Plan Review Details - Permit 05040221
Plan Review Stops For Permit 05040221
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2005-05-04 Cont ID  
Sent By ptjomsto Date 2005-04-04 Time 14:04 Rev Time 0.00
Received By jhiggins Date 2005-04-04 Time 14:04 Sent To  
Notes
2005-04-04 00:00:00VACANT LOT/ADDRESS NEEDS TO BE ASSIGNED

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-12-02 Cont ID  
Sent By jgomez Date 2005-12-02 Time 15:01 Rev Time 3.00
Received By jgomez Date 2005-12-02 Time 14:07 Sent To PC
Notes
2005-12-01 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1- GARAGE SIDE DOOR AND STRUCTURAL
 CONNECTORS AS SHOWN ON PLANS TO BE
 SUBMITTED UNDER A SEPARATE AS AGREED
 WITH OWNER, MR. ALVAREZ. SEE FAX.
  
 2- ROOF LOADING CHART IN PAGE A7: THERE
 IS A TYPO ON TOTAL LOAD. REVISE AS REQ'D

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-09-12 Cont ID  
Sent By jgomez Date 2005-09-12 Time 10:59 Rev Time 2.00
Received By jgomez Date 2005-09-12 Time 10:59 Sent To Z
Notes
2005-09-09 00:00:00BUILDING REVIEW THIRD CHECKLIST:
 1- A) NOTICE OF COMMENCEMENT DESCRIPTION
 NEEDS TO SPECIFY CONSTRUCTION OF A NEW 2
 STORY HOUSE. ANOTHER INFORMATION WAS
 DESCRIBED, BUT THERE IS NOT INDICATION
 OF A NEW 2 STORY HOUSE. REVISE AS REQ'D.
  
 B) NOTICE OF COMMENCEMENT NEEDS TO BE
 RE-RECORDED. IT EXPIRES AFTER 90 DAYS OF
 RECORDING IF WORK IS NOT STARTED. FL
 STATUTE 713.13(1)(G).
  
 2- SETBACKS SHOWN IN SURVEY AND IN SHEET
 A1 SITE PLAN DON'T MATCH REVISE AS REQ'D
  
 3- A) ROOF LOADING CHART IN PAGE A7 WAS
 CHANGED AND NOW IT'S MISSING THE ATTIC
 LIVE LOAD OF 30PSF OR 10PSF IS USED FOR
 STORAGE OR NON STORAGE AS REQUIRED BY
 TABLE 1604.1 FBC 2001.
  
 B) WIND INFORMATION ON SHEET A1 CHANGED
 FROM FBC 2001 TO ASCE. NEED TO IDENTIFY
 WHICH EDITION OF ASCE WAS USED BECAUSE
 THE EDITION ADOPTED BY THE CURRENT
 BUILDING CODE IS ASCE 7-98.
  
 4- ROOF SHEATHING SPECS ON SHEET A7 WERE
 CHANGED. FASTENERS WERE CHANGED FROM 8D
 RING SHANK TO 8D COMMON NEED TO REVISE
 AGAIN TO COMPLY WITH TABLE 2306.1 OF
 CITY AMENDMENTS TO FBC 2001. PREVIOUS
 COMMENT WAS TO SPECIFY FASTENER SPACING
 FOR ZONE 3 AREAS TO COMPLY WITH CITY
 AMENDMENTS. FASTENER SPECIFED AT THAT
 TIME WAS OK.
  
 5- REVISE SPECS FOR CEILING INSTALLATION
 AT ENTRY AND REAR PORCH AS REQ'D BY ASTM
 C926 AND ASTM C1063. FROM PREVIOUS
 COMMENT INFORMATION WAS CHANGED FOR
 POWER ACTUATED FASTENERS, BUT NOR FOR
 HAND NAILED FASTENERS.
  
 6- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR:
 A) ENTRY DOORS. FLORIDA PRODUCT APPROVAL
 SUBMITTED IS FOR MODEL FD-6000 VINYL
 INSWING DOOR. DADE COUNTY NOA SUBMITTED
 IS FOR SWD-101 OUTSWING ALUMINUM DOOR.
 NEED MATCHING INFORMATION.
  
 B) FRENCH DOORS WITH AND WITHOUT
 SIDELITES. DADE COUNTY NOA REPORT AND
 DRAWINGS SUBMITTED DON'T MATCH. REVISE.
  
 C) GARAGE SIDE DOOR.
  
 D) SINGLE HUNG WINDOWS.
  
 E) WINDOW MULLIONS.
  
 F) GARAGE DOORS DESIGN PRESSURES WERE
 CHANGED. NOW NEEDS GARAGE DOORS THAT
 MEET THE CALCULATED DESIGN PRESSURES.
  
 7- SHEET A4: TOTAL AREA CALCULATIONS
 DON'T ADD UP CORRECTLY. REVISE AS REQ'D.
  
 8- CLARIFY IF USING THE 2ND FLOOR
 FRAMING PLAN AS A DIAPHRAGM TO RESIST
 THE LATERAL LOADS OR NOT. PROVIDE
 COMPLETE ENGINEERING CALCULATIONS
 SHOWING HOW DOES THE STRUCTURE COMPLIES
 WITH SECTIONS 2105 (LATERAL STABILITY)
 AND 2107 (LATERAL SUPPORT) OF FBC 2001.
 SEC. 104.2.1.2 CITY AMENDMETNS TO FBC
 2001.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-08-23 Cont ID  
Sent By jgomez Date 2005-08-23 Time 08:30 Rev Time 2.50
Received By jgomez Date 2005-08-23 Time 08:30 Sent To PC
Notes
2005-08-23 00:00:00BUILDING REVIEW 2ND CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 2- A) ROOF LOADING CHART IN PAGE A7:
 REVISE THE TOTAL LOAD. IT DOESN'T ADD
 UP.
  
 B) ROOF LOADING INFORMATION ON SHEET A7
 DOESN'T MATCH INFORMATION ON SHEET A1
 WIND INFORMATION. REVISE AS REQUIRED.
  
 C) WIND LOAD INFORMATION ON SHEET A1:
 MIN. LOAD SHALL BE 10PSF AS REQUIRED BY
 SEC. 1606.1.2 FBC 2001.
 *NOTE COORDINATE ALL 3 ITEMS ABOVE TO
 HAVE CONSISTENT INFORMATION.
  
 3- ROOF SHEATHING SPECS ON SHEET A7:
 ZONE 3 INCLUDES ALL CORNERS NOT JUST AT
 GABLE ENDS. SEE FIGURE 1606.2(C)FBC
 2001. REVISE SPECS AS REQUIRED.
  
 4- REVISE NOTE ON SHEET A5 REGARDING
 INSPECTION HOLES. 3/4" HOLES ARE TOO
 SMALL. SEE ACI 530 AND SPECIFY CORRECT
 SIZE FOR INSPECTION & CLEANOUT OPENINGS.
  
 5- REVISE SPECIFICATIONS FOR CEILING
 INSTALLATION AT ENTRY AND REAR PORCHES
 AND 2ND FLOOR BALCONIES. NAILS NEED TO
 BE LONG ENOUGH TO HAVE 1 3/4" MIN.
 PENETRATION TO THE HORIZONTAL MEMBERS.
 ALSO, REVISE NAILS SPACING. SEE ASTM
 C-926 AND ASTM C-1063. PROVIDE SPECIFIC
 SPECS FOR SIZE AND SPACING.
  
 6- SOIL TEST REPORT RECOMMENDS 18" MIN.
 FOOTING WIDTH AND 16" MIN. FOOTING DEPTH
 BELOW GRADE TO ACHIEVE THE 2500PSF
 BEARING CAPACITY OF THE SOIL. REVISE
 EITHER THE SOIL TEST REPORT OR
 FOUNDATIONS TO MATCH.
  
 7- CLARIFY WHY TIES ARE NOT REQUIRED FOR
 BEAM TB-5. HOW ARE THE 3 #6 REBARS TIED
 TOGETHER?. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 8- A) PROVIDE COMPLETE DETAILS FOR
 WINDOWS ATTACHMENT TO STEEL COLUMN AT
 MASTER BATHROOM. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 B) TAPCONS ARE NOT DESIGNED FOR USE IN
 METAL. REVISE AS REQUIRED.
  
 9- SPECIFY SMOKE DETECTOR ON FIRST FLOOR
 IN CLOSE PROXIMITY TO STAIRS. SEC.
 905.2.2 FBC 2001. ELEC. PLAN SHOW
 DETECTOR IN THE CEILING. THIS IS A TWO
 STORY FOYER. THEREFORE, THE DETECTOR IS
 ON THE 2ND FLOOR, NOT THE 1ST. REVISE.
  
 10- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL (DADE COUNTY NOA ALONE IS NOT
 AUTOMATICALLY AN STATE WIDE PRODUCT
 APPROVAL) FOR:
 A) ENTRY DOORS.
 B) FRENCH DOORS WITH AND WITHOUT
 SIDELITES AS SHOWN ON PLANS.
 C) GARAGE SIDE DOOR.
 D) SINGLE HUNG WINDOWS.
 E) WINDOW MULLIONS.
 F) ROOF TILE.
 G) TRUSS CONNECTORS SPECIFIED ON PLANS.
  
 11- STORM SHUTTERS: NEED TO PROVIDE AN
 EMERGENCY EGRESS. NOT ALL OPENINGS CAN
 BE CLOSED WITH SHUTTERS. SEE SEC.
 1005.4.5 FBC 2001.
  
 12- SHEET A1: UPDATE GENERAL NOTE
 REGARDING ACI 318. SEE CHAPTER 35 FBC
 2001 FOR PROPER EDITION.
  
 13- SPECIFY FIREBLOCKING MATERIAL IN
 STAIR SECTION. SEC. 2305.1.4 FBC 2001.
  
 14- REVISE WINDOW BUCK DETAIL. SEE SEC.
 1707.4.4.2 FBC 2001. NEED FULL SUPPORT
 FOR WINDOW. ALSO, THERE ARE 2 GARAGE
 DOOR BUCK DETAILS ON SAME PAGE.
  
 15- CLARIFY WHY FLOOR TRUSSES ARE NOT
 FASTENED. ARE THEY PART OF THE FLOOR
 DIAPHRAGM OR NOT?. HOW ARE THEY ATTACHED
 TO THE WOOD BEARING WALLS?. HOW ARE THEY
 SUPPORTED TO RESIST LATERAL LOADS? SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 16- OPENING DESIGN PRESSURES WERE
 CHANGED FROM PREVIOUS SUBMITTAL:
 A) PROVIDE ENGINEERED CALCS TO SHOW WHY
 THE DESIGN PRESSURES ARE THE SAME FOR
 LARGE AND SMALL OPENINGS. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 B) RIGHT ELEVATION: CLARIFY WHY DESIGN
 PRESSURES ARE HIGHER FOR 2ND FLOOR
 INTERIOR WINDOW THAN END WINDOW AT
 MASTER BATHROOM.
  
 17- ENERGY CALCULATIONS: A) OWNER/AGENT
 TO SIGN AND DATE BOTTOM OF FORM.
 B) COMPLETE TOP OF FORM: ADDRESS, OWNER
  
 18- SHEET A4: AREA CALCULATIONS WERE
 REVISED. NOW, 1ST AND 2ND FLOOR AREA
 DON'T ADD UP. REVISE AS REQUIRED.
  
 19- SHEET A5: WHERE IS DETAIL 3/A5 KEYED
 ON FOUNDATION PLAN.
  
 20- SHEET A6: 12"X8" DETAIL COLUMN CALLS
 FOR 3 #5 REINFORCEMENT, WHILE PICTURE
 SHOWS 2. REVISE AS REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-05-03 Cont ID  
Sent By jgomez Date 2005-05-03 Time 18:18 Rev Time 3.50
Received By jgomez Date 2005-05-03 Time 18:18 Sent To PC
Notes
2005-05-03 00:00:00BUILDING REVIEW CHECKLIST:
 1- PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING BACK STAMPED DRAWINGS AND PAID
 RECEIPT.
  
 2- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 3- SPECIFY 30PSF ATTIC LIVE LOAD AT
 ATTIC WITH STORAGE AREAS AND 10PSF ATTIC
 LIVE LOAD AT ATTIC WITHOUT STORAGE AREAS
 AS REQUIRED BY TABLE 1604.1 FBC 2001.
  
 4- REVISE ROOF SHEATHING FASTENING
 SPECS. SEE TABLE 2306.1 CITY AMENDMENTS
 TO FBC 2001 FOR TYPE OF NAIL AND SPACING
 TO BE USED ON ZONE 3 OF ROOF WHEN MEAN
 ROOF HEIGHT IS MORE THAN 25'-0". REVISE
 SPECIFICATIONS AND DETAILS AS REQUIRED.
  
 5- CONTRACTOR INSURANCE EXPIRED ON
 4-22-05. UPDATE AS REQUIRED.
  
 6- OWES $965.81 FOR UPDATED VALUATION
 AND RADON FEES.
  
 7- REVISE NOTES ON SHEET A4 AND A5
 REGARDING INSPECTION HOLES. 3/4" HOLES
 ARE TOO SMALL. SEE ACI 530 AND SPECIFY
 CORRECT SIZE FOR INSPECTION AND CLEANOUT
 OPENINGS.
  
 8- HALF BATH IN 1ST FL TO HAVE DOOR THAT
 ALLOWS 29" MIN. CLEAR OPENING REQ'D BY
 SEC. 11-11 FBC 2001. REVISE AS REQUIRED.
  
 9- SPECIFY ROOF TILE FASTENING AS
 REQUIRED BY SEC. 104.2.1.1 CITY
 AMENDMENTS TO FBC 2001.
  
 10- SPECIFY DRAFTSTOPPING MATERIAL AND
 LOCATION IN2ND FLOOR FRAMING PLAN AS
 REQUIRED BY SEC. 2305.2.2 FBC 2001.
  
 11- PROVIDE DETAIL/SPECS FOR CEILING
 INSTALLATION AT ENTRY AND REAR PORCHES
 AND AT SECOND FLOOR BALCONIES. SEE ASTM
 C926 AND ASTM C1063. SPECIFY FASTENER
 TYPE AND SPACING. SEC. 2504.2 FBC 2001.
  
 12- OMIT ALL DETAILS THAT DON'T APPLY TO
 THIS PROJECT TO EXPEDITE REVIEW PROCESS.
  
 13- PROVIDE COMPLETE BBQ SPECS THAT
 CLEARLY STATE THAT BBQ IS DESIGNED TO BE
 INSTALLED IN THE PORCH OR LANAI.
  
 14- PROVIDE SOIL TEST REPORT (2 COPIES).
  
 15- CLARIFY WHY HOOPS ARE NOT REQUIRED
 ON CONCRETE BEAMS SPECIFIED ON BEAM
 SCHEDULE? PROVIDE COMPLETE ENGINEERING
 ANALYSIS. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.
  
 16- PROVIDE COMPLETE DETAILS/SPECS FOR
 WINDOW ATTACHMENT TO STEEL COLUMN AT
 MASTER BATHROOM WINDOWS. SEE WINDOWS
 PRODUCT APPROVAL FOR APPROVED
 INSTALLATION. SECTION 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 17- SPECIFY SMOKE DETECTOR ON FIRST
 FLOOR IN CLOSE PROXIMITY TO STAIRS. SEC.
 905.2.2 FBC 2001.
  
 18- DADE COUNTY NOAALONE ARE NOT
 AUTOMATICALLY FLORIDA PRODUCT APPROVALS.
 NEED TO PROVIDE FLORIDA PRODUCT APPROVAL
 OR APPLY FOR LOCAL PRODUCT APPROVAL FOR:
 A) ENTRY DOORS.
 B) FRENCH DOORS (WITH AND WITHOUT
 SIELITES).
 C) GARAGE SIDE DOOR.
 D) GARAGE DOORS (SEE CALCULATED DESIGN
 PRESSURES ON PLANS).
 E) SINGLE HUNG WINDOWS.
 F) WINDOW MULLIONS.
 G) ROOF TILE.
 H) TRUSS CONNECTORS SPECIFIED ON PLANS.
 I) STORM SHUTTERS. SEE COMMENT BELOW.
  
 19- PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS INCLUDING KEY PLAN AND
 COMPLETE INSTALLATION SCHEDULE. SEE
 ATTACHED SAMPLE. AND CLEARLY MARK ON
 SHUTTER DRAWINGS SPECIFIC MOUNTING
 CONDITIONS AND ANCHOR TYPE AND SPACING
 TO BE USED ACCORDINGTO THE DESIGN
 PRESSURES, EDGE DISTANCE, PANEL SPAN,
 CONNECTION TYPE AND STRUCTURE TO BE
 ATTACHED TO (MASONRY OR CONCRETE).
  
 20- SHEET A1: A) UPDATE GENERAL NOTE
 REGARDING ACI 318. SEE CHAPTER 35 FOR
 PROPER YEAR REFERENCE.
  
 B) WIND INFORMATION:
 * WHERE IS THE BASIC VELOCITY PRESSURE
 TAKEN FROM? THERE IS NO TABLE SHOWN ON
 CHAPTER 16 FBC 2001.
  
 **CLARIFY WHY TOTAL ROOF DEAD LOAD IS
 5PSF?. SEE SEC. 1606.1.2 FBC 2001.
 ALSO, NEED TO CONSIDER ACTUAL WEIGHT OF
 DEAD LOAD. EG: ROOF TILE ETC. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 ***CLARIFY NOTE REGARDING 4' MIN. LENGTH
 NO OPENINGS BET. REINFORCED CELLS. WHICH
 ARE THE SHEARWALLS SINCE PLANS SHOW MANY
 OPENINGS BETWEEN 4' INTERVALS?. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 SEE COMMENTS ON REVIEWED SET OF PLANS.
  
 21- SPECIFY FIREBLOCKING MATERIAL IN
 STAIR SECTION AS REQUIRED BY SEC.
 2305.1.4 FBC 2001.
 NOTE: FIREBLOCKING AND DRAFSTOPPING ARE
 TWO DIFFERENT THINGS.
  
 22- SHEET A4: A) EGRESS WINDOW NOTES ARE
 INCORRECT. SEE SEC. 1005.4.4 FBC 2001
 AND REVISE AS REQUIRED.
  
 B) REVISE WINDOW/DOOR STRUCTURAL BUCK
 DETAIL. SEE SEC. 1707.4.4.2 FBC 2001 FOR
 PROPER BUCK INSTALLATION.
  
 C) PROVIDE STRUCTURAL GARAGE BUCK DETAIL
 TO RECEIVE GARAGE DOOR. SEE GARAGE DOOR
 PRODUCT APPROVAL.
  
 D) SPECIFY SAFETY GLASS IN MASTER
 BATHROOM WINDOWS. SEC. 2405.2.1 FBC 2001
  
 E) PROVIDE COMPLETE DETAIL/SECTION AT
 CONSTRUCTION OF CONNECTION BETWEEN WALL
 IN BEDROOM #3 & FRONT WINDOW. SEE PLAN.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
  
 F) SPECIFY WIDTH OF STAIRCASE.
  
 23- SHEET A5: A) TYP. 2 STORY WALL
 SECTION: * SPECIFY FIREBLOCKING IN WALL
 SECTION. SEC. 2305.1.4 FBC 2001.
  
 ** SPECIFY HOW FIRE CUT IS ACCHIEVED TO
 COMPLY WITH SEC. 2305.4 FBC 2001.
  
 *** SPECIFY VENT SIZE, LOCATION AND
 SPACING. SEC. 2309.7 FBC 2001.
  
 **** 12'X8" MASONRY COLUMN DETAIL AND
 SPECS BELOW IT DON'T MATCH. NUMBER OF
 REBARS TO MATCH. REVISE AS REQUIRED.
  
 ***** SPECIFY COLUMNS THAT ARE LOCATED
 AROUND SAIRWELL TO SUPPORT 2ND FLOOR
 FRAMING. ALSO, SPECIFY TOP AND BOTTOM
 CONNECTION. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 NOTE: SAME THING APPLIES TO DETAIL ON
 SHEET A6.
  
 24- SHEET A7: A) REVISE/UPDATE TRUSS
 ANCHOR SCHEDULE. SEE LATEST MANUFACTURER
 CATALOGUE FOR CORRECT UPLIFT AND LATERAL
 LOADS.
  
 B) PROVIDE COMPLETE ENGINEERING ANALYSIS
 SHOWING WHY 2ND FLOOR TRUSSES DON'T NEED
 TO BE FASTENED TO THE WALL. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 C) SPECIFY CONNECTORS AT THE ENDS OF ALL
 FLOOR TRUSSES.
  
 D) SPECIFY/CLARIFY HOW ARE TRUSSES
 INSTALLED ABOVE GARAGE AREA. SEE PLANS.
 DO THEY GO THRU THE MASONRY WALL TO FORM
 THE MANSARD? SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-11-01 Cont ID  
Sent By btrobaug Date 2006-11-01 Time 11:56 Rev Time 0.50
Received By btrobaug Date 2006-11-01 Time 11:19 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-10-20 Cont ID  
Sent By btrobaug Date 2006-10-20 Time 08:23 Rev Time 0.50
Received By btrobaug Date 2006-10-20 Time 07:08 Sent To PC
Notes
2006-10-20 07:40:52 
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK
 MUST SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002
 FAC.
  
 2} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT
 CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE
 EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS
 EQUAL TO OR GREATER THAN THE AVAILABLE FAULT.
  
 3} THE GROUNDS FROM THE METER TO BOTH FIRST MEANS OF
 DISCONNECT CREATE PARALLEL GROUND PATHS. REMOVE FROM
 PLAN.
  
 4} THE NOTE AT THE BOTTOM OF THE PANEL SCHEDULE
 INDICATES A 400 AMP SERVICE, THE SERVICE CONDUCTORS ARE
 250 MCM, WHICH IS ONLY RATED FOR 300 AMPS PER
 310.15(B)(6). PLEASE CORRELATE.
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-08-18 Cont ID  
Sent By btrobaug Date 2006-08-18 Time 12:38 Rev Time 0.50
Received By btrobaug Date 2006-08-18 Time 07:29 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-08-17 Cont ID  
Sent By btrobaug Date 2005-08-17 Time 11:48 Rev Time 0.50
Received By btrobaug Date 2005-08-17 Time 10:39 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-04-13 Cont ID  
Sent By btrobaug Date 2005-04-13 Time 13:07 Rev Time 0.75
Received By btrobaug Date 2005-04-13 Time 11:20 Sent To M
Notes
2005-04-13 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} LOAD CALCULATION PER 220.30 OR 220
 I,II AND III. 220.16, 220.18,
 210.11(C)(3) NOT ADDRESSED OR INCORRECT.
 2002 NEC.
  
 2} IF THE GROUND IS CARRIED TO THE
 DISCONNECTS FROM THE METER AN ISOLATION
 KIT MUST BE INSTALLED IN THE ENCLOSURE.
  
 3} THE FAMILY ROOM NEEDS A RECEPTACLE
 ADDED TO COMPLY WITH 210.52(A).
  
 4} THE WATER HEATER WAS NOT INCLUDED IN
 THE CALCS.
  
 5} A SMOKE DETECTOR IS REQUIRED ON THE
 FIRST FLOOR AT THE STAIR TO COMPLY WITH
 905.2.2 FBC 2001.
  
 6} A RECEPTACLE PER 210.63 MUST BE
 INSTALLED IN THE ATTIC FOR AHU SERVICE.
  
 7} ALL RECEPTACLES ON THE LANAI MUST
 COMPLY WITH 210.52(E)GFI.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-10-26 Cont ID  
Sent By adarroug Date 2006-10-26 Time 14:34 Rev Time 0.00
Received By adarroug Date 2006-10-26 Time 14:34 Sent To E
Notes
2006-10-26 14:35:09TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-08-17 Cont ID  
Sent By adarroug Date 2006-08-17 Time 14:33 Rev Time 0.00
Received By adarroug Date 2006-08-17 Time 14:33 Sent To E
Notes
2006-08-17 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-11-22 Cont ID  
Sent By adarroug Date 2005-11-22 Time 13:41 Rev Time 0.00
Received By adarroug Date 2005-11-22 Time 13:41 Sent To B
Notes
2005-11-22 00:00:00TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-08-31 Cont ID  
Sent By adarroug Date 2005-08-31 Time 16:07 Rev Time 0.00
Received By adarroug Date 2005-08-31 Time 16:07 Sent To B
Notes
2005-09-08 00:00:00SENT TO ZONING FIRSTLM
2005-08-31 00:00:00TO "JGOMEZ" DESK/RESUB
 BUILDING TO REVIEW 1ST AS PER LUIS
 MARTINEZ

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-08-17 Cont ID  
Sent By adarroug Date 2005-08-17 Time 09:43 Rev Time 0.00
Received By adarroug Date 2005-08-17 Time 09:42 Sent To E
Notes
2005-08-17 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-08-09 Cont ID  
Sent By adarroug Date 2005-08-09 Time 17:54 Rev Time 0.00
Received By adarroug Date 2005-08-09 Time 17:54 Sent To Z
Notes
2005-08-09 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-04-12 Cont ID  
Sent By adarroug Date 2005-04-12 Time 16:39 Rev Time 0.00
Received By adarroug Date 2005-04-12 Time 16:39 Sent To E
Notes
2005-04-12 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-05-04 Cont ID  
Sent By jgomez Date 2005-05-04 Time 14:12 Rev Time 0.00
Received By jgomez Date 2005-04-06 Time 10:30 Sent To  
Notes
2005-04-06 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2005-08-18 Cont ID  
Sent By tgordon Date 2005-08-18 Time 08:53 Rev Time 0.15
Received By tgordon Date 2005-08-18 Time 08:52 Sent To B
Notes
2005-08-18 00:00:00MECH. CONTRACTOR WILL APPLY FOR MECH.
 PERMIT.NEEDED AT THAT TIME.
 1.) MECH. PLANS .
 2.) MANUAL 'J' .
 ANY QUESTIONS CALL. TOM GORDON #805-6729
 OR PATTY KRAUSS # 805-6719 .

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-04-18 Cont ID  
Sent By hmoser Date 2005-04-18 Time   Rev Time 0.00
Received By hmoser Date 2005-04-18 Time 11:22 Sent To P
Notes
2005-04-18 00:00:00PLAN DENIED
 1) NO EQUIPMENT SCHEDULE ON THE PLAN.
 2)REFER TO SECTION 610.1.ABC.3.5.2 #1
 ACCESS TO EQUIPMENT AND NOTICE TO
 HOMEOWNER.FLORIDA ENERGY CODE
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-08-17 Cont ID  
Sent By jleech Date 2005-08-17 Time 12:59 Rev Time 0.00
Received By jleech Date 2005-08-17 Time 13:00 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-04-21 Cont ID  
Sent By kstevens Date 2005-04-21 Time 13:01 Rev Time 0.50
Received By kstevens Date 2005-04-21 Time 13:01 Sent To B1
Notes
2005-04-21 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1. SHT A9 SANT. RISER DIAGRAM DOES NOT
 REFLECT THE FLOOR PLAN, NOR DOES IT MEET
 THE CODE REQUIREMENTS. CORRECT THE
 FOLLOWING:
 A. WATER CLOSET IN THE 1/2 BATH IS NOT
 VENTED. SECTION 901.2.1.
 B. EXTRA LAV SHOWN ON THE RISER FOR
 BATH #4 2ND FLOOR. SECTION 104.2.1.
 C. SANT. RISER DIAGRAM DOES NOT REFLECT
 THE PIPING LAYOUT ON THE PLUMBING FLOOR
 PLAN. THE FLOOR PLAN PIPING DOES MEET
 CODE AND IF THE RISER DIAGRAM REFLECTS
 THE PIPING ON THE FLOOR PLAN, IT WILL
 MEET CODE REQUIREMENTS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop S SIGNS
Rev No 1 Status P Date 2005-12-02 Cont ID  
Sent By mmclean Date 2005-12-02 Time 14:21 Rev Time 0.00
Received By mmclean Date 2005-12-02 Time 14:21 Sent To B
Notes
2005-12-02 00:00:00PROVISO: BOTH SURVEY & SITEPLANS MEET
 THE ZONING SETBACK, BUT NEED TO MAKE
 SURE BOTH MATCH WITH SETBACKS.MUST
 PROVIDE A NEW SURVEY MATCHING THE
 SETBACKS OF THE SITEPLAN.
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 THE POOL/SPA/DECK.
 MUST PULL SEPERATE PERMIT FOR
 WALL/COLUMNS/FENCE/GATE WITH EASEMENT
 APPROVAL FROM CITY OF WEST PALM BEACH.
 12/2/05 RESTAMP REVISED PLANS AND GIVEN
 TO JULIO GOMEZ.

Review Stop Z ZONING
Rev No 3 Status P Date 2005-09-08 Cont ID  
Sent By mmclean Date 2005-09-08 Time 16:53 Rev Time 0.00
Received By mmclean Date 2005-09-08 Time 16:53 Sent To B
Notes
2005-09-12 00:00:00PROVISO: BOTH SURVEY & SITEPLANS MEET
 THE ZONING SETBACK, BUT NEED TO MAKE
 SURE BOTH MATCH WITH SETBACKS.MUST
 PROVIDE A NEW SURVEY MATCHING THE
 SETBACKS OF THE SITEPLAN.
2005-09-08 00:00:00NOTE: MUST PULL A SEPERATE PERMIT FOR
 THE POOL/SPA/DECK.
 MUST PULL SEPERATE PERMIT FOR
 WALL/COLUMNS/FENCE/GATE WITH EASEMENT
 APPROVAL FROM CITY OF WEST PALM BEACH.
  
 PLANS GIVEN TO LUIS MARTINEZ.

Review Stop Z ZONING
Rev No 2 Status F Date 2005-08-16 Cont ID  
Sent By mmclean Date 2005-08-16 Time 17:31 Rev Time 0.00
Received By mmclean Date 2005-08-16 Time 17:31 Sent To I
Notes
2005-08-16 00:00:00DENIED,
 1. TOO MUCH CONCRETE WITHIN THE FRONT
 SETBACK, MUST REDUCE TO MEET THE ZONING
 REQUIREMENTS.
 **NOTE** MUST MAINTAIN 1000SQ FT OR 75%
 OF LANDSCAPE WITHIN THE FIRST 25FT FRONT
 SETBACK.
 2. NEED TO PROVIDE THE DIMENSION FOR
 CONCRETE WALKWAY (LENGTH & WIDTH)
 4. MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/DECK/SCREEN ENCLOSURE.
 5. MUST PULL A SEPERATE PERMIT FOR
 WALL/FENCE/GATE WITH THE CITY OF WEST
 PALM BEACH UTILITY DEPT APPROVAL
 (EASEMENT CONSENT FORM - UTILITY).
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2005-04-11 Cont ID  
Sent By mmclean Date 2005-04-11 Time 16:27 Rev Time 0.00
Received By mmclean Date 2005-04-11 Time 16:27 Sent To I
Notes
2005-04-11 00:00:00DENIED,
 1. THE DIMENSION FOR LOT ON BOTH SURVEY
 & SITEPLAN DOES NOT MATCH
 2. ZONED SF7, SETBACK IN THE REAR MUST
 BE 10% OF LOT DEPTH OR 15FT WHICHEVER IS
 LESS.
 3. NEED TO PROVIDE THE DIMENSION FOR
 DRIVEWAY (LENGTH & WIDTH
 4. MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/DECK/SCREEN ENCLOSURE.
 5. MUST PULL A SEPERATE PERMIT FOR
 WALL/FENCE/GATE WITH THE CITY OF WEST
 PALM BEACH UTILITY DEPT APPROVAL
 (EASEMENT CONSENT FORM - UTILITY).
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720