| Plan Review Stops For Permit 05031185 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2008-07-23 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2008-07-23 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2008-07-23 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2008-07-23 17:50:25 | "TEMPORARY FAIL" STATUS:WILL BE CHANGED TO "PASS" | | | WHEN ADDITIONAL PALM BEACH COUNTY IMPACT FEES ARE PAID | | | FOR THE INCREASE IN FLOOR AREA. | | | | | | | | | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | REVISION FOR INCREASE IN NUMBER OF STORIES FROM 5 TO 8 | | | STORIES. | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | | | | IMPACT FEES. COMMENT RESPONSE, STATING THAT THE OWNER | | | WILL PAY IMPACT FEES, IS NOTED AND THIS OFFICE WILL | | | DROP THIS COMMENT ONCE THE FEES ARE PAID. PREVIOUS | | | COMMENT (RE-STATED HERE FOR INFORMATION):THE PROPOSED | | | INCREASE IN BUILDING AREA WILL INCREASE THE IMPACT FEES | | | DUE.THE PLANS SHALL BE TAKEN TO PALM BEACH COUNTY | | | BUILDING DEPARTMENT FOR CALCULATION OF THE ADDITIONAL | | | IMPACT FEES. THEY SHALL BE STAMPED AT THAT OFFICE AND A | | | COPY OF THE PAID RECEIPT SUBMITTED TO THE CITY OF WEST | | | PALM BEACH DEPT OF CONSTRUCTION SERVICES BEFORE THE | | | REVISED PLANS CAN BE STAMPED. | | | | | | | | | --PROVISO-- | | | FBC 13-103.3EXTERIOR DOORS ON ENERGY CALCULATIONS. | | | SUBMIT REVISED ENERGY CALCULATIONS AND INPUT DATA | | | REPORT SHOWING THE INPUT FOR ALL EXTERIOR DOORS.SHEET | | | 10 OF THE INPUT DATA REPORT DOES NOT CURRENTLY REFLECT | | | THE NUMBER AND TYPE OF EXTERIOR DOORS SHOWN ON THE | | | PLANS. | | | | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE: | | | (561) 805 6652ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2008-07-12 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2008-07-12 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2008-07-12 |
Time |
12:34 |
Sent To |
|
|
| Notes |
| 2008-07-12 13:29:45 | "TEMPORARY FAIL" STATUS:FORMAL RESUBMITTAL IS NOT | | | NECESSARY HOWEVER THE REVIEW WILL REMAIN IN TEMPORARY | | | FAIL STATUS UNTIL COMMENT # 4 IS ADDRESSED AND THE | | | ADDITIONAL PALM BEACH COUNTY IMPACT FEES ARE PAID FOR | | | THE INCREASE IN FLOOR AREA. | | | | | | | | | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | 5TH REVIEW OF REVISION FOR INCREASE IN NUMBER OF | | | STORIES FROM 5 TO 8 STORIES. | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS ARE NUMBERED AS | | | PER THE BUILDING PLAN REVIEW OF 5/24/08: | | | | | | | | | 3)IMPACT FEES. COMMENT RESPONSE, STATING THAT THE | | | OWNER WILL PAY IMPACT FEES, IS NOTED AND THIS OFFICE | | | WILL DROP THIS COMMENT ONCE THE FEES ARE PAID. PREVIOUS | | | COMMENT (RE-STATED HERE FOR INFORMATION):THE PROPOSED | | | INCREASE IN BUILDING AREA WILL INCREASE THE IMPACT FEES | | | DUE.THE PLANS SHALL BE TAKEN TO PALM BEACH COUNTY | | | BUILDING DEPARTMENT FOR CALCULATION OF THE ADDITIONAL | | | IMPACT FEES. THEY SHALL BE STAMPED AT THAT OFFICE AND A | | | COPY OF THE PAID RECEIPT SUBMITTED TO THE CITY OF WEST | | | PALM BEACH DEPT OF CONSTRUCTION SERVICES BEFORE THE | | | REVISED PLANS CAN BE STAMPED. | | | | | | | | | THE FOLLOWING COMMENT CAN BE ADDRESSED WITHOUT FORMAL | | | SUBMITTAL OF PLANS BUT IT MUST BE ADDRESSED BEFORE THE | | | PLAN REVIEW CAN BE "PASSED": | | | | | | 4) FBC 709.2.4COLUMN FIRE RESISTANCE RATING.SHEET | | | S-9 HAS BEEN REVISED TO SHOW COLUMN TC-5 WITH ADEQUATE | | | DIMENSIONS TO ACHIEVE THE REQUIRED 3 HOUR FIRE | | | RESISTANCE RATING.HOWEVER THE SHEET WAS CORRECTED | | | USING CORRECTION FLUID ("WITE-OUT").IT IS PERMISSIBLE | | | FOR PLANS FOR PERMITTING PURPOSES TO BE REVISED BY THE | | | DESIGNER OF RECORD USING HAND WRITTEN CHANGES PROVIDED | | | THE DESIGNER OF RECORD SIGNS AND DATES NEXT TO EACH | | | CHANGE, HOWEVER UNDER NO CIRCUMSTANCE CAN CORRECTION | | | FLUID BE USED FOR PLAN REVISION PURPOSES.ONCE THE | | | PLANS ARE STAMPED THERE WOULD BE NO WAY FOR THE | | | INSPECTOR TO KNOW IF THE CORRECTION FLUID WAS APPLIED | | | BEFORE OR AFTER STAMPING ("PASSING") OF THE PLANS.THE | | | ENGINEER SHALL SUBMIT THREE COPIES OF SHEET S-9 WITH | | | THE DIMENSIONS OF COLUMN TC-5 REVISED AS PROPOSED. THIS | | | COMMENT MAY BE ADDRESSED WITHOUT FORMAL RESUBMITTAL OF | | | PLANS.THE CONTRACTOR CAN SIMPLY BRING THE REVISED | | | SHEETS TO THIS OFFICE AND INSERT THEM INTO THE SETS. | | | | | | | | | --PROVISO-- | | | FBC 13-103.3EXTERIOR DOORS ON ENERGY CALCULATIONS. | | | SUBMIT REVISED ENERGY CALCULATIONS AND INPUT DATA | | | REPORT SHOWING THE INPUT FOR ALL EXTERIOR DOORS.SHEET | | | 10 OF THE INPUT DATA REPORT DOES NOT CURRENTLY REFLECT | | | THE NUMBER AND TYPE OF EXTERIOR DOORS SHOWN ON THE | | | PLANS. | | | | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE: | | | (561) 805 6652ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2008-05-24 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2008-05-24 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2008-05-24 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2008-05-24 14:31:19 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW OF REVISION FOR INCREASE IN NUMBER OF | | | STORIES FROM 5 TO 8 STORIES. | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS ARE NUMBERED AS | | | PER THE BUILDING PLAN REVIEW OF 3/4/08: | | | | | | 3)IMPACT FEES. COMMENT RESPONSE, STATING THAT THE | | | OWNER WILL PAY IMPACT FEES, IS NOTED AND THIS OFFICE | | | WILL DROP THIS COMMENT ONCE THE FEES ARE PAID. PREVIOUS | | | COMMENT (RE-STATED HERE FOR INFORMATION):THE PROPOSED | | | INCREASE IN BUILDING AREA WILL INCREASE THE IMPACT FEES | | | DUE.THE PLANS SHALL BE TAKEN TO PALM BEACH COUNTY | | | BUILDING DEPARTMENT FOR CALCULATION OF THE ADDITIONAL | | | IMPACT FEES. THEY SHALL BE STAMPED AT THAT OFFICE AND A | | | COPY OF THE PAID RECEIPT SUBMITTED TO THE CITY OF WEST | | | PALM BEACH DEPT OF CONSTRUCTION SERVICES BEFORE THE | | | REVISED PLANS CAN BE STAMPED. | | | | | | 4) FBC TABLE 500ALLOWABLE BUILDING HEIGHT.FBC | | | 503.2.6 STATES THAT THE HEIGHT OF RESIDENTIAL | | | OCCUPANCY, IN BUILDINGS OF TYPE II CONSTRUCTION, CAN BE | | | UNLIMITED PROVIDED THE FIRE RESISTANCE OF ALL COLUMNS | | | IS NOT LESS THAN 3 HOURS.YOUR COMMENT MOST RECENT | | | RESPONSE LETTER HAS BEEN NOTED, HOWEVER COLUMN TC-5 ON | | | SHEET S-9 DOES NOT HAVE TWO PARALLEL SIDES AT LEAST 36 | | | INCHES LONG. EVEN ALLOWING FOR BOTH LEGS OF THIS | | | L-SHAPED COLUMN, ON SIDE IS 32 INCHES LONG.PREVIOUS | | | COMMENT (RE-STATED HERE FOR INFORMATION):CONCRETE | | | COLUMNS: SECTION 709.2.4 OF FBC 2001 REQUIRES A MINIMUM | | | CONCRETE COLUMN DIMENSION OF 12 INCHES FOR A 3 HOUR | | | FIRE RESISTANCE RATING, OR A MINIMUM CONCRETE COLUMN | | | DIMENSION OF 8 INCHES IF TWO PARALLEL SIDES ARE AT | | | LEAST 36 INCHES LONG.COLUMN TC-5, SHOWN ON SHEET S-9, | | | DOES NOT COMPLY WITH EITHER REQUIREMENT OPTION.REVISE | | | THE SIZE OF COLUMN TC-5 TO COMPLY WITH SECTION IS | | | 709.2.4 OF FBC 2001 | | | | | | 13) FBC 13-103.1.2THIS COMMENT HAS STILL NOT BEEN | | | ADDRESSED.THE SIGNATURE OF RAFAEL PENA IS STILL A | | | PHOTOCOPIED SIGNATURE.AN ORIGINAL (WET) SIGNATURE | | | MUST BE PUT ON THESE ENERGY CALCULATIONS BY RAFAEL | | | PENA.WE NEED THREE COPIES OF THE ENERGY CODE | | | COMPLIANCE FORM, EACH WITH RAFAEL PENA'S ORIGINAL (WET) | | | SIGNATURE AND RAISED SEAL. | | | | | | 15) FBC 1606.1WIND LOADS ON PARKING STRUCTURE.THE | | | COMMENT RESPONSE, STATING THAT HARDING STEEL IS | | | CURRENTLY PRODUCING WIND LOAD CALCULATIONS, IS NOTED. | | | THE WIND LOAD DESIGN CRITERIA/CALCULATIONS SHALL BE | | | SUBMITTED FOR REVIEW.PREVIOUS COMMENT (RE-STATED HERE | | | FOR INFORMATION):THE SUBMITTAL FOR THE HARDING STEEL, | | | INC. PARKING STRUCTURE DOES NOT INCLUDE ANY WIND LOAD | | | DESIGN CRITERIA.THE STRUCTURE MUST BE DESIGNED TO | | | WITHSTAND A WIND SPEED OF 140 MPH (3 SECOND GUST). | | | SUBMIT WIND LOAD DESIGN CRITERIA/CALCULATIONS.ALL | | | STRUCTURAL SUBMITTALS MUST BE REVIEWED BY THE | | | STRUCTURAL ENGINEER OF RECORD FOR THE PROJECT AND | | | INCLUDE THE SHOP DRAWING REVIEW STAMP OF THAT | | | ENGINEER. | | | | | | NOTE: TO EXPEDITE REVIEW OF A RESUBMITTAL WHICH | | | REQUIRES NEW PLANS IN ORDER TO ADDRESS THE ABOVE | | | COMMENTS, THE OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD SHEET SHOULD BE | | | STAPLED/CLIPPED TO THE REMAINING OLD SHEETS, TO FORM A | | | SET OF 'OLD/VOID SHEETS', FOR COMPARISON OF REVISIONS | | | WHEN REVIEWING THE RESUBMITTED PLANS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE: | | | (561) 805 6652ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2008-03-04 |
Time |
19:25 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2008-03-04 |
Time |
19:25 |
Sent To |
|
|
| Notes |
| 2008-03-04 19:40:05 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW OF REVISION FOR INCREASE IN NUMBER OF | | | STORIES FROM 5 TO 8 STORIES. | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS ARE NUMBERED AS | | | PER THE BUILDING PLAN REVIEW OF 9/23/07: | | | | | | 3)IMPACT FEES. THE PROPOSED INCREASE IN BUILDING AREA | | | WILL INCREASE THE IMPACT FEES DUE.THE PLANS SHALL BE | | | TAKEN TO PALM BEACH COUNTY BUILDING DEPARTMENT FOR | | | CALCULATION OF THE ADDITIONAL IMPACT FEES. THEY SHALL | | | BE STAMPED AT THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT SUBMITTED TO THE CITY OF WEST PALM BEACH DEPT | | | OF CONSTRUCTION SERVICES BEFORE THE REVISED PLANS CAN | | | BE STAMPED. | | | | | | 4) FBC TABLE 500ALLOWABLE BUILDING HEIGHT.FBC | | | 503.2.6 STATES THAT THE HEIGHT OF RESIDENTIAL | | | OCCUPANCY, IN BUILDINGS OF TYPE II CONSTRUCTION, CAN BE | | | UNLIMITED PROVIDED THE FIRE RESISTANCE OF ALL COLUMNS | | | IS NOT LESS THAN 3 HOURS.YOUR COMMENT RESPONSE LETTER | | | HAS BEEN NOTED.STEEL COLUMNS: SHEET A-506 HAS BEEN | | | REVISED TO SHOW THE UL SYSTEM FOR FIRE RESISTANCE | | | RATING OF THE STEEL COLUMNS, BUT THE APPLICATION | | | THICKNESS TABLE REPRODUCED ON THE PLANS IS NOT LEGIBLE. | | | SHOW A LEGIBLE TABLE ON THE PLANS.ALSO, THE TABLE | | | COVERS MANY DIFFERENT FIRE RESISTANCE RATINGS, SOME OF | | | WHICH ARE LESS THAN 3 HOURS.THE PLANS SHALL CLEARLY | | | STATE, FOR THE CONTRACTOR AND INSPECTOR, THAT A 3 HOUR | | | FIRE RESISTANCE RATING IS REQUIRED FOR THE COLUMNS ON | | | THIS PROJECT.CONCRETE COLUMNS: THE COMMENT RESPONSE | | | LETTER STATES THAT THE COLUMN FIRE RESISTANCE RATING | | | HAS BEEN PROVIDED PER SECTION 709.2.1.1.1 OF FBC 2001. | | | THAT SECTION IS ACTUALLY FOR WALLS.THE APPLICABLE | | | SECTION FOR COLUMNS IS 709.2.4 OF FBC 2001 WHICH | | | REQUIRES A MINIMUM CONCRETE COLUMN DIMENSION OF 12 | | | INCHES FOR A 3 HOUR FIRE RESISTANCE RATING, OR A | | | MINIMUM CONCRETE COLUMN DIMENSION OF 8 INCHES IF TWO | | | PARALLEL SIDES ARE AT LEAST 36 INCHES LONG.COLUMN | | | TC-5, SHOWN ON SHEET S-9, DOES NOT COMPLY WITH EITHER | | | REQUIREMENT OPTION.REVISE THE SIZE OF COLUMN TC-5 TO | | | COMPLY WITH SECTION IS 709.2.4 OF FBC 2001 | | | | | | 13) FBC 13-103.1.2THIS COMMENT HAS STILL NOT BEEN | | | ADDRESSED.THE SUBMITTED REVISED ENERGY CODE | | | COMPLIANCE FORM SHALL BE SIGNED (ON PAGE 2) BY THE | | | BUILDING OWNER, THE OWNER'S ARCHITECT OR OTHER | | | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER. ALSO, | | | THREE SIGNED AND SEALED COPIES OF THE ENERGY CODE | | | COMPLIANCE FORM ARE REQUIRED BUT ALL THREE SUBMITTED | | | COPIES HAVE A PHOTOCOPY OF RAFAEL PENA'S SIGNATURE, AND | | | TWO ARE NOT SEALED.THE SIGNATURE MUST BE ORIGINAL AND | | | THE SEAL MUST BE AFFIXED. | | | | | | 15) FBC 1606.1WIND LOADS ON PARKING STRUCTURE.THE | | | SUBMITTAL FOR THE HARDING STEEL, INC. PARKING STRUCTURE | | | DOES NOT INCLUDE ANY WIND LOAD DESIGN CRITERIA.THE | | | STRUCTURE MUST BE DESIGNED TO WITHSTAND A WIND SPEED OF | | | 140 MPH (3 SECOND GUST).SUBMIT WIND LOAD DESIGN | | | CRITERIA/CALCULATIONS.ALL STRUCTURAL SUBMITTALS MUST | | | BE REVIEWED BY THE STRUCTURAL ENGINEER OF RECORD FOR | | | THE PROJECT AND INCLUDE THE SHOP DRAWING REVIEW STAMP | | | OF THAT ENGINEER. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE: | | | (561) 805 6652ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2007-09-23 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2007-09-23 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2007-09-23 |
Time |
18:35 |
Sent To |
|
|
| Notes |
| 2007-09-23 19:46:24 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW OF REVISION FOR INCREASE IN NUMBER OF | | | STORIES FROM 5 TO 8 STORIES. | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS ARE NUMBERED AS | | | PER THE BUILDING PLAN REVIEW OF 12/10/06: | | | | | | 1) FBC* 104.6.5BUILDING PERMIT VALUATION.THE | | | PROPOSED INCREASE IN BUILDING AREA WILL INCREASE THE | | | VALUE OF THE PROJECT FOR PERMIT FEE CALCULATION | | | PURPOSES.THE VALUE CURRENTLY STATED IS $5,362,279 AND | | | THE FEES PAID TO DATE WERE BASED ON THAT VALUE.THE | | | VALUE, CALCULATED USING THE SOUTHERN BUILDING CODE | | | CONGRESS INTERNATIONAL (SBCCI) VALUATION TABLES FOR THE | | | PROPOSED INCREASED BUILDING AREA, IS $8,268,362.IN | | | ORDER TO PROCEED WITH THE PROPOSED REVISION, THE PERMIT | | | APPLICATION FEE WOULD HAVE TO BE ADJUSTED ACCORDINGLY, | | | SO THERE WOULD BE AN OUTSTANDING BALANCE OF $32,257.53. | | | THIS ADDITIONAL FEE AMOUNT WILL HAVE TO BE PAID BEFORE | | | THE PLANS REVISED PLANS CAN BE STAMPED. | | | | | | 2) RADON FEES.THE PROPOSED INCREASE IN BUILDING AREA | | | WILL INCREASE THE RADON FEES.THE RADON FEES PAID TO | | | DATE AMOUNT TO $532.96.THE TOTAL RADON FEES FOR THE | | | PROPOSED BUILDING AREA WOULD BE $799.72.THE | | | DIFFERENCE IS $266.76 AND THIS AMOUNT WOULD HAVE TO BE | | | PAIDBEFORE THE REVISED PLANS CAN BE STAMPED. | | | | | | 3)IMPACT FEES. THE PROPOSED INCREASE IN BUILDING AREA | | | WILL INCREASE THE IMPACT FEES DUE.THE PLANS SHALL BE | | | TAKEN TO PALM BEACH COUNTY BUILDING DEPARTMENT FOR | | | CALCULATION OF THE ADDITIONAL IMPACT FEES. THEY SHALL | | | BE STAMPED AT THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT SUBMITTED TO THE CITY OF WEST PALM BEACH DEPT | | | OF CONSTRUCTION SERVICES BEFORE THE REVISED PLANS CAN | | | BE STAMPED. | | | | | | 4) FBC TABLE 500ALLOWABLE BUILDING HEIGHT.CONTRARY | | | TO THE SUBMITTED RESPONSE LETTER, THE ARCHITECTURAL | | | PLANS DO NOT SHOW THAT THE COLUMNS WILL HAVE 3-HOUR | | | FIRE RESISTANCE RATING.THERE IS NO NOTE IN THE | | | ARCHOTECTURAL OR STRUCTURAL PLANS STATING THAT THE | | | COLUMN FIRE RESISTANCE RATING IS 3-HOURS.NO "VOIDED" | | | (PREVIOUSLY REVIEWED) STRUCTURAL SHEETS, AND NOT ALL | | | "VOIDED" ARCHITECTURAL SHEETS, WERE SUBMITTED FOR | | | COMPARISON WITH THE PROPOSED PLANS, AND SHEETS S-1 AND | | | S-2 DO NOT INDICATE ANY CHANGE TO THE COLUMN SIZES. | | | 3-HOUR FIRE RESISTANCE RATED COLUMNS ARE REQUIRED | | | THROUGHOUT THE BUILDING BECUSE FOR RESIDENTIAL | | | OCCUPANCY (INCLUDING R-1 HOTEL) THE MAXIMUM HEIGHT OF A | | | BUILDING OF TYPE II CONSTRUCTION IS 80 FEET UNLESS | | | FOOTNOTE (A) ALLOWS HEIGHT MODIFICATION. FOOTNOTE | | | (A)(7) REFERS TO FBC 503.2.6 FOR RESIDENTIAL OCCUPANCY. | | | FBC 503.2.6 STATES THAT THE HEIGHT OF RESIDENTIAL | | | OCCUPANCY, IN BUILDINGS OF TYPE II CONSTRUCTION, CAN BE | | | UNLIMITED PROVIDED THE FIRE RESISTANCE OF ALL COLUMNS | | | IS NOT LESS THAN 3 HOURS. THE PROPOSED HEIGHT OF THE | | | BUILDING DOES EXCEED 80 FEET, SO THE PLANS MUST BE | | | AMENDED TO SHOW ALL COLUMNS TO HAVE A FIRE RESISTANCE | | | RATING OF NOT LESS THAN THREE HOURS. | | | | | | 6) FBC 412.6.1ELEVATOR LOBBY DOORS ARE REQUIRED TO | | | HAVE A 20-MINUTE FIRE-RESISTANCE RATING.THE NOTE | | | ADDED TO SHEET A-125 DOES SHOW A REQUIREMENT FOR A | | | 20-MINUTE FIRE RESISTANCE RATED DOOR AT THE ELEVATOR | | | LOBBY/CORRIDOR BUT IT HAS NO ANNOTATION AT THE ELEVATOR | | | LOBBY/VESTIBULE.ALSO, THE DOOR SCHEDULE HAS NOT BEEN | | | UPDATED TO CORRELATE WITH THIS REQUIREMENT.DOORS | | | 299D, 299E, 399C, 399E, 499C, 499E, 599C, 599E, 699C, | | | 699E, 799C, 799E, 899C AND 899E ARE ALL REQUIRED TO BE | | | 20-MINUTE DOORS.THE DOOR SCHEDULE ON SHEET A-604 DOES | | | NOT SHOW THESE DOORS AS FIRE RESISTANCE RATED.AMEND | | | THE DOOR SCHEDULE TO CLEARLY SHOW THE REQUIRED FIRE | | | RESISTANCE RATINGS FOR THESE DOORS.20-MINUTE FIRE | | | RESISTANCE RATED DOORS ARE REQUIRED BECAUSE THE | | | BUILDING AS REVISED WILL BE CLASSIFIED AS 'HIGH RISE' | | | BECAUSE IT WILL HAVE OCCUPIED FLOORS MORE THAN 75 FEET | | | ABOVE FIRE DEPARTMENT ACCESS LEVEL.1-HOUR FIRE | | | RESISTANT ELEVATOR LOBBIES, WITH 20-MINUTE LOBBY DOORS, | | | ARE REQUIRED ON ALL FLOORS ABOVE THE MAIN ENTRANCE | | | LEVEL. | | | | | | 11) FBC 11-4.1.3(5)ELEVATOR ACCESS TO ROOF UPPER | | | DECK.IT IS NOTED THAT SHEET A-111 HAS BEEN REVISED TO | | | SHOW AN ACCESSIBLE RAMP FROM THE UPPER DECK TO THE | | | LOWER DECK.HOWEVER, NO DETAILS HAVE BEEN SUBMITTED TO | | | SHOW COMPLIANCE WITH RAMP SLOPE, LANDING AND HANDRAIL | | | REQUIREMENTS. | | | | | | 13) FBC 13-103.1.2THIS COMMENT HAS NOT BEEN | | | ADDRESSED.THE SUBMITTED REVISED ENERGY CODE | | | COMPLIANCE FORM SHALL BE SIGNED (ON PAGE 2) BY THE | | | BUILDING OWNER, THE OWNER'S ARCHITECT OR OTHER | | | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER. ALSO, | | | THREE SIGNED COPIES OF THE ENERGY CODE COMPLIANCE FORM | | | ARE REQUIRED. | | | | | | 14) FBC* 104.2.1CROSS-SECTIONS A-302/B-B AND | | | A-304/D-D HAVE NOT BEEN UPDATED TO REFLECT THE FACT THE | | | THAT ELEVATOR STOPS AT THE UPPER DECK LEVEL AND THAT | | | THERE IS NOW AN ACCESSIBLE RAMP FROM THE UPPER DECK TO | | | THE LOWER DECK. | | | | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE: | | | (561) 805 6652ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-12-11 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-12-10 |
Time |
19:54 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-12-10 |
Time |
19:54 |
Sent To |
|
|
| Notes |
| 2006-12-10 20:39:02 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | REVISION TO INCREASE THE NUMBER OF STORIES FROM 5 TO 8 | | | STORIES. | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | 1) FBC* 104.6.5BUILDING PERMIT VALUATION.THE | | | PROPOSED INCREASE IN BUILDING AREA WILL INCREASE THE | | | VALUE OF THE PROJECT FOR PERMIT FEE CALCULATION | | | PURPOSES.THE VALUE CURRENTLY STATED IS $5,362,279 AND | | | THE FEES PAID TO DATE WERE BASED ON THAT VALUE.THE | | | VALUE, CALCULATED USING THE SOUTHERN BUILDING CODE | | | CONGRESS INTERNATIONAL (SBCCI) VALUATION TABLES FOR THE | | | PROPOSED INCREASED BUILDING AREA, IS $8,268,362.IN | | | ORDER TO PROCEED WITH THE PROPOSED REVISION, THE PERMIT | | | APPLICATION FEE WOULD HAVE TO BE ADJUSTED ACCORDINGLY, | | | SO THERE WOULD BE AN OUTSTANDING BALANCE OF $32,257.53. | | | THIS ADDITIONAL FEE AMOUNT WILL HAVE TO BE PAID BEFORE | | | THE PLANS REVISED PLANS CAN BE STAMPED. | | | | | | 2) RADON FEES.THE PROPOSED INCREASE IN BUILDING AREA | | | WILL INCREASE THE RADON FEES.THE RADON FEES PAID TO | | | DATE AMOUNT TO $532.96.THE TOTAL RADON FEES FOR THE | | | PROPOSED BUILDING AREA WOULD BE $799.72.THE | | | DIFFERENCE IS $266.76 AND THIS AMOUNT WOULD HAVE TO BE | | | PAIDBEFORE THE REVISED PLANS CAN BE STAMPED. | | | | | | 3)IMPACT FEES. THE PROPOSED INCREASE IN BUILDING AREA | | | WILL INCREASE THE IMPACT FEES DUE.THE PLANS SHALL BE | | | TAKEN TO PALM BEACH COUNTY BUILDING DEPARTMENT FOR | | | CALCULATION OF THE ADDITIONAL IMPACT FEES. THEY SHALL | | | BE STAMPED AT THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT SUBMITTED TO THE CITY OF WEST PALM BEACH DEPT | | | OF CONSTRUCTION SERVICES BEFORE THE REVISED PLANS CAN | | | BE STAMPED. | | | | | | 4) FBC TABLE 500ALLOWABLE BUILDING HEIGHT.FOR | | | RESIDENTIAL OCCUPANCY (INCLUDING R-1 HOTEL) THE MAXIMUM | | | HEIGHT OF A BUILDING OF TYPE II CONSTRUCTION IS 80 FEET | | | UNLESS FOOTNOTE (A) ALLOWS HEIGHT MODIFICATION. | | | FOOTNOTE (A)(7) REFERS TO FBC 503.2.6 FOR RESIDENTIAL | | | OCCUPANCY.FBC 503.2.6 STATES THAT THE HEIGHT OF | | | RESIDENTIAL OCCUPANCY, IN BUILDINGS OF TYPE II | | | CONSTRUCTION, CAN BE UNLIMITED PROVIDED THE FIRE | | | RESISTANCE OF ALL COLUMNS IS NOT LESS THAN 3 HOURS. THE | | | PROPOSED HEIGHT OF THE BUILDING DOES EXCEED 80 FEET, SO | | | THE PLANS MUST BE AMENDED TO SHOW ALL COLUMNS TO HAVE A | | | FIRE RESISTANCE RATING OF NOT LESS THAN THREE HOURS. | | | | | | 5) FBC 412.6ELEVATOR LOBBIES.THE BUILDING AS | | | REVISED WILL BE CLASSIFIED AS 'HIGH RISE' BECAUSE IT | | | WILL HAVE OCCUPIED FLOORS MORE THAN 75 FEET ABOVE FIRE | | | DEPARTMENT ACCESS LEVEL.1-HOUR FIRE RESISTANT | | | ELEVATOR LOBBIES, WITH 20-MINUTE LOBBY DOORS, ARE | | | REQUIRED ON ALL FLOORS ABOVE THE MAIN ENTRANCE LEVEL. | | | ANNOTATE THE PLANS TO CLARIFY THE PURPOSE OF THE | | | ROOM/LOBBYIMMEDIATELY SOUTH OF THE ELEVATOR LOBBY | | | | | | 6) FBC 412.6.1ELEVATOR LOBBY DOORS ARE REQUIRED TO | | | HAVE A 20-MINUTE FIRE-RESISTANCE RATING.DOORS 299D, | | | 299E, 399C, 399E, 499C, 499E, 599C, 599E, 699C, 699E, | | | 799C, 799E, 899C AND 899E ARE ALL REQUIRED TO BE | | | 20-MINUTE DOORS.THE DOOR SCHEDULE ON SHEET A-604 DOES | | | NOT SHOW THESE DOORS AS FIRE RESISTANCE RATED.ALSO, | | | IS 299D THE CORRECT DOOR REFERENCE, OR SHOULD IT BE | | | 299C TO MATCH WHAT IS CALLED OUT ON THE OTHER FLOORS? | | | AMEND THE DOOR SCHEDULE TO CLEARLY SHOW THE REQUIRED | | | FIRE RESISTANCE RATINGS FOR THESE DOORS. | | | | | | 7) FBC 412.6.1 ELEVATOR LOBBY WALLS.SHEET A-125, | | | TYPICAL LIFE SAFETY PLAN, DOES NOT SHOW THE REQUIRED | | | 1-HOUR FIRE RESISTANCE RATING FOR THE NORTH AND SOUTH | | | WALLS OF THE ELEVATOR LOBBISE.AMEND THE PLAN. | | | | | | 8) FBC 412.6.2OPENINGS IN THE ELEVATOR LOBBY.NO | | | SERVICE ROOMS, CLOSETS ETC. SHALL OPEN INTO THE | | | ELEVATOR LOBBY.ANNOTATE THE PLANS TO CLARIFY THE | | | PURPOSE OF THE ROOM/LOBBYIMMEDIATELY SOUTH OF THE | | | ELEVATOR LOBBY | | | | | | 9) FBC 412.6.3ELEVATOR LOBBY SMOKE DETECTION.SHEETS | | | FA-3, TYPICAL FIRE ALARM FLOOR PLAN, SHOWS NO SMOKE | | | DETECTOR IN THE ELEVATOR LOBBIES.AN APPROVED SMOKE | | | DETECTOR SHALL BE LOCATED ON THE CEILING OF EVERY | | | ELEVATOR LOBBY.AMEND THE PLAN TO CLEARLY SHOW THE | | | NECESSARY ELEVATOR LOBBY SMOKE DETECTION. | | | | | | 10) FBC 11-9.1.2ACCESSIBLE SLEEPING ROOMS.SHEET | | | A-102 HAS BEEN REVISED TO OMIT THE ACCESSIBLE SLEEPING | | | ACCOMMODATION FROM SUITE 105 SO THAT FACILITY MUST BE | | | PROVIDED ELSEWHERE IN THE BUILDING.IT IS NOTED THAT | | | SHEET A-104 NOW CALLS OUT SUITE 200 AS "SLEEPING | | | ACCOMMODATIONS WITH SPECIAL ACCESSIBILITY FEATURE | | | (ROLL-IN SHOWER", BUT NO ROLL-IN SHOWER IS SHOWN. AMEND | | | THE PLAN. | | | | | | 11) FBC 11-4.1.3(5)ELEVATOR ACCESS TO ROOF UPPER | | | DECK.SHEET A-111 HAS BEEN REVISED TO SHOW ACCESS BY | | | WHEELCHAIR LIFT.ACCESS TO ALL LEVELS, INCLUDING THE | | | ROOF UPPER DECK,SHALL BE BY PASSENGER ELEVATOR, OR AN | | | ACCESSIBLE RAMP MUST BE PROVIDED.WHEECHAIR LIFTS ARE | | | ONLY PERMITTED WHEN ONE OF THE CONDITIONS OF EXCEPTION | | | 4 APPLIES.AS NONE OF THOSE CONDITIONS APPLY HERE, THE | | | PLANS SHALL BE AMENDED TO SHOW ACCESS TO THE ROOF UPPER | | | DECK BY BOTH ELEVATORS OR BY ACCESSIBLE RAMP. | | | | | | 12) FBC 11-4.1.2(5) AND 11-4.6.5SHEET A-101, REVISED | | | PARKING TABLE, AND SHEET A-204.ANNOTATE THE PLAN TO | | | CLARFIY HOW THE PROPOSED PARKING STRUCTURE WILL BE | | | USED.IS THE PARKING STRUCTURE FOR USE BY VALET ONLY? | | | IF SO, THEN AN ACCESSIBLE PASSENGER LOADING ZONE | | | COMPLYING WITH FBC 11-4.6.6 LOCATED ON AN ACCESSIBLE | | | ROUTE TO THE BUILDING ENTRANCE IS REQUIRED.IF THE | | | PARKING STRUCTURE IS NOT FOR USE BY VALET ONLY, AND IT | | | IS A COVERED PARKING FACILITY UNDER A ROOF, PLEASE NOTE | | | THAT 5 OF THE PROPOSED 134 PARKING SPACES ARE SHOWN AS | | | UNCOVERED.ALL 5 ARE ACCESSIBLE SPACES, SO NO COVERED | | | ACCESSIBLE PARKING IS BEING PROVIDED.EITHER A | | | PRORATED NUMBER OF THE ACCESSIBLE PARKING SPACES SHALL | | | BE COVERED PARKING FOR HANDICAPPED PERSONS, OR VALET | | | PARKING WITH THE AFOREMENTIONED ACCESSIBLE PASSENGER | | | LOADING ZONE, IS REQUIRED.ALSO PLEASE CONSIDER THAT, | | | FOR SELF-PARKING, ONE IN EIGHT (NOT LESS THAN ONE) OF | | | THE SPACES IN THE PARKING STRUCTURE SHALL BE VAN | | | ACCESSIBLE COMPLYING WITH FBC 11-4.6.5.ANNOTATE THE | | | PLANS TO CLARFIY WHETHER VALET PARKING WILL BE PROVIDED | | | AND HOW THE PROPOSED PARKING STRUCTURE WILL BE USED. | | | | | | 13) FBC 13-103.1.2THE SUBMITTED REVISED ENERGY CODE | | | COMPLIANCE FORM SHALL BE SIGNED (ON PAGE 2) BY THE | | | BUILDING OWNER, THE OWNER'S ARCHITECT OR OTHER | | | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER. | | | ALSO, THREE SIGNED COPIES OF THE ENERGY CODE COMPLIANCE | | | FORM ARE REQUIRED. | | | | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE: | | | (561) 805 6652ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-08-20 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-08-20 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-08-20 |
Time |
12:50 |
Sent To |
Z |
|
| Notes |
| 2006-08-20 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | SITE PLAN (SHEET A-101) AND FOUNDATION | | | PLAN (SHEET S-1) AND DETAIL SHEET (SHEET | | | S-2) REVISION FOR ADDITION OF THREE | | | STORIES (6TH, 7TH AND 8TH FLOORS) TO THE | | | BUILDING. | | | | | | 1) FBC* 104.6THE DECLARED BUILDING | | | VALUE SHALL BE INCREASED TO ACCOUNT FOR | | | THE THREE ADDITIONAL STORIES AND THE | | | STRENGTHENING OF THE | | | STRUCTURE/FOUNDATION TO SUPPORT THEM. | | | THE PERMIT FEES WILL THEN BE ADJUSTED | | | ACCORDINGLY. | | | | | | 2) IMPACT FEES AND RADON FEES.PLEASE | | | NOTE THAT ADDITIONAL IMPACT FEES AND | | | RADON FEES WILL BE DUE FOR THE INCREASE | | | IN BUILDING AREA. | | | | | | 3) FBC 11-4.1.2(5) AND 11-4.6.5SHEET | | | A-101, REVISED PARKING TABLE.ANNOTATE | | | THE PLAN TO CLARFIY HOW THE PROPOSED | | | PARKING STRUCTURE WILL BE USED.IS THE | | | PARKING STRUCTURE FOR USE BY VALET ONLY? | | | IF SO, THEN AN ACCESSIBLE PASSENGER | | | LOADING ZONE COMPLYING WITH FBC 11-4.6.6 | | | LOCATED ON AN ACCESSIBLE ROUTE TO THE | | | BUILDING ENTRANCE IS REQUIRED. | | | IF THE PARKING STRUCTURE IS NOT FOR USE | | | BY VALET ONLY, PLEASE NOTE THAT EIGHT OF | | | THE PROPOSED 146 PARKING SPACES ARE | | | SHOWN AS UNCOVERED.SO IT IS ASSUMED | | | THAT THE PARKING STRUCTURE WILL PROVIDE | | | THE REMAINING SPACES AS COVERED PARKING. | | | IN THAT CASE, A PORTION OF THE | | | ACCESSIBLE PARKING SPACES SHALL BE IN | | | THE PARKING STRUCTURE TO PROVIDE COVERED | | | PARKING FOR HANDICAPPED PERSONS.ALSO, | | | ONE IN EIGHT (NOT LESS THAN ONE) OF THE | | | SPACES IN THE PARKING STRUCTURE SHALL BE | | | VAN ACCESSIBLE COMPLYING WITH FBC | | | 11-4.6.5. ANNOTATE THE PLAN TO CLARFIY | | | HOW THE PROPOSED PARKING STRUCTURE WILL | | | BE USED. | | | | | | 4)FOUNDATION TYPE.THE PLANS | | | PREVIOUSLY SHOWED CONCRETE FOOTINGS FOR | | | COLUMNS AND WALLS AND A 4" CONCRETE | | | FIRST FLOOR SLAB.THE REVISED SHEET S-1 | | | NOW INCLUDES A NOTE CALLING OUT A 30" | | | THICK CONCRETE MAT FOUNDATION BUT IT | | | ALSO STILL SHOWS A NOTE CALLING OUT A 4" | | | CONCRETE SLAB. WHAT IS THE FOUNDATION | | | FOR COLUMNS TC-3, TC-6, TC-7 ETC AND FOR | | | THE SPIRAL STAIRS.ANNOTATE THE PLAN | | | AND PROVIDE CROSS SECTION DETAILS TO | | | CLARIFY THE EXTENT OF THE MAT FOUNDATION | | | AND THEPROPOSED FOUNDATION AND SLAB | | | ARRANGEMENT. | | | | | | 5) FBC* 104.2.1SHEET S-2 WAS | | | PREVIOUSLY THE MEZZANINE FRAMING PLAN. | | | THE DETAILS SHOWN ON THE REVISED SHEET | | | S-2 WERE PREVIOUSLY SHOWN ON SHEET S-9. | | | IS THAT INTENTIONAL?PLEASE NOTE THAT | | | THE NEW VERSION OF S-2 (STRUCTURAL | | | DETAILS) WILL REPLACE THE PREVIOUS S-2 | | | (MEZZANINE FRAMING PLAN) SUCH THAT THERE | | | IS NO LONGER A MEZZANINE FRAMING PLAN. | | | PLEASE CORRECT OR CLARIFY. | | | | | | 6) FBC* 104.2.1SHEETS S-1 AND S-2. | | | WHEN SUBMITTING REVISED PLANS, PLEASE | | | USE REVISION MARKERS (AND 'CLOUDS') TO | | | CLEARLY SHOW WHAT AREAS HAVE BEEN | | | REVISED. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6652ROBERT BROWN | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-31 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-08-31 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-08-18 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2005-08-18 00:00:00 | **** NEEDS NOC AND IMPACT FEE **** | | | BEFORE PERMIT ISSUANCE | | | | | | 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | IMPACT FEES. THE ARCHITECT'S RESPONSE | | | MEMO, DATED 7/7/05, STATES THAT THE | | | IMPACT FEE STAMP IS ALREADY ON SHEET | | | A-101 AND A-102.THAT IS NOT CORRECT. | | | THE PLANS SHALL BE TAKEN TO PALM BEACH | | | COUNTY BUILDING DEPARTMENT FOR IMPACT | | | FEE ASSESSMENT. THEY SHALL BE STAMPED AT | | | THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-02 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-06-02 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-05-31 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2005-05-31 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | | | | 1) 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2) IMPACT FEES. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | | | 3) FBC* 105.13.1SPECIAL INSPECTOR | | | AGREEMENT.THE SUBMITTED AGREEMENT | | | LISTS THE WEITZ COMPANY AS CONTRACTOR | | | (SHOULD BE J RAYMOND CONSTRUCTION CORP), | | | HAS NO ORIGINAL SIGNATURES OR RAISED | | | SEALS AND REFERS TO THE OLD PERMIT# | | | 03121642.SUBMIT THREE (3) COPIES OF A | | | NEW SPECIAL INSPECTOR AGREEMENT.THE | | | AGREEMENT SHALL INCLUDE THE NEW PERMIT | | | NUMBER (05031185) AND SHALL BE SIGNED BY | | | AN AUTHORIZED SIGNATORY FOR J. RAYMOND | | | CONSTRUCTION CORP.ORIGINAL SIGNATURES | | | ARE REQUIRED (WITH RAISED SEALS FOR | | | ENGINEERS/ARCHITECTS) | | | | | | 4) FBC 13-103.1.2BEFORE A BUILDING | | | PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHITECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | ALSO, THE SIGNATURE OF RAFAEL PENA IS A | | | COPY.AN ORIGINAL SIGNATURE IS | | | REQUIRED. | | | | | | 5) FBC 2803PACKAGED TERMINAL AIR | | | CONDITIONER (PTAC), SECTIONS A-401/1 TO | | | A-402/4 AND S-11/1 TO S-11/3.SUBMIT | | | DETAILS TO SHOW HOW THE PTAC AND | | | ALUMINUM LOUVER WILL PREVENT WIND-DRIVEN | | | RAIN FROM ENTERING THE BUILDING. | | | | | | 6) FBC* 2111.1.9WATER STOP, DETAIL | | | A-503/4 AND SECTIONS A-301 TO A-402 AND | | | S-11/1 TO S-11/2.THE REQUIRED 1.5" | | | SLAB RECESS IS NOT SHOWN.AMEND THE | | | PLANS OR MAKE A PROPOSAL, FOR | | | CONSIDERATION UNDER FBC* 103.7 ALTERNATE | | | MATERIALS AND METHODS, FOR | | | WATER-PROOFING THE 'COLD JOINT' BETWEEN | | | WALL AND SLAB. | | | | | | 7) FBC 707.1 CONCEALED SPACES IN TYPE II | | | CONSTRUCTION.SHEETS A-503 AND A-502 | | | DETAIL 11, SHOW WOOD BLOCKING.ALL | | | BUCKS, HEADERS, BLOCKING AND FIRRING | | | STRIPS ETC SHALL BE FIRE RETARDANT | | | TREATED LUMBER IN TYPE I, II AND IV | | | CONSTRUCTION.AMEND/ANNOTATE THE PLANS. | | | | | | 8) FBC 1606.1TRUSS ANCHOR SCHEDULE, | | | SHEET S-9 AND SHEET S-11 SECTION 2.A | | | COMBINED CAPACITY FOR TWO (2) SIMPSON | | | META 22 OF 2900# IS STATED ON THE | | | SCHEDULE.THIS EXCEEDS THE MAX. (TWO | | | ANCHOR) COMBINED UPLIFT OF 2565# ALLOWED | | | IN THE 2005 SIMPSON CATALOGUE.AMEND | | | THE SCHEDULE. | | | | | | 9) THE SUBMITTED GAF BUILT-UP ROOFING | | | PRODUCT APPROVAL (STATEWIDE# FL618 AND | | | MIAMI-DADE NOA# 00-0403.02) COVERS | | | SYSTEMS WITH DESIGN PRESSURE RATINGS | | | THAT RANGE FROM -45 PSF TO 457.5 PSF, SO | | | SOME OF THE SYSTEMS ARE NOT SUITABLE FOR | | | THIS PROJECT.MARK THE NOA TO SHOW | | | WHICH SYSTEM IS PROPOSED SO THAT THAT | | | THE DESIGN PRESSURE CAN BE COMPARED WITH | | | THE CALCULATED PRESSURES FOR THE | | | BUILDING. | | | | | | 10) FBC 1606.1.4IMPACT RATING OF | | | SINGLE HUNG WINDOWS.THE SUBMITTED PGT | | | SINGLE HUNG WINDOW STATEWIDE PRODUCT | | | APPROVAL FL239 COVERS NON-IMPACT, SMALL | | | MISSILE IMPACT AND LARGE MISSILE IMPACT. | | | THE MIAMI-DADE PRODUCT APPROVAL (NOA# | | | 02-0123.04) THAT WAS SUBMITTED, IS FOR | | | SMALL MISSILE IMPACT RATED WINDOWS, SO | | | IT IS NOT APPLICABLE FOR THE WINDOWS | | | BELOW 30 FEET ABOVE GRADE.SUBMIT THREE | | | COPIES OF A PRODUCT APPROVAL FOR LARGE | | | MISSILE IMPACT RATED WINDOWS. | | | | | | 11) TO EXPEDITE REVIEW OF A RESUBMITTAL | | | WHICH REQUIRES NEW PLANS IN ORDER TO | | | ADDRESS THE ABOVE COMMENTS, THE OLD | | | SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | | REMAINING OLD SHEETS, TO FORM A SET OF | | | 'OLD/VOID SHEETS', FOR COMPARISON OF | | | REVISIONS WHEN REVIEWING THE RESUBMITTED | | | PLANS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2008-07-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-02 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-01 |
Time |
17:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2008-04-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-23 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-23 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2008-04-23 11:53:51 | ** DENIED 4TH TIME FOR REVISIONS ** | | | | | | ** PLEASE SEE SOME OF THE NOTES FROM THE PREVIOUS | | | REVIEW ARE STILL IN NEED OF ADDRESSING. | | | ** PLEASE ALSO SEE NEW COMMENTS BASED ON DOCUMENTS | | | FINALLY SUBMITTED FOR REVIEW WHICH WERE NOT SUBMITTED | | | PREVIOUSLY. | | | ** PLEASE ALSO SEE NEW COMMENTS WITH RESPECT TO SIGNED | | | AND SEALED DOCUMENTS SUBMITTED WITHOUT ORIGINAL | | | SIGNATURES. | | | | | | 1) NOTE: PLEASE SE PREVIOUS REVIEW WITH RESPECT TO | | | PHOTO-METRICS AND COORDINATION OF FIXTURES. PLEASE SEE | | | SOME EXAMPLES GIVEN ONCE AGAIN AS THERE ARE FIXTURES ON | | | PLANS WHICH ARE NOT ON THE PHOTO-METRICS OR FIXTURES ON | | | PHOTO-METRICS WHICH ARE NOT THE SAME AS THE LIGHTING | | | PLANS. SOME EXAMPLES ARE GIVEN BELOW. | | | FOR EXAMPLE: | | | PLEASE SEE SHEET E-1 WHICH SHOWS FE FIXTURES ON PLANS | | | AND PHOTO-METRICS YET THE FIXTURE SCHEDULE ON THAT SAME | | | SHEET STATES FIXTURES F1E. | | | FOR EXAMPLE: | | | PLEASE SEE SHEET E-4 WHICH SHOWS COMPLETELY DIFFERENT | | | LIGHT FIXTURES AND DIFFERENT LIGHT FIXTURE LOCATIONS | | | THAN THE LIGHTING SHOWN ON THE PHOTO-METRIC SHEET E-4A | | | FOR THIS SAME ROOF-TOP PLAN. | | | PLEASE SEE THE FIXTURE TYPES ON E-4A ARE NOT THE SAME | | | AND MUCH COORDINATION IS NEEDED. | | | PLEASE SEE LS 101 7.8, 7.9 | | | FBC 106.1.23 FOR COORDINATION AND ADDITIONAL | | | INFORMATION. | | | | | | 2) NOTE: PLEASE SEE THERE ARE SIX SETS OF ENERGY | | | CALCULATIONS SUBMITTED. (3-OLD SETS AND 3-NEWS SETS) | | | PLEASE SEE IN EITHER CASE NONE OF THESE CONTAIN | | | ORIGINAL SIGNATURES BY THE ENGINEER OF RECORD. IN FACT | | | FOUR OF THE 6 SUBMITTED CONTAIN A RAISED SEAL OVER | | | PHOTO-COPIED SIGNATURES WHICH ARE IN VIOLATION OF | | | FLORIDA STATUTES 471.025 AND FLORIDA ADMINISTRATIVE | | | CODE 61G15-23.002. PLEASE KNOW THESE MAY BE RETAINED BY | | | THIS OFFICE AND FORWARDED TO THE FLORIDA BOARD OF | | | ENGINEERS AND LEGAL COUNSEL TO THE BOARD. *SHALL NOT | | | PLACE A RAISED SEAL OVER PHOTO-COPIED SIGNATURES IN ANY | | | SITUATION.* | | | | | | 3) NOTE: PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED | | | DO NOT COORDINATE WITH THE LIGHTING AS SHOWN ON PLANS. | | | PLEASE SEE 2001 FBC 13-400.1.A, 13-415.2 ETC | | | PLEASE SEE THE FOLLOWING IS AN EXAMPLE FOR ITEMS WHICH | | | DO NOT COMPLY OR COORDINATE WITH PLANS. THE INPUT DATA | | | REPORT WILL BE NOTED AS IDR | | | FOR EXAMPLE: | | | PLEASE SEE THE LIGHTING SHOWN FOR EXTERIOR ON PLANS IS | | | SUBSTANTIALLY MORE THAN THE LIGHTING SHOWN ON THE IDR. | | | THE WATTAGES OF THE FIXTURES SHOWN ON PLANS IN | | | FOLLOWING AREAS SUCH AS PARKING LOT, DRIVEWAY, POOL | | | AREA, DECK, OUTSIDE WALL LIGHTS ON GROUND FLOOR AND | | | UPPER ROOF AREAS ETC IS WAY MORE THAN THE LIGHTING | | | SHOWN ON THE IDR. PLEASE SEE THE TOTAL WATTAGE ON THE | | | IDR FOR EXTERIOR LIGHTS SHOWS 887WATTS, YET THE | | | LIGHTING FOR DRIVE AREA ALONE IS 1800WATTS. | | | FOR EXAMPLE: | | | PLEASE SEE THE LIGHTING ON E-1 FOR THE EXTERIOR OF THE | | | BUILDING. WHERE ARE THESE FIXTURES ON THE IDR? THEY ARE | | | NOT PLACED IN THE IDR. | | | THIS DOES NOT EVEN INCLUDED DOZENS AND DOZENS OF OTHER | | | FIXTURES WHICH ARE MISSING FROM THE IDR ALTOGETHER. | | | HOW IS THIS POSSIBLE? | | | PLEASE SEE THE CODE REQUIRES THESE FIXTURES TO BE | | | PLACED INTO THE IDR. | | | | | | 4) NOTE: PLEASE SEE THE PREVIOUS REVIEWS REQUESTED THE | | | MANUFACTURES SPECS/CUT SHEETS FOR THE FIRE PUMP AND | | | FIRE PUMP CONTROLLER. THIS IS THE FIRST REVIEW IN WHICH | | | THESE DOCUMENTS WERE SUBMITTED. | | | PLEASE SEE THE LISTING STATED ON THESE DOCUMENTS | | | INDICATE A ULC LISTING WHICH IS UNDERWRITERS | | | LABORATORIES OF CANADA. | | | PLEASE KNOW THIS LISTING IS NOT A RECOGNIZED EQUIPMENT | | | TO BE USED IN THE UNITED STATES. THE LISTING WOULD BE | | | REQUIRED TO SHOW A C UL US LISTED OR OTHER NATIONALLY | | | RECOGNIZED TESTING LABORATORY (NRTL). PLEASE SEE OSHA | | | FOR LATEST LISTING FOR PRODUCTS AND LISTINGS WHICH ARE | | | ACCEPTABLE IN THE US. | | | WE HAVE ATTACHED A COPY OF THE INFORMATION FROM UL | | | WHICH CLEARLY SHOWS THE ULC IS NOT AN APPROVED LISTING | | | IN THE US. | | | | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2008-02-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-02-06 |
Time |
19:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-02-06 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2008-02-06 19:23:23 | 2008-02-06 19:23:23 | | | | | | ** DENIED REVISIONS FOR THIRD REVIEW ** | | | | | | CLARKES HOTEL | | | REVISIONS FROM PREVIOUS PERMITTED 5 STORY TO 8-STORY | | | HIGH RISE. | | | | | | ** PLEASE SEE MANY NOTES FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING. | | | PLEASE SEE SOME NEW COMMENTS BASED ON NEW SUBMITTED | | | DOCUMENTS NOT PREVIOUSLY SUBMITTED FOR REVIEW. PLEASE | | | SEE SOME OF THE SAME EXACT SHEETS THIS REVIEWER | | | PERSONALLY REDLINED FROM PREVIOUS REVIEW WERE SUBMITTED | | | BACK IN NEW SETS WITHOUT ANY CHANGES. | | | THIS REVIEWER HAS PLACED DIRECT PHONE NUMBER AND E-MAIL | | | ADDRESS ON ALL PREVIOUS REVIEWS AND NO CONTACT WAS MADE | | | TO GO OVER ANY OF THESE ITEMS SINCE THE LAST REVIEW. | | | | | | | | | | | | 1) NOTE:AS REQUESTED ON ALL PREVIOUS REVIEWS:PLEASE | | | SUBMIT ALL THE MANUFACTURE SPECS/CUT SHEETS FOR ALL OF | | | THE FOLLOWING. PLEASE SUBMIT FOR; FIRE PUMP, FIRE PUMP | | | CONTROLLER, GENERATOR, FUEL TANK. (SEENOTES BELOW), | | | ATS EQUIPMENT (SEENOTES BELOW). 110.3, 90.7.PLEASE | | | KNOW AT THIS TIME THERE ARE SEVERAL ITEMS WHICH REMAIN | | | UNANSWERED FOR REQUIRED CODE ITEMS AND COORDINATION OF | | | PLANS WITH OUT THESE ITEMS. | | | PLEASE SEE THERE ARE SEVERAL ITEMS IN NFPA-110 AND | | | NFPA-20 WHICH CAN NOT BE REVIEWED FOR COMPLIANCE AND | | | COORDINATION WITHOUT THESE DOCUMENTS BEING SUBMITTED. | | | | | | 2) NOTE: AS REQUESTED ON ALL PREVIOUS REVIEW:PLEASE | | | SUBMIT COMPLETE PHOTO-METRICS FOR ALL EGRESS PATHS | | | WHICH MEET THE MINIMUM LIFE SAFETY CODE7.8.1.3, | | | 7.9.2.2. THE MINIMUM LEVELS UNDER THE THESE SECTIONS | | | REQUIRE 10FT CANDLE MIN FOR STAIRS UNDER NORMAL AND 1FT | | | CANDLE UNDER EMERGENCY. | | | PLEASE SEE FOR EXAMPLE EGRESS STAIRS A SPECIFICALLY | | | MENTIONED ON PREVIOUS REVIEWS WHICH STILL SHOW LESS | | | THAN THE MINIMUM OF 10FT CANDLES UNDER NORMAL. PLEASE | | | SEE SHEET E-4A WHICH IS THE SAME EXACT SHEET WHICH WAS | | | PREVIOUSLY SUBMITTED. THIS SHEETS STILL CONTAINS | | | REDLINES BY REVIEWER ALONG WITH NEW REDLINES TO HELP | | | RESOLVE. | | | PREVIOUS REVIEW ALSO MENTIONED TO SHOW LEVELS UNDER | | | BOTH EMERGENCY AND NORMAL. | | | PREVIOUS REVIEWS ALSO REQUESTED COORDINATION BETWEEN | | | FIXTURES FROM THE PHOTO-METRICS TO LIGHTING PLANS FOR | | | FIXTURE TYPES. FOR EXAMPLE: PLEASE SEE THE SAME EXACT | | | SHEETS FOR SHEET E-1 WERE SUBMITTED BACK WITH THIS | | | REVIEWERS SAME REDLINED FIXTURES WHICH CLEARLY SHOW HE | | | AND DE FIXTURES ON LIGHTING PLANS AND YET THE SAME | | | SHEET FOR THE SAME FIXTURES ON THE PHOTO-METRICS | | | INDICATE FE AND EE FIXTURES. HOW IS THIS POSSIBLE? | | | WHICH FIXTURES ARE PROPOSED? | | | PLEASE SEE FAC 61G15-33.004. THIS SECTION OF THE | | | FLORIDA ADMINISTRATIVE CODE IS WITH RESPECT TO MINIMUM | | | REQUIREMENTS FOR LIGHTING DESIGN BY THE ENGINEERING | | | PROFESSIONAL. | | | | | | 3) NOTE: PLEASE KNOW BASED ON THE NEW ELECTRICAL DATA | | | SUBMITTED FOR THE PARKING LIFT SYSTEM, ALL EQUIPMENT | | | MUST BE LISTED ASSEMBLY. THE DOCUMENTS CLEARLY STATE UL | | | LISTED COMPONENTS OR PARTS, HOWEVER COULD NOT LOCATE | | | ANY LISTING FOR SYSTEM CONTROL PANELS ETC. | | | PLEASE SUBMIT LISTED SYSTEM DOCUMENTS OR KNOW THE | | | SYSTEM WILL BE REQUIRED TO BE LISTED BY A NRTL( | | | NATIONALLY RECOGNIZED TESTING LABORATORY) BEFORE FINAL. | | | THIS WOULD INCLUDE ALL INSTALLED AT RISK WITH *PROVISO* | | | TO OBTAIN LISTINGS. | | | 110.3 | | | | | | 4) NOTE: PLEASE KNOW FOR INFORMATIONAL PURPOSES THE | | | LIGHTNING PROTECTION SYSTEM NOTED ON PLANS WILL BE | | | REQUIRED TO BE SUBMITTED UNDER SEPARATE PLANS AND | | | PERMIT. | | | ALL WORK SHALL BE PER NFPA-780 AND MASTER LABEL SHALL | | | ALSO BE MADE AVAILABLE TO THE CITY FOR RECORD PLANS. | | | | | | 5) NOTE: PLEASE SEE NO REVISED FBC ENERGY CALCULATIONS | | | WERE SUBMITTED AS REQUIRED PER FBC CHAPTER 13. PLEASE | | | KNOW AS THE FIXTURES HAVE CHANGED AND ENERGY | | | CONSUMPTION HAS CHANGED, THIS WILL AFFECT THE | | | STRUCTURE. PLEASE SUBMIT THESE ENERGY CALCULATIONS | | | BASED ON THE 2001 CODE WHICHIS WHAT THIS PROJECT IS | | | PERMITTED UNDER. | | | FBC CHAPTER 13, 13-400.1.A, 13-415.2 ETC | | | | | | 6) NOTE: PLEASE VERIFY THE SMOKE DEVICES IN UNITS ARE | | | IN FACT SMOKE DETECTORS AS SHOWN OR SMOKE ALARMS PER | | | NFPA-72. PLANS CAME BACK STILL SHOWING THESE AS SMOKE | | | DETECTORS. IF THESE DEVICES DETECT SMOKE AND SOUND AN | | | ALARM FROM THE UNIT ITSELF THEN THIS IS A SMOKE *ALARM* | | | AND NOT DETECTOR. A SMOKE DETECTOR ONLY DETECTS AND | | | DOES NOT SOUND AN ALARM. BASED ON PLANS AND DESIGN, IF | | | THESE WERE SMOKE DETECTORS, EACH UNIT WOULD REQUIRE A | | | FIRE ALARM PANEL. | | | PLEASE CALL TO GO OVER THIS IF THERE ARE STILL ANY | | | QUESTIONS. | | | | | | 7) NOTE: AS REQUESTED ON ALL PREVIOUS REVIEWS: PLEASE | | | SUBMIT THE REVISED FIXTURE SCHEDULE/LEGEND WHICH IS NOT | | | ON ELECTRICAL PLANS. PLEASE BE SURE TO COORDINATE ALL | | | INFORMATION ON THE FIXTURE LEGEND WITH THAT OF THE | | | INPUT DATA REPORT ON UPDATED ENERGY CALCULATIONS TO BE | | | SUBMITTED. | | | ORIGINAL PLANS CLEARLY DID CONTAIN THE INFORMATION AND | | | WAS REMOVED. | | | FBC CHAPTER 13, NFPA-101, NFPA-70 ETC | | | FBC 104.1.2 | | | | | | 8) NOTE:THIS NOTE IS FOR INFORMATION ONLY: PLEASE | | | KNOW BASED ON THE OCCUPANCY USE AT THIS TIME NEWLY | | | PASSED HOUSE BILL 7121 DOES NOT APPLY HOWEVER GIVEN | | | INFORMATION AT THIS TIME IF THE USE WAS TO CHANGE FROM | | | HOTEL TO CONDOS, THEN HB 7121 WOULD APPLY. | | | THIS IS ONLY NOTED FOR INFORMATION ONLY AND NO CHANGE | | | NEEDS TO MADE TO PLANS FOR CURRENT USE. | | | | | | 9) NOTE: AS STATED ON THE PREVIOUS REVIEW:PLEASE SEE | | | NFPA-110 CHAPTER 7,7.2.3 FOR MIN ELEVATION REQUIRED | | | FOR ALL EPSS EQUIPMENT INCLUDING GEN. | | | PLEASE PROVIDE MIN LEVELS FOR "SLOSH" ( SEA, LAKE, | | | OVERLAND , SURGES, BY HURRICANES) CHARTS BASED ON A CAT | | | 4 STORM OR THE 100YR ELEVATION ON PLANS. | | | THE RESPONSE MENTIONS, BUILDING LOCATED ABOVE FLOOD | | | LEVEL. PLEASE KNOW HOWEVER THE MINIMUM LEVEL FOR EPSS | | | EQUIPMENT BASED ON THE CHARTS NOTED ABOVE NEEDS TO BE | | | STATED AND SHOWN ON PLANS. PLEASE SEE NO ELEVATIONS ON | | | ELECTRICAL PLANS FOR LIFE SAFETY EQUIPMENT IS BEING | | | SHOWN. (FIRE PUMP ON MEZZANINE LEVEL IS NOT NEEDED) AS | | | THIS IS A GIVEN DUE TO ITS LOCATION. | | | SAME NOTE: | | | | | | 10) NOTE:PLEASE SEE THE GROUNDING ELECTRODE FOR THE | | | FIRE PUMP SERVICE HAS NOW BEEN REMOVED?? | | | PREVIOUS NOTE WAS WITH RESPECT TO THE SIZE OF THE | | | GROUNDING ELECTRODE CONDUCTOR BEING TOO SMALL AND NOW | | | IT CAN NOT BE LOCATED? | | | PLEASE ALSO SEE THE FEEDER SCHEDULE INDICATES AN | | | *EQUIPMENT GROUNDING CONDUCTOR* NOW FROM THE FPL | | | TRANSFORMER TO THE FIRST MEANS OF DISCONNECT WHICH IS | | | NOT PERMITTED PER 250.6 AND 250.24. | | | PLEASE CALL TO GO OVER THIS SCENARIO IN ORDER TO MAKE | | | THE NEEDED ADJUSTMENTS. | | | PLEASE SEE 250.50, 250.66 ETC | | | | | | 11) NOTE: PLEASE SEE THE FUEL TANK IS NOW SHOWN AS 400 | | | GALLONS ON THE FUEL CALCULATIONS AND 500 GALLONS ON | | | RISER UNDER GENERATOR? | | | WHICH ONE IS IT? | | | PLEASE SEE NOTES ABOVE WITH RESPECT TO THE SUBMISSION | | | OF MANUFACTURES SPECS/CUT SHEETS. | | | FBC 104.1.2 FOR COORDINATION OF PLANS. | | | | | | 12) NOTE: PLEASE SEE THE FP SHEETS SHALL STATE THE CODE | | | RELEVANT FOR DESIGN. THIS COULD BE REDLINED IF THIS WAS | | | THE ONLY COMMENT ON SHEET FP-1 THIS SHOULD REFLECT 1999 | | | NFPA-20 ( CAN NOT BE LATEST EDITION AS THERE IS MOST | | | CERTAINLY ONE NEW NFPA-20ALREADY ADOPTED BY THE STATE | | | AND WILL HAVE ANOTHER NEW CODE ADOPTED BY THE STATE | | | BEFORE FINAL. | | | | | | 13) NOTE: AS REQUESTED ON PREVIOUS REVIEWS: THIS | | | COMMENT WILL REMAIN AS THE INFORMATION WHICH WILL BE | | | SUBMITTED ON GENERATOR WILL CONFIRM AVAILABLE FAULT | | | CURRENT ON THE GENERATOR. THE LEVELS ON THE MANUFACTURE | | | SPECS/CUT SHEETS WILL ALSO BE REVIEWED. | | | PLEASE PROVIDE ALL AIC RATINGS FOR ALL EQUIPMENT, ATS, | | | DISCONNECTS ETC. PLEASE SEE 701.6, NFPA-20 6-3.2.2.4, | | | 110.9, 240.12 ETC. PLEASE SEE NFPA-110 6.5.2 ETC. | | | PLEASE BE SURE ALL EQUIPMENT/MANUFACTURE SPECS/CUT | | | SHEETS SHOWS THIS COORDINATION. | | | THE MOST IMPORTANT PART OF THIS COMMENT IS THE | | | SELECTIVE COORDINATION REQUIRED FOR LIFE SAFETY SYSTEMS | | | AS NOTED ON PREVIOUS REVIEW PER 240.12 OF THE NEC AND | | | OTHER SECTIONS OF NFPA-110 ETC | | | PLEASE SUBMIT THE SELECTIVE COORDINATION STUDY FOR THE | | | REQUIRED AND LIFE SAFETY SYSTEMS. | | | FAC 61G15-33.003 | | | FBC 104.1.2 FOR ADDITIONAL INFORMATION. | | | | | | 14) NOTE:PLEASE SEE PREVIOUS REVIEWS REQUESTED THE | | | MINIMUM LEVELS FOR ADA COMPLIANCE WITH RESPECT TO HORN | | | AND STROBE LEVELS. THE PLANS DO NOT SHOW ALL LEVELS, | | | HOWEVER SYMBOL LEGEND WAS REVISED FOR STROBE LEVELS. | | | THE NOTES HOWEVER FOR HORN AND SOUND LEVELS STATE | | | LEVELS SHALL MEET NFPA-72. THIS IS TRUE TO A POINT AS | | | THEY ARE REQUIRED TO MEET THE MINIMUM LEVELS PER | | | NFPA-72 HOWEVER THE LEVELS PER THE FBC ARE MORE | | | RESTRICTIVE WHICH WOULD APPLY. | | | PLEASE ADJUST LEVELS AND NOTES. | | | SECTIONS GIVEN IN PREVIOUS REVIEWS: PLEASE PROVIDE ALL | | | MINIMUM AUDIBLE AND VISUAL LEVELS PER FBC 2001 11-4.28, | | | 11-4.28.2 AND MOST IMPORTANT 11-4.28.3(4). ALL AREA AS | | | STATED IN 11-4.28.1 SHALL BE NOTED AND INCLUDED. | | | | | | 15) NOTE: PLEASE KNOW A RESPONSE LETTER FROM DESIGN | | | TEAM IS NOT REQUIRED HOWEVER DOES HELP IN THE REVIEW | | | PROCESS. AS CONTACT WAS NOT MADE WITH THIS OFFICE SINCE | | | LAST REVIEW PLEASE SEE NOTE BELOW. | | | | | | AS STATED ON THE PREVIOUS REVIEW: | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-24 |
Time |
17:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-14 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2007-09-17 16:51:24 | **** NOTE ADDED*** | | | | | | 1) NOTE: PLEASE SEE FBC 2001, CHAPTER 13, | | | 415.1.ABCD.1.1.4 FOR REQUIRED MISSING MASTER LIGHTING | | | CONTROL SWITCH. | | | ** PLEASE SEE LIGHTING PERFORMANCE CALCULATIONS IN | | | 13-415.2 | | | PLEASE SEE ALL REQUIREMENTS FOR THE 2001 FBC CHAPTER 13 | | | WHICH ARE REQUIRED TO BE MET. | | | | | | THIS COMMENT WAS NOT MADE ON PREVIOUS REVIEW HOWEVER IT | | | IS REQUIRED OF THE DESIGN TEAM TO MEET THE MINIMUM | | | REQUIREMENTS OF THE FBC. | | 2007-08-24 18:00:11 | 2007-08-24 18:00:11 | | | | | | *** DENIED2ND REVIEW OF REVISIONS *** | | | | | | *** PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEW ARE | | | STILL IN NEED OF ADDRESSING ALONG WITH NEW COMMENTS | | | BASED ON SOME INFORMATION ON REVISED PLANS. | | | | | | ** REVIEW FOR REVISION OF CLARKES HOTEL FROM 5-STORIES | | | TO 8 STORIES. | | | | | | ** PLEASE KNOW THAT AT THIS TIME THERE IS NOT ENOUGH | | | INFORMATION SUBMITTED FOR A COMPLETE REVIEW FOR CODE | | | COMPLIANCE AS THE BUILDING HAS NOW BEEN CLASSIFIED AS A | | | HIGH-RISE. | | | PLEASE SEE SOME ITEMS WERE NOT SUBMITTED AS PREVIOUSLY | | | REQUESTED FOR REVIEW. | | | | | | | | | 1) NOTE:THIS IS THE SAME NOTE AS SOME SHEETS STILL | | | ONLY INDICATE LESS REVISIONS THAN THE PROJECT HAS | | | PLEASE SEE THAT ALL REVISIONS ON PLANS SHALL BE DATED, | | | CLOUDED/TRIANGLE NOTATIONS ACCORDINGLY. PLEASE SEE | | | DATES AND REVISION NUMBERS SHOW A REV #1, HOWEVER THIS | | | HAS BEEN REVISED AT LEAST THREE OR FOUR TIMES. HOW IS | | | THIS FIRST REVISION?? | | | | | | 2) NOTE: PLEASE CLARIFY HOW SHEET E-3 BE TYPICAL FOR | | | ALL FLOORS WHEN THE FLOOR PLAN LAYOUT FOR THE | | | ELECTRICAL ROOMS ARE DIFFERENT. THE LARGER ROOMS WOULD | | | INDEED AFFECT THE FLOOR PLANS FOR LAYOUTS OF WALLS, | | | SPACES ETC. | | | PLEASE PROVIDE EACH. | | | FBC 104.1.2 | | | | | | 3) NOTE: AS REQUESTED ON THE PREVIOUS REVIEW:PLEASE | | | SUBMIT ALL THE MANUFACTURE SPECS/CUT SHEETS FOR ALL OF | | | THE FOLLOWING. PLEASE SUBMIT FOR; FIRE PUMP, FIRE PUMP | | | CONTROLLER, GENERATOR, FUEL TANK. (SEENOTES BELOW), | | | ATS EQUIPMENT (SEENOTES BELOW). 110.3, 90.7 PLEASE | | | KNOW AT THIS TIME THERE ARE SEVERAL ITEMS WHICH REMAIN | | | UNANSWERED FOR REQUIRED CODE ITEMS AND COORDINATION OF | | | PLANS WITH OUT THESE ITEMS. | | | | | | 4) NOTE: AS REQUESTED ON PREVIOUS REVIEW: | | | PLEASE SUBMIT COMPLETE PHOTO-METRICS FOR ALL EGRESS | | | PATHS. (ALL CORRIDORS AND STAIR TOWERS) PLEASE SEE | | | LS-1017.8.1.3, 7.9.2.2 10FT CANDLE MIN FOR STAIRS UNDER | | | NORMAL AND 1FT CANDLE UNDER EMERGENCY. | | | PLEASE SEE THERE ARE SEVERAL STAIR AREAS WHERE NO | | | PHOTO-METRIC LEVELS WERE SUBMITTED FOR REVIEW. PLEASE | | | ALSO SEE THAT THE COMMENT REQUESTED THE LEVELS UNDER | | | NORMAL AND UNDER EMERGENCY. | | | PLEASE SEE SOME STAIR AREAS WHICH SHOW LEVELS ARE UNDER | | | THE MINIMUM AS REQUIRED PER THE LIFE SAFETY CODE UNDER | | | NORMAL. | | | PLEASE SUBMIT THESE FOR ALL EGRESS PATHS TO THE PUBLIC | | | RIGHT OF WAY AWAY FROM BUILDING. | | | ** EXAMPLE: PLEASE SEE STAIRS FROM MEZZANINE LEVEL TO | | | REAR OF BUILDING ON E-2, PLEASE SEE ROOF PLANS FROM | | | POOL AREA WHICH CONTAINS STAIRS HOWEVER NO LEVELS WERE | | | SHOWN. | | | ** IMPORTANT: PLEASE SEE NOW THE PHOTO-METRICS HAVE | | | BEEN SUBMITTED AND FIGURED SHOWING DIFFERENT FIXTURES | | | THAN THAT ON PLANS FOR THE SAME LOCATIONS. | | | FE, IS HE ETC. | | | FAC 61G15-33.004 | | | | | | 5) NOTE:THIS NOTE REMAINS AS IT IS NOT KNOWN WHETHER | | | OR NOT PLANS AND PERMITTING FOR GARAGE WILL BE REQUIRED | | | AT THIS TIME. | | | PLEASE SEE ZONING COMMENTS, PLEASE SEE IF A GARAGE IS | | | NOW REQUIRED, THIS WILL COMPLETELY CHANGE ELECTRICAL | | | SERVICE AND ELECTRICAL SHEETS SUBMITTED. | | | | | | 6) NOTE: PLEASE VERIFY THE SMOKE DEVICES IN UNITS ARE | | | IN FACT SMOKE DETECTORS AS SHOWN OR SMOKE ALARMS PER | | | NFPA-72. | | | PLEASE SEE AS SHOWN WITH THE 120V POWER AND IF THERE | | | ARE DETECTION AND SOUNDING DEVICES THESE WOULD IN FACT | | | BE *SD* FOR SMOKE ALARMS. | | | PLEASE KNOW THAT A STATEMENT WAS ISSUED FROM NFPA THAT | | | THESE DEVICES SHALL BE CLEARLY IDENTIFIED FOR USE AND | | | THE GENERAL ACCEPTANCE OF USING SD FOR ACTUAL SMOKE | | | ALARMS SHOULD BE ADDRESSED. | | | | | | 7) NOTE: AS REQUESTED ON PREVIOUS REVIEW: PLEASE SEE | | | ALL FIXTURE SCHEDULE AND TYPE INFORMATION WHICH WAS ON | | | PREVIOUS PLANS HAS BEEN REMOVED FOR EM FIXTURES? PLEASE | | | SEE ALL OF THE FOLLOWING IN ORDER TO REVIEW FOR CODE | | | COMPLIANCE SHALL BE PLACED BACK ON PLANS. | | | LS 101. | | | THE RESPONSE MENTIONS THIS WAS NOT DONE, HOWEVER PLEASE | | | SEE THE ORIGINAL PERMITTED SETS OF PLANS CLEARLY | | | INDICATE THIS SCHEDULE/LEGEND ON SHEET E1. | | | PLEASE SEE THE FIXTURE LEGEND ON SHEET E-6 DOES NOT | | | CLEARLY INDICATE THE BATTERY BACK UP FOR CERTAIN | | | FIXTURES WHICH WAS INDICATE ON LEGEND ON PREVIOUS | | | PLANS. | | | PLEASE SEE COMMENT #4 ABOVE WITH RESPECT TO THE | | | DIFFERENCES ON PLANS IF LIGHTING FIXTURES. | | | | | | 8) NOTE:AS REQUESTED ON PREVIOUS REVIEW: | | | PLEASE SEE THAT NOW THAT A GENERATOR IS INSTALLED AND | | | REQUIRED AND USE IS TO A HIGH-RISE, PLEASE SEE NFPA-20 | | | 6-6.2 AS THE MINIMUM FUEL REQUIRED FOR FIRE PUMP IS | | | 8HRS AT 100%, AND 5% FOR EXPANSION AND 5% FOR SUMP. | | | PLEASE SEE TANK AS SHOWN AND FUEL CALCULATIONS CAN NOT | | | VERIFIED AS NO INFORMATION WAS SUBMITTED. | | | ** PLEASE SEE THE RESPONSE LETTER GIVES SOME | | | INFORMATION HOWEVER ALSO STATES 30GALLONS PER MINUTE | | | FOR USE. | | | PLEASE KNOW THE CALCULATIONS FOR CONSUMPTION NEEDS TO | | | BE SHOWN ON PLANS. | | | PLEASE SEE COMMENTS BELOW AS THE SIZE OF THE FIRE PUMP | | | DOES NOT COORDINATE ON PLANS. PLEASE ALSO BE AWARE THAT | | | THE INFORMATION ON MANUFACTURES SPECS/CUT SHEETS HAS | | | NOT BEEN SUBMITTED TO CONFIRM OR COORDINATE WITH | | | PLANS. | | | | | | 9) NOTE: THIS REMAINS: PLEASE SEE NFPA-20 CHAPTER 6 AND | | | 7 FOR FIRE PUMP, ASTHERE ARE TOO MANY SECTIONS TO BE | | | LISTED FOR ITEMS NEEDED FOR REVIEW. | | | PLEASE SEE THAT BESIDES THE MISSING MANUFACTURES | | | SPECS/CUT SHEETS, PLEASE SEE THE RISER SHEETS SHOWS TWO | | | DIFFERENT SIZES OF FIRE PUMPS, TWO DIFFERENT SIZES OF | | | OVER CURRENT PROTECTION OF MAINS ETC. | | | VERIFICATION OF SEVERAL ITEMS CAN NOT BE DONE AT THIS | | | TIME. (CONDUCTORS, OVER CURRENT PROTECTION, CORRECT | | | GROUNDING (SEE COMMENT BELOW) CONDUIT SIZES, ISOLATION | | | SWITCHES ETC. | | | ** IMPORTANT, SEE COMMENT WITH RESPECT TO THE GENERATOR | | | BEING NOTED AS BEING A *SEPARATELY DERIVED SYSTEM* | | | WHICH WOULD REQUIRE THE FIRE PUMP CONTROLLER ATS TO BE | | | FOUR POLE. | | | | | | 10) NOTE: AS STATED ON THE PREVIOUS REVIEW:PLEASE SEE | | | NFPA-110 CHAPTER 7,7.2.3 FOR MIN ELEVATION REQUIRED | | | FOR ALL EPSS EQUIPMENT INCLUDING GEN. | | | PLEASE PROVIDE MIN LEVELS FOR "SLOSH" ( SEA, LAKE, | | | OVERLAND , SURGES, BY HURRICANES) CHARTS BASED ON A CAT | | | 4 STORM OR THE 100YR ELEVATION ON PLANS. | | | THE RESPONSE MENTIONS, BUILDING LOCATED ABOVE FLOOD | | | LEVEL. PLEASE KNOW HOWEVER THE MINIMUM LEVEL FOR EPSS | | | EQUIPMENT BASED ON THE CHARTS NOTED ABOVE NEEDS TO BE | | | STATED AND SHOWN ON PLANS. PLEASE SEE NO ELEVATIONS ON | | | ELECTRICAL PLANS FOR LIFE SAFETY EQUIPMENT IS BEING | | | SHOWN. (FIRE PUMP ON MEZZANINE LEVEL IS NOT NEEDED) AS | | | THIS IS A GIVEN DUE TO ITS LOCATION. | | | | | | 11) NOTE: PLEASE SEE THE GROUNDING ELECTRODE SHOWN FOR | | | THE FIRE PUMP SERVICE IS TOO SMALL BASED ON 250.66. | | | PLEASE ADJUST. (SHOWN AS #4 ON E-7) | | | | | | 12) NOTE: PLEASE SEE THE SIZE OF THE FIRE PUMP | | | CONTROLLER ON E-7 SHOWN AS 800AMPS AND 500AMPS? PLEASE | | | CORRELATE WITH THE UPDATED SIZE OF THE NEW FIRE PUMP. | | | FBC 104.1.2 FOR COORDINATION. | | | | | | 13) NOTE: PLEASE SEE THE NOTE BELOW THE GENERATOR | | | CLEARLY STATES THE GENERATOR WILL BE A SEPARATELY | | | DERIVED SYSTEM, YET IF THIS IS THE CASE, THE OTHER NOT | | | ON THE GROUNDING ELECTRODE AT GENERATOR STATES ONLY | | | GROUND TO CASE WHICH DOES NOT CONFIRM OR CORRELATE WITH | | | THE SEPARATELY DERIVED NOTE. | | | PLEASE ALSO KNOW IF INDEED THIS IS A SDS, PLEASE ADJUST | | | RISER AS ALL ATS EQUIPMENT WILL NEED TO BE FOUR POLES. | | | 250.20,250.30 ETC | | | | | | 14) NOTE: AS REQUESTED ON PREVIOUS REVIEW: THIS COMMENT | | | WILL REMAIN AS THE INFORMATION WHICH WILL BE SUBMITTED | | | ON GENERATOR WILL CONFIRM AVAILABLE FAULT CURRENT ON | | | THE GENERATOR. THE LEVELS ON THE MANUFACTURE SPECS/CUT | | | SHEETS WILL ALSO BE REVIEWED. | | | PLEASE PROVIDE ALL AIC RATINGS FOR ALL EQUIPMENT, ATS, | | | DISCONNECTS ETC. PLEASE SEE 701.6, NFPA-20 6-3.2.2.4, | | | 110.9, 240.12 ETC. PLEASE SEE NFPA-110 6.5.2 ETC. | | | PLEASE BE SURE ALL EQUIPMENT/MANUFACTURE SPECS/CUT | | | SHEETS SHOWS THIS COORDINATION. | | | | | | 15) NOTE: THIS NOTE REMAINS FROM PREVIOUS REVIEW NOTE | | | #18. | | | PLEASE SEE MISSING A DISCONNECTING MEANS REQUIRED FOR | | | THE FEEDERS COMING FROM THE GENERATOR TO MEET | | | 701.11(B)5. | | | ** PLEASE SEE THAT THE RESPONSE MENTIONS THE GENERATOR | | | MEETS THE EXCEPTION, HOWEVER KNOWN TO THIS OFFICE IS | | | THE REQUIREMENTS FROM ZONING WHICH WILL NEED A | | | WALL/SCREENING AROUND THE UNIT ON ALL FOUR SIDES. THIS | | | WOULD ALSO LOCK THE BREAKER ON THE INSIDE OF THE UNIT | | | WHICH WOULD NOT BE READILY ACCESSIBLE. | | | PLEASE SEE THAT BREAKERS SOMETIMES MAY BE USED, HOWEVER | | | THEY MAY NOT | | | | | | 19) NOTE: AS REQUESTED FROM PREVIOUS REVIEW: PLEASE | | | PROVIDE DETAIL FOR VERTICAL CONDUCTOR SUPPORTS PER | | | 300.19(A). | | | ** RESPONSE LETTER MENTIONS TO SEE DETAIL ON E-7, | | | HOWEVER NO DETAIL COULD BE LOCATED ON THIS SHEET AS | | | REFERENCED. | | | | | | 20) NOTE:THIS NOTE REMAINS FROM PREVIOUS REVIEW NOTE | | | #21. | | | PLEASE PROVIDE ALL MINIMUM AUDIBLE AND VISUAL LEVELS | | | PER FBC 2001 11-4.28, 11-4.28.2 AND MOST IMPORTANT | | | 11-4.28.3(4). ALL AREA AS STATED IN 11-4.28.1 SHALL BE | | | NOTED AND INCLUDED. THIS COMMENT WAS NEVER UNDER | | | ELECTRICAL REVIEW SCOPE ON PREVIOUS REVIEWS UNTIL | | | RECENTLY. | | | ** RESPONSE LETTER MENTIONS TO SEE REVISED NOTES ON | | | FA-5 WHICH WAS LOCATED HOWEVER THE PREVIOUS REVIEW NOTE | | | REQUESTED ALL MINIMUM LEVELS TO BE STATED ON LEGEND FOR | | | THE REQUIRED DEVICES. PLEASE SEE THE DEVICES STILL DO | | | NOT INDICATE THE LEVELS. | | | PLEASE KNOW THAT QUOTING THE CODE SECTIONS IN LIEU OF | | | THE REQUIRED DETAIL FOR CONSTRUCTION AND DESIGN IS NOT | | | ACCEPTABLE AND MUST SHOW DESIGN DETAIL. | | | | | | 21) NOTE:AS REQUESTED ON PREVIOUS REVIEW NOTE #22. | | | PLEASE INCLUDE A NOTE ON ROOF TOP PLANS WHICH WILL | | | STATE THAT "ANY LIGHTNING PROTECTION SYSTEM TO BE | | | INSTALLED SHALL MEET NFPA-780" OR WORDS TO THAT AFFECT. | | | A SYSTEM IS NOT REQUIRED, HOWEVER THE NOTE IS, AS THERE | | | ARE MANY SYSTEMS BEING "PROMOTED AND SOLD" IN THE STATE | | | OF FLORIDA WHICH ARE STRICTLY NOT PERMITTEDAND MANY | | | KNOWN SYSTEMS ARE ACTUALLY A HEALTH AND LIFE SAFETY | | | HAZARD. PLEASE SEE ONLY IF IN NFPA-780. | | | ** PLEASE KNOW THERE ARE SEVERAL ITEMS NOT YET SHOWN, | | | CLARIFIED OR SUBMITTED. AS STATED ON PREVIOUS REVIEW | | | THERE MAY VERY WELL BE NEW COMMENTS ON THE FOLLOWING | | | REVIEW ONCE THE COMPLETED PLANS ARE SUBMITTED. | | | ** RESPONSE LETTER MENTIONS THIS WAS ADDED TO NOTES ON | | | SHEET E-4 HOWEVER THIS WAS NOT LOCATED ON THIS SHEET | | | AND NOTE COULD NOT BE FOUND. | | | PLEASE COMPLETE. | | | | | | AS STATED ON THE PREVIOUS REVIEW: | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-08-24 07:54:55 | 2007-08-24 07:54:55 | | | REVIEW IN PROGRESS | | 2007-08-14 13:41:04 | 1-SET IN ELEC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-10-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-29 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-28 |
Time |
19:23 |
Sent To |
|
|
| Notes |
| 2006-10-29 08:28:03 | ****UNSAT **** | | | | | | ** REVIEW FORE REVISION OF CLARKES HOTEL FROM 5-STORIES | | | TO 8 STORIES. | | | | | | ** PLEASE KNOW THAT AT THIS TIME THERE IS NOT ENOUGH | | | INFORMATION SUBMITTED FOR A COMPLETE REVIEW FOR CODE | | | COMPLIANCE AS THE BUILDING HAS NOW BEEN CLASSIFIED AS A | | | HIGH-RISE. PLEASE SEE ONLY SOME NOTES BELOW ARE NOTED | | | FOR ITEMS NEEDED. | | | | | | 1) NOTE: PLEASE SEE THAT ALL REVISIONS ON PLANS SHALL | | | BE DATED, CLOUDED/TRIANGLE NOTATIONS ACCORDINGLY. | | | PLEASE SEE DATES AND REVISION NUMBERS SHOW A REV #1, | | | HOWEVER THIS HAS BEEN REVISED AT LEAST THREE OR FOUR | | | TIMES. HOW IS THIS FIRST REVISION?? | | | | | | ** PLEASE KNOW AS THIS BUILDING IS COMPLETELY CHANGING | | | IN DESIGNATION; PLEASE PROVIDE A COMPLETE SET OF | | | REVISED ELECTRICAL PLANS AS SUBMITTING FOR A NEW | | | BUILDING. A FULL REVIEW WILL BE BASED ON THE SUBMITTED | | | PLANS. | | | | | | 2) NOTE: PLEASE LIST ALL OF THE FOLLOWING CODES AT A | | | MINIMUM ON PLANS. | | | 2002 NFPA-72(DONE), 1999 NFPA-20, 2003 NFPA-101, 2002 | | | NFPA-110. | | | IT IS KNOW THAT THIS PROJECT CAME IN UNDER THE 2001 | | | FBC. | | | | | | 3) NOTE: PLEASE SUBMIT ALL THE MANUFACTURE SPECS/CUT | | | SHEETS FOR ALL OF THE FOLLOWING. PLEASE SUBMIT FOR; | | | FIRE PUMP, FIRE PUMP CONTROLLER, GENERATOR, FUEL TANK. | | | (SEENOTES BELOW), ATS EQUIPMENT (SEENOTESBELOW). | | | 110.3, 90.7 | | | | | | | | | 4) NOTE: PLEASE SUBMIT COMPLETE PHOTO-METRICS FOR ALL | | | EGRESS PATHS. (ALL CORRIDORS AND STAIR TOWERS) PLEASE | | | SEE LS-1017.8.1.3, 7.9.2.2 10FT CANDLE MIN FOR STAIRS | | | UNDER NORMAL AND 1FT CANDLE UNDER EM. | | | | | | ** PLEASE ALSO BE AWARE OF ZONING COMMENTS AS | | | PHOTO-METRICS WILL ALSO BE REQUIRED FOR FUTURE PARKING | | | GARAGE. | | | | | | 5) NOTE: PLEASE SEE ZONING COMMENTS, PLEASE SEE IF A | | | GARAGE IS NOW REQUIRED, THIS WILL COMPLETELY CHANGE | | | ELECTRICAL SERVICE AND ELECTRICAL SHEETS SUBMITTED. | | | | | | 6) NOTE: PLEASE SEE PREVIOUS PLANS WHICH WERE RED-LINED | | | FOR CIRCUITING OF ELEVATOR MACHINE ROOMS PER 620.23, | | | 620.24 AND ASSOCIATED EQUIPMENT. THIS HAS NOT BEEN | | | CORRECTED ON PLANS TO DATE. | | | | | | 7) NOTE: PLEASE SEE ALL FIXTURE SCHEDULE AND TYPE | | | INFORMATION WHICH WAS ON PREVIOUS PLANS HAS BEEN | | | REMOVED FOR EM FIXTURES? | | | PLEASE SEE ALL OF THE FOLLOWING IN ORDER TO REVIEW FOR | | | CODE COMPLIANCE SHALL BE PLACED BACK ON PLANS. | | | LS 101 | | | | | | 8) NOTE: PLEASE SEE THAT NOW THAT A GENERATOR IS | | | INSTALLED AND REQUIRED AND USE IS TO A HIGH-RISE, | | | PLEASE SEE NFPA-20 6-6.2 AS THE MINIMUM FUEL REQUIRED | | | FOR FIRE PUMP IS 8HRS AT 100%, AND 5% FOR EXPANSION AND | | | 5% FOR SUMP. | | | PLEASE SEE TANK AS SHOWN AND FUEL CALCULATIONS CAN NOT | | | VERIFIED AS NO INFORMATION WAS SUBMITTED. | | | | | | 9) NOTE: PLEASE SEE NFPA-20 CHAPTER 6 AND 7 FOR FIRE | | | PUMP, ASTHERE ARE TOO MANY SECTIONS TO BE LISTED FOR | | | ITEMS NEEDED FOR REVIEW. | | | | | | 10) NOTE: PLEASE SEE NFPA-110 CHAPTER 7,7.2.3 FOR MIN | | | ELEVATION REQUIRED FOR ALL EPSS EQUIPMENT INCLUDING | | | GEN. | | | PLEASE PROVIDE MIN LEVELS FOR "SLOSH" ( SEA, LAKE, | | | OVERLAND , SURGES, BY HURRICANES) CHARTS BASED ON A CAT | | | 4 STORM OR THE 100YR ELEVATION ON PLANS. | | | | | | 11) NOTE: PLEASE SEE POOL AREA PHOTO-METRICS ARE TO BE | | | REVIEWED AND STAMPED BY THE PALM BEACH COUNTY HEALTH | | | DEPARTMENT IF ANY SWIMMING WILL TAKE PLACE OR PERMITTED | | | FROM DUSK TO DAWN. PLEASE KNOW THAT THE POOL WILL ALSO | | | BE REQUIRED UNDER A SEPARATE PERMIT. | | | IF NO SWIMMING , PLEASE PROVIDE NOTES ON THESE PLANS AT | | | THIS TIOME, EVEN THOUGH THE POOL WILL BE UNDER A | | | SEPARATE PERMIT. | | | | | | 12) NOTE: PLEASE SEE SOME SHEETS ARE MISSING TITLE | | | BLOCK INFORMATION AS REQUIRED FOR ENGINEER. PLEASE SEE | | | MISSING THE PRINTED NAME, PRINTED LICENSE # AND MISSING | | | THE DATE WHEN PLANS WERE SIGNED AND SEALED. | | | PLEASE SEE FS 471.025, FAC 61G15-23.002 | | | | | | 13) NOTE: PLEASE CORRELATE AND LABEL ALL MAINS ON | | | SCHEDULES, RISER AND MAIN ELECTRICAL ROOM(S). PLEASE | | | SEE SCHEDULES DO NOT CORRELATE WITH RISER, ETC. 230.2E | | | ETC, | | | | | | 14) NOTE: PLEASE PROVIDE ALL AIC RATINGS FOR ALL | | | EQUIPMENT, ATS, DISCONNECTS ETC. PLEASE SEE 701.6, | | | NFPA-20 6-3.2.2.4, 110.9, 240.12 ETC. PLEASE SEE | | | NFPA-110 6.5.2 ETC. | | | PLEASE BE SURE ALL EQUIPMENT/MANUFACTURE SPECS/CUT | | | SHEETS SHOWS THIS COORDINATION. | | | | | | 15) NOTE: PLEASE SEE NEC 11.26 FOR MAXIMUM DISTANCE A | | | GUTTER OR ANY OTHER EQUIPMENT SHALL PROTRUDE IN FRONT | | | OF EQUIPMENT. (6") PLEASE SEE RISER AND PROVIDE A SIDE | | | ELEVATION TO INDICATE IF EQUIPMENT WILL BE MOUNTED OUT | | | FROM THE WALL. | | | PLEASE ALSO SEE THE FOLLOWING COMMENT FOR SIZING GUTTER | | | TO MAIN 2 AND 3 ON RISER. (SHOWN AS DIFFERENT MAINS ON | | | OTHER SECTIONS OF PLANS SEE NOTE #13). | | | | | | 16) NOTE: PLEASE SEE 240.4C, AS THE SEC'S FROM FPL TO | | | GUTTER SHALL BE RATED AT 1200A?S OR ABOVE. | | | 90.4. | | | | | | 17) NOTE: PLEASE ALSO VERIFY THE SIZE OF THE GUTTER FOR | | | MAINS #2 AND #3 ON RISER. PLEASE SEE 366. | | | | | | 18) NOTE: PLEASE SEE MISSING A DISCONNECTING MEANS | | | REQUIRED FOR THE FEEDERS COMING FROM THE GENERATOR TO | | | MEET 701.11(B)5. | | | | | | 19) NOTE: PLEASE PROVIDE DETAIL FOR VERTICAL CONDUCTOR | | | SUPPORTS PER 300.19(A). | | | | | | 20) NOTE: PLEASE SEE NFPA-110 FOR ATS EPSS EQUIPMENT | | | SECTION: 7.2.2.1TRANSFER SWITCHES SHALL BE PERMITTED | | | TO BE INSTALLED IN THE NORMAL ELECTRICAL SERVICE ROOM | | | WHERE TWICE THE CLEARANCE REQUIRED BY ARTICLE 110.26(A) | | | OF NFPA 70, NATIONAL ELECTRICAL CODE, EXISTS BETWEEN | | | EQUIPMENT ENCLOSURES. | | | THIS DOES NOT APPEAR TO BE MET AT THIS TIME. | | | | | | 21) NOTE: PLEASE PROVIDE ALL MINIMUM AUDIBLE AND VISUAL | | | LEVELS PER FBC 2001 11-4.28, 11-4.28.2 AND MOST | | | IMPORTANT 11-4.28.3(4). ALL AREA AS STATED IN 11-4.28.1 | | | SHALL BE NOTED AND INLCUDED. THIS COMMENT WAS NEVER | | | UNDER ELECTRICAL REVIEW SCOPE ON PREVIOUS REVIEWS UNTIL | | | RECENTLY. | | | | | | 22) NOTE: PLEASE INCLUDE A NOTE ON ROOF TOP PLANS WHICH | | | WILL STATE THAT "ANY LIGHTNING PROTECTION SYSTEM TO BE | | | INSTALLED SHALL MEET NFPA-780" OR WORDS TO THAT AFFECT. | | | A SYSTEM IS NOT REQUIRED, HOWEVER THE NOTE IS,AS THERE | | | ARE MANY SYSTEMS BEING "PROMOTED AND SOLD" IN THE STATE | | | OF FLORIDA WHICH ARE STRICTLY NOT PERMITTEDAND MANY | | | KNOWN SYSTEMS ARE ACTUALLY A HEALTH AND LIFE SAFETY | | | HAZARD. PLEASE SEE ONLY IF IN NFPA-780. | | | | | | ** PLEASE KNOW AS THERE IS INFORMATION NOT YET | | | SUBMITTED. PLEASE KNOW THERE MAY BE FUTURE COMMENTS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | 2006-10-29 06:55:15 | REVIEW IN PROGRESS | | 2006-10-28 19:23:25 | ONE ROLL IN ELECTRICAL FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-20 |
Time |
07:21 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2005-07-19 |
Time |
12:28 |
Sent To |
|
|
| Notes |
| 2005-07-20 00:00:00 | PLANS OK, STAMPED THREE SETS OF | | | ELECTRICAL PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-04-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-19 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-04-18 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2005-04-19 00:00:00 | ***** UNSAT ****** | | | | | | 1)NOTE: PLEASE SEE E-1 ELECTRICAL ROOM | | | LAYOUT WHICH DOES NOT INLCUDE ANY | | | ELECTRICAL EQUIPMENT ,HOWEVER THIS ROOM | | | SHOWS A NEW EF-7? | | | PLEASE CORRELATE WITH "BLOW-UP" OF | | | ELECTRICAL RM ON E-7 | | | | | | 2)NOTE: PLEASE SEE MAINS FOR ELEVATOR'S | | | SHALL BE LABELED MAIN 4 OF 5 AND 5 OF 5. | | | 230.70,71 ETC. | | | | | | 3)NOTE: PLEASE SEE 620.23 ETC FOR | | | CIRCUITING. | | | | | | 4)NOTE: PLEASE SEE AN EQUIPMENT | | | GROUNDING CONDUCTOR IS INSTALLED FROM | | | FPL TO FIRST MEANS OF DISCONNECT FOR | | | FIRE PUMP AND FIRE PUMP CONTROLLER. | | | PLEASE SEE 250.6,250.24, EQUIPMENT | | | GROUNDING IS ONLY INSTALLED AFTER THE | | | FIRST MEANS OF DISCONNECT. | | | | | | PLEASE KNOW, IF PLANS DO NOT COME BACK | | | WITH ANY COMMENTS FROM ANY OF THE OTHER | | | REVIEWER(S) THIS MAY BE DONE AS A | | | PROVISO FOR NEW REVISED SHEETS TO BE | | | PROVIDED BEFORE ANY SLAB INSPECTION. | | | | | | | | | PLEASE BE SURE TO REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO THREE COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | 2005-04-18 00:00:00 | ONE ROLL IN ELECTRICAL FOR REVIEW. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
7 |
Status |
P |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-07-11 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-07-11 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
6 |
Status |
F |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-07-03 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-07-03 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2008-07-03 11:55:02 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | | | | 1.PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | | | | 2. HOW DO YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | | SITE? PLEASE SHOW ON THE DRAWINGS.PLEASE SHOW ALL | | | STORM WATER PIPES AROUND YOUR SITE SO, WE CANSEE THE | | | LAYOUT OF STORM WATER PIPES FROM ALL OTHER STORM WATER | | | PIPES. PLEASE SHOW LENGTH OF EXFILTRATION TRENCHES ON | | | THE DRAWING PER YOUR WATER QUALITY CALS SUBMITTED TO | | | US. YOU NEED TO SHOW THE DETAILS OF EX-FILTRATION | | | TRENCH ALSO ON THE DRAWING. | | | | | | 3.PLEASE SHOW ALL CATCH BASINSIN YOUR SITE & NEAREST, | | | AROUND YOUR SITE FOR STORM WATER DRAIN. PLEASE SHOW ON | | | DRAWINGS TURBIDITY DETAILS & TURBIDITY AROUND THE ALL | | | CATCH BASINS & ALL OTHER WATER AREAS FOR THE POLLUTION | | | PREVENTION. ETC., HEIGHT OF THE TURBIDITYSHOULD BE | | | HIGH ENOUGH PER FDEP. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
5 |
Status |
F |
Date |
2008-05-01 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-05-01 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-05-01 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2008-05-01 09:28:31 | ****FAILED**** | | | | | | | | | PLEASE RESPOND THE COMMENTS LAST TIME WE MADE ON | | | 8/28/07, REV NO: 3 | | | | | | YOURCOMMENT NOTEON PLAN/PERMIT REVISION & | | | SUBMITTALS FORM SUBMITTED ON APRIL 15, 08 SAYS THAT | | | ENGINEERING PLANS WILL BE SUBMITTED LATER. AS OF NOW WE | | | DO NOT HAVE THEM. | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
F |
Date |
2008-01-15 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-01-15 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-01-15 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2008-01-15 11:00:45 | ****FAILED**** | | | | | | | | | PLEASE RESPOND THE COMMENTS LAST TIME WE MADE ON | | | 8/28/07, REV NO: 3 | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-08-28 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-08-28 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2007-08-28 15:52:55 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | PERMIT # 03121642 IS EXPIRED.MR. M. AMINI WROTE IN | | | REV 1, OF # 05031185 THAT PLANS WERE REVIEWED IN # | | | 03121642.THE PERMIT # 03121642 WAS 5 STORY, NEW | | | PERMIT IS 8STORY BUILDING. | | | SINCE OLD PERMIT IS EXPIRED, WE NEED TO REVIEW THIS | | | PERMIT PER CURRENT REQUIREMENTS. | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | 3. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION MUST MEET FLOOD ZONE AREA, & 5,10, | | | 25, 100 YEAR FLOOD CRITERIATO DETERMINE THE FIRST | | | FLOOR ELEVATION, PLEASE SHOW IN YOUR STORM WATER CALS. | | | 4. PLEASE SHOW ON DRAWINGTHE SITE AREA, YOU ARE | | | DEVELOPING FOR THIS PROJECT . PLEASE ALSO SHOW TOTAL | | | PERVIOUS,& IMPERVIOUS AREA FOR THIS PROJECT, | | | LAKE,SIDEWALK, PARKING,BUILDING AREA ETC. MAKE SURE | | | THESE AREAS SHOWN ON DRAWINGS MUST MATCH WITH AND USED | | | IN STORM WATER QUALITY CALCULATIONS. | | | 5. HOW DO YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | | SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES | | | AROUND YOUR SITE SO, WE CANSEE THE LAYOUT OF STORM | | | WATER PIPES FROM ALL OTHER STORM WATER PIPES. PLEASE | | | SHOW DETAIL OF THE CONTROL STRUCTURESWITH | | | ELEVATIONS, NOTCHES, BLEEDING ELEVATION, ETC ON | | | DRAWINGS, CALCULATION FOR EXFILTRATION TRENCHES, | | | PLEASE SHOW DRY DETENTION/WET DETENTION AREAS IN STORM | | | WATER CALS. | | | 6. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | | YOUR SITE FOR STORM WATER DRAIN. | | | 7. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, &STORM | | | WATER QUALITY CALCULATIONS, | | | 9. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION | | | DETAILS,CLOTHES USED FOR SILT ETC., PLANS SHOWING SILT | | | FENCE AROUND THE SITE & CATCH BASINS.HEIGHT OF FENCE | | | SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST & | | | PARTICLES. | | | 10. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED | | | 11.PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR | | | SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP | | | PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FROM | | | 1000, 45 STREET FOR ALL THESE CITY STANDARDS NOTES. | | | PHONE# 494-1040 | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-11-03 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-11-03 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2006-11-03 14:35:00 | PLEASE TELL US WHAT DID YOU CHANGE THIS TIME FROM LAST | | | APPROVAL IN YOUR DRAWINGS.CHANGES, ANYTHING FOR | | | STORMWATER DRAINAGE, EXFILTRATION TRENCH, CONTROL | | | STRUCTURES, DUMPSTER ENSLOSURE,SIDEWALK,PARKINGS,ADA, | | | HANDICAP, PERVIOUS , IMPERVIOUS AREA.DID YOU HAVE | | | ANYTHINGS CHANGE, PLEASE REPLY IN WRITING WHAT YOU | | | CHANGED OR NO CHANGE FROM WHAT DATE ETC., | | | | | | THANKS, RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2005-05-31 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-05-31 |
Time |
10:43 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-05-31 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2005-05-31 00:00:00 | PASSED: | | | | | | 1. CIVIL PLANS WERE REVIEWED AND | | | APPROVED UNDER PERMIT # 03121642 WHICH | | | WAS EXPIRED.NEW CIVIL PLANS AS | | | SUBMITTED SHOW NO CHANGES. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
8 |
Status |
P |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-07-11 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-11 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
F |
Date |
2008-07-09 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-07-09 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-09 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2008-07-09 14:40:13 | ***DENIED*** | | | | | | 1) PLEASE ADDRESS COMMENTS FROM LAST FIRE REVIEW. SHEET | | | C-8 HAS BEEN IDENTIFIED AS REVISED FOR FIRE REVIEW. | | | PLEASE ADVISE AS ALL CIVIL SHEETS APPEAR TO BE NEW. | | | WHAT HAS BEEN REVISED ON SHEET C-8 THAT REQUIRES A FIRE | | | REVIEW? NOTHING WAS LOCATED RELATED TO FIRE PROTECTION | | | EQUIPMENT. YOUR RESPONSE INDICATES EQUIPMENT TO BE | | | FOUND ON FA-01 AND FA-02. THE FIRE REVIEW COMMENT | | | APPLIES TO MONITORING, NOT SUPERVISORY EQUIPMENT FOR | | | THE DOUBLE DETECTOR CHECK ASSEMBLY. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
F |
Date |
2008-05-23 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-05-23 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-05-23 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2008-05-24 19:33:59 | *****DENIED***** | | | | | | THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE | | | PLAN REVIEWS STILL NEED TO BE ADDRESSED: | | | | | | | | | 03.PLEASE PROVIDE A CLEAR DETAIL REGARDING | | | SUPERVISING EQUIPMENT ON DOUBLE DETECTOR CHECK ASSEMBLY | | | ON SHEET C-8.YOUR RESPONSE INDICATED THAT DETAILS | | | WERE NOW SHOWN ON SHEET C-8, HOWEVER NO CIVIL DRAWINGS | | | WERE FOUND | | | | | | 11.SMOKE/PRESSURIZATION AND VENTILATION INDICATES | | | THAT SYSTEM IS SIZED FOR MAXIMUM OF FIVE STORIES. | | | PLEASE ADVISE NOW THAT THE PROJECT IS EIGHT STORIES. | | | DISPLAY/SHOW THAT THE SYSTEM IS CAPABLE OF ADEQUATE | | | FUNCTIONING FOR THE EIGHT STORY BUILDING. | | | | | | 12.THE DRAWING ON SHEET AC-8 (REGARDING THE SMOKE | | | CONTROL PANEL) APPEARS TO NEED MORE DETAIL.PLEASE | | | CALL/CONTACT THE BUREAU OF FIRE PREVENTION AT | | | 561-804-4724 TO PROVIDE A DRAWING FOR REVIEW BY THIS | | | OFFICE.PROVIDE DOCUMENTATION THAT THIS ARRANGEMENT | | | WAS APPROVED BY BATTALION CHIEF MIKE CARSILLO ON | | | 03/12/08 | | | | | | 13.FIRE ALARM AND FIRE SPRINKLER PLANS WILL NEED TO | | | BE UPDATED ILLUSTRATING NEW BATTERY CALCULATIONS AND | | | SPRINKLER MODIFICATION FOR NEW PROPOSED FLOORS AT TIME | | | OF PERMIT APPLICATION FOR REFERENCED SYSTEMS.PROVIDE | | | DOCUMENTATION THAT THIS ARRANGEMENT WAS APPROVED BY | | | BATTALION CHIEF MIKE CARSILLO ON 03/12/08 | | | | | | | | | | | | PLEASE PROVIDE A RESPONSE LETTER TO FIRE PLAN REVIEW | | | ADDRESSING THESE COMMENTS.IT WOULD BE HELPFUL TO | | | INDICATE WHERE ON THE PLANS THE CHANGE IS ADDRESSED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
F |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-03-04 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-03-04 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2008-03-04 13:16:29 | ***DENIED*** | | | | | | PLEASE NOTE THAT SOME OF THE COMMENTS HAVE BEEN | | | ADDRESSED. A RESPONSE LETTER WAS SUBMITTED REFERRING | | | REVIEWERS TO THE MEP ENGINEER. I WAS UNABLE TO LOCATE | | | THE LETTER SPECIFIC TO THE FIRE REVIEW COMMENTS. | | | | | | 1) OK | | | | | | 2) RESPONSE REFERS TO ENGINEER'S RESPONSE. | | | | | | 3) RESPONSE REFERS TO CIVIL ENGINEER'S RESPONSE. | | | | | | 4) RESPONSE REFERS TO ENGINEER'S RESPONSE. | | | | | | 5) OK | | | | | | 6) OK | | | | | | 7) OK | | | | | | 8) OK | | | | | | 9) RESPONSE REFERS TO ENGINEER'S RESPONSE. | | | | | | 10) SMOKE DETECTORS ARE STILL NOT SHOWN IN CORRIDOR | | | 142. | | | | | | 11) RESPONSE REFERS TO ENGINEER'S RESPONSE. | | | | | | 12) RESPONSE REFERS TO ENGINEER'S RESPONSE. | | | | | | 13) RESPONSE REFERS TO ENGINEER'S RESPONSE. | | | | | | 14) RESPONSE REFERS TO ENGINEER'S RESPONSE. | | | | | | I UNDERSTAND THAT SOME COMMENTS MAY BE THE | | | RESPONSIBILTY OF DIFFERENT INDIVIDUALS, BUT IT WOULD | | | HELP EXPEDITE THIS PROCESS IF RESPONSES WERE | | | CONSOLIDATED AND PROVIDED WITH THE SUBMITTAL AT ONE | | | TIME. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2007-09-13 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-09-13 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-09-13 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2007-09-13 14:16:45 | ***DENIED*** | | | | | | PLEASE NOTE THAT THIS PROJECT HAS CHANGED FROM FIVE (5) | | | STORIES TO EIGHT (8) STORIES, AND SHALL MEET ALL | | | REQUIREMENTS OF NFPA 101, CHAPTER 11 FOR HIGHRISE | | | BUILDINGS. | | | | | | 1) HIGHRISE BUILDINGS SHALL BE PROVIDED WITH AS MINIMUM | | | OF TWO (2) FIRE DEPARTMENT CONNECTIONS WITH KNOX | | | LOCKING CAPS. PLANS DO SHOW (2) CONNECTIONS. | | | | | | 2) FIRE ALARM SYSTEM TO MEET SURVIVABILITY | | | REQUIREMENTS. | | | | | | 3) PLEASE PROVIDE A CLEAR DETAIL REGARDING SUPERVISING | | | EQUIPMENT ON DOUBLE DETECTOR CHECK ASSEMBLY. SHEET C-8 | | | | | | 4) PLANS CALL OUT KNOX BOXES WITH LOCKING CAPS. PLEASE | | | CLARIFY AND CORRECT AS LOCKING CAPS WOULD BE REQUIRED | | | FOR FIRE DEPARTMENT CONNECTIONS. | | | | | | 5) PLEASE ADD INFORMATION REGARDING ACCESS OR NO ACCESS | | | TO ROOF ON STAIRWELL TACTILE SIGNAGE. | | | | | | 6) LIFE SAFETY SHEETS ILLUSTRATE THE FIRE RATING OF | | | SOME DOORS. PLEASE INDICATE THE FIRE RATING OF THE DOOR | | | TO THE FIRE COMMAND ROOM. | | | | | | 7) PLEASE PROVIDE FIRE RATING OF DOORS TO THE PUMP | | | ROOM, GENERATOR ROOM AND ELECTRICAL ROOM. SHEET A-124 | | | | | | 8) EXIT SIGNS SHALL NOT SPAN A DISTANCE GREATER THAN | | | 100'. | | | | | | 9) FIRE COMMAND ROOM STILL DOES NOT SHOW A SMOKE | | | DETECTOR. SHEET FA-1 | | | | | | 10) SMOKE DETECTORS ARE NOT SHOWN IN CORRIDOR 142. | | | PLEASE ADVISE IF THAT AREA IS PART OF THIS SCOPE OF | | | WORK. | | | | | | 11) SMOKE/PRESSURIZATION AND VENTILATION INDICATES THAT | | | SYSTEM IS SIZED FOR MAX. OF (5) STORIES. PLEASE ADVISE | | | NOW THAT PROJECT IS (8) STORIES. | | | | | | 12) PLEASE CONTACT THE BUREAU OF FIRE PREVENTION | | | REGARDING THE SMOKE MANAGEMENT PANEL. THE DRAWING ON | | | SHEET AC-8 APPEARS TO NEED MORE DETAIL. PLEASE CALL | | | (561) 804-4724 TO PROVIDE A DRAWING FOR REVIEW BY THIS | | | OFFICE. | | | | | | 13) FIRE ALARM AND FIRE SPRINKLER PLANS WILL NEED TO BE | | | UPDATED ILLUSTRATING NEW BATTERY CALCULATIONS AND | | | SPRINKLER MODIFICATION FOR NEW PROPOSED FLOORS AT TIME | | | OF PERMIT APPLICATION FOR REFERENCED SYSTEMS. | | | | | | 14) KNOX BOX AND LOCKING CAP APPLICATIONS MAY BE | | | OBTAINED AT THE BUREAU OF FIRE PREVENTION. (561) | | | 804-4724 | | | | | | PLEASE PROVIDE A RESPONSE LETTER TO FIRE PLAN REVIEW | | | ADDRESSING THESE COMMENTS. IT WOULD BE HELPFUL TO | | | INDICATE WHERE ON THE PLANS THE CHANGE IS ADDRESSED. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-10-31 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-10-31 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2006-10-31 14:27:34 | ***DENIED*** | | | | | | 1) FIRE SPRINKLER COVERAGE AND SUITE NUMBER APPEAR TO | | | BE MISSING IN AREA OFF COURTYARD 147. SHT FP-1 | | | | | | 2) SOME BATHROOMS ARE SPRINKLERED AND SOME ARE NOT. | | | PLEASE CLARIFY IF THIS IS BASED ON SQUARE FOOTAGE | | | DIFFERENCES OR JUST AN OVERSIGHT. | | | | | | 3) A SMOKE DETECTOR IS REQUIRED IN FIRE COMMAND ROOM IN | | | THE AREA OF THE FIRE ALARM CONTROL PANEL. | | | | | | 4) SMOKE MANAGEMENT PANEL SHALL PROVIDE A GRAPHIC | | | REPRESENTATION OF THE BUILDING. HOA SWITCHES WITH NO | | | OVERLAY OF THE BUILDING WILL NOT BE ACCEPTABLE. | | | | | | 5) FIRE AND SMOKE DAMPERS SHALL BE TESTED FOR CLOSURE | | | PRIOR TO FINAL INSPECTION. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW (561) 805-6722 OR (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-16 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-16 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2005-08-16 00:00:00 | ******APPROVED****** | | | | | | TEMPORARY STANDPIPE SYSTEM IS REQUIRED | | | WHEN BUILDING REACHES 3 STORIES OR 30' | | | IN HEIGHT. | | | | | | FIRE ALARM SYSTEM SHALL BE UL CERTIFIED | | | FOR CENTRAL STATION SERVICE, AND THE | | | CERTIFICATE OR COPY OF THE CERTIFICATE | | | WILL BE REQUIRED BEFORE FINAL FIRE ALARM | | | INSPECTION APPROVAL. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-04-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-04-21 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-04-21 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2005-04-21 00:00:00 | 1) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM SYSTEMS. | | | | | | 2) LOCK CAPS ARE REQUIRED ON FIRE | | | DEPARTMENT CONNECTIONS. | | | | | | 3) FDC LOCATIONS ARE DIFFERENT ON SHEETS | | | SFP-1 AND FP-1. PLEASE INDICATE THE | | | LOCATIONS. | | | | | | 4) PLEASE INDICATE THE PRESCRIPTIVE CODE | | | REQUIREMENTS FOR ALL HANDRAILS AND | | | GUARDRAILS. | | | | | | 5) PLANS DON'T SHOW ANY AUTOMATIC FIRE | | | DETECTION DEVICES IN THE ELEVATOR | | | HOISTWAYS. | | | | | | 6) EMERGENCY LIGHTING IS REQUIRED IN THE | | | FIRE PUMP ROOM. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 OR 805-6722 |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
3 |
Status |
P |
Date |
2008-07-01 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-07-01 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-07-01 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
2 |
Status |
F |
Date |
2008-05-27 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-27 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-27 |
Time |
11:11 |
Sent To |
PC |
|
| Notes |
| 2008-05-27 11:17:46 | SEE PREVIOUS REVIEW COMMENTS DATED 3/4/08. NONE OF THE | | | REQUESTED INFORMATION COULD BE FOUND ON THE PLANS | | | REGARDING THE SIZE OF THE TANK, VENTING OF THE TANK, | | | VENTILATION AND EXHAUST FOR THE GENERATOR. PLEASE | | | PROVIDE ALL RELEVANT INFORMATION SHOWING ALL COMPONENTS | | | OF THE GENERATOR INSTALLATION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
1 |
Status |
F |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-03-04 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-03-04 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2008-03-04 17:28:17 | PLANS SHOW NEW STANDBY GENERATOR. PROVIDE ALL RELATED | | | DOCUMENTATION RELATED TO THE GENERATOR AND GENERATOR | | | ROOM INCLUDING: | | | | | | FUEL TANK | | | FUEL PIPING | | | VENTING | | | VENTILATION OF GENERATOR ROOM | | | LOCATION OF GENERATOR EXHAUST PIPING AND DISCHARGE | | | | | | NOTE: TANKS >550 GALLONS SHALL BE SUBMITTED AND | | | APPROVED BY PALM BEACH COUNTY DEPARTMENT OF | | | ENVIRONMENTAL RESOURCE MANAGEMENT. FOR MORE INFORMATION | | | PLEASE VISIT: | | | HTTP://WWW.PBCGOV.COM/ERM/PERMITTING/PETROLEUM-STORAGE- | | | TANK-COMPLIANCE/ | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-04-22 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-04-22 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2008-04-22 14:55:42 | REVISION OK SHT P-9 GAS RISER & MANUF. SHEETS FOR | | | HEATERS |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-08-27 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-08-27 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2007-08-27 11:30:12 | SEE COMMENTS FROM REVIEW STOP #7 PLUMBING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-09 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-09 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2008-06-09 08:44:55 | TO "COMM" BD#21/PLANS ON RACK/7 ROLLS AND BINDERS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-15 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-15 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2008-04-15 11:15:35 | TO "COMM" BD#6--PLANS ON RACK/6 ROLLS AND PAPERWORK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-01-11 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2008-01-11 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2008-01-11 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2008-01-11 17:36:25 | TO COMM BOARD # 41 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-03 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-03 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2007-07-17 14:54:55 | TO "COMM" BD#20/ PLANS ON RACK--5 ROLLS | | 2007-07-11 16:14:32 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-23 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-23 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2007-04-30 09:09:34 | TO "COMM" BD#54/PLANS ON RACK 4 ROLLS | | 2007-04-23 15:29:50 | WAITING FOR "COMM' BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-08-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-31 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-31 |
Time |
16:01 |
Sent To |
B |
|
| Notes |
| 2006-08-31 00:00:00 | TO "RBROWN" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-25 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-25 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2006-08-25 00:00:00 | TO "COMM" BD#37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-07-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-25 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-25 |
Time |
11:29 |
Sent To |
B |
|
| Notes |
| 2006-07-25 00:00:00 | TO "RBROWN" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-10 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-10 |
Time |
14:32 |
Sent To |
B |
|
| Notes |
| 2006-07-10 00:00:00 | TO "RBROWN" DESK/FOR STAMPING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-22 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-22 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2005-07-25 00:00:00 | TO "COMM" BD#2 | | 2005-07-22 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-08 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-08 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2005-07-08 00:00:00 | TO "COMM" BD #13/ PLANS ON RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-02 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-03-23 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2005-03-23 00:00:00 | TO "COMM" BD#48/PLANS ON "COMM" RACK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2008-07-01 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-07-01 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-07-01 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-03-04 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-03-04 |
Time |
15:28 |
Sent To |
B |
|
| Notes |
| 2008-03-04 17:22:34 | MECH REVIEW COMMENTS ADDRESSED. PLEASE SEE FUEL REVIEW | | | STOP FOR REQUIREMENTS RELATED THE THE GENERATOR FUEL | | | STORAGE SYSTEM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2007-08-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-08-05 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-08-05 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2007-08-05 12:33:49 | ---------------DENIED------------------ | | | | | | 2ND REVIEW OF REVISIONS. | | | | | | FBC 2001 CODE FAMILY. | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS FOR THE PURPOSE OF | | | CONTINUITY. | | | | | | 1. OK | | | | | | 2. THE 4 INCH ROUND DRYER DUCT IS PENETRATING A RATED | | | WALL INTO SUITE 210. HOW WILL THIS DUCT PENETRATION BE | | | PROTECTED? ACCORDING TO FINISH SCHEDULE ON A-602, THE | | | LAUNDRY ROOM HAS NO CEILING OTHER THAN THE EXPOSED | | | CONCRETE FROM THE DECK ABOVE. IT DOES NOT MEET | | | EXCEPTION (3)(4) UNDER FBC,M 607.1.3. SHOW HOW THE FIRE | | | RESISTANCE RATING OF THE WALL IS TO BE MAINTAINED PER | | | FBC,M 504.2. | | | | | | 3. PROTECTION OF SHAFT AT BOTTOM IS NOW SHOWN ON CSR-1, | | | BUT NONE IS SHOWN ON SER-1. PLEASE CORRECT. | | | | | | 4. OK | | | | | | 5. OK, EXCEPT FOR THE ISSUE AS STATED IN COMMENT #3. | | | | | | 6. THE DISTANCE REQUIRED FOR SEPARATION OF INTAKE | | | OPENINGS FROM SOURCES OF CONTAMINATION IS TO BE | | | MEASURED HORIZONTALLY. NO PROVISIONS IS MADE IN THE | | | CODE FOR INTAKE OPENINGS TO BE DIRECTLY ABOVE SOURCES | | | OF CONTAMINATION GIVEN A CERTAIN ELEVATION DIFFERENCE. | | | EXAMPLE: WHAT IF A LARGE TRUCK WITH VERTICAL EXHAUST | | | PIPES WAS PARKED IN THE ALLEY UNDER THE INTAKE | | | OPENING? | | | | | | 7.PROVIDE DETAIL IN ACCORDANCE WITH THE FIRE WRAP | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS SHOWING | | | WRAPPED DUCT PENETRATION OF THE RATED ENCLOSURE AND HOW | | | THE FIRE WRAP IS TO TERMINATE AT THIS LOCATION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-05-31 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-05-31 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-05-31 |
Time |
07:51 |
Sent To |
PC |
|
| Notes |
| 2007-05-31 08:53:06 | ----------------DENIED------------------- | | | | | | MECHANICAL REVIEW NOT COMPLETED. THE 3 SETS OF PLANS | | | SUBMITTED FOR REVISION DO NOT MATCH EACH OTHER. TWO OF | | | THE SETS CONTAIN PREVIOUSLY REVIEWED AND STAMPED PLANS, | | | WHILE ONE SET IS ALL NEW SHEETS. THE TWO PREVIOUSLY | | | STAMPED SETS CONTAIN PAGES WHICH STILL REFLECT THE 5 | | | STORY DESIGN OF THE BUILDING, WHILE THE ONE NEW SET | | | SHOWS THE NEW 8 STORY DESIGN. EXAMPLE: PG A-201. PLEASE | | | RESUBMIT 3 SETS OF REVISED PAGES ONLY, WITH ONE SET OF | | | OLD/VOIDED SHEETS FROM PREVIOUS REVIEW FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS. | | | | | | ONCE THE REVISED PAGES ARE REVIEWED AND STAMPED, WE | | | WILL RETAIN ONE SET AND INCORPORATE THEM INTO OUR COPY | | | OF THE PERMIT SET AND YOU MAY DO THE SAME WITH YOUR TWO | | | COPIES OF THE PERMIT SET. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2006-10-26 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2006-10-17 |
Time |
18:10 |
Sent To |
|
|
| Notes |
| 2006-10-26 18:03:48 | --------------DENIED--------------- | | | | | | REVIEWED UNDER FBC 2001 | | | | | | 1. PG AC-7 TER 1,2,3 BATH FAN SUB DUCTS DO NOT MEET | | | EXCEPTION #2 UNDER FBC,M 607.1.3. THE AIR IN THE RISER | | | MUST BE TRAVELING UPWARD IN ORDER TO CLAIM THIS | | | EXCEPTION. THE MAIN EXHAUST FANS ARE LOCATED ON THE | | | MEZZANINE LEVEL CAUSING THE AIRFLOW TO BE DOWNWARD. | | | | | | 2. PG AC-3 LAUNDRY ROOM DRYER EXHAUST DUCT CAN NEITHER | | | PENETRATE THE SIDE NOR THE BOTTOM OF THE RATED SHAFT | | | BEHIND LAUNDRY ROOM. WHEN A SUITABLE LOCATION FOR DRYER | | | EXHAUST DUCT IS DETERMINED, PLEASE PROVIDE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS.THIS IS ONLY | | | REQUIRED IF THE DEVELOPED DUCT LENGTH EXCEEDS 25 FEET | | | PER FBC,M 504.6. | | | | | | 3. PG AC-7 SER 1 DUCT PENETRATIONS AT BOTTOM OF SHAFTS | | | ARE REQUIRED TO BE PROTECTED PER FBC 705.2.3.3. | | | MOTORIZED FIRE/SMOKE DAMPERS ARE RECOMMENDED IN THESE | | | LOCATIONS AS A STANDARD FUSABLE LINK FIRE DAMPER HAS | | | THE POTENTIAL TO RENDER THESE LIFE SAFETY COMPONENTS | | | INOPERABLE. | | | | | | 4. MANUAL VOLUME DAMPERS ARE NOT REQUIRED ON SMOKE | | | EXHAUST DUCT SYSTEMS AND SHOULD BE REMOVED TO PREVENT | | | POTENTIAL RESTRICTION OF AIRFLOW UNDER EMERGENCY | | | CONDITIONS. | | | | | | 5. PG AC-7 TWO RISERS ON THIS PAGE ARE LABELED "SER 1". | | | PLEASE GIVE EACH RISER A DISTINCTIVE NAME FOR CLARITY. | | | | | | 6. PG AC-2 INTAKE OPENING FOR SF1,AHU1,AHU3 IS IN A | | | PROHIBITED LOCATION PER FBC,M 401.5.1. | | | | | | 7. PG AC-2 GREASE EXHAUST DUCT SHALL BE ENCLOSED IN A | | | RATED SHAFT PER FBC,M 506.3.12. | | | | | | REVIEWED BY: | | | RONALD J REGUEIRO | | | 561.805.6734 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-28 |
Time |
21:30 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-07-28 |
Time |
21:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-05-26 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-05-26 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2005-05-26 00:00:00 | DENIED: | | | 1.PLAN SHEET AC-1 INDICATES RETURN AIR | | | PLENUM PENETRATING THE FLOOR TO AHU-1 | | | AND DOES NOT INDICATE A FIRE DAMPER. | | | PER 2001 FBC/M 607.4, DUCTS PENTRATING | | | ONLY ONE FLOOR CAN BE PROTECTED BY A | | | FIRE DAMPER IN LIEU OF A SHAFT. | | | | | | 2.PLAN SHEET AC-1, PLEASE CLARIFY | | | TERMINATION OF EF-3.IT APPEARS TO | | | TERMINTE AT STAIRWAY, PER 2001 FBC/M | | | 401.5.2, EXHAUST OPENINGS SHALL | | | TERMINATE AS NOT TO CREATE A NUISANCE | | | AND SHALL NOT BE DIRECTED ONTO WALKWAYS. | | | | | | 3.THE PLANS INDICATE FUTURE RESTAURANT | | | PLAS INDICATE THE TERMINATION OF GREASE | | | DUCT ON THE ROOF.PLEASE NOTE GREASE | | | DUCT SHALL BE ENCLOSED IN A 2 HR RATED | | | SHAFT. | | | | | | 4.PLANS INDICATE CORRIDORS BEING | | | UTILIZED AS PLENUMS OR TRANSFERS.PER | | | 2001 FBC/M 601.2, EXITS & EXIT ACCESS | | | CORRIDORS SHALL NOT BE SERVE AS RETURN, | | | EXHAUST RELIEF OR VENTILATION AIR DUCTS | | | OR PLENUMS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
1 |
Status |
P |
Date |
2008-02-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-07 |
Time |
07:08 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-07 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2008-02-07 07:09:21 | REVISION APPROVED--SHT P-11 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
11 |
Status |
P |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-11 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-11 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2008-07-11 16:01:23 | REVISION OK-- SHT P-9--SHT P-11 NOT REQUIRED AS | | | REVISIONS 1 THRU 4 HAVE BEEN PREVIOUSLY APPROVED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
10 |
Status |
F |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-04-22 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-04-22 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2008-04-22 14:50:53 | REVISION DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P-9 NOT APPROVED. SHEET SHOWS SUITE 506 ABOVE | | | THE 8TH FLOOR AND SUITE 406 JUST BELOW THE 8TH FLOOR. | | | ALL RISERS SHALL INDICATE TYPICAL FOR THE PIPE SIZING | | | FROM 5TH FLOOR THRU 7TH FLOOR OR 4TH FLOOR THRU 7TH | | | FLOOR WHICHEVER OR SHOW THE PIPE SIZES THRU THE | | | COMPLETE RISER. PLEASE CLARIFY. SECTIONS 106.1.1 & | | | 606.1. | | | | | | 2. SHT P-11 NO NEW REVISIONS FOUND FROM SHEET REVIEWED | | | ON FEB. 06, 2008, SIGNED, SEALED & DATED 12-05.2007. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
P |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-04-22 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-04-21 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2008-04-22 14:46:09 | REVISIONS APPROVED.--SHTS P-1 THRU P-8, P-10 & | | | P-12.SHT P-1 REVISION #6 WAS NOT FOUND OR APPROVED. | | | SHT P-12 REVISION #3 WAS NOT FOUND OR APPROVED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
F |
Date |
2008-02-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-06 |
Time |
18:46 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-05 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2008-02-06 19:02:46 | REVISION DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | | | | ****FROM PREVIOUS REVISION REVIEW: | | | | | | ******FROM PREVIOUS REVISION REVIEW: | | | | | | NOTE: MOST OF THESE SHEETS SUBMITTED ARE THE EXACT SAME | | | SHEETS SUBMITTED AND DENIED ON THE LAST REVISION | | | SUBMITTAL. NO CHANGES. | | | | | | | | | 1. SHTS P-1, P-4, P-5, P-7, P-8, P-9 & P-10 REVISIONS | | | ARE INDICATED AS REVISIONS 1 & 2. REVISIONS 1 & 2 ARE | | | ALREADY SUBMITTED. THE NEW REVISIONS NUMBERS SHALL STAY | | | IN SEQUENCE ALREADY ESTABLISHED ON THESE PLANS AND, FOR | | | EXAMPLE, SHT P-1 HAS REVISIONS 1 THRU 5, SO THE NEXT | | | REVISIONS SHALL BE 6 & 7. PLEASE INDICATE THE CORRECT | | | REVISION NUMBERS ON EACH REVISED SHEET ACCORDING TO | | | PREVIOUS REVISIONS. SECTION 106.1.3. | | | ****RESPONSE NOTED, BUT P-1 STILL SHOWS A 2ND #2 | | | REVISION AND NEW REVISION #5 PREVIOUSLY DATED 03-07-05 | | | ON THE PLANS SIGNED, SEALED, AND DATED 3-11-05 HAS BEEN | | | CHANGED TO 07-24-06. PLEASE CLARIFY. COMMENT HAS NOT | | | BEEN ADDRESSED. ALSO PLEASE TURN OFF ALL PREVIOUSLY | | | APPROVED REVISION CLOUDS AND REVISION NUMBERS ON THE | | | PLAN. THIS WILL HELP EXPEDITE FUTURE REVISIONS AND | | | ENABLE THE PLAN REVIEWERS TO REVIEW REVISIONS IN A | | | TIMELY MANNER.--SHT P-4 REVISION #2 HAD AN ORIGINAL | | | REVISION DATE 08-27-04, BUT THE NEW SHT P-4 SHOWS THE | | | REVISION DATE 02-25-04 FOR THE SAME REVISION. PLEASE | | | CLARIFY. | | | ******RESPONSE NOTED, BUT THIS IS THE SAME SHEETS WITH | | | THE SAME MARKINGS FROM THE PREVIOUS REVISION SUBMITTAL. | | | NO CHANGES COMMENTS NOT ADDRESSED. | | | | | | 2. OK | | | ******SAME SHEET PREVIOUSLY APPROVED. NOT REQUIRED. | | | 3. OK | | | ******SAME SHEET PREVIOUSLY APPROVED. NOT REQUIRED. | | | | | | 4. OK | | | 5. OK | | | | | | ************NEW COMMENTS************ | | | | | | 1B. SHTS P-2 & P-3 REVISION #4 HAS BEEN CHANGED, THE | | | ORIGINAL REVISION IS DATED 07-06-05, BUT THE NEW SHTS | | | SHOWS REVISION #4 DATED 07-24-06. ALSO REVISIONS | | | INDICATED ON 07-24-06 HAS NOT BEEN FOUND OR APPROVED. | | | SINCE THERE WAS ALREADY A REVISION #4 SHOWN ON THE | | | SIGNED, SEALED SHEETS DATED 07-06-05, ALL REVISIONS | | | AFTER THAT DATE SHALL HAVE THEIR OWN REVISION NUMBER. | | | THE REVISIONS SHALL BE SEQUENTIAL TO TRACK ALL | | | REVISIONS. SECTION 106.3.1. (NOTE: NO REVISION # 4 | | | REVISIONS ARE INDICATED ON THE SHEETS). | | | ******NO RESPONSE, NOT ADDRESSED. | | | | | | 2B. SHT P-5 INDICATES REVISION #3. REVISION #3 FOUND BY | | | THE DIRECTIONAL COMPASS WITH NO CLOUD AND NO APPARENT | | | CHANGE/REVISION. PLEASE CLARIFY. SECTION 106.1.1. | | | ******NO RESPONSE, NOT ADDRESSED. | | | | | | 3B. SHT P-6 REVISION #4 DATE HAS BEEN CHANGED FROM | | | 07-06-05 TO 07-24-06. ALSO REVISIONS INDICATED ON | | | 07-24-06 HAS NOT BEEN FOUND OR APPROVED.--REVISIONS | | | 5 & 6 FROM SET OF PLANS SIGNED, SEALED & DATED 09-23-05 | | | HAVE BEEN DELETED FROM THE REVISION INDEX. SINCE THERE | | | ARE MANY REVISIONS ATTRIBUTED TO REVISION #6, WHY HAS | | | REVISION #6 BEEN DELETED FROM THE REVISION INDEX?-- | | | NO NEW REVISION NUMBER #7 IS INDICATED ON THE NEW SHT | | | P-6. PLEASE CLOUD AND NUMBER NEW REVISIONS AND TURN OFF | | | ALL PREVIOUS CLOUDS OF REVISIONS APPROVED PRIOR TO THIS | | | REVISION AS YOU HAVE FOR REVISIONS #5 & #6. (REVISIONS | | | 1, 2, 3 CLOUDS STILL SHOWN ON PLANS). | | | ******NO RESPONSE, NOT ADDRESSED. | | | | | | 4B. OK | | | 5B. OK | | | 6B. OK | | | 7B. OK | | | | | | 8B. SHT P-8 REVISION #4 ON THE STAMPED PLANS SIGNED, | | | SEALED & DATED 07-06-05 HAS BEEN CHANGED TO 07-24-06. | | | SINCE THE REVISIONS #4 HAS ITS OWN REVISION, A NEW | | | REVISION NUMBER IS REQUIRED FOR ALL NEW REVISIONS. ALSO | | | REVISIONS INDICATED ON 07-24-06 HAS NOT BEEN FOUND OR | | | APPROVED. | | | ******NO RESPONSE, NOT ADDRESSED. | | | | | | 9B. OK | | | | | | 10B. SHT P-9 GAS SYSTEM #1 PER TABLE 402.4(6) MINIMUM | | | SIZE IS 2-1/2". 2" IS SHOWN.--SUBMIT MANUF | | | SPECIFICATION SHEETS FOR THE WATER HEATERS TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA-54, NFPA-58 AND FBC-2004 | | | FUEL GAS SEC. 402.2. | | | ******PIPE SIZES ADDRESSED, BUT MANUF. SPECIFICATION | | | SHEETS NOT SUBMITTED. | | | | | | 11B. OK | | | | | | 12B. SHT P-10 REVISION #3 WAS DATED 07-06-05 AND HAS | | | NOT BEEN CHANGED TO 07-24-06. THIS REVISION HAS NOT | | | BEEN FOUND OR APPROVED. NEW REVISIONS SHALL HAVE NEW | | | REVISION NUMBERS. EXISTING REVISIONS SHALL REMAIN AS | | | APPROVED FOR CONFORMITY TO RECORD RETENTION.-- | | | REVISION #4 WAS DATED 09-16-05 AND NOW CHANGED TO DATE | | | 02-16-07. REVISION HAS NOT BEEN APPROVED. NEW REVISIONS | | | SHALL HAVE NEW REVISION NUMBERS. TURN OFF ALL | | | PREVIOUSLY APPROVED REVISION CLOUDS AND REVISION | | | NUMBERS ON THE PLANS TO HELP EXPEDITE THE REVISION | | | REVIEW. LEAVE REVISION INDEX NUMBER HISTORY CURRENT | | | FROM FIRST REVISION THRU TO THE NEWEST REVISION. | | | ******NO RESPONSE, NOT ADDRESSED. | | | | | | 13B. OK | | | | | | 14B. SHT P-12 GAS WATER HEATERS HAVE CHANGED. SUBMIT | | | MANUF. SPECIFICATIONS FOR GAS APPROVAL. SECTION 402.2. | | | ******NO RESPONSE, NOT ADDRESSED. | | | | | | 15B. OK | | | | | | **********NEW COMMENTS********** | | | | | | 1C. SHT P-7 SANT. RISERS S/1A, S/3 & S/7 VENT STACKS | | | SHALL CONNECT TO THE BASE OF THE SANT. STACK. SECTION | | | 903.4. | | | | | | 2C. SHT P-12 SHOWS FRESH AIR VENTS DELETED FOR THE | | | WATER HEATERS. PLEASE SUBMIT CALCULATIONS FOR | | | COMBUSTION AIR. ( SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
F |
Date |
2007-08-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-08-25 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-08-25 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2007-08-25 17:31:12 | REVISION DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | | | | ****FROM PREVIOUS REVISION REVIEW: | | | | | | | | | 1. SHTS P-1, P-4, P-5, P-7, P-8, P-9 & P-10 REVISIONS | | | ARE INDICATED AS REVISIONS 1 & 2. REVISIONS 1 & 2 ARE | | | ALREADY SUBMITTED. THE NEW REVISIONS NUMBERS SHALL STAY | | | IN SEQUENCE ALREADY ESTABLISHED ON THESE PLANS AND, FOR | | | EXAMPLE, SHT P-1 HAS REVISIONS 1 THRU 5, SO THE NEXT | | | REVISIONS SHALL BE 6 & 7. PLEASE INDICATE THE CORRECT | | | REVISION NUMBERS ON EACH REVISED SHEET ACCORDING TO | | | PREVIOUS REVISIONS. SECTION 106.1.3. | | | ****RESPONSE NOTED, BUT P-1 STILL SHOWS A 2ND #2 | | | REVISION AND NEW REVISION #5 PREVIOUSLY DATED 03-07-05 | | | ON THE PLANS SIGNED, SEALED, AND DATED 3-11-05 HAS BEEN | | | CHANGED TO 07-24-06. PLEASE CLARIFY. COMMENT HAS NOT | | | BEEN ADDRESSED. ALSO PLEASE TURN OFF ALL PREVIOUSLY | | | APPROVED REVISION CLOUDS AND REVISION NUMBERS ON THE | | | PLAN. THIS WILL HELP EXPEDITE FUTURE REVISIONS AND | | | ENABLE THE PLAN REVIEWERS TO REVIEW REVISIONS IN A | | | TIMELY MANNER.--SHT P-4 REVISION #2 HAD AN ORIGINAL | | | REVISION DATE 08-27-04, BUT THE NEW SHT P-4 SHOWS THE | | | REVISION DATE 02-25-04 FOR THE SAME REVISION. PLEASE | | | CLARIFY. | | | | | | 2. OK | | | 3. OK | | | | | | 4. SHT P-9 GAS SYSTEM SHOWS THE SERVICE SIZE TO BE | | | 2-1/2", BUT THE ISOMETRIC SHOWS 2" PIPE. TABLE 402.4(7) | | | INDICATES 2-1/2" REQUIRED. ALSO 2" IS REQUIRED TO EACH | | | WATER HEATER PER TABLE 402.4(7).PLEASE CORRECT THE | | | PIPE SIZING ON THE ISOMETRIC. ALSO INDICATE THE CHANGE | | | OF MATERIAL FROM SCHED. 40 TO SEMIRIGID COPPER. | | | ****RESPONSE NOTED, BUT AS INDICATED, 2-1/2" PIPE IS | | | REQUIRED. SEE TABLE 402.4(6). | | | | | | 5. OK | | | | | | ************NEW COMMENTS************ | | | | | | 1B. SHTS P-2 & P-3 REVISION #4 HAS BEEN CHANGED, THE | | | ORIGINAL REVISION IS DATED 07-06-05, BUT THE NEW SHTS | | | SHOWS REVISION #4 DATED 07-24-06. ALSO REVISIONS | | | INDICATED ON 07-24-06 HAS NOT BEEN FOUND OR APPROVED. | | | SINCE THERE WAS ALREADY A REVISION #4 SHOWN ON THE | | | SIGNED, SEALED SHEETS DATED 07-06-05, ALL REVISIONS | | | AFTER THAT DATE SHALL HAVE THEIR OWN REVISION NUMBER. | | | THE REVISIONS SHALL BE SEQUENTIAL TO TRACK ALL | | | REVISIONS. SECTION 106.3.1. (NOTE: NO REVISION # 4 | | | REVISIONS ARE INDICATED ON THE SHEETS). | | | | | | 2B. SHT P-5 INDICATES REVISION #3. REVISION #3 FOUND BY | | | THE DIRECTIONAL COMPASS WITH NO CLOUD AND NO APPARENT | | | CHANGE/REVISION. PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 3B. SHT P-6 REVISION #4 DATE HAS BEEN CHANGED FROM | | | 07-06-05 TO 07-24-06. ALSO REVISIONS INDICATED ON | | | 07-24-06 HAS NOT BEEN FOUND OR APPROVED.--REVISIONS | | | 5 & 6 FROM SET OF PLANS SIGNED, SEALED & DATED 09-23-05 | | | HAVE BEEN DELETED FROM THE REVISION INDEX. SINCE THERE | | | ARE MANY REVISIONS ATTRIBUTED TO REVISION #6, WHY HAS | | | REVISION #6 BEEN DELETED FROM THE REVISION INDEX?-- | | | NO NEW REVISION NUMBER #7 IS INDICATED ON THE NEW SHT | | | P-6. PLEASE CLOUD AND NUMBER NEW REVISIONS AND TURN OFF | | | ALL PREVIOUS CLOUDS OF REVISIONS APPROVED PRIOR TO THIS | | | REVISION AS YOU HAVE FOR REVISIONS #5 & #6. (REVISIONS | | | 1, 2, 3 CLOUDS STILL SHOWN ON PLANS). | | | | | | 4B. SHT P-7 RISER S/8 DOES NOT REFLECT THE FLOOR PLAN. | | | SHT P-5 SHOWS AN ICE MAKER & A FLOOR SINK ON THE FLOOR | | | PLAN, BUT THE RISER SHOWS NO FLOOR SINK. PLEASE | | | CORRELATE RISER AND FLOOR PLAN INFORMATION. SECTION | | | 106.1.1. | | | | | | 5B. P-7 RISER S/6 WASTE LINES FOR TUBS TO BE CONNECTED | | | TO THE STACK BELOW THE FLOOR UNLESS THE TUBS ARE TO BE | | | RAISED ABOVE THE FLOOR LEVEL. PLEASE CLARIFY. SECTION | | | 106.1.1. | | | | | | 6B. SHT P-7 WATER RISER DIAGRAMS FOR MEN & WOMEN TOILET | | | ROOMS: SHUT OFF VALVES ARE REQUIRED FOR THE W/H'S PER | | | SECTION 606.2(2). PLEASE INDICATE ON RISER. | | | | | | 7B. SHT P-7 WATER PIPING ISOMETRICS FOR UNITS 100, 101, | | | 102, 104, 105, 106 & 108 HAVE A REVISION #4. NO CHANGE | | | IS NOTED. PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 8B. SHT P-8 REVISION #4 ON THE STAMPED PLANS SIGNED, | | | SEALED & DATED 07-06-05 HAS BEEN CHANGED TO 07-24-06. | | | SINCE THE REVISIONS #4 HAS ITS OWN REVISION, A NEW | | | REVISION NUMBER IS REQUIRED FOR ALL NEW REVISIONS. ALSO | | | REVISIONS INDICATED ON 07-24-06 HAS NOT BEEN FOUND OR | | | APPROVED. | | | | | | 9B. SHT P-9 REVISION #4 NOT FOUND OR APPROVED. | | | | | | 10B. SHT P-9 GAS SYSTEM #1 PER TABLE 402.4(6) MINIMUM | | | SIZE IS 2-1/2". 2" IS SHOWN.--SUBMIT MANUF | | | SPECIFICATION SHEETS FOR THE WATER HEATERS TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA-54, NFPA-58 AND FBC-2004 | | | FUEL GAS SEC. 402.2. | | | | | | 11B. SHT P-9 LOBBY REST-ROOMS WATER ISOMETRIC RISER | | | DIAGRAM IS A REVISION & SHALL BE INDICATED AS SUCH WITH | | | A CLOUD & A REVISION NUMBER ASSIGNED TO IT. SECTION | | | 106.1.3. | | | | | | 12B. SHT P-10 REVISION #3 WAS DATED 07-06-05 AND HAS | | | NOT BEEN CHANGED TO 07-24-06. THIS REVISION HAS NOT | | | BEEN FOUND OR APPROVED. NEW REVISIONS SHALL HAVE NEW | | | REVISION NUMBERS. EXISTING REVISIONS SHALL REMAIN AS | | | APPROVED FOR CONFORMITY TO RECORD RETENTION.-- | | | REVISION #4 WAS DATED 09-16-05 AND NOW CHANGED TO DATE | | | 02-16-07. REVISION HAS NOT BEEN APPROVED. NEW REVISIONS | | | SHALL HAVE NEW REVISION NUMBERS. TURN OFF ALL | | | PREVIOUSLY APPROVED REVISION CLOUDS AND REVISION | | | NUMBERS ON THE PLANS TO HELP EXPEDITE THE REVISION | | | REVIEW. LEAVE REVISION INDEX NUMBER HISTORY CURRENT | | | FROM FIRST REVISION THRU TO THE NEWEST REVISION. | | | | | | 13B. SHT P-11 CONDENSATE DRAIN PIPING ISOMETRIC RISER | | | DIAGRAM RISER C/1 SHOWS 2" RISER DRAINING INTO 1-1/2" | | | BRANCH LINE. THIS IS NOT APPROVED PER SECTION 704.2. | | | PLEASE CORRECT RISER DIAGRAM. | | | | | | 14B. SHT P-12 GAS WATER HEATERS HAVE CHANGED. SUBMIT | | | MANUF. SPECIFICATIONS FOR GAS APPROVAL. SECTION 402.2. | | | | | | 15B. GENERAL NOTE: ALL SHEETS, TURN OFF ALL PREVIOUS | | | REVISION CLOUDS & NUMBERED TRIANGLES THAT HAVE BEEN | | | PREVIOUSLY APPROVED FROM THE FLOOR PLAN, ISOMETRICS | | | ETC. LEAVING THESE ON CREATS CONFUSION AND ADDS TO THE | | | PLAN REVIEW TIME AND TURN AROUND. LEAVE THE REVISION | | | INDEX NUMBERS AND REVISION DATES AS APPROVED AND NEW | | | REVISION NUMBERS SHALL BE ADDED FOR NEW REVISIONS | | | WITHOUT DUPLICATING THE REVISIONS NUMBERS. SECTION | | | 106.1.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2007-05-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-05-17 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-05-14 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2007-05-17 08:02:51 | REVISION DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | | | | | | | 1. SHTS P-1, P-4, P-5, P-7, P-8, P-9 & P-10 REVISIONS | | | ARE INDICATED AS REVISIONS 1 & 2. REVISIONS 1 & 2 ARE | | | ALREADY SUBMITTED. THE NEW REVISIONS NUMBERS SHALL STAY | | | IN SEQUENCE ALREADY ESTABLISHED ON THESE PLANS AND, FOR | | | EXAMPLE, SHT P-1 HAS REVISIONS 1 THRU 5, SO THE NEXT | | | REVISIONS SHALL BE 6 & 7. PLEASE INDICATE THE CORRECT | | | REVISION NUMBERS ON EACH REVISED SHEET ACCORDING TO | | | PREVIOUS REVISIONS. SECTION 106.1.3. | | | | | | 2. SHTS P-1 & P-5, (NEW) REVISION 1 NOT FOUND. | | | | | | 3. SHT P-8 DRAINAGE PIPING SHALL NOT BE REDUCED IN THE | | | DIRECTION OF FLOW PER SECTION 704.2. SEE RISER "F" | | | SHOWS 4" ON THE HORIZONTAL & 3" AT THE TOP OF THE RISER | | | ON THE VERTICAL. PLEASE CORRELATE PIPE SIZES. | | | | | | 4. SHT P-9 GAS SYSTEM SHOWS THE SERVICE SIZE TO BE | | | 2-1/2", BUT THE ISOMETRIC SHOWS 2" PIPE. TABLE 402.4(7) | | | INDICATES 2-1/2" REQUIRED. ALSO 2" IS REQUIRED TO EACH | | | WATER HEATER PER TABLE 402.4(7).PLEASE CORRECT THE | | | PIPE SIZING ON THE ISOMETRIC. ALSO INDICATE THE CHANGE | | | OF MATERIAL FROM SCHED. 40 TO SEMIRIGID COPPER. | | | | | | 5. SHT P-9 WATER RISER DIAGRAM SHOWS THE 8TH FLOOR | | | BETWEEN THE 4TH & 5TH FLOORS. ALSO SHOWN IS 3/4" WATER | | | SUPPLY TO THE 5TH FLOOR AND 1" FROM THE 4TH FLOOR UP TO | | | THE 8TH FLOOR. THE WATER RISER DIAGRAM SHALL REFLECT | | | WHAT WILL BE INSTALLED. IF SOME FLOORS ARE TYPICAL FOR | | | PIPE SIZES, (EXAMPLE 2ND THRU 4TH FLOORS 2 INCH PIPE), | | | THAT CAN BE INDICATED ON THE RISER. PLEASE SUBMIT | | | CALCULATIONS FOR THE WATER PIPING PER SECTION 604. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2006-10-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-06 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-10-06 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2006-10-06 00:00:00 | REVISION DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | | | | 1. REVISIONS SHALL BE CLOUDED AND | | | REVISION NUMBER SHALL BE SHOWN AT THE | | | REVISION. WITH THE WORK LOAD WE HAVE I | | | CAN NOT SPEND TIME SEARCHING ALL SYSTEMS | | | ON ALL SHEETS WHEN THERE ARE ONLY | | | CHANGES TO SMALL PORTIONS OF THE SHEETS. | | | SECTION 104.2.1.3 (SEE HIGHLIGHTED AREAS | | | OF SHEETS P-1 & P-2 ON ONE SET FOR | | | EXAMPLE). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-09-27 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2005-09-27 00:00:00 | | | | 9-27-05PES | | | REVISOINS FOR PREVIOUS NOTES. | | | ROOF DRAINS AND O/F. | | | ALSO WATER HEATER NOTE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-10-04 |
Time |
08:38 |
Rev Time |
0.56 |
| Received By |
kstevens |
Date |
2005-08-22 |
Time |
17:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-06 |
Time |
12:07 |
Rev Time |
6.50 |
| Received By |
kstevens |
Date |
2005-08-05 |
Time |
18:31 |
Sent To |
|
|
| Notes |
| 2005-08-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | FROM PREVIOUS REVIEW: | | | | | | 1. CALCULATIONS FOR PRIMARY AND | | | SECONDARY ROOF DRAINS. SHEET P-6 | | | INDICATES SIZE OF SECONDARY ROOF DRAINS | | | REQUIRED AS 18 SQ. IN., BUT MINIMUM 22 | | | SQ. IN. REQUIRED PER SECTION 1107 AND | | | TABLE 1106.3 IN MOST SECTIONS. A MINIMUM | | | OF 36 SQ.IN. IS REQUIRED IN SECTIONS 6 | | | AND 7. - PLEASE RECHECK ALL AREAS AS | | | SOME AREAS SHOW NO VERTICAL AREAS OR | | | UPPER ROOF AREAS AND THEY ARE NEXT TO | | | PARAPET WALLS, BELVEDERE WALLS & ROOFS, | | | SPA EQUIPMENT OR RESTROOM WALLS, | | | STAIRWAY WALLS ECT. SHOW ALL WALLS AND | | | ROOF AREAS THAT DRAIN ONTO ROOFS IN | | | CALCULATIONS. (SEE CALCULATIONS ATTACHED | | | FOR AREAS 1 & 2) - SCUPPER SIZES | | | INDICATED ON SHT P-6 CALCULATIONS STATE | | | 6"X1.5". THE BUILDING ELEVATIONS | | | INDICATE THAT THE SCUPPERS WILL BE | | | CYLINDRICAL AND IF SO PLEASE INDICATE | | | WHAT THE 1.5" MEASUREMENT IS REFERING | | | TO. | | | 8. SHT P-12 WATER HEATER DETAIL. NO T&P | | | LINES SHOWN ON THE WATER HEATERS. | | | SECTION 504.5 - BOTTOM FED WATER HEATERS | | | AND STORAGE TANK SHALL HAVE A VACUUM | | | RELIEF VALVE INSTALLED AT THE HIGHEST | | | POINT OF THE WATER INLET. SECTION 504.2 | | | WATER HEATERS SHALL BE PIPED ACCORDING | | | TO MANUFACTURES INSTALLATION | | | INSTRUCTIONS. SECTION 502.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-04-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-22 |
Time |
18:08 |
Rev Time |
8.25 |
| Received By |
kstevens |
Date |
2005-04-22 |
Time |
18:08 |
Sent To |
|
|
| Notes |
| 2005-04-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHTS A-108, A-109, & P-6 SUBMIT | | | CALCULATIONS FOR PRIMARY AND SECONDARY | | | ROOF DRAINS PER SECTIONS 1106 & 1107 AND | | | ALL SUBSECTIONS. SHOW TOTAL SQUARE | | | FOOTAGE FOR EACH AREA BEING DRAINED. | | | SHOW 1/2 AREA OF ALL VERTICAL WALLS | | | INCLUDING PARAPETS, AND AREAS OF ROOF | | | THAT DRAIN ONTO THE DIFFERENT AREAS | | | ADDED TO ROOF AREA IN CALCULATIONS. SHOW | | | THE LOCATION OF ALL SECONDARY ROOF | | | DRAINS INCLUDING AREAS THAT ARE NOT | | | ADJACENT TO THE OUTER WALLS. | | | 2) SHTS A-103 & P-2. SHT A-103 SHOWS A | | | STORAGE ROOM, BUT P-2 SHOWS A LAUNDRY - | | | WATER HEATER ROOM. PLEASE CLARIFY. | | | SECTION 104.2.1. | | | 3) SHTS P-1 & P-2. SHT P-1 SHOWS SANT. | | | RISER #11 UP TO MEZZ. LEVEL, BUT DOES NT | | | SHOW UP ON P-2. PLEASE CORRELATE PLANS. | | | SECTION 104.2.1. | | | 4) SHT P-6 AREAS AROUND THE ENDS OF THE | | | SPA, WHERE THE SPA HAS BEE REDUCED IN | | | SIZE, SHALL BE INCREASED TO REFLECT THE | | | LARGER AREAS TO BE DRAINED. SECTION | | | 104.2.1. | | | 5) SHT P-7 SHOWS WATER PIPING TO GROUND | | | FLOOR LAUNDRY, BUT THIS HAS BEEN DELETED | | | ON THE FLOOR PLAN. PLEASE DELETE WATER | | | DETAIL FOR GROUND FLOOR LAUNDRY. SECTION | | | 104.2.1. | | | 6) SHT P-7 SANITARY RISER S/8 AND BRANCH | | | LINE TO RISER ARE NOT SHOWN ON THE BLDG. | | | DRAIN ISOMETRIC. SECTION 104.2.1. | | | 8) SHT P-12 WATER HEATER DETAIL. T&P | | | RELIEF VALVE DISCHARGE LINES SHOW VALVES | | | | | | AND ARE TIED TOGETHER AND VALVED PRIOR | | | TO ENTERING THE STORAGE TANK. THIS IS | | | NOT APPROVED PER SECTIONS 504.5.1 AND | | | 504.7.1. - ALSO THE STORAGE TANK SHOWS | | | NO DISCHARGE PIPING. SHOW THE | | | TERMINATION POINT FOR RELIEF VALVES.- | | | BOTTOM FED WATER HEATERS AND STORAGE | | | TANKS SHALL HAVE A VACUUM RELIEF VALVE | | | INSTALLED. SECTION 504.2.-WATER | | | HEATER SHOW NO HOT WATER LINES EXITING | | | THE HEATERS. - WATER HEATERS SHALL BE | | | PIPED IN SUCH AN ARRANGEMENT TO SUPPLY | | | AND DISCHARGE SIMULTANEOUSLY FROM EACH | | | WATER HEATER. | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
8 |
Status |
P |
Date |
2008-04-25 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-04-25 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-04-25 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2008-04-25 09:28:59 | ZONING REVIEW: PASSED | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
7 |
Status |
P |
Date |
2008-01-22 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-01-22 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-01-22 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2008-01-22 14:10:09 | ZONING REVIEW: PASSED WITH PROVISO. | | | | | | PROVISO NOTES SHALL BE ADDRESSED UPON RESUBMITTAL OR | | | REVISION OF DRAWINGS: | | | | | | 1) ON REVISED LANDSCAPE DRAWINGS, PLEASE INDICATE | | | STREET TREES ALONG FERN LOCATED AT 30' O.C.. THIS WILL | | | YIELD APPROXIMATELY THREE TREES. SPECIES TO BE | | | HIGH-RISE LIVE OAK IN 5'X5' TREE GRATES AGAINST CURB. | | | SEE CITY FOR TYPICAL MODEL. | | | 2) ON LANDCAPE DRAWINGS, PLEASE INDCIATE THAT | | | ORNAMENTAL POTS ON ROOF TOP SHALL BE ANCHORED AS TO BE | | | PERMANENT. | | | 3) SCREENING MATERIAL FOR MECHANICAL PARKING TO BE | | | REVIEWED AND APPROVED WHEN SUBMITTED. | | | 4) NO ADDITIONAL ARCHITECTURAL TREATMENT INDICATED ON | | | EAST AND WEST ELEVATION. PLEASE CONSIDER ADDITION SOME | | | ADDITIONAL DETAILS OR SCORING TO IMPROVE DESIGN. | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-08-06 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-08-06 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2007-08-06 14:29:19 | ZONING REVIEW: FAILED | | | | | | OLD COMMENTS UNADDRESSED: | | | | | | 1) PARKING STRUCTURE SHALL BE INCLUDED AS PART OF THE | | | BUILDING PERMIT SET. | | | 2) ACCESS DRIVES TO PARKING SHALL BE AMINIMUM OF 11 | | | FEET IN WIDTH. PLANS SHOW 9'-0" CLEAR AT ENDS OF DRIVES | | | - THIS WILL NOT BE WIDE ENOUGH FOR VEHICULAR PASSAGE. | | | 3) MECHANICAL PARKING INDICATED ON NORTH SIDE OF | | | PARKING AREA WAS NOT INCLUDED IN THE DAC APPROVAL. | | | PLEASE REMOVE THIS MECHANICAL PARKING. | | | 4) FOR THE PARKING SCREENING, PLEASE PROVIDE A KICK | | | PLATE AT THE BOTTOM AND SEPARATE GRILLE/MESH MATERIAL | | | AT LEAST 8 INCHES FROM THE COLUMN AND KICK PLATE. NO | | | SECTION DETAIL IS PROVIDED IN THIS SET TO VERIFY. | | | 5) PLEASE PROVIDE LANDSCAPE DRAWINGS TO CONFIRM | | | APPROPRIATE SCREENING FOR MECHANICAL PARKING. 5'-0" | | | LANDSCAPE BUFFER NEEDED ON SIDE AND REAR FOR PLANT | | | MATERIALS. | | | | | | NEW COMMENTS: | | | | | | 1) PLEASE UPDATE COVER SHEET TO REFLECT CURRENT | | | REVISION DATE. | | | 2) PLEASE PROVIDE GROUND FLOOR LANDSCAPE PLAN | | | INDICATING STREET TREES, AND LANDSCAPING AT REAR | | | ADJACENT TO PARKING SCREENING. PLEASE REFER TO DAC | | | MINUTES FOR BOARD RECOMMENDATIONS. | | | 3) PROVIDE A TABLE INDICATING COMPLIANCE WITH ROOFTOP | | | TERRACE REQUIREMENTS - IE LANDSCAPE COVERAGE AND | | | BUILDING COVERAGE. REFER TO ART IV SECTION 94-108 | | | (B)(5). | | | 4) A-101 - INDICATE ACCESSIBLE ROUTE FROM ADA PARKING. | | | "LANDCAPE AREA" NOTE SEEMS TO BE IN WRONG LOCATION AND | | | BLOCK SIDEWALK ACCESS. | | | 5) MEZZANINE AREA SHALL NOT EXCEED BUILDING CODE | | | ALLOWANCE. PLEASE CONFIRM. | | | 6) A-203 - EAST AND WEST ELEVATIONS REQUIRE ADDITIONAL | | | ARCHITECTURAL TREATMENT. PLEASE ADD BANDS, APPLIED | | | CORNICE, ETC TO BREAK UP BLANK FACADE. CONTACT STAFF | | | FOR ADDITIONAL RECOMMENDATIONS. | | | | | | MATT FLIS - 822-1445 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2007-05-10 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-05-10 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-05-10 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2007-05-10 14:46:08 | ZONING REVIEW: FAILED | | | | | | - THIS DRAWING SET IS NOT REVIEWABLE AT THIS TIME; MANY | | | MISSING DRAWINGS AND/OR DRAWINGS WHICH ARE NOT UPDATED | | | TO REFLECT CHANGE FROM FIVE-STORY TO EIGHT-STORY | | | BUILDING | | | - PLANS MISSING UPDATED SECTIONS, ELEVATIONS, ETC | | | - PLEASE SUBMIT MATERIALS FOR PARKING SYSTEM AND | | | INDICATE COMPLIANCE WITH ALL CONDITIONS AS APPROVED BY | | | THE DOWNTOWN ACTION COMMITTEE | | | - A TDR CERTIFICATE MUST BE SUBMITTED WITH BUILDING | | | PERMIT FOR ADDITIONAL FLOORS (6 THROUGH 8) | | | - PLEASE REVIEW ALL PREVIOUS COMMENTS FROM PLANNING | | | REGARDING THIS PERMIT; NEW COMMENTS WILL BE PROVIDED | | | WITH SUBMITTAL OF COMPLETE SET | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2006-09-28 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2006-09-28 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2006-09-28 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2006-09-28 00:00:00 | PERMIT FOR THE 8 STORY BUILDING | | | 1. PARKING STRUCTURE SHAL BE INCLUDED AS | | | PART OF THE BUILDING PERMIT SET. | | | 2. ACCESS DRIVES TO PARKING SHALL BE A | | | MINIMUM ON 11 FEET IN WIDTH. | | | 3. REQUIRED HANDICAP SPACES FOR THIS | | | PROJECT IS ONLY 4 SPACES. | | | 4. LANDSCAPE STRIP ALONG SIDE PROPERTY | | | LINE SHALL BE MINIMUM FIVE FEET IN | | | WIDTH. | | | 5. MECHANICAL PARKING ELEVATORS ON THE | | | NORTH SIDE OF PARKING AREA WERE NOT | | | INLCUDED ON DAC APPOVAL FOR | | | PARKING.PLEASE PLEASE REPLACE MECHANICAL | | | SPACES FOR REGULAR PARKING SPACES. | | | 6. FOR THE PARKING SCREEN, PLEASE | | | PROVIDE A KICK PLATE AT THE BOTTOM AND | | | SEPARATE THE GRILL AT LEAST 8 INCHES | | | FROM THE COLUMN AND THE KICK PLATE. | | | 7. PLEASE PROVIDE LANDSCAPE DRAWINGS TO | | | CONFIRM CODE COMPLIANCE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-08-29 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2006-08-29 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2006-08-29 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2006-08-29 00:00:00 | FOUNDATION ONLY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2005-09-01 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2005-09-01 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2005-09-01 00:00:00 | PROVISO: STREET TREES SHALL BE PLANTED | | | IN FRONT OF THE BUILDING ACCORDING TO | | | ARTICLE IV SECTION 94-108 (G) BEFORE CO. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2005-04-29 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2005-04-29 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2005-04-29 00:00:00 | 1. PLEASE PROVIDE LANDSCAPE DRAWING FOR | | | THE ROOFTOP TERRACE TO CONFIRM | | | COMPLIANCE WITH THE REGULATION. | | | 2. PLEASE EXPLORE ALTERNATIVES TO COVER | | | THE METAL GRILL ON THE FRONT ELEVATION. |
|
|