| Plan Review Stops For Permit 05040125 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-06-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-06-17 |
Time |
09:05 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-06-17 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-05-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-05-31 |
Time |
10:13 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-05-31 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2005-05-31 00:00:00 | DENIED | | | | | | 1.EXTERIOR DOORS AND ROOFING REQUIRE | | | PRODUCT APPROVALS.PLEASE SUBMIT TWO | | | COPIES OF PRODUCT APPROVALS WITH QUALITY | | | ASSURANCE WITH THE FOLLOWING ATTACHED. | | | NOTE:ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING TO BE ATTACHED.TOWN AND | | | COUNTRY SHUTTERS AND PGT SGD-70 ARE | | | MISSING STATE APPROVALS. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-02 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-05-02 |
Time |
13:59 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2005-05-02 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2005-05-02 00:00:00 | DENIED | | | | | | 1.EXTERIOR DOORS AND ROOFING REQUIRE | | | PRODUCT APPROVALS.PLEASE SUBMIT TWO | | | COPIES OF PRODUCT APPROVALS WITH QUALITY | | | ASSURANCE WITH THE FOLLOWING ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 2. NOTE SEE RED LINE NOTES ON PLANS FOR | | | BATHROOM DOOR SIZE AND SEPERATE PERMITS | | | FOR FENCING, POOL AND DRIVEWAY. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-26 |
Time |
14:33 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-26 |
Time |
14:03 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-04-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-04-07 |
Time |
14:05 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2005-04-07 |
Time |
12:44 |
Sent To |
M |
|
| Notes |
| 2005-04-07 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} HOW IS THE "EXISTING" 100 AMP | | | SUB-PANEL, LOCATED AT THE GUEST | | | HOUSE,FED AND GROUNDED. ITS NOT SHOWN ON | | | THE RISER DIAGRAM. IS IT A SEPERATE | | | SERVICE? | | | | | | 2} PLEASE SUBMIT LOAD CALCULATIONS PER | | | ARTICLE 220 PART II, 220.30 OR 220.31. | | | | | | 3} IF AN EMERGENCY SYSTEM SUPPLIED BY A | | | GENERATOR IS TO BE PART OF THIS PERMIT, | | | PLEASE SUBMIT THE FOLLOWING. | | | A) MFGR'S SPECS. | | | B) INDICATE THE PRIME MOVER, AND HOW | | | STORED. | | | C) FEEDER CONDUCTOR SIZE. SEE 445.13. | | | D) THE CONDUIT CONNECTING THE METER AND | | | PANEL MUST BE REMOVED PER 700.6. | | | E) INDICATE FRAME GROUND. | | | | | | 4} THE HALL IN THE HOUSE NEEDS A | | | RECEPTACLE PER 210.52(H). | | | | | | 5} THE SMOKE DETECTOR IN THE KITCHEN | | | MUST BE REMOVED OR BE PE TYPE. | | | SEE8-4.1.2 NFPA-72. | | | | | | IF THERE ARE ANYQUESTIO0NS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-07 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-07 |
Time |
16:35 |
Sent To |
B |
|
| Notes |
| 2005-06-07 00:00:00 | TO AL DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-17 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-17 |
Time |
11:42 |
Sent To |
E |
|
| Notes |
| 2005-05-17 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-05-02 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-05-02 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-04-04 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2005-04-04 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-04-08 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-04-08 |
Time |
09:55 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-04-08 |
Time |
09:55 |
Sent To |
P |
|
| Notes |
| 2005-04-08 00:00:00 | MECH. PLAN REVIEW. | | | | | | PROVIDE A/C PLANS AND EQIPMENT | | | INFORMATION AT A/C PERMIT TIME. | | | | | | PAT RAFTER 805/6728 OR8056719 PATTY | | | KRAUSS. | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-04-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-18 |
Time |
17:50 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-04-18 |
Time |
17:50 |
Sent To |
B |
|
| Notes |
| 2005-04-18 00:00:00 | NO PLUMBING PLANS SUBMITTED - | | | INFORMATIONAL, A MINIMUM 60" FININSHED | | | MEASUREMENT REQUIRED FOR THE WATER | | | CLOSET AND BIDET FIXTURES IN ROOM. IT | | | SEEMS THAT THIS ROOM WILL BE TOO SMALL, | | | AS IT SEEMS TO BE ONLY 52". SECTION | | | 405.3.1. |
|
|