| Plan Review Stops For Permit 05031189 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-12-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-12-02 |
Time |
18:27 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2005-12-02 |
Time |
18:24 |
Sent To |
PC |
|
| Notes |
| 2005-12-02 00:00:00 | BUILDING REVIEW PROVISO: | | | 1- PROVIDE COMPLETE PRODUCT APPROVAL | | | INFORMATION AS REQUIRED BY RULE 9B-72 | | | FOR 9'X5' FIXED IMPACT WINDOW IN LIVING | | | ROOM UNDER A SEPARATE PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-10-06 |
Time |
14:31 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2005-10-06 |
Time |
14:31 |
Sent To |
PC |
|
| Notes |
| 2005-10-06 00:00:00 | PRODUCT APPROVAL CHECKLIST: | | | 1- ENGINEER TO USE CURRENT PRODUCT | | | APPROVAL FORM ONLY. | | | | | | 2- DRAWINGS DON'T MATCH EYEBROW WINDOW | | | SHOWN ON ARCHITECTURAL PLANS. | | | | | | 3- THERE ARE 2 DIFFERENT TYPES OF | | | SILICONE SPECIFIED ON DRAWINGS AND ON | | | PRODUCT APPROVAL FORMS. | | | | | | 4- NEED FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR ARCH 4500 WINDOW FRAME. | | | | | | 5- NEED A COMPLETE ENGINEERING ANALYSIS, | | | DETAILS AND SPECS FOR THE PROPOSED | | | INSTALLATION. ENGINEER TO BE EXPERIENCED | | | IN THIS TYPE OF WORK AS REQUIRED BY SEC. | | | 2406.2 FBC 2001. SEE ATTACHED COPY. | | | | | | 6- PRODUCT APPROVAL FORM MUST BE | | | COMPLETE. INCLUDING ITEM #1. | | | | | | 7- REVISE ARCHITECTURAL PLANS TO MATCH | | | PROPOSED WINDOW. | | | | | | 8- ENGINEER TO CONTACT ROBERT BROWN WHO | | | IS THE LICENSE/PERMIT SERVICES MANAGER | | | IN CHARGE OF THE LOCAL PRODUCT APPROVAL | | | ASK HIM FOR SPECIFIC PROCEDURE AND | | | INFORMATION TO BE SUBMITTED FOR LOCAL | | | PRODUCT APPROVAL. (561)805-6652. | | | | | | ***NOTE: THESE COMMENTS APPLY TO PERMIT | | | #05031187 AND 05031189. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-12-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-09-30 |
Time |
17:28 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-09-30 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2005-09-30 00:00:00 | CALLED CONTRACTOR TO GET PRODUCT | | | APPROVAL FOR EYEBROW WINDOW AND REVISE | | | NOC. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-08-10 |
Time |
15:22 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2005-08-10 |
Time |
15:20 |
Sent To |
PC |
|
| Notes |
| 2005-08-10 00:00:00 | BUILDING REVIEW THIRD CHECKLIST: | | | 1- ENERGY CALCULATIONS ARE STILL WRONG. | | | (SEE COPY OF FLORIDA STATUTE | | | 553.80(2)(B)REGARDING DESIGN | | | PROFESSIONAL DOCUMENTS).OVERHANG LENGTH | | | AND HEIGHT ARE STILL WRONG. SEE SEC. | | | 601.2 OF CHAPTER 13 FBC. | | | **NOTE: ARCHITECT ALSO NEEDS TO IMPRESS | | | HIS SEAL IN ALL DOCUMENTS THAT ARE | | | SUBMITTTED FOR PUBLIC RECORDS AS REQ'D | | | BY CHAPTER 481 FLORIDA STATUTES. | | | | | | 2- PROVIDE FLORIDA OR APPLY FOR LOCAL | | | PRODUCT APPROVAL FOR: | | | A) POCKET SLIDING GLASS DOORS AS SHOWN | | | ON PLANS. | | | | | | B) BAY WINDOW FOR BREAKFAST AREA. | | | PRODUCT APPROVAL SUBMITTED DOESN'T COVER | | | SIZE SPECIFIED ON PLANS FOR BREAKFAST | | | AREA. | | | | | | C) EYEBROW WINDOW ASSEMBLY AS SHOWN ON | | | LIVING ROOM. | | | | | | D) CASEMENT WINDOWS. NEED DADE COUNTY | | | NOA REPORT THAT MATCHES ONE SUBMITTED | | | FOR FLORIDA PRODUCT APPROVAL. | | | | | | E) ALL TRUSS CONNECTORS SPECIFIED ON | | | PLANS. | | | | | | 3- SIZE OF LIVING ROOM WINDOW SPECIFIED | | | ON SHEET A1 DOESN'T MATCH SIZE SHOWN ON | | | THE REAR ELEVATION. REVISE/CLARIFYAS | | | REQUIRED TO VERIFY PRODUCT APPROVAL | | | COMPLIANCE. | | | | | | 4- SHEET A1: A) NOTE ON GARAGE ATTIC | | | STORAGE IS WRONG. IT SHOULD BE 30PSF | | | ATTIC LIVE LOAD NOT 30PSF DEAD LOAD. | | | REVISE AS REQ'D. TABLE 1604.1 FBC 2001. | | | | | | B) WINDOW GLAZING NOTE: REFERENCED SEC. | | | #3513 DOESN'T APPLY. REVISE AS REQUIRED. | | | | | | 5- SLIDING GLASS DOOR POCKET DETAIL. | | | PREVIOUS CHECKLIST REQUIRED TO SPECIFY | | | 7/8" MIN. STUCCO THICKNESS AS REQUIRED | | | BY ASTM C-926. DETAIL WAS REVISED TO | | | HAVE 7/8" CDX PLYWOOD INSTEAD. REVISE AS | | | REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-06-27 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
prafter |
Date |
2005-07-08 |
Time |
08:40 |
Sent To |
E |
|
| Notes |
| 2005-06-27 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | 2- SHEET A3: ROOF LOADS CHART WAS NOT | | | REVISED. NEED TO SHOW THE 30PSF ATTIC | | | LIVE LOAD AT GARAGE STORAGE AREA AND THE | | | 10PSF ATTIC LIVE LOAD AT NON STORAGE | | | AREAS AS REQ'D BY TABLE 1604.1 FBC 2001. | | | | | | 3- REAR ELEVATION STILL SHOWS BUTT | | | GLAZING SYSTEM AT BREAKFAST AREA, MASTER | | | BEDROOM AND LIVING ROOM. FLOOR PLAN | | | CALLS FOR FIXED WINDOW. REVISE AS | | | REQUIRED. | | | | | | 4- SHEET A1: A) NOTE ON GARAGE ATTIC | | | STORAGE IS WRONG. IT SHOULD BE 30PSF | | | ATTIC LIVE LOAD NOT 30PSF DEAD LOAD. | | | REVISE AS REQUIRED. 1604.1 FBC 2001. | | | | | | B) WINDOW GLAZING NOTE: WHERE IS SECTION | | | #3513 TAKEN FROM?. IT DOESN'T APPLY. | | | REVISE AS REQUIRED. | | | | | | 5- SHEET A7: A) WOOD BEARING WALL DETAIL | | | NEEDS MORE INFORMATION. SPECIFY | | | HURRICANE CLIPS FOR TOP & BOTTOM STUDS. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | | | B) SLIDING GLASS DOOR POCKET DETAIL | | | NEEDS TO BE SPECIFIC WITH TYPE OF | | | HURRICANE CLIPS TO BE USED AT BOTTOM AND | | | TOP OF FRAMED WALL. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | **ALSO, SPECIFY 7/8" MIN. STUCCO | | | THICKNESS AT FRAMED WALL AS REQUIRED BY | | | ASTM C-926. | | | | | | 6- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) 10'-0" HIGH ENTRY DOORS. | | | B) POCKET SLIDING GLASS DOORS. SEE PLAN. | | | C) WINDOW MULLIONS AND CLEARLY MARK SIZE | | | & ANCHORS TO BE USED TO VERIFY DESIGN | | | PRESSURES CAPACITY. | | | D) CASEMENT WINDOWS. SEE PLANS. | | | E) ALL TRUSS CONNECTORS SPECIFIED ON | | | PLANS. | | | F) MASTER BEDROOM, BREAKFAST AREA AND | | | LIVING ROOM WINDOW ASSEMBLIES AS SHOWN | | | ON PLANS. | | | G) FIXED WINDOWS WITH SIZES A SHOWN ON | | | FAMILY ROOM REAR FIXED WIND, ABOVE | | | SLIDING GLASS DOOR AND BREAKFAST AREA. | | | PRODUCT APPROVAL SUBMITTED DOESN'T COVER | | | THOSE SIZES. | | | | | | 7- WALL SECTION A/2 IS MISSING SPECS FOR | | | CONNECTORS AT BOTTOM OF WOOD FRAMED | | | WALL. SEC. 104.2.1.2 CITY ADMENDMENT TO | | | FBC 2001. | | | | | | 8- OWES $4247.67 FOR PERMIT FEES AND | | | RADON FEES. | | | | | | 9- ENERGY CALCULATIONS: | | | A) OVERHANG LENGTH AND HEIGHT ARE STILL | | | WRONG. SEE PLANS AND CHAPTER 13 FBC 2001 | | | FOR PROPER WAY TO CALCULATE THEM. | | | | | | B) ENERGY CALCS PREPARER TO SIGN AND | | | DATE FORM. | | | | | | C) OWNER/AGENT TO SIGN AND DATE FORM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-22 |
Time |
17:05 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2005-04-22 |
Time |
17:05 |
Sent To |
PC |
|
| Notes |
| 2005-04-22 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- PAY IMPACT FEES. BRING BACK STAMPED | | | DRAWINGS AND PAID RECEIPT. | | | | | | 2- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | 3- SHEET A1: A) ATTIC ABOVE GARAGE USED | | | FOR STORAGE NEEDS TO BE DESIGNED FOR | | | 30PSF LIVE LOAD AT BOTTOM CHORD OF | | | TRUSS. ALSO, CLEARLY IDENTIFY AREAS | | | DESIGNED FOR STORAGE. SPECIFY 10PSF OR | | | 30PSF ATTIC LIVE LOAD AS REQUIRED BY | | | TABLE 1604.1 FBC 2001. | | | | | | B) SPECIFY SAFETY GLASS AT FAMILY ROOM | | | AND MASTER BEDROOM WINDOWS AS REQUIRED | | | BY SEC. 2405.2.1(3) FBC 2001. | | | | | | C) SPECIFY SIZE OF ATTIC ACCESS IN | | | MASTER BEDROOM CLOSET. SEC. 2309.6 FBC. | | | | | | D) REVISE BEAM ELEVATION AT ENTRY DOORS. | | | SEE SIZE OF DOOR. | | | | | | E) SHOW ON PLAN PRIVACY WALL SHOWN ON | | | FOUNDATION PLAN. | | | | | | 4- SHEET A2: A) PROVIDE FOOTINGS AND | | | SPECS FOR PORTICO COLUMNS AND COLUMNS IN | | | FRONT OF GARAGE. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | B) SPECIFY WHY FOOTINGS FOR CONCRETE | | | PIERS AT LOW PRIVACY WALL ARE BIGGER | | | THAN FOOTINGS FOR INTERIOR BEARING | | | COLUMN AND REAR PORCH COLUMN. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 5- SHEET A3: A) CLEARLY INDICATE ON ROOF | | | FRAMING PLAN ANCHORS TO BE USED. SPECIFY | | | ANCHOR AT ALL CONNECTIONS. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | B) CONNECTOR SPECIFIED AT FRONT OF | | | PORTICO IS FOR MASONRY APPLICATION. | | | NEEDS WOOD TO WOOD CONNECTOR. SEE PLANS | | | AND REVISE AS REQUIRED. | | | | | | C) REVISE ROOF LOADS CHART. NEED TO | | | SPECIFY 30PSF AND 10PSF ATTIC LIVE LOADS | | | IN ATTIC. TABLE 1604.1 FBC 2001. | | | | | | 6- ELEVATIONS ON SHEET A6 DON'T MATCH | | | FLOOR PLAN. RIGHT SIDE ELEVATIONS DON'T | | | SHOW POCKET SLIDING GLASS DOORS AND | | | GLASS BLOCK AS SHOWN ON PLANS. REAR | | | ELEVATION DON'T SHOW SAME TYPE AND | | | NUMBER OF WINDOW PANELS AS SHOWN ON | | | PLANS. CLARIFY IF USING BUTT GLAZING OR | | | BAY WINDOW ASSEMBLY. | | | | | | 7- SHEET A7; REVISE CONNECTOR SPECIFIED | | | ON WOOD BEARING WALL DETAIL. SEMCO IS | | | OUT OF BUSINESS. | | | | | | 8- PROVIDE FRAMING DETAILS AND SPECS FOR | | | POCKET WALL FOR SLIDING GLASS DOOR. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 9- PROVIDE BBQ LISTING AND SPECS. NEED | | | MANUFACTURER'S SPECS STATING THAT BBQ IS | | | DESIGNED TO BE INSTALLED IN PORCH. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 10- CLEARLY SPECIFY IF USING IMPACT | | | GLAZING OR STORM SHUTTERS AND PROVIDE | | | COMPLETE INFORMATION FOR EITHER METHOD | | | OF GLASS PROTECTION. | | | | | | 11- PROVIDE COMPLETE FLORIDA OR LOCAL | | | PRODUCT APPROVAL FOR: A) 10'-0" ENTRY | | | DOORS. | | | | | | B) 18'-0" WIDE GARAGE DOOR. | | | | | | C) POCKET SLIDING GLASS DOORS. SEE PLANS | | | | | | D) WINDOW MULLIONS. | | | | | | E) CASEMENT WINDOWS. | | | | | | F) ALL TRUSS CONNECTORS SPECIFIED ON | | | PLANS. | | | | | | G) HORIZONTAL SLIDER WINDOWS. | | | | | | H) BUTT GLAZING SYSTEM OR WINDOW | | | ASSEMBLY AS SHOWN ON PLANS AT MASTER | | | BEDROOM, LIVING ROOM AND BREAKFAST AREA. | | | | | | I) FRENCH DOORS AS SHOWN ON PLANS. | | | | | | 12- PROVIDE FRAMING DETAILS & SPECS FOR | | | WALL ABOVE BREAKFAST WINDOW. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 13- OWES $4247.67 FOR FERMIT FEES AND | | | RADON FEES. | | | | | | 14- ENERGY CALCULATIONS: A) NEED WORST | | | CASE SCENARIO CALCULATIONS OR CALCS | | | SHALL BE DONE WITH BUILDING CORRECT | | | ORIENTATION. | | | | | | B) OVERHANG LENGHT AND HEIGHT ARE | | | INCORRECT. SEE CHAPTER 13 FBC 2001 FOR | | | PROPER WAY OF CALCULATING THESE | | | DIMENSIONS AND REVISE AS REQUIRED. | | | | | | C) OWNER/AGENTTO SIGN AND DATE FORM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-23 |
Time |
15:35 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-10-23 |
Time |
13:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2006-10-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-19 |
Time |
07:27 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-10-19 |
Time |
07:26 |
Sent To |
PC |
|
| Notes |
| 2006-10-19 07:27:49 | | | | | | | REVISION DENIED | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} THE RISER DIAGRAM INDICATES PANEL "P" BEING FED FROM | | | PANEL "A". THE PANEL SCHEDULE INDICATES PANEL "P" FED | | | FROM PANEL "B", PLEASE CORRELATE. | | | | | | 2} THE FEED TO PANEL "P" MUST CONTAIN AN EQUIPMENT | | | GROUND PER 250.122, #10CU. | | | | | | 3} THE QUALITY OF THE REVISION SUBMITTED IS | | | INSUFFICIENT FOR RECORD RETANTION PER 106.1.3 FBC AS | | | AMENDED. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-16 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-16 |
Time |
07:30 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-05-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-09 |
Time |
20:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-09 |
Time |
20:28 |
Sent To |
PC |
|
| Notes |
| 2006-05-09 00:00:00 | ********** UNSAT ************* | | | | | | | | | 1) NOTE: PLEASE SEE PLANS CONTAIN | | | "WHITE-OUT" WHICH IS NOT PERMITTED. | | | PLEASE REPRINT AND SIGN, SEAL AND DATE | | | CHANGES. | | | FS 481.221. | | | ** SOME HAND DRWN CHNAGES ARE PERMITTED | | | TO PLANS SIGNED AND SEAL BY A DESIGN | | | PROFESSIONAL, HOWEVER EACH AND EVERY | | | CHNAGE MUST BE SIGNED AND DATED. | | | PLEASE KNOW, IN NO CASE CAN PLANS | | | CONATIN "WHITE-OUT". | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-04-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-21 |
Time |
17:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-04-14 |
Time |
16:57 |
Sent To |
PC |
|
| Notes |
| 2006-04-14 00:00:00 | CALLED CONT FOR REV'S AND CORRECTIONS | | | BEFORE REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-04-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-04 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-04 |
Time |
16:54 |
Sent To |
PC |
|
| Notes |
| 2006-04-04 00:00:00 | REV'S FOR BT OUT OF OFFICE. | | | | | | REDLINED SD LOCATION IN MASTER BEDRM TO | | | BE WITHIN 12" OF THE HIGHEST POINT ON A | | | FLAT CEILING. NFPA-72 11.8..3.5 | | | | | | METER/ PANELS ARE BACK TO BACK, VIF. | | | | | | | | | CIRCUIT FOR UTIL/HALL LTS, SHOWS 15A OCP | | | ON #12, WHICH IS OK. | | | PLANS REDLINED, | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-29 |
Time |
11:20 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-29 |
Time |
07:27 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-03-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-29 |
Time |
08:35 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-03-29 |
Time |
08:34 |
Sent To |
M |
|
| Notes |
| 2005-03-29 00:00:00 | REDLINED LOAD SHOWN ON GFI CIRCUIT, | | | 2.2KW ON 1P20 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-10-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-10 |
Time |
19:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-10 |
Time |
19:40 |
Sent To |
E |
|
| Notes |
| 2006-10-10 19:40:59 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-15 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-15 |
Time |
15:03 |
Sent To |
E |
|
| Notes |
| 2006-05-15 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-05-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-06 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-06 |
Time |
15:59 |
Sent To |
E |
|
| Notes |
| 2006-05-06 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-12 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-12 |
Time |
16:29 |
Sent To |
E |
|
| Notes |
| 2006-04-12 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-03 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-03 |
Time |
09:07 |
Sent To |
E |
|
| Notes |
| 2006-04-03 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-31 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-31 |
Time |
16:36 |
Sent To |
M |
|
| Notes |
| 2006-03-31 00:00:00 | TO "M" BOX/ REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-16 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-16 |
Time |
13:16 |
Sent To |
B |
|
| Notes |
| 2005-11-16 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-20 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-20 |
Time |
12:10 |
Sent To |
P |
|
| Notes |
| 2005-09-20 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-21 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-21 |
Time |
16:19 |
Sent To |
B |
|
| Notes |
| 2005-07-21 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-07 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-07 |
Time |
16:29 |
Sent To |
B |
|
| Notes |
| 2005-06-07 00:00:00 | TO JG DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-28 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-28 |
Time |
14:27 |
Sent To |
E |
|
| Notes |
| 2005-03-28 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-04-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-22 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2005-03-22 |
Time |
08:00 |
Sent To |
Z |
|
| Notes |
| 2005-03-22 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-03 |
Time |
12:14 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-04-03 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2006-04-03 00:00:00 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-07-08 |
Time |
08:53 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-07-08 |
Time |
08:53 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-04-04 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-04-04 |
Time |
08:30 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-07-08 |
Time |
08:42 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-07-08 |
Time |
08:43 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-07-06 |
Time |
19:18 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-04-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-04-06 |
Time |
17:47 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-04-06 |
Time |
17:47 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-22 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-24 |
Time |
11:14 |
Sent To |
I |
|
| Notes |
| 2005-03-24 00:00:00 | NOTE: MUST PULL SEPERATE PERMIT FOR | | | POOL/DECK/SCREEN ENCLOSURE. |
|
|