Plan Review Details - Permit 05031187
Plan Review Stops For Permit 05031187
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-12-05 Cont ID  
Sent By jgomez Date 2005-12-02 Time 12:13 Rev Time 2.50
Received By jgomez Date 2005-12-02 Time 12:13 Sent To PC
Notes
2005-12-05 00:00:00BUILDING REVIEW PROVISO:
  
 1- AS AGREED WITH CONTRACTOR. PROVIDE
 COMPLETE PRODUCT APPROVAL INFORMATION AS
 REQUIRED BY RULE 9B-72 FOR 9'X5' FIXED
 IMPACT WINDOW IN LIVING ROOM UNDER A
 SEPARATE PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2005-10-06 Cont ID  
Sent By jgomez Date 2005-10-06 Time 14:51 Rev Time 1.00
Received By jgomez Date 2005-10-06 Time 14:50 Sent To PC
Notes
2005-10-06 00:00:00BUILDING REVIEW CHECKLIST:
 1- COMMENTS FOR PERMIT NUMBER 05031189
 REGARDING THE WINDOW PRODUCT APPROVAL
 ARE THE SAME. SEE ATTACHED COPY
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-12-02 Cont ID  
Sent By jgomez Date 2005-09-30 Time 16:03 Rev Time 2.00
Received By jgomez Date 2005-09-30 Time 16:03 Sent To  
Notes
2005-09-30 00:00:00WAITING FOR CONTRACTOR TO BRING PRODUCT
 APPROVAL FOR EYEBROW WINDOW. AND REVISED
 NOC WITH EXACT ADDRESS. NOT LOTS 84 AND
 85.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-07-27 Cont ID  
Sent By jgomez Date 2005-07-27 Time 08:34 Rev Time 2.50
Received By jgomez Date 2005-07-26 Time 16:27 Sent To E
Notes
2005-07-26 00:00:00BUILDING REVIEW CHECKLIST:
  
 1- NEED RE-RECORDED NOTICE OF
 COMMENCEMENT. IT EXPIRES AFTER 90 DAYS
 IF WORK IS NOT STARTED.
  
 2- SHEET A3:A) ROOF LOADS CHARTWAS
 NOT REVISED. IT DOESN'T INCLUDE THE
 30PSF ATTIC LIVE LOAD FOR AREAS WITH
 STORAGE AND THE 10PSF ATTIC LIVE LOAD
 FOR NON-STORAGE AREAS. SOME NOTES
 PERTAINING TO THIS LOADS WERE ADDED ON
 SAME PAGE, BUT, THEY DON'T MATCH ROOF
 LOAD CHART.
  
 B) REVISE NOTE ABOVE BREAKFAST AREA.
 WINDOW USED IS NOT BUTT GLAZING.
  
 C) ROOF TILE ANCHORAGE IS BASED ON THE
 UPLIFT MOMENT. PROVIDE MOMENT CALCS TO
 VERIFY THAT ONLY ONE SCREW WILL RESIST
 THE UPLIFT MOMENT. SEC. 104.2.1.1AND
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 (ACCORDING TO THE FRSA MOMENT UPLIFT
 CHART ONE SCREW IS NOT ENOUGH).
  
 3- SHEET A1: REVISE NOTE ABOVE GARAGE
 AREA. IT IS ATTIC LIVE LOAD, NOT ATTIC
 DEAD LOAD OF 30PSF FOR STORAGE.
 SEE TABLE 1604.1 FBC 2001.
  
 4- SHEET A2: THERE IS NOT FOOTING SHOWN
 FOR CONCRETE COLUMN IN COVERED PORCH BY
 THE FAMILY ROOM AREA.
  
 5- REAR ELEVATION ON SHEET A6 SHOWS
 WINDOS AT MASTER BEDROOM, LIVING ROOM
 AND BREAKFAST AREA AS BUTT GLAZING
 SYSTEM. REVISE TO MATCH FLOOR PLAN.
  
 6- CLEARLY SPECIFY WINDOW MULLIONS TYPE,
 SIZE AND ANCHORS TO BE USED ON
 ASSEMBLIES AT MASTER BEDROOM,LIVING ROOM
 AND BREAKFAST AREA. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001. AND PROVIDE
 PERTAINING FLORIDA OR LOCAL PRODUCT
 APPROVAL.
  
 7- SHEET A7 BEARING WALL DETAIL: PROVIDE
 SPECIFIC TYPE OF HURRICANE CLIPS. SEC.
 104.2.1 FBC 2001.
  
 8- PROVIDE FLORIDA PRODUCT APPROVAL OR
 APPLY FOR LOCAL PRODUCT APPROVAL FOR:
 A) ENTRY DOORS (DADE COUNTY NOA ALONE IS
 NOT AUTOMATICALLY A FL. PROD. APPROVAL).
 B) POCKET SLIDING GLASS DOORS (DADE
 COUNTY NOA ALONE IS NOT A FLORIDA
 PRODUCT APPROVAL).
 C) WINDOW MULLIONS AS SHOWN ON PLANS.
 D) ALL TRUSS ANCHORS SPECIFIED ON PLANS.
 E) CASEMENT WINDOWS.
 F) BAY WINDOWS SHOWN ON MASTER BEDROOM,
 LIVING AND BREAKFAST AREA.
  
 9- OWES $4247.67. PERMIT FEES NOT PAID.
  
 10- ENERGY CALCULATIONS: A) WHEN
 PREPARED BY ARCHITECT MUST BE SIGNED,
 SEALED AND DATED AS REQ'D BY CHAPTER 481
 FL STATUTE
  
 B) OVERHANG LENGTH AND HEIGHT ARE NOT
 DONE CORRECTLY. SEE SEC. 601.2.A.3 OF
 CHAPTER 13 FBC 2001 FOR PROPER WAY OF
 CALCULATING THESE DIMENSIONS.
  
 *REMAINDER: OWNER/AGENT TO SIGN AND DATE
 FORM AS WELL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-04-22 Cont ID  
Sent By jgomez Date 2005-04-22 Time 14:21 Rev Time 2.50
Received By jgomez Date 2005-04-22 Time 14:21 Sent To PC
Notes
2005-04-22 00:00:00BUILDING REVIEW CHECKLIST:
 1- PAY IMPACT FEES. BRING BACK STAMPED
 DRAWINGS AND PAID RECEIPT.
  
 2- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 3- SHEET A1: A) ATTIC ABOVE GARAGE USED
 FOR STORAGE NEEDS TO BE DESIGNED FOR
 30PSF LIVE LOAD AT BOTTOM CHORD OF
 TRUSS. REMAINDER OF ATTIC IF IS NOT USED
 FOR STORAGE NEEDS TO BE DESIGNED FOR
 10PSF AS REQUIRED BY TABLE 1604.1 FBC
 2001. REVISE NOTE ON GARAGE AREA AND
 CLEARLY INDICATE STORAGE OR NON STORAGE
 AREAS. SEE PLANS FOR COMMENTS.
  
 B) SPECIFY SAFETY GLASS AT FAMILY ROOM
 AND MASTER BEDROOM WINDOWS AS REQUIRED
 BY SEC. 2405.2.1(3) FBC 2001. SEE PLANS.
  
 C) SPECIFY SIZE OF ATTIC ACCESS IN
 MASTER BEDROOM CLOSET. SEC. 2309.6 FBC.
  
 D) REVISE ELEVATIONS FOR BEAMS AT ENTRY
 DOORS. SIZE OF DOOR IS TALLER THAN
 HEIGHT SPECIFIED FOR BEAM HEIGHT.
  
 E) SHOW ON PLAN PRIVACY WALL IN FRONT OF
 BATHROOM AS SHOWN ON FOUNDATION PLAN.
  
 4- SHEET A2: A)THERE ARE NOT FOOTINGS
 FOR PORTICO COLUMNS AND COLUMNS IN FRONT
 OF GARAGE. PROVIDE DETAILS SPECS AS
 REQ'D. SEC. 104.2.1.2 CITY AMENDMENTS TO
 FBC 2001.
  
 B) CLARIFY WHY FOOTINGS FOR CONCRETE
 BLOCK PIERS AT FRONT PRIVACY WALLARE
 BIGGER THAN THE FOOTINGS SPECIFIED FOR
 REAR PORCH AND INTERIOR STEEL COLUMN.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
  
 5- SHEET A3: A) CLEARLY INDICATE ON ROOF
 FRAMING PLAN ANCHORS TO BE USED. SPECIFY
 ANCHORS AT ALL CONNECTIONS IN ROOF
 FRAMING PLAN. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 B) CONNECTOR SPECIFIED AT FRONT OF
 PORTICO IS FOR MASONRY APPLICATION.
 NEEDS WOOD TO WOOD CONNECTOR. REVISE AS
 REQ'D.
  
 C) REVISE ROOF LOADS CHART. NEED TO
 SPECIFY 30PSF AND 10PSF ATTIC LIVE LOAD
 IN THE ATTIC (BCLL) AS REQUIRED BY TABLE
 1604.1 FBC 2001.
  
 6- ELEVATIONS ON SHEET A6 DON'T MATCH
 FLOOR PLAN. RIGHT SIDE ELEVATION NEED TO
 SHOW POCKET FOR SLIDING GLASS DOORS AND
 MASTER BATHROOM GLASS BLOCK. REAR
 ELEVATION DON'T SHOW SAME TYPE AND
 NUMBER OF WINDOWS AS SPECIFIED ON PLANS.
  
  
 7- SHEET A7: REVISE CONNECTORS SPECIFIED
 ON WOOD BEARING WALL DETAIL. SEMCO IS
 OUT OF BUSINESS.
  
 8- PROVIDE FRAMING DETAILS AND SPECS FOR
 POCKET WALL AT SLIDING GLASS DOORS IN
 FAMILY ROOM. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 9- BBQ SPECS TYPICALLY SAY THAT THEY ARE
 DESIGNED FOR OUTDOORS ONLY. PROVIDE BBQ
 LISTING AND MANUFACTURER SPECS STATING
 THAT BBQ WILL BE OK TO INSTALL IN THE
 PORCH.SECTION 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 10- CLEARLY SPECIFY IF USING WINDOWS AND
 DOORS WITH IMPACT GLAZING OR SHUTTERS.
 BOTH PRODUCT APPROVALS WERE SUBMITTED
 AND IS NOT CLEAR WICH GLASS PROTECTION
 METHOD IS GOING TO BE INSTALLED.
  
 11- IF USING STORM SHUTTERS, THEN
 PROVIDE KEY PLAN AND COMPLETE
 INSTALLATION SCHEDULE. SEE SAMPLE. SEE
 SHUTTERS INSTALLATION SCHEDULE IN
 DRAWINGS AND MARK SPECIFIC ANCHOR AND
 SPACING TO BE USED.
  
 12- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR: A) 10'-0" H. ENTRY DOORS.
  
 B) 18'-0" WIDE GARAGE DOOR.
  
 C) POCKET SLIDING GLASS DOORS. SEE PLANS
  
 D) WINDOW MULLIONS.
  
 E) CASEMENT WINDOWS.\
  
 F) ALL TRUSS CONNECTORS SPECIFIED ON
 PLANS.
  
 G) HORIZONTAL SLIDER WINDOWS.
  
 H) BUTT GLAZING SYSTEM OR WINDOW
 ASSEMBLIES AS SHOWN ON MASTER BEDROOM,
 LIVING ROOM AND BREAKFAST AREA.
  
 I) FRENCH DOORS AS SHOWN ON PLANS.
  
 13- PROVIDE FRAMING DETAILS AND SPECS
 FOR CONSTRUCTION OF WALL ABOVE WINDOW IN
 BREAKFAST AREA. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 14- OWES $4247.67 FOR PERMIT FEES AND
 RADON FEES.
  
 15- ENERGY CALCULATIONS: A) THIS IS A
 MODEL HOUSE. NEED ENERGY CALCULATIONS
 FOR WORST CASE SCENARIO OR CALCULATIONS
 SHALL BE DONE WITH SPECIFIC HOUSE
 ORIENTATION IN LOT TO BE BUILT.
  
 B) OVERHANG LENGHT AND OVERHANG HEIGHT
 ARE INCORRECT. SEE PLANS AND ELEVATIONS
 AND REVISE ACCORDINGLY. SEE ATTACHED
 SKETCH SHOWING HOW OVERHANG LENGTH AND
 HEIGHT ARE CALCULATED.
  
 C) OWNER/AGENT TO SIGN AND DATE FORM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2006-10-23 Cont ID  
Sent By btrobaug Date 2006-10-23 Time 15:46 Rev Time 0.50
Received By btrobaug Date 2006-10-23 Time 15:41 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 7 Status F Date 2006-10-19 Cont ID  
Sent By btrobaug Date 2006-10-19 Time 07:16 Rev Time 0.50
Received By btrobaug Date 2006-10-19 Time 06:25 Sent To PC
Notes
2006-10-19 07:13:59REVISION DENIED
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} THE RISER DIAGRAM INDICATES PANEL "P" BEING FED FROM
 PANEL "A". THE PANEL SCHEDULE INDICATES PANEL "P" FED
 FROM PANEL "B", PLEASE CORRELATE.
  
 2} THE FEED TO PANEL "P" MUST CONTAIN AN EQUIPMENT
 GROUND PER 250.122, #10CU.
  
 3} THE QUALITY OF THE REVISION SUBMITTED IS
 INSUFFICIENT FOR RECORD RETANTION PER 106.1.3 FBC AS
 AMENDED.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2006-05-16 Cont ID  
Sent By btrobaug Date 2006-05-16 Time 17:54 Rev Time 0.50
Received By btrobaug Date 2006-05-16 Time 17:41 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-05-12 Cont ID  
Sent By btrobaug Date 2006-05-12 Time 08:09 Rev Time 0.33
Received By btrobaug Date 2006-05-12 Time 08:09 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-04-21 Cont ID  
Sent By btrobaug Date 2006-04-21 Time 18:12 Rev Time 0.50
Received By btrobaug Date 2006-04-21 Time 18:12 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-04-04 Cont ID  
Sent By dpalmer Date 2006-04-04 Time 13:41 Rev Time 0.00
Received By dpalmer Date 2006-04-04 Time 13:29 Sent To PC
Notes
2006-04-04 00:00:00REV'S FOR BT OUT OF OFFICE.
  
 REDLINED SD LOCATION IN MASTER BEDRM TO
 BE WITHIN 12" OF THE HIGHEST POINT ON A
 FLAT CEILING. NFPA-72 11.8..3.5
  
 METER/ PANELS ARE BACK TO BACK, VIF.
  
  
 CIRCUIT FOR UTIL/HALL LTS, SHOWS 15A OCP
 ON #12, WHICH IS OK.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-07-27 Cont ID  
Sent By btrobaug Date 2005-07-27 Time 11:06 Rev Time 0.50
Received By btrobaug Date 2005-07-27 Time 10:44 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-03-24 Cont ID  
Sent By btrobaug Date 2005-03-24 Time 14:55 Rev Time 0.50
Received By btrobaug Date 2005-03-24 Time 13:40 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 11 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By adarroug Date 2006-10-10 Time 19:39 Sent To  
Notes
2006-10-10 19:39:56TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-05-15 Cont ID  
Sent By adarroug Date 2006-05-15 Time 15:02 Rev Time 0.00
Received By adarroug Date 2006-05-15 Time 15:02 Sent To E
Notes
2006-05-15 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-05-06 Cont ID  
Sent By adarroug Date 2006-05-06 Time 16:01 Rev Time 0.00
Received By adarroug Date 2006-05-06 Time 16:01 Sent To E
Notes
2006-05-06 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-04-12 Cont ID  
Sent By adarroug Date 2006-04-12 Time 16:30 Rev Time 0.00
Received By adarroug Date 2006-04-12 Time 16:30 Sent To E
Notes
2006-04-12 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-04-03 Cont ID  
Sent By adarroug Date 2006-04-03 Time 09:06 Rev Time 0.00
Received By adarroug Date 2006-04-03 Time 09:06 Sent To E
Notes
2006-04-03 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-03-31 Cont ID  
Sent By adarroug Date 2006-03-31 Time 16:37 Rev Time 0.00
Received By adarroug Date 2006-03-31 Time 16:37 Sent To M
Notes
2006-03-31 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-11-15 Cont ID  
Sent By adarroug Date 2005-11-15 Time 15:53 Rev Time 0.00
Received By adarroug Date 2005-11-15 Time 15:53 Sent To B
Notes
2005-11-15 00:00:00TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-09-20 Cont ID  
Sent By adarroug Date 2005-09-20 Time 12:27 Rev Time 0.00
Received By adarroug Date 2005-09-20 Time 12:27 Sent To M
Notes
2005-09-20 00:00:00TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-06-21 Cont ID  
Sent By adarroug Date 2005-06-21 Time 16:09 Rev Time 0.00
Received By adarroug Date 2005-06-21 Time 16:09 Sent To M
Notes
2005-06-21 00:00:00TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-03-24 Cont ID  
Sent By adarroug Date 2005-03-24 Time 10:50 Rev Time 0.00
Received By adarroug Date 2005-03-24 Time 10:50 Sent To E
Notes
2005-03-24 00:00:00TO "SFR""E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-03-22 Cont ID  
Sent By adarroug Date 2005-03-22 Time 08:01 Rev Time 0.00
Received By adarroug Date 2005-03-22 Time 08:01 Sent To  
Notes
2005-03-22 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-04-03 Cont ID  
Sent By tgordon Date 2006-04-03 Time 11:35 Rev Time 0.25
Received By tgordon Date 2006-04-03 Time 11:35 Sent To  
Notes
2006-04-03 00:00:00REVISION TO MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-09-20 Cont ID  
Sent By tgordon Date 2005-09-20 Time 16:04 Rev Time 0.30
Received By tgordon Date 2005-09-20 Time 16:04 Sent To P
Notes
2005-09-20 00:00:00MECHANICAL PLANS SUBMITTED AND ENERGY
 CALCULATIONS, BUT NO MECHANICAL
 CONTRACTOR AT THIS TIME.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2005-07-05 Cont ID  
Sent By pkrauss Date 2005-07-05 Time 10:31 Rev Time 0.30
Received By pkrauss Date 2005-07-05 Time 10:23 Sent To B
Notes
2005-07-05 00:00:00DENIED: 2ND REQUEST
 COMMENT #2 FROM PREVIOUS REVIEW WAS NOT
 ADDRESSED:
  
 PROVIDE HVAC SIZING CALCULATION (MANUAL
 J CALC) IN ACCORDANCE 2001 FBC CHAPTER
 13 SUB SECTION 607.1.ABC.1.PLANS ARE
 OTHERWISE CODE COMPLIANT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2005-03-26 Time   Rev Time 0.00
Received By hmoser Date 2005-03-26 Time 13:35 Sent To P
Notes
2005-03-26 00:00:00PLAN DENIED
 1) REFER TO SECTION 610.1.ABD.3.5.2 #1
 CHAPTER 13 FLORIDA ENERGY CODE
 2) PLEASE SUBMIT A COPY OF THE PAGE IN
 THE ARI.MANUAL FOR A/C EQUIPMENT.
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-04-06 Cont ID  
Sent By jleech Date 2005-04-06 Time 17:24 Rev Time 0.50
Received By jleech Date 2005-04-06 Time 17:24 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-03-23 Cont ID  
Sent By mmclean Date 2005-03-23 Time 16:18 Rev Time 0.00
Received By mmclean Date 2005-03-23 Time 16:18 Sent To I
Notes
2005-03-23 00:00:00NOTE: MUST PULL SEPERATE PERMIT FOR
 POOL/DECK/SCREEN ENCLOSURE