Plan Review Details - Permit 05031311
Plan Review Stops For Permit 05031311
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-04-27 Cont ID  
Sent By lsmith Date 2005-04-27 Time 10:27 Rev Time 0.75
Received By lsmith Date 2005-04-27 Time 10:27 Sent To  
Notes
2005-04-27 00:00:00BUILDING PLAN REVIEW:
  
 NO ELECTRICAL CONTRACTOR SIGNED ON
 PERMIT APPLICATION
  
 A SEPARATE PERMIT WILL BE REQUIRED FOR
 THE FENCE & BUILDINGS SHOWN ON PLANS.
  
 ANY QUESTIONS PLEASE CALL
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2005-09-22 Cont ID  
Sent By dpalmer Date 2005-09-22 Time 16:00 Rev Time 1.00
Received By dpalmer Date 2005-09-22 Time 16:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2005-09-02 Cont ID  
Sent By dpalmer Date 2005-09-02 Time 19:01 Rev Time 0.33
Received By dpalmer Date 2005-09-02 Time 19:01 Sent To P
Notes
2005-09-02 00:00:00********* UNSAT 4TH REVIEW **********
  
 1)NOTE: PLEASE SEE PLANS SUBMITTED ONCE
 MORE WITH OUT ANY OF THE PREVIOUS
 COMMENTS ADDRESSED.
 PLEASE SEE PREVIOUS REVIEWS AND MAKE
 CORRECTIONS AND CHANGES AS NEEDED.
  
 2)NOTE: PLEASE SEE FS 553.80(2)(B) WITH
 RESPECT TO DESIGN PROFESSIONALS. IF
 PLANS COME BACK WITH OUT CORRECTIONS FOR
 FULL CODE COMPLIANCE, A 4X FEE WILL BE
 ACESSED AS REQUIRED UNDER FS AND PLANS
 WILL BE TURNED OVER TO THE FLORIDA BOARD
 OF PROFESSIONAL ENGINEERS FOR CODE
 COMPLIANCE REVIEW.
  
  
 PLEASE BE SURE ALL CORRECTIONS ARE MADE,
 PLEASE CORRELATE ALL PLANS SUBMITTED.
 PLEASE BE SURE ALL PLANS CORRECTED ARE
 SIGNED, DATED AND SEALED BY THE
 RESPECTIVE ARCHITECTS AND ENGINEERS.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS, IT
 IS STRONGLY SUGGESTED A PHONE CALL BE
 MADE TO SET UP A MEETING TO GO OVER ANY
 QUESTIONS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2005-07-20 Cont ID  
Sent By dpalmer Date 2005-07-20 Time 14:49 Rev Time 0.33
Received By dpalmer Date 2005-07-20 Time 14:49 Sent To P
Notes
2005-07-20 00:00:00********* UNSAT 3RD REVIEW ************
  
 1)NOTE: PLEASE SEE NOW A COPY OF
 "CLUBHOUSE ELECTRICAL PLANS" HAVE NOW
 BEEN SUBMITTED.
 PLEASE SEE THESE PLANS DO NOT CORRELATE
 WITH ELECTRICAL PLANS SUBMITTED FOR
 POOL.
 PLEASE SEE CLUBHOUSE PLANS SHOWS A NEW
 POOL PANEL, HOWEVER THIS DOES NOT
 CORRELATE WITH ELECTRICLA WIRING DIAGRAM
 AND POOL PANEL SUBMITTED BYBEA.???
  
 2)NOTE: PLEASE ALSO SEE ANY NOTES FROM
 PREVIOUS REVIEWS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION
 AFTER CORRECTIONS ARE MADE.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected].

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-06-15 Cont ID  
Sent By dpalmer Date 2005-06-15 Time 19:37 Rev Time 0.30
Received By dpalmer Date 2005-06-15 Time 19:33 Sent To P
Notes
2005-06-15 00:00:00********** UNSAT 2ND REVIEW ********
  
 PLEASE SEE NOTES FROM PREVIOUS REVIEW.
  
 1)NOTE: PLEASE SEE PLANS AND PERMIT
 APPLICATION INCLUDE A HEAT PUMP. THIS IS
 ALSO SHOWN ON A SUBMITTED 8 1/2 X 11
 SUBMITTED AND ATTACHED TO ELECTRICAL
 SHEET. PLEASE SEE THIS HEAT PUMP,WIRING
 ETC IS NOT INDICATED ON ELECTRICAL PLANS
 OR EQUIPMENT SCHEDULE??
 PLEASE SEE THIS IS NOT INCLUDED IN LOAD
 CALCS FOR POOL PANEL OR FEED TO NEW POOL
 PANEL.
  
 2)NOTE: PLEASE INCLUDE MANUFACTURE
 CUT/SPEC SHEETS FOR NEW HEAT PUMP
 SHOWING LISTING FROM A NRTL.
  
 3)NOTE: PLEASE REMOVE ANY AND ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-03-29 Cont ID  
Sent By dpalmer Date 2005-03-29 Time 11:53 Rev Time 0.30
Received By dpalmer Date 2005-03-29 Time 11:50 Sent To P
Notes
2005-03-29 00:00:00*********** UNSAT *****************
  
 1)NOTE: PLEASE SUBMIT A WIRING DIAGRAM
 FOR HOOK-UP OF ALL NEW ELECTRICAL
 EQUIPMENT.
 PLEASE SHOW WHERE NEW EQUIPMENT IS BEING
 FED FROM.
 CONDUITS,AWG, OCP ETC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-09-20 Cont ID  
Sent By adarroug Date 2005-09-20 Time 10:40 Rev Time 0.00
Received By adarroug Date 2005-09-20 Time 10:40 Sent To E
Notes
2005-09-20 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-08-31 Cont ID  
Sent By adarroug Date 2005-08-31 Time 15:49 Rev Time 0.00
Received By adarroug Date 2005-08-31 Time 15:49 Sent To E
Notes
2005-08-31 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-07-19 Cont ID  
Sent By adarroug Date 2005-07-19 Time 13:41 Rev Time 0.00
Received By adarroug Date 2005-07-19 Time 13:41 Sent To E
Notes
2005-07-19 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-06-09 Cont ID  
Sent By shill Date 2005-06-09 Time 17:11 Rev Time 0.00
Received By shill Date 2005-06-09 Time 17:11 Sent To E
Notes
2005-06-09 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-03-28 Cont ID  
Sent By adarroug Date 2005-03-28 Time 14:04 Rev Time 0.00
Received By adarroug Date 2005-03-28 Time 14:04 Sent To E
Notes
2005-03-28 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-03-23 Cont ID  
Sent By adarroug Date 2005-03-23 Time 16:03 Rev Time 0.00
Received By adarroug Date 2005-03-23 Time 16:03 Sent To Z
Notes
2005-03-23 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 4 Status P Date 2005-09-14 Cont ID  
Sent By jleech Date 2005-09-14 Time 13:58 Rev Time 0.50
Received By jleech Date 2005-09-14 Time 13:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2005-08-19 Cont ID  
Sent By kstevens Date 2005-08-19 Time 14:31 Rev Time 0.75
Received By kstevens Date 2005-08-12 Time 18:32 Sent To B1
Notes
2005-08-19 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 424 SWIMMING POOLS
 FBC-2001 CHAPTER 1
  
 A. COMMENTS FROM PREVIOUS REVIEW NOT
 ADDRESSED:
 1) PLANS SHALL BE ROUTED TO THE PALM
 BEACH COUNTY HEALTH DEPT. FOR REVIEW AND
 STAMPING PRIOR TO RESUBMITTING FOR
 REVIEW BY CITY WPB. SECTION 101.4.7.
 RESPONSE NOTED, BUT MR DUTCH HOLLAND
 FROM THE PLAM BEACH COUNTY HEALTH DEPT.
 INDICATES NO POOL PLANS ARE APPROVED
 UNLESS THEY ARE STAMPED BY THE HEALTH
 DEPT.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-06-27 Cont ID  
Sent By kstevens Date 2005-06-27 Time 18:40 Rev Time 0.50
Received By kstevens Date 2005-06-27 Time 18:40 Sent To  
Notes
2005-06-27 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 424 SWIMMING POOLS
 FBC-2001 CHAPTER 1
  
 A. COMMENTS FROM PREVIOUS REVIEW NOT
 ADDRESSED:
 1) PLANS SHALL BE ROUTED TO THE PALM
 BEACH COUNTY HEALTH DEPT. FOR REVIEW AND
 STAMPING PRIOR TO RESUBMITTING FOR
 REVIEW BY CITY WPB. SECTION 101.4.7.
 2) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 3) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUF. CUT SHEETS SUBMITTAL).
 4) A SKETCH OF ANY PROPOSED HEATER
 INSTALLATION INCLUDING VALVES,
 THERMOMETER, PIPE SIZES, AND MATERIAL
 SPECIFICATIONS SHALL BE INCLUDED IN THE
 APPLICATION FOR PERMIT PRIOR TO
 INSTALLATION. SECTION 424.1.6.5.14
 5) OVERFLOW FROM THE POOL SHALL DRAIN TO
 STORM, AND WASTE FROM THE FILTER SHALL
 DRAIN TO SANITARY. (INDICATE ON PLANS).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-04-12 Cont ID  
Sent By kstevens Date 2005-04-12 Time 08:32 Rev Time 1.00
Received By kstevens Date 2005-04-12 Time 08:32 Sent To B
Notes
2005-04-12 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 424 SWIMMING POOLS
 FBC-2001 CHAPTER 1
  
  
 1) PLANS SHALL BE ROUTED TO THE PALM
 BEACH COUNTY HEALTH DEPT. FOR REVIEW AND
 STAMPING PRIOR TO RESUBMITTING FOR
 REVIEW BY CITY WPB. SECTION 101.4.7.
 2) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 3) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUF. CUT SHEETS SUBMITTAL).
 4) A SKETCH OF ANY PROPOSED HEATER
 INSTALLATION INCLUDING VALVES,
 THERMOMETER, PIPE SIZES, AND MATERIAL
 SPECIFICATIONS SHALL BE INCLUDED IN THE
 APPLICATION FOR PERMIT PRIOR TO
 INSTALLATION. SECTION 424.1.6.5.14
 5) OVERFLOW FROM THE POOL SHALL DRAIN TO
 STORM, AND WASTE FROM THE FILTER SHALL
 DRAIN TO SANITARY. (INDICATE ON PLANS).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2005-03-25 Cont ID  
Sent By mmclean Date 2005-03-25 Time 16:22 Rev Time 0.00
Received By mmclean Date 2005-03-25 Time 16:22 Sent To I
Notes
***NONE***