| Plan Review Stops For Permit 05031311 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-04-27 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-04-27 |
Time |
10:27 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2005-04-27 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2005-04-27 00:00:00 | BUILDING PLAN REVIEW: | | | | | | NO ELECTRICAL CONTRACTOR SIGNED ON | | | PERMIT APPLICATION | | | | | | A SEPARATE PERMIT WILL BE REQUIRED FOR | | | THE FENCE & BUILDINGS SHOWN ON PLANS. | | | | | | ANY QUESTIONS PLEASE CALL | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-22 |
Time |
16:00 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-09-22 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-09-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-02 |
Time |
19:01 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-09-02 |
Time |
19:01 |
Sent To |
P |
|
| Notes |
| 2005-09-02 00:00:00 | ********* UNSAT 4TH REVIEW ********** | | | | | | 1)NOTE: PLEASE SEE PLANS SUBMITTED ONCE | | | MORE WITH OUT ANY OF THE PREVIOUS | | | COMMENTS ADDRESSED. | | | PLEASE SEE PREVIOUS REVIEWS AND MAKE | | | CORRECTIONS AND CHANGES AS NEEDED. | | | | | | 2)NOTE: PLEASE SEE FS 553.80(2)(B) WITH | | | RESPECT TO DESIGN PROFESSIONALS. IF | | | PLANS COME BACK WITH OUT CORRECTIONS FOR | | | FULL CODE COMPLIANCE, A 4X FEE WILL BE | | | ACESSED AS REQUIRED UNDER FS AND PLANS | | | WILL BE TURNED OVER TO THE FLORIDA BOARD | | | OF PROFESSIONAL ENGINEERS FOR CODE | | | COMPLIANCE REVIEW. | | | | | | | | | PLEASE BE SURE ALL CORRECTIONS ARE MADE, | | | PLEASE CORRELATE ALL PLANS SUBMITTED. | | | PLEASE BE SURE ALL PLANS CORRECTED ARE | | | SIGNED, DATED AND SEALED BY THE | | | RESPECTIVE ARCHITECTS AND ENGINEERS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, IT | | | IS STRONGLY SUGGESTED A PHONE CALL BE | | | MADE TO SET UP A MEETING TO GO OVER ANY | | | QUESTIONS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-20 |
Time |
14:49 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-07-20 |
Time |
14:49 |
Sent To |
P |
|
| Notes |
| 2005-07-20 00:00:00 | ********* UNSAT 3RD REVIEW ************ | | | | | | 1)NOTE: PLEASE SEE NOW A COPY OF | | | "CLUBHOUSE ELECTRICAL PLANS" HAVE NOW | | | BEEN SUBMITTED. | | | PLEASE SEE THESE PLANS DO NOT CORRELATE | | | WITH ELECTRICAL PLANS SUBMITTED FOR | | | POOL. | | | PLEASE SEE CLUBHOUSE PLANS SHOWS A NEW | | | POOL PANEL, HOWEVER THIS DOES NOT | | | CORRELATE WITH ELECTRICLA WIRING DIAGRAM | | | AND POOL PANEL SUBMITTED BYBEA.??? | | | | | | 2)NOTE: PLEASE ALSO SEE ANY NOTES FROM | | | PREVIOUS REVIEWS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION | | | AFTER CORRECTIONS ARE MADE. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected]. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-15 |
Time |
19:37 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-06-15 |
Time |
19:33 |
Sent To |
P |
|
| Notes |
| 2005-06-15 00:00:00 | ********** UNSAT 2ND REVIEW ******** | | | | | | PLEASE SEE NOTES FROM PREVIOUS REVIEW. | | | | | | 1)NOTE: PLEASE SEE PLANS AND PERMIT | | | APPLICATION INCLUDE A HEAT PUMP. THIS IS | | | ALSO SHOWN ON A SUBMITTED 8 1/2 X 11 | | | SUBMITTED AND ATTACHED TO ELECTRICAL | | | SHEET. PLEASE SEE THIS HEAT PUMP,WIRING | | | ETC IS NOT INDICATED ON ELECTRICAL PLANS | | | OR EQUIPMENT SCHEDULE?? | | | PLEASE SEE THIS IS NOT INCLUDED IN LOAD | | | CALCS FOR POOL PANEL OR FEED TO NEW POOL | | | PANEL. | | | | | | 2)NOTE: PLEASE INCLUDE MANUFACTURE | | | CUT/SPEC SHEETS FOR NEW HEAT PUMP | | | SHOWING LISTING FROM A NRTL. | | | | | | 3)NOTE: PLEASE REMOVE ANY AND ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW | | | REVISED SHEETS INTO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-03-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-29 |
Time |
11:53 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-03-29 |
Time |
11:50 |
Sent To |
P |
|
| Notes |
| 2005-03-29 00:00:00 | *********** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SUBMIT A WIRING DIAGRAM | | | FOR HOOK-UP OF ALL NEW ELECTRICAL | | | EQUIPMENT. | | | PLEASE SHOW WHERE NEW EQUIPMENT IS BEING | | | FED FROM. | | | CONDUITS,AWG, OCP ETC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-20 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-20 |
Time |
10:40 |
Sent To |
E |
|
| Notes |
| 2005-09-20 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-31 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-31 |
Time |
15:49 |
Sent To |
E |
|
| Notes |
| 2005-08-31 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-19 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-19 |
Time |
13:41 |
Sent To |
E |
|
| Notes |
| 2005-07-19 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-09 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-09 |
Time |
17:11 |
Sent To |
E |
|
| Notes |
| 2005-06-09 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-28 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-28 |
Time |
14:04 |
Sent To |
E |
|
| Notes |
| 2005-03-28 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-23 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-23 |
Time |
16:03 |
Sent To |
Z |
|
| Notes |
| 2005-03-23 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-14 |
Time |
13:58 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-09-14 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2005-08-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-19 |
Time |
14:31 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2005-08-12 |
Time |
18:32 |
Sent To |
B1 |
|
| Notes |
| 2005-08-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 424 SWIMMING POOLS | | | FBC-2001 CHAPTER 1 | | | | | | A. COMMENTS FROM PREVIOUS REVIEW NOT | | | ADDRESSED: | | | 1) PLANS SHALL BE ROUTED TO THE PALM | | | BEACH COUNTY HEALTH DEPT. FOR REVIEW AND | | | STAMPING PRIOR TO RESUBMITTING FOR | | | REVIEW BY CITY WPB. SECTION 101.4.7. | | | RESPONSE NOTED, BUT MR DUTCH HOLLAND | | | FROM THE PLAM BEACH COUNTY HEALTH DEPT. | | | INDICATES NO POOL PLANS ARE APPROVED | | | UNLESS THEY ARE STAMPED BY THE HEALTH | | | DEPT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-27 |
Time |
18:40 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-06-27 |
Time |
18:40 |
Sent To |
|
|
| Notes |
| 2005-06-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 424 SWIMMING POOLS | | | FBC-2001 CHAPTER 1 | | | | | | A. COMMENTS FROM PREVIOUS REVIEW NOT | | | ADDRESSED: | | | 1) PLANS SHALL BE ROUTED TO THE PALM | | | BEACH COUNTY HEALTH DEPT. FOR REVIEW AND | | | STAMPING PRIOR TO RESUBMITTING FOR | | | REVIEW BY CITY WPB. SECTION 101.4.7. | | | 2) FBC-2001 424.2.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | | SHEETS REQUIRED. (SUBMITTAL) | | | 3) FBC-2001 424.2.14.2 WATER RETENTION, | | | PROVIDE A POSITIVE MEANS OF RETAINING | | | WATER IN THE HEATER WHEN PUMP IS SHUT | | | OFF. (MANUF. CUT SHEETS SUBMITTAL). | | | 4) A SKETCH OF ANY PROPOSED HEATER | | | INSTALLATION INCLUDING VALVES, | | | THERMOMETER, PIPE SIZES, AND MATERIAL | | | SPECIFICATIONS SHALL BE INCLUDED IN THE | | | APPLICATION FOR PERMIT PRIOR TO | | | INSTALLATION. SECTION 424.1.6.5.14 | | | 5) OVERFLOW FROM THE POOL SHALL DRAIN TO | | | STORM, AND WASTE FROM THE FILTER SHALL | | | DRAIN TO SANITARY. (INDICATE ON PLANS). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-12 |
Time |
08:32 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-04-12 |
Time |
08:32 |
Sent To |
B |
|
| Notes |
| 2005-04-12 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 424 SWIMMING POOLS | | | FBC-2001 CHAPTER 1 | | | | | | | | | 1) PLANS SHALL BE ROUTED TO THE PALM | | | BEACH COUNTY HEALTH DEPT. FOR REVIEW AND | | | STAMPING PRIOR TO RESUBMITTING FOR | | | REVIEW BY CITY WPB. SECTION 101.4.7. | | | 2) FBC-2001 424.2.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | | SHEETS REQUIRED. (SUBMITTAL) | | | 3) FBC-2001 424.2.14.2 WATER RETENTION, | | | PROVIDE A POSITIVE MEANS OF RETAINING | | | WATER IN THE HEATER WHEN PUMP IS SHUT | | | OFF. (MANUF. CUT SHEETS SUBMITTAL). | | | 4) A SKETCH OF ANY PROPOSED HEATER | | | INSTALLATION INCLUDING VALVES, | | | THERMOMETER, PIPE SIZES, AND MATERIAL | | | SPECIFICATIONS SHALL BE INCLUDED IN THE | | | APPLICATION FOR PERMIT PRIOR TO | | | INSTALLATION. SECTION 424.1.6.5.14 | | | 5) OVERFLOW FROM THE POOL SHALL DRAIN TO | | | STORM, AND WASTE FROM THE FILTER SHALL | | | DRAIN TO SANITARY. (INDICATE ON PLANS). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-25 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-25 |
Time |
16:22 |
Sent To |
I |
|
| Notes |
|
|