| Plan Review Stops For Permit 05031435 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-08-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-28 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-08-28 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2006-08-28 00:00:00 | ROOF TILE REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-06-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-17 |
Time |
12:00 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-06-17 |
Time |
12:00 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-05-02 |
Time |
16:55 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2005-05-02 |
Time |
16:55 |
Sent To |
PC |
|
| Notes |
| 2005-05-02 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- PAY IMPACT FEES. BRING BACK STAMPED | | | DRAWINGS AND PAID RECEIPT. | | | | | | 2- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | 3- DESIGNER OF RECORD TO SPECIFY ROOF | | | TILE FASTENING AS REQUIRED BY SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 4- WEST ELEVATION DON'T MATCH FLOOR | | | PLAN. SEE CORRIDOR BETWEEN FOYER AND | | | BEDROOM #3. REVISE AS REQUIRED. | | | | | | 5- PROVIDE COMPLETE SPECS AND DETAILS | | | FOR STRUCTURAL COLUMNS IN FOYER AREA. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | | | 6- ENTRY DOORS (101 AND 112) TO PROVIDE | | | 32" MIN. CLEAR OPENING PER LEAF AS REQ'D | | | BY TABLE 1004 FBC 2001. REVISE AS REQ'D. | | | | | | 7- NEED AT LEAST ONE BEDROOM WITH | | | BATHROOM DOOR THAT PROVIDES 29" MINIMUM | | | CLEAR OPENING AS REQ'D BY SEC. 11-11 FBC | | | | | | 8- PROVIDE COMPLETE DETAILS AND SPECS | | | FOR WOOD TRELLIS AT KITCHEN DECK. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 9- PROVIDE A/C CHASE DETAIL ON BEAM B-1. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | | | 10- CONNECTORS MTS18 AND MSTA21 DON'T | | | HAVE LATERAL LOADS. HOW ARE TRUSS | | | LATERAL LOADS RESISTED? SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | | | | 11- PROVIDE FLORIDA OR APPLY FOR LOCAL | | | PRODUCT APPROVAL FOR: | | | A) ENTRY DOORS. | | | B) SINGLE HUNG WINDOWS. | | | C) SPECIFY WHERE ARE THE THERMA-TRU | | | DOORS GOING TO BE INSTALLED. | | | D) KITCHEN DOOR. | | | E) FLAT ROOF SYSTEM. | | | F) ROOF TILE: NEED SBCCI REPORT THAT WAS | | | SUBMITTED FOR FLORIDA APPROVAL. | | | G) FRENCH DOORS. DADE COUNTY NOA ALONE | | | IS NOT FLORIDA PRODUCT APPROVAL. | | | | | | 12- PROVIDE COMPLETEFLUELESS FIREPLACE | | | LISTING AND SPECIFICATIONS AS REQUIRED | | | BY SEC. 2806 FBC 2001. | | | | | | 13- ENERGY CALCULATIONS: PROVIDE | | | COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING ADDRESS ETC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-06-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-16 |
Time |
21:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-16 |
Time |
21:01 |
Sent To |
PC |
|
| Notes |
| 2006-06-16 00:00:00 | **** UNSAT *** | | | | | | | | | 1) NOTE: PLEASE SEE PLANS CAN BE | | | REDLINED FOR MISSING LT FIXTURE REQUIRED | | | FOR EGRESS. 210.70 LS 101 7.8.1.3 | | | | | | 2) NOTE: CALLED SUSI FROM STERLING COMM | | | TO BRING IN 2ND SET OF SIGNED, AND | | | SEALED PLANS. | | | | | | 3) NOTE: PANEL SCHEDULE SHALL BE REVISED | | | BEFORE FINAL AND SUBMITTED FOR REVIEW TO | | | INDICATE ALL CIRCUITS AND ROOMS/AREAS IN | | | WHICH THEY FEED. 408.4 | | | | | | | | | THESE NEED TO BE VERIFIED FOR THE SAME | | | AS REV SUBMITTED AND REDLINED FOR NOTE | | | #1 AND #3 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-06-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-09 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-09 |
Time |
07:30 |
Sent To |
M |
|
| Notes |
| 2006-06-09 00:00:00 | ****** UNSAT ****** | | | | | | | | | ** PLEASE SEE THE FOLLOWING COMMENTS AS | | | THE RISER AND SERVICE DIAGRAM HAS | | | COMPLETELY CHANGED FROM THE ORIGINAL | | | PLANS SUBMITTED AND REVIEW. | | | | | | | | | 1) NOTE: PLEASE CORRELATE IDENTIFICATION | | | OF PANELS AND CORRELATE WITH RISER. | | | PLEASE SEE RISER SHOWS PANELS, A1, A2, | | | B, C, AND POOL PANEL, YET THE TWO 200A | | | PANEL SCHEDULES SUBMITTED ARE SHOWN AS | | | "A" AND "B"? | | | 215.5 | | | | | | 2) NOTE: PLEASE SEE PANEL "A" INDICATES | | | "FEED THRU LUGS" TO PANEL "B", YET RISER | | | SHOWS PANEL "B" COMING FROM THE | | | METER/MAIN PANEL.? | | | 215.5 | | | | | | 3) NOTE: PLEASE SEE NO PANEL SCHEDULE | | | FOR THE METER/MAIN 8 CIRCUIT SECTION WAS | | | SUBMITTED, YET THERE ARE ITEMS BEING FED | | | FROM THIS PANEL? | | | 215.5,408 | | | | | | 4) NOTE: PLEASE SEE SERVICE IS NOW | | | 400A'S AND THE SEC'S ARE STILL BEING | | | SHOWN FOR THE ORIGINAL 200A SERVICE?? | | | PLEASE INDICATE OF THE SEC'S ARE | | | INSTALLED BY FPL, OR IF THESE ARE SEC'S | | | INSTALLED TO A HAND HOLE WHICH WOULD | | | FALL UNDER 310.16,240.4,310.15B6 | | | IN THIS CASE, PLEASE SEE THE FOLLOWING | | | NOTE. | | | 215.5 | | | | | | 5) NOTE: PLEASE SEE THE GROUNDING | | | ELECTRODE CONDUCTOR WAS NOT INCREASED | | | FOR THE 400A SERVICE. | | | PLEASE SEE 310.15B6, 250.66 | | | MIN SIZE SHALL BE 1/0. | | | | | | 6) NOTE: PLEASE CORRELATE PANELS WITH | | | RISER AS RISER SHOWS THESE AS 32CIR AND | | | PANELS ARE SHOWN AS 42 CIRCUIT?? | | | 215.5 | | | | | | 7) NOTE: PLEASE SEE SD IN BEDRMS WITH | | | SLOPED CEILINGS SHALL MEET NFPA-72 BEING | | | INSTALLED WITHIN 3' OF THE PEAK ON A | | | SLOPED CEILING. | | | CHAPTER 8-1 INNFPA-72 99 OR CHAPTER 11 | | | IN NFPA-72 2002. | | | PLEASE SEE LOCATIONS ON PLANS WHICH NEED | | | TO BE ADJUSTED. | | | | | | 8) NOTE: PLEASE SEE KITCHEN COUNTER | | | SPACE MISSING GFI RECEPTS AS REQUIRED | | | PER 210.52C1-5, 210.8A6 | | | | | | 9) NOTE: PLEASE SEE RISER SHOWS A POOL | | | PANEL , YET PLANS DO NOT?? | | | PLEASE SHOW LOCATION. | | | 215.5 | | | | | | 10) NOTE: PLEASE SEE REAR EGRESS WHERE A | | | MIN OF ONE LT FIXTURE OF SOME TYPE WILL | | | BE REQUIRED FOR EGRESS. | | | 210.70, NFPA-101 7.8 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-01 |
Time |
09:56 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2005-05-31 |
Time |
17:41 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-04-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-01 |
Time |
07:10 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-03-31 |
Time |
16:47 |
Sent To |
M |
|
| Notes |
| 2005-04-01 00:00:00 | *********** UNSAT ************* | | | | | | 1)NOTE: PLEASE CORRELATE AHU'S ON | | | ELECTRICAL PLANS WITH MECH PLANS. | | | PLEASE SEE TWO #3 A/C SYSTEMS. PLEASE | | | SEE THESE ARE NOT ON MECH PLANS. | | | | | | 2)NOTE: PLEASE SEE WHIRLPOOL TUB IS | | | SHOWN ON PANEL SCHEDULE BUT NOT SHOWN ON | | | PLANS. | | | PLEASE ALSO SHOW GFI PROTECTION PER | | | 680.71. | | | PLEASE ALSO SEE THIS IS SHOWN AS 2-POLE | | | 20A. ONLY A NOTE: | | | | | | 3)NOTE: PLEASE SEE MEANS OF EGRESS | | | LIGHTING CONTROL AT BOTTOM OF STAIRS AT | | | FOYER LOCATION. SWITCH IS SHOWN AS | | | SINGLE POLE, IS THIS THE 3-WAY FOR | | | STAIRWAY? PLEASE ALSO SEE MEANS OF | | | EGRESS CONTROL REQUIRED FOR OUTER | | | STAIR/PORCH AREA BY BEDRM #4. 210.70, LS | | | 101 5-8. | | | | | | 4)NOTE: PLEASE SEE MISSING RECEPTS | | | REQUIRED PER 210.52 ALONG WALL/RAIL | | | AREAS IN STUDY AND MEZZ. PLEASE SEE RAIL | | | AREAS ARE CONSIDERED WALL SPACE. | | | | | | 5)NOTE: PLEASE SEE SD FOR INSIDE MASTER | | | BEDRM MUST BE WITHIN 3' OF PEAK OF | | | CEILING. IF CEILING HAS A LESSTHAN 3' | | | PEAK. SD IS STILL REQUIRED TO BE WITHIN | | | BEDRM. | | | NFPA-72 8-1.4, ETC. | | | | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-08-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-23 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-23 |
Time |
16:43 |
Sent To |
B |
|
| Notes |
| 2006-08-23 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-29 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-29 |
Time |
13:35 |
Sent To |
M |
|
| Notes |
| 2006-06-29 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-06-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-16 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-16 |
Time |
11:12 |
Sent To |
E |
|
| Notes |
| 2006-06-16 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-06 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-06 |
Time |
10:31 |
Sent To |
E |
|
| Notes |
| 2006-06-06 00:00:00 | TO "DPALMER' DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-13 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-13 |
Time |
16:44 |
Sent To |
Z |
|
| Notes |
| 2005-07-13 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
17:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
17:59 |
Sent To |
E |
|
| Notes |
| 2005-05-24 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-31 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-31 |
Time |
13:38 |
Sent To |
E |
|
| Notes |
| 2005-03-31 00:00:00 | TO "SFR""E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-02 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-25 |
Time |
08:17 |
Sent To |
Z |
|
| Notes |
| 2005-03-25 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-29 |
Time |
15:55 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-06-29 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2006-06-29 00:00:00 | REVISION TO MECH. PLANS PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-06-12 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-06-12 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-15 |
Time |
07:10 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-06-15 |
Time |
07:00 |
Sent To |
B |
|
| Notes |
| 2005-06-15 00:00:00 | PROVISO: | | | PLAN INDICATES GAS DRYER.PLEASE SUBMIT | | | CALCULATIONS FOR COMBUSTION AIR PRIOR TO | | | ROUGH INSPECTION. | | | | | | FLUELESS FIRE PLACE LOCATED IN THE | | | LOGGIA AREA - CLEARANCE FROM CEILING AND | | | SIDES SHALL COMPLY WITH THE | | | MANUFACTURER'S SUBMITTAL/INSTALLATION | | | INSTRUCTIONS ILLUSTRATED ON PAGE 7 & 8. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-05 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-04-05 |
Time |
07:27 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-04-05 |
Time |
07:27 |
Sent To |
P |
|
| Notes |
| 2005-04-05 00:00:00 | MECH. PLAN REVIEW. | | | | | | 1. PLEASE CORRECT FL. ENERGY | | | CALCULACTIONS TO REFLECT WHAT ON PLANS. | | | NOTE: (A) (B) (C) NATURAL GAS OR ELECT. | | | HEATING? | | | 2. PLEASE SUPPLY PRODUCT APPROVEL | | | INFORMATION ON FLUE-LESS FIRE | | | PLACE.IF GAS, CONBUSTION AIR IS | | | REQUIRED. | | | 3. GAS HOT WATER HEATER NOT REFLECTORED | | | ON ENERGY CALCULATIONS. | | | PAT RAFTER 8056728 OR 8056719 PATTY | | | KRAUSS. | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-04-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-01 |
Time |
09:56 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-04-07 |
Time |
17:17 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
|
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-21 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-21 |
Time |
15:45 |
Sent To |
PC |
|
| Notes |
| 2005-07-21 00:00:00 | APPROVING PAVERS FOR 20FT ACCESS | | | EASEMENT (REVISON). GIVEN TO WANDA. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-30 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-30 |
Time |
15:10 |
Sent To |
I |
|
| Notes |
| 2005-03-30 00:00:00 | NOTE: MUST PULL SEPERATE PERMIT FOR | | | POOL/SPA/DECK/SCREEN ENCLOSURE | | | NOTE: MUST PULL SEPERATE PERMIT FOR | | | WALL/FENCE/GATE WITH CITY OF WEST PALM | | | BEACH UTILITY DEPT EASMENT APPROVAL. |
|
|