| Plan Review Stops For Permit 05030357 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-08-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-22 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-08-22 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2005-08-22 00:00:00 | DOOR PRODUCT APPROVAL (LOCAL PA, NO | | | EXPIRATION) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-22 |
Time |
14:54 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-07-22 |
Time |
14:54 |
Sent To |
PC |
|
| Notes |
| 2005-07-22 00:00:00 | ***PROVISO*** | | | SEPARATE PERMIT DOOR | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-12 |
Time |
12:00 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-07-12 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)1-AMS31, FOUNDATION DOES NOT MEET | | | THE MINIMUM DEPTH RECOMMENDATION ON THE | | | SOILS REPORT (18" BELOW GRADE). | | | | | | 2.)THE PRODUCT APPROVAL APPEAR CODE | | | COMPLIANT.HOWEVE, THEY HAVE DATE | | | STAMPS ON THEM.PLEASE PROVIDE CLEAN | | | COPIES FOR STAMPING. | | | | | | 3.)THE THERMA-TRU DOOR LOCAL PRODUCT | | | APPROVAL IS EXPIRED.FLORIDA STATE OR | | | LOCAL PRODUCT APPROVAL REQUIRED, | | | FAC9B72. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-22 |
Time |
14:04 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-03-22 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2005-03-22 00:00:00 | PERMIT #05030357 | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.) A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.) AM31 DECLARES TYPE IV CONSTRUCTION, | | | PLANS SHOW WOOD TRUSSES, FBC606. | | | | | | 3.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVALS REQUIRED, FAC9B72.ANY | | | PRODUCT APPROVALS NOT APPROVED PRIOR TO | | | PERMIT ISSUANCE WILL REQUIRE SEPARATE | | | PERMITS FOR THOSE ITEMS. | | | ROOF TILE | | | OH DOORS | | | EXTERIOR SWING DOOR | | | WINDOW | | | IMPACT PROTECTION | | | | | | 4.)IF THE WINDOWS ARE NON IMPACT, A | | | HURRICANE PROTECTION INSTALLATION PLAN | | | MUST BE APPROVED BY THE BUILDING | | | OFFICIAL PRIOR TO PERMIT ISSUANCE.IF A | | | PLAN FOR THIS PROJECT HAS ALREADY BEEN | | | APPROVED, PLEASE PROVIDE A COPY. | | | | | | 5.)DOOR NOTE 1 (AM31) REFERS TO THE | | | WRONG BUILDING CODE. | | | | | | 6.)THE ROOF PLAN AMS-31 SHOWS | | | INCORRECT ZONE DESIGNATION ON THE GABLE | | | EDGE.THIS IS NOTED CORRECTLY ON AM31 | | | ROOF FASTENING ZONES, BUT PLEASE NOTE | | | THAT THERE AREN'T ANY GABLES ON THIS | | | PLAN. | | | | | | 7.)ADDITIONAL FEES DUE (RADON), SEE | | | ATTACHED. | | | | | | 8.)PROVIDE ELEVATIONS SHOWING THE | | | ACCESSIBLE ROUTE (SLOPE AND CROSS SLOPE | | | OF SIDEWALK, FBC CHAPTER 11).THIS MAY | | | BE NOTED ON THE SITE PLAN. | | | | | | 9.)PROVIDE A SOILS INVESTIGATION | | | REPORT. | | | | | | 10.) PROVIDE A SURVEY FOR THIS PROPERTY. | | | | | | 11.) NOTE - IMPACT FEE REVIEW NOT | | | REQUIRED AS PER MICHELLE, PALM BEACH | | | COUNTY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-30 |
Time |
10:36 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-06-30 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-10 |
Time |
16:11 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-03-10 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2005-03-10 00:00:00 | ********** UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002 AND | | | 61G1-16.004 FOR INFORMATION REQUIRED ON | | | TITLE BLOCKS. | | | PLEASE SEE TITLE BLOCK CONTAINS GEORGE | | | TSENG AND PLANS ARE SIGNED AND SEALED BY | | | SOMEONE ELSE. | | | PLEASE SEE THIS IS REQUIRED OF ALL | | | TRADES AND FOR ALL TRADES WHEATHER OR | | | NOT COMMENT IS MADE BY OTHER | | | REVIEWER(S). | | | PLEASE ADJUST. | | | | | | 2)NOTE: PLEASE PLACE NOTE ON PLANS FOR | | | INTENDED USE OF "MAINT GARAGE". | | | PLEASE SEE 511.1 FOR SCOPE OF WORK TO BE | | | DONE IN GARAGE. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-15 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-15 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-04-04 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-04-04 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-04-04 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2005-04-04 00:00:00 | 1) AN ADRESS NUMBER IS REQUIRED AT LEAST | | | 6" IN HEIGHT AND CONTRASTING TO THE | | | BACKGROUND. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-21 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-21 |
Time |
15:58 |
Sent To |
B |
|
| Notes |
| 2005-07-21 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-20 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-20 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2005-06-23 00:00:00 | TO "COMM" BD#16 | | 2005-06-20 00:00:00 | WAITING FOR COMM BOARD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-04-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-04-06 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-03-09 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2005-03-09 00:00:00 | TO "COMM" BD#54 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-07-18 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-07-18 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-04-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-04-06 |
Time |
06:57 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-04-06 |
Time |
06:47 |
Sent To |
|
|
| Notes |
| 2005-04-06 00:00:00 | DENIED: | | | 1.PROVIDE INFORMATION AS TO WHAT TYPE | | | OF MAINTENANCE WILL BE DONE ON THE | | | VEHICLES.PER 2001 FBC/M 502.11, AREAS | | | IN WHICH STATIONARY MOTOR VEHICLES ARE | | | OPERATED SHALL BE PROVIDED WITH A SOURCE | | | CAPTURE SYSTEM THAT CONNECTS DIRECTLY TO | | | THE MOTOR VEHICLE EXHAUST SYSTEM. | | | | | | 2.PROVIDE ELEVATION OF THE EF-A, | | | PLEASE NOTE, EXHAUST SHALL BE LOCATED AS | | | NOT TO RECIRCULATE NOXIOUS FUMES BACK | | | INTO THE GARAGE AREA THROUGH THE OPEN | | | GARAGE DOORS. | | | | | | 3.PLEASE SHOW CALCULATION FOR 1.5 | | | CFM/SQ FT. | | | | | | 4.SEE ALSO COMMENT #1 BY DEWEY PALMER | | | ELECTRICAL PLAN REVIEW, REGARDING | | | SIGNATURE & TITLE BLOCK. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-07-14 |
Time |
09:28 |
Rev Time |
0.65 |
| Received By |
kstevens |
Date |
2005-07-14 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-21 |
Time |
18:21 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-03-21 |
Time |
18:21 |
Sent To |
|
|
| Notes |
| 2005-03-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) ARCHITECT SHALL PROVIDE THE FOLLOWING | | | INFORMATION ON EACH ARCHITECTURAL SHEET. | | | A) FIRM NAME, ADDRESS, & PHONE NUMBER. | | | FAC 61G1-16.004(1) & FS 481.2055 | | | 2) P, M, & E SHEETS SHOW GEORGE S | | | TSENG'S NAME AND PE NUMBER IN THE TITLE | | | BLOCK FOR ELMER MARMORSTEIN'S SIGNATURE | | | & SEAL. (SEE COMMENT #1) | | | 3) THE FOLLOWING INFORMATION IS REQUIRED | | | ON THE DETAIL FOR THE ACCESSIBLE TOILET | | | ROOM: | | | A) CLEAR FLOOR SPACE 11-4.16.2 | | | B) HEIGHT 11-4.16.3 | | | C) FLUSH CONTROLS 11-4.16.5 | | | D) 5' TURNING AREA 11-4.22.3 | | | 4) SHT AM-31 A DRINKING FOUNTAIN IS | | | REQUIRED PER TABLE 403.1. | | | 5) SHT PM-31 DOMESTIC WATER RISER | | | DIAGRAM: | | | A) AN RPZ BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE TO MAINT. BUILDING. | | | SECTION 608.13.2. | | | B) FULL OPEN VALVE IS REQUIRED AT THE | | | ENTRANCE TO THE STRUCTURE. SECTION | | | 606.1(2). | | | C) FULL OPEN VALVES ARE REQUIRED ON THE | | | TOP OF ALL WATER DOWN-FEED LINES. | | | SECTION 606.1(4). | | | 6) THE OIL SEPARATOR SHALL BE SIZED BY | | | RODNEY COMPO, ENVIRONMENTAL COMPLIANCE. | | | WASTE ORD. #2938-96. CONTACT MR. COMPO | | | (561) 837-4074 ORVIA E-MAIL AT | | | [email protected]. - SUBMIT THE WORKSHEET | | | FROM MR. COMPO WHEN RESUBMITTING PLANS. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-11 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-11 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2005-03-15 00:00:00 | APPROVED BY JOSH LONG, SENIOR PLANNER | | | 822-1449 |
|
|