| Plan Review Stops For Permit 05030986 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-10-18 |
Time |
12:44 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-10-18 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2005-10-18 00:00:00 | REVISED WINDOW PRESSURE CALCS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2005-10-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-10-06 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-10-06 |
Time |
17:28 |
Sent To |
PC |
|
| Notes |
| 2005-10-07 00:00:00 | ARCHITECT REMOVED LANGUAGE FROM TITLE | | | BLOCK, WILL INFORM AS TO GUIDANCE FROM | | | ATTORNEY | | 2005-10-06 00:00:00 | FAXED RESPONSE FROM ARCHITECT TO LES | | | SMITH, ATTORNEY FOR FLORIDA BOARD OF | | | ARCHITECTS.ON SMH DESK PENDING | | | RESPONSE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-09-23 |
Time |
00:03 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-09-23 |
Time |
00:03 |
Sent To |
|
|
| Notes |
| 2005-09-23 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | REVISION, A1 | | | | | | 1.)SEE ATTACHED FROM THE DBPR WEBSITE, | | | BOARD OF ARCHITECTS, FREQUENTLY ASKED | | | QUESTIONS.A CERTIFICATE OF | | | AUTHORIZATION IS REQUIRED FOR MAURICE | | | MENASCHE, AIA ARCHITECTURE & PLANNING. | | | | | | PLEASE NOTE THAT I CALLED MR. MENASCHE | | | AND LEFT A MESSAGE TO TRY TO DISCUSS | | | OVER THE TELEPHONE, BUT DID NOT RECEIVE | | | A RETURN CALL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-09-20 |
Time |
11:41 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-09-20 |
Time |
11:41 |
Sent To |
PC |
|
| Notes |
| 2005-09-21 00:00:00 | REVISED A2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2005-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-24 |
Time |
14:04 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-24 |
Time |
14:04 |
Sent To |
PC |
|
| Notes |
| 2005-07-24 00:00:00 | ****CORRECTIONS**** | | | BUTT GLASS ENGINEERING | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.) THE PERMIT WAS ISSUED WITH A PROVISO | | | THAT THE BUTT GLASS WINDOWS WOULD BE ON | | | A SEPARATE PERMIT.APPLY FOR A SEPARATE | | | PERMIT FOR THESE ITEMS WITH THE | | | APPROPRIATE PAPERWORK. | | | | | | 2.)THE SAME ENGINEERING THAT WAS | | | DENIED PREVIOUSLY WAS RESUBMITTED.THE | | | PRESSURES ON THE PLAN FOR THESE OPENINGS | | | ARE +31/-41, SHEET A2.THE ENGINEERING | | | HAS A DP OF +30.1/-32.8.PLEASE ADDRESS | | | BEFORE APPLYING FOR A PERMIT - DO NOT | | | SUBMIT THE SAME PAPERWORK UNLESS YOU | | | REVISE SHEET A2 AS DISCUSSED WITH THE | | | ENGINEER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-06-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-23 |
Time |
11:52 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-06-23 |
Time |
11:36 |
Sent To |
PC |
|
| Notes |
| 2005-06-23 00:00:00 | ****PROVISO**** | | | SEPARATE PERMIT FOR 2 BUTT GLASS | | | OPENINGS 36X47 & 53X95 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-06-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-13 |
Time |
18:29 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-06-13 |
Time |
17:24 |
Sent To |
P |
|
| Notes |
| 2005-06-13 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE GROUND FLOOR ENGINEERING | | | CALCULATIONS FOR SOME OF THE BEAMS SAY | | | "NO GOOD" INSTEAD OF "OK".IT APPEARS | | | THAT THOSE ITEMS ARE NOT OK.PLEASE | | | ADDRESS. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.)SEE THE PREVIOUS LIST, ITEM 5C. | | | THE DESIGN PRESSURE FOR THE 36X47 AND | | | 53X95 BUTT GLASS OPENINGS IS +31/-41 ON | | | SHEET A2.THE ENGINEERING HAS A DESIGN | | | PRESSURE LIMITATION OF +30.1/-32.8. | | | | | | 4.)PROVIDE TWO COPIES OF THE MULLION | | | PRODUCT APPROVALS.ONLY ONE COPY WAS IN | | | THE PACKAGE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-05-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-05-06 |
Time |
14:42 |
Rev Time |
4.00 |
| Received By |
jgomez |
Date |
2005-05-06 |
Time |
14:42 |
Sent To |
E |
|
| Notes |
| 2005-05-06 00:00:00 | BUILDING REVIEW 2ND CHECKLIST: | | | 1- PAY IMPACT FEES. BRING BACK STAMPED | | | DRAWINGS AND PAID RECEIPT. | | | | | | 2- PROVIDE RE-RECORDED NOTICE OF | | | COMMENCEMENT. (IT'S EXPIRED). | | | | | | 3- GROUND FLOOR ENGINEERING CALCULATIONS | | | CAN'T BE ACCEPTED BECAUSE PROGRAM SHOWS | | | THAT CALCULATIONS ARE DONE USING ASCE | | | 7-02. EDITION ADOPTED BY FBC 2001 IS | | | ASCE 7-98. SEE CHAPTER 35 FBC 2001. | | | | | | 4- UPDATE TRUSS ANCHOR SCHEDULE. SEE | | | LATEST CATALOGUE WHICH WAS REVISED TO | | | COMPLY WITH SEC. 1609.4.3 FBC 2001. | | | CONNECTOR HTA16 WAS REVISED TO USE 10 | | | NAILS. ADDING MORE NAILS WILL NOT | | | INCREASE THE UPLIFT CAPACITY OF THE | | | CONNECTOR. REVISE AS REQUIRED. | | | | | | 5- BUTT GLAZING SYSTEM: | | | A) THERE ARE 2 ASSEMBLIES SYSTEMS SHOWN | | | ON PLANS. ONLY ONE SUBMITTED AND IT | | | DOESN'T MATCH PLANS. | | | | | | B) NEED COMPLETE ENGINEERING ANALYSIS, | | | DRAWINGS AND CALCULATIONS. SEE SECTION | | | 2406.2 FBC 2001. | | | **NOTE: DADE COUNTY NOA SUBMITTED CANN'T | | | BE USED BECAUSE THE INSTALLATION IS NOT | | | THE SAME AS APPROVED ON SUCH NOA. | | | ENGINEER NEEDS TO PRODUCE COMPLETE SET | | | OF DRAWINGS WITH COMPLETE SPECIFICATIONS | | | FOR ASSEMBLIES SHOWN ON PLANS. | | | | | | C) DESIGN PRESSURES DON'T MEET THE | | | DESIGN PRESSURES CALCULATED ON PLANS. | | | | | | D) SIZE OF ASSEMBLY TESTED IS SMALLER | | | THAN THOSE SHOWN ON PLANS. THEREFORE, IT | | | DOESN'T COVER THEM. | | | | | | 6- PROVIDE FLORIDA PRODUCT APPROVAL | | | COVER PAGE FOR THE FOLLOWING USP | | | CONNECTORS: UMH358 AND TDX8. | | | | | | 7- SHUTTERS DRAWINGS NEED TO BE SIGNED | | | AND SEALED BY THE ENGINEER AS REQUIRED | | | BY HIM ON GENERAL NOTE #11(E). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-13 |
Time |
17:41 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2005-04-13 |
Time |
17:40 |
Sent To |
PC |
|
| Notes |
| 2005-04-13 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- PAY IMPACT FEES. BRING BACK STAMPED | | | DRAWINGS AND PAID RECEIPT. | | | | | | 2- NOTICE OF COMMENCEMENT IS EXPIRED | | | AFTER 90 DAYS. NEED RE-RECORDED ONE. | | | | | | 3- PROVIDE ENGINEERING CALCULATIONS FOR | | | DESIGN PRESSURES AT ALL EXTERIOR | | | OPENINGS SHOWING HOW PRESSURES GIVEN ON | | | WINDOW AND DOOR SCHEDULES WERE OBTAINED. | | | SEE TABLES 1606.2B AND 1606.2E FBC 2001. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | | | 4- A) GROUNDFLOOR ENGINEERING LETTER | | | SAYS THAT STRUCTURE WAS REVIEWED FOR | | | 140MPH DESIGN SPEED ANDEXPOSURE C. | | | DESIGN PRESSURES CALCULATED ON PLANS DO | | | NOT CORRESPOND TO EXPOSURE C CATEGORY. | | | REVISE AS REQUIRED AND PROVIDE DESIGN | | | PRESSURES CALCULATIONS. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | B) GROUND FLOOR ENGINEERING LETTER SAYS | | | THAT HE IS THE ENGINEER OF RECORD. | | | ENGINEER OF RECORD IS THE ONE WHO SEALS | | | THE DRAWINGS AND SPECS. SEE CHAPTER 471 | | | FLORIDA STATUTES AND FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.002 WHEN | | | SUBMITTING DOCUMENTS FOR PUBLIC RECORD | | | AND PROVIDE HIS INFORMATION ACCORDINGLY. | | | | | | 5- A) UPDATE TRUSS ANCHOR SCHEDULE. SEE | | | LATEST CATALOGUE THAT WAS UPDATED TO | | | COMPLY WITH SEC. 1609.4.3 FBC 2001. | | | OTHERWISE, PROVIDE COMPLETE ENGINEERING | | | ANALYSIS AND CALCS THAT COMPLY WITH SEC. | | | 1609.4.3 FBC FOR TYPE AND NUMBER OF | | | FASTENERS THAT DIFFER FROM THOSE TESTED | | | AND PUBLISHED BY THE MANUFACTURER. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | | | B) USP RT20T CONNECTOR RESISTS NOT | | | LATERAL LOADS. HOW IS THE TRUSS | | | SUPPORTED TO RESIST LATERAL LOADS?. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | C) USP USC64 DON'T RESIST THE LOADS | | | CALCULATED ON GIRDER TRUSS AT MASTER | | | BEDROOM. SEE COMMENTS ON PLANS AND | | | RETURN REVIEWED SET AFTER CHANGES ARE | | | DONE TO ORIGINAL DRAWINGS TO EXPEDITE | | | REVIEW. | | | | | | D) SPECIFY TRUSS CONNECTOR FOR TRUSSES | | | BETWEEN COVERED PATIO AND LIVING ROOM. | | | SEE PLANS FOR COMMENTS. | | | | | | E) USP UMH358 DOESN'T WORK FOR 4 PLY | | | MIN. GIRDER TRUSS SPECIFIED ON ROOF | | | FRAMING PLAN. REVISE AS REQUIRED. | | | | | | 6- PROVIDE BBQ LISTING AND SPECS SEC. | | | 2808 FBC 2001. | | | **NOTE; BBQ SPECS SAY THAT BBQ ARE | | | DESIGNED FOR OUTDOOR USE ONLY. NEED | | | MANUFATURER SPECIFICATIONS CERTIFYING | | | THAT BBQ GRILLS ARE SAFE TO BE INSTALLED | | | IN THE PORCH. | | | | | | 7- BUTT GLAZING ASSEMBLIES: A) PROVIDE | | | COMPLETE ENGINEERING ANALYSIS AND | | | CALCULATIONS REQUIRED BY SEC. 2406.2 FBC | | | 2001. INCLUDING GLASS THICKNESS. | | | **NOTE: DADE COUNTY NOA'S CANN'T BE USED | | | IF THEY ARE ALTERED. | | | | | | B) THERE ARE TWO DIFFERENT BUTT GLAZING | | | ASSEMBLIES. SEE PLANS. NEED ANALYSIS FOR | | | BOTH ASSEMBLIES. | | | | | | C) PROVIDE CALCULATIONS FOR DESIGN | | | PRESSURESAT OPENINGS WERE ASSEMBLIES | | | ARE GOING TO BE INSTALLED. THIS IS PART | | | OF THE ENGINEERING ANALYSIS FOR SITE | | | SPECIFIC APPLICATIONS. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | | | | 8- ROOF TILE: PROVIDE REPORT THAT WAS | | | SUBMITTED FOR FLORIDA PRODUCT APPROVAL. | | | SBCCI REPORT, NOT DADE COUNTY NOA. | | | | | | 9- PROVIDE FLORIDA PRODUCT APPROVAL OR | | | APPLY FOR LOCAL PRODUCT APPROVAL FOR ALL | | | CONNECTORS SPECIFIED ON THE TRUSS ANCHOR | | | SCHEDULE. | | | | | | 10- STORM SHUTTERS: A) DADE COUNTY NOA | | | SUBMITTED IS EXPIRED. | | | | | | B) GENERAL NOTE 11(E) REQUIRES DRAWINGS | | | TO BE SIGNED AND SEALED BY THE ENGINEER. | | | | | | 11- FLORIDA PRODUCT APPROVAL FOR FIXED | | | WINDOWS IS NOT LEGIBLE. | | | | | | 12- MULLIONS: CLEARLY INDICATE ON | | | DRAWINGS SPECIFIC MULLION SIZE AND | | | ANCHORING TO VERIFY ADEQUACY ACCORDING | | | TO THE CALCULATED DESIGN PRESSURES. | | | **NOTE: PAY ATTENTION TO LARGE AREAS | | | LIKE FAMILY ROOM AND DINING ROOM | | | ASSEMBLIES. SECTION 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. SEE PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-03 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-02 |
Time |
19:06 |
Sent To |
PC |
|
| Notes |
| 2006-05-03 00:00:00 | *** REDLINED PLANS *** | | | | | | | | | REVISED PLANS AFTER ROUGH INSPECTION, | | | MAY REQUIRE NEW ROUGH INSPECTIONS FOR | | | ITEMS CHANGED, ADDED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-12-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-21 |
Time |
20:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-21 |
Time |
20:05 |
Sent To |
PC |
|
| Notes |
| 2005-12-21 00:00:00 | ***** UNSAT ***** | | | | | | 1)NOTE: PLEASE SEE THE 1-POLE 20A | | | CIRCUIT FOR THE POOL LTS EXCEED THE MAX | | | PF 1920VA PERMITTED ON A 20A CIRCUIT. | | | PLEASE VERIFY LOAD. | | | 240.4, 310.16 | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPT FOR 2' | | | OF WALL SPACE IN KITCHEN. 210.52 | | | | | | 3)NOTE: PLEASE CORRELATE THE NUMBER OF | | | RECESSED LTS ON PLANS WITH THAT SHOWN ON | | | PANEL SCHEDULE AND ADJUST LOADS AS | | | NEEDED. | | | 220.4B3 | | | | | | 4)NOTE: PLEASE SEE NEW INSTA-HOT | | | INDICATED ON PLANS, BUT NOT ON PANEL | | | SCHEDULE OR LOAD CALCS. | | | PLEASE ADJUST. | | | 215.5 | | | | | | 5)NOTE: PLEASE SEE LT FIXTURE IN BEDRM | | | CLOSET #4, THIS SEEMS TO BE TOO CLOSE TO | | | SHELVING PER 410.8 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASEDO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-05-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-09 |
Time |
15:26 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-05-09 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-22 |
Time |
13:25 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-03-22 |
Time |
13:25 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2006-05-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-01 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-01 |
Time |
08:49 |
Sent To |
E |
|
| Notes |
| 2006-05-01 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2006-01-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-11 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-11 |
Time |
09:09 |
Sent To |
P |
|
| Notes |
| 2006-01-11 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-01-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-05 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-05 |
Time |
14:07 |
Sent To |
E |
|
| Notes |
| 2006-01-05 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-15 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-15 |
Time |
16:09 |
Sent To |
E |
|
| Notes |
| 2005-12-15 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2005-10-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-12 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-12 |
Time |
10:39 |
Sent To |
B |
|
| Notes |
| 2005-10-12 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-04 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-04 |
Time |
10:07 |
Sent To |
B |
|
| Notes |
| 2005-10-04 00:00:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-21 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-21 |
Time |
15:37 |
Sent To |
B |
|
| Notes |
| 2005-09-21 00:00:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-13 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-13 |
Time |
15:49 |
Sent To |
B |
|
| Notes |
| 2005-07-13 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-23 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-23 |
Time |
11:10 |
Sent To |
B |
|
| Notes |
| 2005-06-23 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-21 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-21 |
Time |
15:31 |
Sent To |
B |
|
| Notes |
| 2005-06-21 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-08 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-08 |
Time |
09:51 |
Sent To |
B |
|
| Notes |
| 2005-06-08 00:00:00 | TO 'JG' DESSK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-01 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-01 |
Time |
13:51 |
Sent To |
B |
|
| Notes |
| 2005-06-02 00:00:00 | PLANS GIVEN BACK TO NAT (INCORRECT | | | PAPERWORK SUBMITTED) OK PER DEAN | | 2005-06-01 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-29 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-29 |
Time |
14:00 |
Sent To |
B |
|
| Notes |
| 2005-04-29 00:00:00 | TO "JGOMEZ" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-22 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-22 |
Time |
08:30 |
Sent To |
E |
|
| Notes |
| 2005-03-22 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-15 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2005-03-18 |
Time |
08:58 |
Sent To |
PC |
|
| Notes |
| 2005-03-18 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-03-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-03-22 |
Time |
16:20 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-20 |
Time |
17:02 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-06-20 |
Time |
17:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-03-22 |
Time |
18:12 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-03-22 |
Time |
18:12 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-21 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-21 |
Time |
15:08 |
Sent To |
I |
|
| Notes |
| 2005-03-21 00:00:00 | APPROVING SURVEY MEETING SETBACKS. | | | NOTE: SITE PLAN & SURVEY SETBACKS ARE | | | SHOWN DIFFERENTLY WITH SETBACKS. |
|
|