| Plan Review Stops For Permit 05031079 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-08-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-14 |
Time |
16:02 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-14 |
Time |
16:02 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-08-14 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-27 |
Time |
16:34 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-07-27 |
Time |
16:29 |
Sent To |
PC |
|
| Notes |
| 2005-07-27 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05031079 | | | ADD: 7608 S FLAGLER | | | CONT: ANDIO ELECTRIC | | | TEL: (561)926-1456 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | | | | THE PLANS SUBMITTED INDICATE THAT THE | | | WINDOWS ARE FIXED TYPE WINDOWS. WHAT ARE | | | THESE ROOMS USED FOR? IF SLEEPING ROOMS | | | PROVIDE DOCUMENTATION OF EGRESS WINDOWS. | | | 2001 FL BLD CODE, 1005.4: | | | PROVIDE EMERGENCY EGRESS WINDOWS IN | | | SLEEPING ROOMS WITH A MINIMUM NET CLEAR | | | OPENING HEIGTH OF 24" AND NET CLEAR | | | OPENING WIDTH OF 20" AND A NET CLEAR | | | OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR | | | OPENINGS ARE PERMITTED TO HAVE A NET | | | CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH | | | SHALL NOT BE MORE THAN 44 " ABOVE THE | | | FINISH FLOOR. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-04-15 |
Time |
16:19 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2005-04-15 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2005-04-15 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | SUBMIT A DRAWING OF THE CONCRETE SLAB | | | FOR THE INSTALLATION OF THE STANDBY | | | GENERATOR. SHOW THE METHOD OF ANCHORING | | | THE GENERATOR TO THE SLAB. POSITION THE | | | SLAB TO COMPLY WITH ALL REQUIRED | | | CLEARANCES. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-11 |
Time |
12:52 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-11 |
Time |
11:37 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-24 |
Time |
08:07 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-24 |
Time |
07:48 |
Sent To |
M |
|
| Notes |
| 2005-06-24 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SUBMIT ALOAD CALCULATION | | | INDICATING THE LOAD TO BE SERVED BY THE | | | GENERATOR. | | | | | | 2} THE RISER INDICATES A MANUAL TRANSFER | | | SWITCH. THE SPEC'S SUBMITTED WERE FOR A | | | ATS. PLEASE CLARIFY, SUBMIT CORRECT | | | SPEC'S AND/OR CHANGE RISER INFORMATION. | | | | | | 3} PLEASE INDICATE THE PRIME MOVER, L.P. | | | OR NATURAL. IF LP SHOW TANK. | | | | | | IF YOU HAVE QUESTIONS JON, PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-04-15 |
Time |
13:23 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-04-15 |
Time |
10:34 |
Sent To |
B |
|
| Notes |
| 2005-04-15 00:00:00 | | | | THE SELETED LOADS (PANELS A,E&C)EXCEED | | | THE OUTPUT OF THE GENERATOR. | | | PLEASE INDICATE SELECTED LOADS THAT ARE | | | IN ACCEPTABLE LIMITS. SEE ARTICLE 702, | | | 702.5. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-29 |
Time |
15:26 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-06-29 |
Time |
15:26 |
Sent To |
E |
|
| Notes |
| 2005-06-29 00:00:00 | GAS PERMI # 05031529 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-20 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-20 |
Time |
12:03 |
Sent To |
E |
|
| Notes |
| 2005-06-20 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-01 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-01 |
Time |
11:30 |
Sent To |
G |
|
| Notes |
| 2005-04-01 00:00:00 | TO "G" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-28 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-28 |
Time |
10:00 |
Sent To |
Z |
|
| Notes |
| 2005-03-28 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-18 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-18 |
Time |
08:54 |
Sent To |
E |
|
| Notes |
| 2005-03-18 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-07-06 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-07-06 |
Time |
17:25 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-04-12 |
Time |
14:16 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2005-04-12 |
Time |
14:16 |
Sent To |
E |
|
| Notes |
| 2005-04-12 00:00:00 | DENIED: | | | PROVIDE CLEARANCE FROM BUILING, LOT | | | LINES, FRESH AIR INTAKES, WINDOWS AND | | | DOORS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-04-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-02 |
Time |
14:40 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-04-02 |
Time |
14:40 |
Sent To |
M |
|
| Notes |
| 2005-04-02 00:00:00 | INFORMATIONAL NOTE: | | | | | | - NO PERMIT PERTAINING TO A GENERATOR | | | SHALL BE ISSUED UNTIL AN APPLICATION FOR | | | THE GENERATOR, WITH A REVIEW FOR THE | | | GENERATOR BY BUILDING, ELECTRICAL, | | | MECHANICAL, AND ZONING PLAN REVIEWERS. | | | THE BUILDING REVIEW WILL BE FOR THE SLAB | | | AND ANCHORING, (SUBMIT A DETAIL), | | | MECHANICAL REVIEW FOR THE EXHAUST, | | | (PROPER CLEARANCES FROM OPENINGS IN | | | HOUSES INCLUDING ADJACENT). | | | NOTED: AN ELECTRICAL REVIEW, AND ZONING | | | REVIEW FINISHED AND A GAS REVIEW WILL BE | | | FINISHED. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-31 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-31 |
Time |
09:57 |
Sent To |
I |
|
| Notes |
|
|