| Plan Review Stops For Permit 05030373 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-05-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-05-12 |
Time |
19:58 |
Rev Time |
0.75 |
| Received By |
shill |
Date |
2005-05-12 |
Time |
19:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-25 |
Time |
09:41 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-03-25 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2005-03-25 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PROVIDE ACCESSIBILITY DETAILS FOR | | | THE ACCESSIBLE BATHROOM STALL.IN | | | ADDITION TO INFORMATION REQUESTED BY | | | PLUMBING, ALSO PROVIDE GRAB BAR | | | INFORMATION FOR ACCESSIBLE STALL | | | FBC11-4.17.6. | | | | | | 2.)PROVIDE INFORMATION (SIDE VIEW WITH | | | DIMENSIONS, LEVERS, CLEAR FLOOR SPACE) | | | FOR THE SINK IN THE BREAK ROOM | | | FBC11-4.24. | | | | | | 3.)SHOW FIREBLOCKING FOR SOFFIT WHERE | | | THE HORIZONTAL MEETS VERTICAL, 9-A4, | | | FBC705.3. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-10 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-03-10 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-05-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-05-12 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-12 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-03-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-30 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-30 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2005-03-30 00:00:00 | 1) THE CITY OF WEST PALM BEACH REQUIRES | | | THE DUCT SMOKE DETECTORS TO BE WIRED | | | INTO THE FIRE ALARM SYSTEM TO CAUSE A | | | GENERAL FIRE ALARM UPON ACTIVATION. NOTE | | | FA0.1 #17. | | | | | | 2) FIRE EXTINGUISHERS SIZED 2A-10B-C ARE | | | REQUIRED NOT TO EXCEED A TRAVEL DISTANCE | | | OF 75 FEET. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN WPBFR(561) | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-15 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-15 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2005-04-15 00:00:00 | TO "COMM" BD#55 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-04-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-02 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-07 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2005-03-10 00:00:00 | TO "COMM" BD#8 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-04-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-04-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-04-02 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-05-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-23 |
Time |
07:48 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-05-23 |
Time |
07:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-22 |
Time |
08:37 |
Rev Time |
0.54 |
| Received By |
kstevens |
Date |
2005-03-22 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2005-03-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-3 ACCESSIBLE SINKS. THE | | | FOLLOWING INFORMATION IS REQUIRED ON THE | | | SINK DETAILS: | | | A) SINK DEPTH 11-4.24.4 | | | B) CLEAR FLOOR SPACE 11-4.24.5 - SHALL | | | BE FORWARD APPROACH, MAXIMUM 19" | | | UNDERNEATH THE SINK. | | | C) PROVIDE CROSS SECTIONAL VIEW OF THE | | | PLAM. APRON TO SHOW COMPLIANCE WITH | | | FIGURE 31 CLEARANCES. | | | D) FAUCETS 11-4.24.7 | | | 2) SHT P0.1 WATER ISOMETRICS, THE WATER | | | HAMMER ARRESTORS SHALL BE LOCATED NEAR | | | THE FIXTURES IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING AS SHOWN. (SEE PLUMBING | | | NOTE #13) | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|