| Plan Review Stops For Permit 05030813 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-06-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-02 |
Time |
12:53 |
Rev Time |
1.10 |
| Received By |
jwitmer |
Date |
2005-06-02 |
Time |
12:38 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-05-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-05-02 |
Time |
17:10 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-05-02 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2005-05-02 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05030813 | | | ADD: 1675 PALM BEACH LAKES BLVD | | | 1ST FL LOBBY | | | CONT:MJS CONSTRUCTION | | | TEL: (561)###-#### | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | ) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3)TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-04-13 |
Time |
10:00 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-04-13 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2005-04-13 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05030813 | | | ADD: 1675 PALM BEACH LAKES BLVD | | | 1ST FL LOBBY | | | CONT:MJS CONSTRUCTION | | | TEL: (561)###-#### | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) 1016.1.1 MISSING THE EXIT SIGN FOR | | | THE STAIR TOWER THAT LEADS DIRECTLY | | | OUTSIDE. SEE E.1 | | | | | | 2) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3)TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-10 |
Time |
14:22 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-05-10 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2005-05-10 00:00:00 | NEW SHEET E-1 ADDED INTO SETS., |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-03-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-16 |
Time |
13:53 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-03-16 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-05-16 |
Time |
20:03 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-10 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-04-05 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-04-05 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-04-05 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2005-04-05 00:00:00 | 1) ALL EXIT DOORS THAT LEAVE THE | | | CORRIDOR ARE REQUIRED TO SWING IN THE | | | DIRECTION OF TRAVEL. PLANS SHOW SOME OF | | | THE EXIT DOORS SWINGING INTO THE | | | CORRIDOR. | | | | | | 2) ILLUMINATED EXIT SIGNS ARE REQUIRED | | | ABOVE EVERY DOOR THAT SERVES AS AN EXIT. | | | | | | 3) PLANS DON'T SHOW ANY EMERGENCY | | | LIGHTING. PLEASE INDICATE THE LOCATIONS | | | OF EMERGENCY LIGHTS. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE ALARM AND FIRE | | | SPRINKLER REMODELS. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 OR 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
16:22 |
Sent To |
B |
|
| Notes |
| 2005-05-24 00:00:00 | TO "JWITMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-04-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-26 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-26 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2005-04-26 00:00:00 | TO "COMM" BD#14 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-05-18 |
Time |
06:27 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-03-15 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2005-03-15 00:00:00 | TO "COMM BD#51" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-05-16 |
Time |
20:02 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2005-05-16 |
Time |
20:02 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-04-12 |
Time |
08:11 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-04-12 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2005-04-12 00:00:00 | DENIED: | | | PLAN SHEET M1 INDICATES THE SUPPLY | | | DIFFUSER WILL BE DIRECTED AWAY FROM THE | | | SMOKE DETECTOR.IN ACCORDANCE WITH NFPA | | | 72 AND NFPA 101, SMOKE DETECTORS ARE TO | | | BE INSTALLED IN ACCORDANCE TO THE | | | MANUFACTURERS SPECIFICATIONS AND NOT | | | LOCATED WITHIN 3 FT OF THE SUPPLY AND 5 | | | FT FROM A RETURN.SMOKE DETECTOR | | | SPACINGSHALL BE BASED ON TABLE | | | 2-3.6.6.2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-25 |
Time |
17:33 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2005-03-25 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2005-03-25 00:00:00 | NO PLUMBING PLANS SUBMITTED OR PLUBMING | | | WORK SHOWN. |
|
|