| Plan Review Stops For Permit 05031272 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-05-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-05-25 |
Time |
07:48 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2005-05-25 |
Time |
07:48 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-25 |
Time |
17:46 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-04-25 |
Time |
17:46 |
Sent To |
PC |
|
| Notes |
| 2005-04-25 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | | | 1- NEED ENERGY CALCULATIONS. | | | | | | 2- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | 3- IMPACT FEES. NEED DRAWINGS TO BE | | | STAMPED BY PALM BEACH COUNTY. | | | | | | 4- KEYED DETAILS ON ROOF FRAMING PLANS | | | DON'T MATCH DETAILS ON SHEET A6.DETAIL | | | G/6 AND C1-C2/6 DON'T MATCH. REVISE AS | | | REQUIRED. | | | | | | 5- OWES $1840.76 BALANCE OF PERMIT FEES | | | AND UPDATED VALUATION AND RADON FEES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-05-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-02 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-02 |
Time |
18:51 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-22 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-22 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | CONDUITS ONLY FOR FUTURE GEN. | | | LOCATION FOR CONDUITS NOT REVIEWED FOR | | | CODE COMPLIANCE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-22 |
Time |
09:38 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-11-22 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2005-11-22 00:00:00 | REDLINED, | | | | | | | | | SD IN MASTER BEDRM PER NFPA-72 11.8.3 | | | | | | 20A OCP SHOWN ON #14 AWG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-03 |
Time |
17:44 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-05-03 |
Time |
17:44 |
Sent To |
P |
|
| Notes |
| 2005-05-03 00:00:00 | ********** PROVISO/REVISION ********** | | | | | | PLEASE SEE NOTE'S #2 AND #5 FROM | | | PREVIOUS REVIEW. | | | | | | 1)NOTE: NOTE #2 , PLEASE SEE ORIGINAL | | | PLANS RISER SHOWED 2-#6'S, 1-#8 AND | | | 1-#10 FOR POOL SUB PANEL AND PANEL | | | SCHEDULE "B" SHOWED 3-#6'S? | | | PLEASE SEE NOW AN ADDITIONAL PHASE/HOT | | | CONDUCTOR HAS BEEN ADDED TO FEED | | | PANEL"C". PLEASE SEE RISER NOW SHOWS | | | 3-HOTS, 1-NEUTRAL AND 1-EQUIP GRND.??? | | | | | | PLEASE ADJUST TO ACTUAL INSTALLATION. | | | | | | 2)NOTE: NOTE #5, ORIG PLANS SHOWWS 4.5KW | | | FOR COND UNITS, WITH 40A OCP AND #10 | | | AWG. PLEASE SEE 4.5KW @240= 18.75A'S. | | | IT WAS REQUESTED TO VERIFY OCP FOR LOAD | | | AND AWG SHOWN, HOWEVER, 3-#6'S WERE | | | ADDED TO PANEL SCHEDULES INSTEAD.??? | | | | | | PLEASE ADJUST TO ACTUAL INSTALLATION. | | | | | | | | | | | | ***PLEASE MAKE THE ABOVE CORRECTIONS AND | | | SUBMIT WITH ANY OTHER POSSIBLE REVISIONS | | | BEFORE ROUGH ELECTRICAL INSPECTION IS | | | CALLED IN. | | | | | | IF THERE ARE ANY QUESTIONS, ONCE AGAIN, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-03-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-28 |
Time |
16:39 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-03-28 |
Time |
16:39 |
Sent To |
M |
|
| Notes |
| 2005-03-28 00:00:00 | *** UNSAT *** | | | | | | 1)NOTE: PLEASE CORRELATE RISER WITH | | | PLANS. PLANS INDICATE TWO POOL PANELS? | | | ONE AT SERVICE LOCATION AND ONE AT POOL | | | EQUIPMENT LOCATION. (MISPRINT). | | | | | | 2)NOTE: PLEASE CORRELATE WIRING FOR | | | SUB-PANEL "C", SHOWS 3-#6'S ON PANEL | | | SCHEDULE"B" , YET RISER SHOWS 2-#6'S AND | | | #8? | | | | | | 3)NOTE: PLEASE SEE MISSING RECETP PER | | | 210.52 IN BEDRM #3. | | | | | | 4)NOTE: PLEASE SEE COOKTOP SHOWS 6KW | | | LOAD ON 1-POLE 20A BRKR. | | | 215.5,310.16,240.4 TEC. | | | | | | 5)NOTE: PLEASE VERIFY LOAD/OCP AND AWG | | | FOR BOTH A/C CU'S. | | | 4.5KW ON 40A OCP AND #10 AWG. | | | 240.4,310.16 | | | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-05-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-01 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-01 |
Time |
08:45 |
Sent To |
E |
|
| Notes |
| 2006-05-01 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-18 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-18 |
Time |
14:06 |
Sent To |
E |
|
| Notes |
| 2005-11-18 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-29 |
Time |
18:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-29 |
Time |
18:40 |
Sent To |
P |
|
| Notes |
| 2005-09-29 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-03 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-03 |
Time |
14:06 |
Sent To |
E |
|
| Notes |
| 2005-05-03 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-28 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-28 |
Time |
14:11 |
Sent To |
E |
|
| Notes |
| 2005-03-28 00:00:00 | TO "SFR""E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-25 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2005-03-23 |
Time |
15:19 |
Sent To |
PC |
|
| Notes |
| 2005-03-23 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-05-19 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-05-19 |
Time |
11:49 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-05-19 |
Time |
11:49 |
Sent To |
B |
|
| Notes |
| 2005-05-19 00:00:00 | MECH. RESUB: | | | | | | A/C PLANS AND EQUIP. INFO. OK. | | | ENERGY CALK,SOK. | | | | | | PR 5/19/05. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-04 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-04-04 |
Time |
07:46 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-04-04 |
Time |
07:46 |
Sent To |
P |
|
| Notes |
| 2005-04-04 00:00:00 | MMECH. PLAN REVIEW. | | | | | | 1. NO A/C PLANS OR EQUIPMENT | | | INFORMATION. | | | 2. NO ENERGY CALCULATION FOR BUILDING. | | | | | | PAT RAFTER 805/6728 OR 805/6719 PATTY | | | KRAUSS. | | | PLEASE CALL IF THEAR ANY QUISTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-05-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-05-14 |
Time |
12:45 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-05-14 |
Time |
12:45 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-04-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-04-06 |
Time |
17:58 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-04-06 |
Time |
17:58 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-25 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-25 |
Time |
15:25 |
Sent To |
I |
|
| Notes |
| 2005-03-25 00:00:00 | NOTE: 2ND REF MUST BE A U/C REF. | | | MUST PULL SEPERATE PERMIT FOR | | | POOL/DECK/SPA/SCREEN ENCLOSURE. |
|
|