| Plan Review Stops For Permit 05031124 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-19 |
Time |
17:02 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2005-07-19 |
Time |
17:02 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-05-20 |
Time |
11:55 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-05-20 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2005-05-20 00:00:00 | PERMIT: 05031124 | | | ADD: 1515 N FLAGLER #320 | | | CONT: POINTE SITE DEV | | | TEL: (954) 709-1926 | | | 2001 FL BLD CODE= 2001 FLORIDA BUILDING | | | CODE * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | *****COMMENTS NOT ADDRESSED FROM THE | | | FIRST REVIEW****** | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3) TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY | | | | | | 4) 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | SEE RECEPTION DOOR AND STORAGE DOOR!!!! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-04-14 |
Time |
07:46 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-04-14 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2005-04-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05031124 | | | ADD: 1515 N FLAGLER #320 | | | CONT: POINTE SITE DEV | | | TEL: (954) 709-1926 | | | 2001 FL BLD CODE= 2001 FLORIDA BUILDING | | | CODE * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3) TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY | | | | | | 4) 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-26 |
Time |
17:45 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-07-26 |
Time |
17:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-29 |
Time |
19:49 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-06-29 |
Time |
19:30 |
Sent To |
|
|
| Notes |
| 2005-06-29 00:00:00 | ******** UNSAT ********** | | | | | | PLEASE SEE PLANS HAVE NOW COME IN WITH | | | CHANGES FROM PREVIOUS PLANS SUBMITTED | | | FOR REVIEW. | | | | | | 1)NOTE: PLEASE SEE 110.26, 450.9, | | | 450.13, 450.21 ETC. | | | MINIMUM WORKING CLEARANCES ARE NOT | | | REQUIRED IF THE EQUIPMENT IS SUCH THAT | | | IT IS NOT LIKELY TO REQUIRE EXAMINATION, | | | ADJUSTMENT, SERVICING, OR MAINTENANCE | | | WHILE ENERGIZED. HOWEVER, ?SUFFICIENT? | | | ACCESS AND WORKING SPACE ARE STILL | | | REQUIRED BY THE OPENING PARAGRAPH OF | | | 110.26, PLEASE SEE 450 AS NOTED ABOVE | | | FOR MIN AREA. | | | IF USEING SCALE ON PLANS, LESS THAN 9" | | | IS SHOWN TO REACH DISC, ETC. | | | | | | 2)NOTE: PLEASE SHOW ATTACHMENT FOR | | | TRANSFORMER GROUNDING. 250.30 | | | PLEASE SEE NOTE MENTIONS TO BLDG | | | SECONDARY GRND? PER APPLICABLE CODE. | | | PLEASE SEE FBC 104.2.1, CODE SHALL NOT | | | BE REFERENCED IN WHOLE OR IN PART FOR | | | TECHNICAL AREAS. | | | | | | PLEASE REMOVE OLD/VOIDED SHEETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-03 |
Time |
15:21 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-05-03 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2005-05-03 00:00:00 | *** UNSAT *** | | | | | | 1)NOTE: PLEASE SEE PREVIOUS REVIEW WAS | | | SET UP AS "PROVISO" FOR CORRECTIONS TO | | | BE MADE. PLEASE SEE NEW ELECTRICAL | | | SHEETS WERE SUBMITTED AND NO CORRECTIONS | | | WERE MADE. | | | | | | 2)NOTE: PLEASE SEE PREVIOUS BLDG REVIEW | | | COMMENTS WHICH REQUESTED ALL OLD/VOIDED | | | SHEETS BE REMOVED FROM SETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | PLEASE SEE MULTIPLE SHEETS WERE | | | SUBMITTED LOOSELY AND NOT INSERTED AS | | | REQUIRED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-24 |
Time |
13:17 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-03-24 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2005-03-24 00:00:00 | ********** PROVISO/ REVISION ********** | | | | | | 1)NOTE: PLEASE SHOW LOAD ON EXISTING | | | GUTTER/TAP ALONG WITH NEW LOAD ADDED. | | | 215.5,220 | | | | | | PLEASE SUBMIT THE ABOVE BEFORE ROUGH | | | ELECTRICAL INSPECTION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-15 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-15 |
Time |
15:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-04-06 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-04-06 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-04-06 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-25 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-25 |
Time |
11:06 |
Sent To |
E |
|
| Notes |
| 2005-07-25 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-15 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-15 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2005-06-20 00:00:00 | COMM BOARD #46 | | | | | 2005-06-15 00:00:00 | WAITING FOR COMM BOARD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-02 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-02 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2005-05-02 00:00:00 | TO "COMM" BD#23 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-04-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-04-18 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-03-23 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2005-03-23 00:00:00 | TO "COMM" BD#6 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-04-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-04-08 |
Time |
14:14 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-04-08 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2005-04-08 00:00:00 | PROVISO: | | | 1.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC/M | | | 307.2.3. | | | | | | 2.FIRE DAMPERS ARE REQUIRED FOR DUCTS | | | PENETRATING FIRE RATED WALLS OR SHAFT | | | WALLS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-07-14 |
Time |
07:55 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-07-14 |
Time |
07:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-27 |
Time |
06:31 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-05-26 |
Time |
19:46 |
Sent To |
|
|
| Notes |
| 2005-05-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SUBMIT TWO SETS OF PLANS FOR REVIEW. | | | INDIVIDUAL SHEETS NOT APPROVED. REMOVE | | | ALL OLD/VOID SHEETS AND SUBMIT ONE SET | | | FOR COMPARISON. SECTION 104.2.1. | | | 2) BREAK ROOM SINK NOW INDICATED AS A | | | WORK SINK. SECTION 11-4.1.1(3) STATES | | | "AREAS USED ONLY BY EMPLOYEES AS WORK | | | AREAS"THIS AREA IS ALSO SHOWS A | | | REFRIGERATOR SEEMS TO BE ALSO A BREAK | | | ROOM AREA. SINK SHALL COMPLY WITH | | | SECTION 11-4.24 AND ALL SUBSECTIONS | | | UNLESS THE AREA IS A WORK AREA ONLY. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-03-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-26 |
Time |
12:15 |
Rev Time |
0.55 |
| Received By |
kstevens |
Date |
2005-03-26 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2005-03-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A1 ACCESSIBLE TOILET ROOM DETAIL, | | | SHOW COMPLIANCE WITH THE FOLLOWING: | | | A) 11-4.16.5 FLUSH CONTROLS | | | B) HEIGHT & CLEARANCES 11-4.19.3 (29") | | | C) EXPOSED PIPES & SURFACES 11-4.19.4 | | | D) FAUCEST 11-4.19.5 | | | E) MEASUREMENT FORM CENTERLINE OF LAV | | | TO VANITY TO BE MIN. 15" TO CENTER ON | | | 30" DIMENSION OF CLEAR FLOOR SPACE. (SEE | | | FIGURE 32). | | | 2) SUBMIT A DETAIL FOR THE BREAK ROOM | | | SINK SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | A) HEIGHT 11-4.24.2 | | | B) KNEE CLEARANCE 11-4.24.3 | | | C) SINK DEPTH 11-4.24.4 | | | D) CLEAR FLOOR SPACE 11-4.24.5 - | | | FORWARD APPROACH REQUIRED. MAXIMUM 19" | | | UNDERNEATH THE SINK. NO CABINET DOORS | | | ALLOWED IN THE CLEAR FLOOR SPACE. | | | E) EXPOSED PIPES & SURFACES 11-4.24.6 | | | F) FAUCETS 11-4.24.7 | | | 3) SHT P1 WATER RISER, FULL OPEN VALVES | | | ARE REQUIRED ON EVERY WATER DOWN-FEED | | | LINE. SECTION 606.1(4) | | | 4) SHT P1 INSTA-HOT WATER HEATERS SHALL | | | BE LISTED. SUBMIT MANUF. SPECIFICATION | | | SHEETS TO VERIFY. SECTION 303.4 | | | 5) A DRINKING FOUNTAIN IS REQUIRED PER | | | TABLE 403.1. IF A DRINKING FOUNTAIN IS | | | AVAILABLE IN THE COMMON AREA PLEASE | | | INDICATE ON PLANS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|