Plan Review Details - Permit 05030493
Plan Review Stops For Permit 05030493
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-06-11 Cont ID  
Sent By shill Date 2005-06-11 Time 12:25 Rev Time 0.50
Received By shill Date 2005-06-11 Time 12:25 Sent To P
Notes
2005-06-11 00:00:00TO PS DESK (TAKEN OFF OF BOARD)

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-05-05 Cont ID  
Sent By shill Date 2005-05-05 Time 16:27 Rev Time 0.50
Received By shill Date 2005-05-05 Time 16:27 Sent To PC
Notes
2005-05-05 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC.
  
 2.)THIS PERMIT CANNOT BE ISSUED UNTIL
 THE ALARM FEES ARE PAID.SEE EPHRAIM
 GARCED, FINANCE, 561-822-1311.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-03-29 Cont ID  
Sent By shill Date 2005-03-29 Time 11:16 Rev Time 1.00
Received By shill Date 2005-03-29 Time 11:16 Sent To  
Notes
2005-03-29 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.) A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED, FS713.13.
  
 2.)CONTACT EPHRAIM GARCED, FINANCE,
 561-822-1311 IN REGARDS TO HOLDS ON THIS
 PROPERTY.A PERMIT CANNOT BE RELEASED
 UNTIL THE FEES HAVE BEEN RESOLVED.
  
 3.)DOCUMENTS PREPARED BY AN ENGINEER
 ARE TO BE SIGNED, SEALED AND DATED,
 FS61G15-23.002 (ENERGY CALC).
  
 4.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC.
  
 5.)PROVIDE KNEE CLEARANCE BENEATH THE
 LOUNGE SINK, FBC11-4.24.3.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-04-18 Cont ID  
Sent By dpalmer Date 2005-04-18 Time 16:09 Rev Time 0.30
Received By dpalmer Date 2005-04-18 Time 16:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-03-14 Cont ID  
Sent By dpalmer Date 2005-03-14 Time 16:27 Rev Time 0.30
Received By dpalmer Date 2005-03-14 Time 16:27 Sent To  
Notes
2005-03-14 00:00:00******** UNSAT ********
  
 1)NOTE: PLEASE INCLUDE LOAD ON EXISTING
 GUTTER OR MAIN FOR 2ND FLR.RISER DOES
 NOT INDICATE ANY TYP OF DISC FROM
 BUS-DUCT RISER TO 2ND FLR ELECTRICAL RM
 GUTTER.
 PLEASE ALSO INCLUDE CONDUCTORS SIZES FOR
 GUTTER FEED.
 215.5
  
 2)NOTE: PLAN NOTE MENTIONS LOCATION OF
 TRANSFORMER TO BE ABOVE CEILING,PLEASE
 SHOW ON PLANS LOCATION OF TRNASFORMER.
 215.5/450.13,450.21 ETC.
 DIRECTLY ABOVE PANELS?
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-04-19 Cont ID  
Sent By mwennerg Date 2005-04-19 Time 09:28 Rev Time 0.00
Received By mwennerg Date 2005-04-19 Time 09:28 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-03-28 Cont ID  
Sent By mwennerg Date 2005-03-28 Time 13:44 Rev Time 0.00
Received By mwennerg Date 2005-03-28 Time 13:44 Sent To  
Notes
2005-03-28 00:00:00PASSED
  
 1) PLEASE BE ADVISED THAT ANY NEW DUCT
 SMOKE DETECTOR INSTALLATIONS SHALL IN
 ADDITION TO PROVIDING FAN SHUT DOWN, BE
 WIRED INTO THE FIRE ALARM SYSTEM TO
 CAUSE A GENERAL FIRE ALARM WHEN
 ACTIVATED.
  
  
 MIKE WENNERGREN, A/CAPTAIN
 WPBFR(561) 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-05-19 Cont ID  
Sent By adarroug Date 2005-05-19 Time 11:18 Rev Time 0.00
Received By adarroug Date 2005-05-19 Time 11:18 Sent To  
Notes
2005-05-19 00:00:00IN INCOMING AWAITING SPACE ON "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-04-11 Cont ID  
Sent By adarroug Date 2005-04-11 Time 14:59 Rev Time 0.00
Received By adarroug Date 2005-04-11 Time 14:59 Sent To  
Notes
2005-04-11 00:00:00TO "COMM" BD#9

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-04-04 Cont ID  
Sent By adarroug Date 2005-04-02 Time 09:26 Rev Time 0.00
Received By adarroug Date 2005-03-14 Time 08:15 Sent To  
Notes
2005-03-14 00:00:00TO "COMM" BD#35

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2005-04-02 Time   Rev Time 0.00
Received By hmoser Date 2005-04-02 Time 13:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-06-11 Cont ID  
Sent By pschmitz Date 2005-06-11 Time 13:25 Rev Time 0.00
Received By pschmitz Date 2005-06-11 Time 13:25 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-04-26 Cont ID  
Sent By kstevens Date 2005-04-26 Time 08:23 Rev Time 1.00
Received By kstevens Date 2005-04-26 Time 08:23 Sent To  
Notes
2005-04-26 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 FROM PREVIOUS REVIEW:
 3) SHT A-4 DETAIL SHOW SINK DEPTH PER
 SECTION 11-4.24.4 AND FAUCET
 REQUIREMENTS PER SECTION 11-4.24.7
 ****NEW COMMENTS****
 1B) SHTS P-1 & P-3 SANT. DOES NOT MEET
 CODE REQUIREMENTS:
 A) DENTAL SINKS AND MIXING ROOM SINK
 SHALL NOT DRAIN INTO THE WET-VENT FOR
 THE TOILET ROOMS. SECTION 909.1 - SEE
 RED LINE CORRECTIONS ON ONE SET OF PLANS
 FOR THE FLAT LAYOUT AND THE SANT. RISER
 DIAGRAM.
 2) SHT P-2 FULL OPEN VALVES REQUIRED ON
 ALL DOWN FEED WATER LINES. SECTION
 606.1(4).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-03-24 Cont ID  
Sent By kstevens Date 2005-03-24 Time 16:39 Rev Time 1.20
Received By kstevens Date 2005-03-24 Time 16:39 Sent To  
Notes
2005-03-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1) SHT A-1 CODE REFERENCED IS THE 1994
 STANDARD PLUMBING CODE. CODE ADOPTED IS
 THE FBC-2001. PLEASE INDICATE ON PLANS.
 SECTION 104.2.1.
 2) SHT A-3 DETAIL 8 SHOW CLEAR FLOOR
 SPACE FOR W/C 11-4.16.3, FLUSH CONTROLS
 11-4.16.5. FOR THE LAV SHOW FAUCETS
 11-4.19.5.
 3) SHT A-4 DETAIL 4 SHOW KNEE CLEARANCE
 11-4.24.3, SINK DEPTH 11-4.24.4, CLEAR
 FLOOR SPACE 11-4.24.5 WHICH SHALL BE
 PROVIDEDIN FRONT OF A SINK TO ALLOW
 FORWARD APPROACH WHICH SHALL EXTEND A
 MAXIMUM OF 19" UNDERNEATH THE SINK,
 EXPOSED PIPES & SURFACES 11-4.24.6,
 FAUCETS 11-4.24.7.
 4) SUBMIT A SANITARY RISER DIAGRAM
 SHOWING ALL PIPE SIZES, VENTS, & TRAPS.
 SECTION 104.3.1.1.
 5) SUBMIT A WATER RISER DIAGRAM SHOWING
 ALL PIPE SIZES, VALVES, WATER HAMMER
 ARRESTORS (IF REQUIRED BY 604.9) AND
 POINT OF CONNECTION. SECTION 104.3.1.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]