REQUIREMENTS OF SSTD 12, ASTM | | | E 1886 AND ASTM E 1996 OR MIAMI-DADE. | | | 1) GLAZED OPENINGS LOCATED WITHIN 30 FT | | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | | LARGE MISSLE TEST. | | | | | | 7)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 8)1025.1 SINGLE EXIT FOR MERCANTILE IS | | | LIMITED AT 2250 SQ FT, INDICATE THE | | | SECOND EXIT, IF THROUGH THE OFFICE | | | (BUSINESS) PROVIDE THE LOCATION FOR | | | CLEAR PATH, MEANS OF EGRESS. ALSO | | | INDICATE EXIT LIGHTING. | | | | | | 9) IT APPEARS THAT THE EXIT DOORS FOR | | | THE MERCANTILE OCCUPANCY ARE HORIZONTAL | | | SLIDING DOORS, DOORS TO COMPLY WITH: | | | 10112.4.SHOW COMPLIANCE. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-09-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-03 |
Time |
16:41 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-09-03 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2005-09-03 00:00:00 | ** REDLINED PLANS** | | | | | | PLANS REFERENCE WRONG ELECTRICAL CODE. | | | WE ARE UNDER THE 2002 NEC. | | | | | | KEY NOTE ON E-1.0 #4 MENTIONS EXT/EM | | | LTS WIRED TO A-17. | | | PLEASE SEE 700.12E, WHICHREQUIRES THE | | | BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | | | | BOTH ABOVE REDLINED, NO CORRECTIONS | | | NEEDED AT THIS TIME. IF PLANS HAVE | | | REVISIONS DIRING CONSTRUCTION, PLEASE | | | MAKE CORRECTIONS AT THAT TIME. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-12 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-07-12 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | IN ELEC FOR REVIEW. | | | ************* UNSAT 2ND REVIEW ******* | | | | | | PLEASE SEE PLAN HAVE ONLY BEEN SUBMITTED | | | FOR "PLAN REVIEW" ONLY AND NOT FOT | | | PERMIT. | | | | | | ************************************ | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: NOTE #1 NO, PLEASE SHOW | | | CIRCUITING AND CORRELATE WITH PANEL | | | SCHEDULE. PLEASE SEE A NOTE WAS ADDED TO | | | COMPLY WITH NEC 2005 700.12E. | | | PLEASE SEE FBC 104.2.1 WHICH STATES THE | | | TECHNICAL CODES SHALL NOT BE QUOTED FOR | | | INFORMATION REQUIRED ON PLANS. | | | PLEASE SEE NEW NOTE: | | | PLEASE SEE PLANS MENTIONS 2005 NEC, WE | | | ARE CURRENTLY UNDER THE 2002 NEC. | | | | | | 2)NOTE: NOTE #2 OK. | | | | | | 3)NOTE: NOTE #3 NO, ? IT IS UNCLEAR | | | WHERE "SHOWROOM" WINDOW RECEPTS ARE? | | | SHEET A2.0 SHOWS WINDOWS ON ELEVATION. | | | PLEASE SEE 210.62,220.12 | | | | | | 4)NOTE: NOTE #4 OK, HOWEVER PLEASE SEE | | | PREVIOUS NOTE FOR ADJUSTMENT PER 220.12 | | | | | | 5)NOTE: NOTE #5 OK, NEW MAIN SHOWN. | | | | | | 6)NOTE: NOTE #6 NO, PLEASE SEE EQUIPMENT | | | GROUNDING CONDUCTOR STILL BEING SHOWN | | | BEFORE FIRST MEANS OF DISCONNECT(S). | | | 250.6,250.24. | | | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE SUBMIT ONE COPY OF OLD/VOIDED | | | SHEETS FOR REFERENCE ONLY. | | | | | | PLEASE SEE PLANS HAVE ONLY BEEN | | | SUBMITTED FOR "PLAN REVIEW". | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-04-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-21 |
Time |
12:51 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-04-20 |
Time |
20:06 |
Sent To |
|
|
| Notes |
| 2005-04-21 00:00:00 | ********* UNSAT *********** | | | | | | PLEASE SEE PLANS ONLY SUBMITTED FOR | | | "PLAN REVIEW " AT THIS TIME AND NOT | | | SUBMITTED FOR PERMIT. | | | | | | 1)NOTE: PLEASE INCLUDE ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH PANEL SCHEDULES | | | TO BE SUBMITTED. | | | PLEASE ALSO SEE 700.12E FOR CIRCUITING | | | OF EM/EXT LTS | | | 215.5 | | | | | | 2)NOTE: PLEASE PLACE AREA DESIGNATIONS | | | ON PLANS. | | | | | | 3)NOTE: PLEASE SEE 210.62 FOR POSSIBLE | | | "SHOW WINDOW" RECEPTS REQUIRED AND | | | PLEASE ALSO SEE 210.12 FOR LOAD | | | CALCULATIONS. | | | | | | 4 )NOTE: PLEASE SHOW LOAD CALCULATIONS, | | | PLEASE SHOW PER | | | 220.3,220.10,220.11,220.13 ETC. | | | PLEASE ALSO SHOW ALL CONTINUOUS LOADS | | | AT 125% PER 215.3,230.42 | | | | | | 5)NOTE: PLEASE SEE NEW A/C DISC'S | | | ATTACHED TO GUTTER NOW APPEAR TO MAINS | | | 4OF 5 AND 5OF 5? | | | PLEASE LABEL IF INDEED THIS IS THE CASE. | | | | | | 6)NOTE: PLEASE SEE 250.6,250.24, | | | EQUIPMENT GROUNDING CONDUCTORS ARE ONLY | | | INSTALLED AFTER THE FIRST MEANS OF | | | DISCONNECT. | | | | | | 7)NOTE: PLEASE BE SURE TO REMOVE ALL | | | OLD/VOIDED SHEETS FROM SETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | PLEASE ONLY SUBMIT ONE SET OF OLD SHEETS | | | FOR REFERENCE. | | | | | | PLEASE BESURE TO SEE ANY POSSSIBLE | | | COMMENTS FROM OTHER REVIEWER(S) WHICH | | | MAY AFFECT ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | 2005-04-20 00:00:00 | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2005-10-13 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-10-13 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-10-13 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2005-10-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-09-12 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-12 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2005-09-12 00:00:00 | 1. SEPERATE PLANS AND PERMITS REQUIRED | | | FOR FIRE SPRINKLER SYSTEM MODIFICATIONS. | | | | | | 2. NO EMERGENCY LIGHTS OR EXIT SIGNS | | | SHOWN IN EXISTING WAREHOUSE. IF | | | EXISTING ENSURE PROPER FUNCTION, IF | | | NONE, PLEASE INSTALL. | | | | | | 3. CARE SHOULD BE TAKEN NOT TO PAINT | | | ANY OF THE REQUIRED FIRE SPRINKLER | | | HEADS DURING PAINTING OPERATIONS. | | | | | | 4. BUILDING ADDRESS REQUIRED ON | | | PROPER ELEVATION. A MINIMUM OF AT | | | LEAST 6" HIGH NUMBERS ARE REQUIRED. | | | | | | 5. NEW HANDRAILS AND GUARDRAILS TO | | | MEET THE PRESCRIPTIVE STRENGTH | | | REQUIREMENTS OF BUILDING AND FIRE | | | CODE REQUIREMENTS. | | | | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | | | | 804-4709 PHONE | | | 804-4774 FAX |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-02 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-02 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2005-08-02 00:00:00 | PLAN REVIEW ONLY- OK |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-05-04 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-05-04 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-04 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2005-05-04 00:00:00 | 1) ALL CONSTRUCTION, ALTERATION AND | | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | 2) LIFE SAFETY, NFPA 101, 2003 EDITION | | | SHALL BE COMPLIED WITH. | | | | | | 3) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODELS. | | | | | | 4) EXTERIOR STAIRS LOCATED AT THE SOUTH | | | SIDE OF THE BUILDING ARE REQUIRED TO | | | HAVE HANDRAILS ON BOTH SIDES. | | | | | | 5) DOES THE SHOWROOM MEET CRITERIA TO | | | ALLOW FOR A SINGLE EXIT? | | | | | | 6) ADDITIONAL EXIT SIGNS MAY BE REQUIRED | | | IFNECESSARY AT THE TIME OF THE FIELD | | | INSPECTION. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 OR 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-05 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-05 |
Time |
17:57 |
Sent To |
B |
|
| Notes |
| 2005-10-05 00:00:00 | TO "JWITMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-30 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-30 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2005-08-30 00:00:00 | TO "COMM" BD#20 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-05 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-05 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | TO "COMM" BD#11 | | 2005-07-05 00:00:00 | WAITING FOR SPACE ON "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-26 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-04-07 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2005-04-07 00:00:00 | TO "COMM" BD#58 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-14 |
Time |
11:21 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-09-14 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2005-09-14 00:00:00 | PROVISO: | | | FAN SHUTDOWN BY DUCT SMOKE DETECTOR WITH | | | NOTIFICATION REQUIRED PER 2001 FBC(M) | | | 606.2.1 & 606.4.1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-25 |
Time |
09:04 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-07-25 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2005-07-25 00:00:00 | PLAN CHECK ONLY*******APPROVED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-05-23 |
Time |
12:55 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-05-23 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2005-05-23 00:00:00 | DENIED:PLAN CHECK ONLY | | | | | | 1.PLAN SHEET M2., RTU CURB DETAIL DOES | | | NOT INDICATE THE REQUIRED HEIGHT OF THE | | | CURB.PER 2001 FBC 1511.7, A MINIMUM OF | | | 8" ABOVE THE ROOF SURFACE IS REQUIRED. | | | | | | 2.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | WITH NOTIFICATION TO ALARM/STROBE IN | | | NORMALLY OCCUPIED AREAS. | | | | | | 3.INDICATE ACCESS TO EQUIPMENT LOCATED | | | ON THE ROOF.PRE 2001 FBC/M 306.5, | | | WHERE ACCESS TO EQUIPMENT LOCATED ON | | | ROOFS IS GREATER THAN 16 FT, A PERMANENT | | | MEANS OF ACCESS IS REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-05 |
Time |
07:19 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-08-05 |
Time |
07:19 |
Sent To |
|
|
| Notes |
| 2005-08-05 00:00:00 | CONNECTING TO EXISTING SANT. AND WATER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-26 |
Time |
16:38 |
Rev Time |
0.74 |
| Received By |
kstevens |
Date |
2005-05-26 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2005-05-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | | | | 1. PER TABLE 403.1 A DRINKING FOUNTAIN | | | AND A SERVICE SINK ARE REQUIRED. PLEASE | | | INDICATE IF THESE FIXTURES ARE EXISTING. | | | 2. SHT CVR CODE IN EFFECT IS FBC-2001 | | | NOT 2003 AS SHOWN. PLEASE CORRECT | | | APPLICABLE CODES. SECTION 104.2.1. | | | 3. SHTS A1.2 AND A1.3 (DETAIL #2) THE | | | FOLLOWING INFORMATION SHALL BE INDICATED | | | TO SHOW COMPLIANCE WITH SECTION 11-4.24 | | | AND ALL SUBSECTIONS: | | | A. KNEE CLEARANCE 11-4.24.3 | | | B. SINK DEPTH 11-4.24.4 | | | C. CLEAR FLOOR SPACE 11-4.24.5 SHALL BE | | | FORWARD APPROACH AND EXTEND MAXIMUM 19" | | | UNDERNEATH THE SINK. | | | D. EXPOSED PIPES AND SURFACES 11-4.24.6 | | | E. FAUCETS 11-4.24.7 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|