Plan Review Details - Permit 05030252
Plan Review Stops For Permit 05030252
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2005-03-08 Cont ID  
Sent By rmcdouga Date 2005-03-08 Time 10:35 Rev Time 0.00
Received By rmcdouga Date 2005-03-08 Time 10:49 Sent To Z
Notes
2005-03-08 00:00:00SENT TO ZONING

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-03-14 Cont ID  
Sent By rmcdouga Date 2005-03-14 Time 11:44 Rev Time 0.00
Received By rmcdouga Date 2005-03-14 Time 11:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2006-05-16 Cont ID  
Sent By dpalmer Date 2006-05-16 Time 08:00 Rev Time 0.00
Received By dpalmer Date 2006-05-16 Time 08:00 Sent To PC
Notes
2006-05-16 00:00:00VIF THE GE SYSTEM FOR CODE COMPLIANCE.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-03-06 Cont ID  
Sent By dpalmer Date 2006-03-06 Time 20:51 Rev Time 0.00
Received By dpalmer Date 2006-03-06 Time 20:51 Sent To PC
Notes
2006-03-06 00:00:00REV FOR 2ND FLR ONLY.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-02-10 Cont ID  
Sent By dpalmer Date 2006-02-10 Time 20:30 Rev Time 0.00
Received By dpalmer Date 2006-02-10 Time 20:23 Sent To PC
Notes
2006-02-10 00:00:00REDLINED :
  
 GE SYSTEM TO BE INSTALLED PER 250.50,
 250.52 ,250.56, 250.66

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-01-30 Cont ID  
Sent By dpalmer Date 2006-01-30 Time 10:43 Rev Time 0.00
Received By dpalmer Date 2006-01-30 Time 10:43 Sent To PC
Notes
2006-01-30 00:00:00HIGH-LIGHTED GE SYSTEM.
 CHANGED BACK TO 2-GRND RODS, #2 AND THE
 SOLE CONNECTION BONDING FOOTER STEEL IS
 SHOWN AS #4.250.50

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-01-23 Cont ID  
Sent By dpalmer Date 2006-01-23 Time 09:42 Rev Time 0.00
Received By dpalmer Date 2006-01-23 Time 09:42 Sent To  
Notes
2006-01-23 00:00:00PLANS REDLINED.
  
  
 PLEASE SEE MIN GEC HAS NOW BEEN CHANGED
 TO A #4.
 THE GEC, SHALL BE SIZED PER 250.66, A #2
 SHALL BE INSTALLED FROM THE FOOTER
 STEEL.
  
 ** ORIG PLANS CALLED FOR 2-COPPER GRNDS
 RODS, 1/0 AWG MIN.
  
  
 250.66,250.64,250.68.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-03-14 Cont ID  
Sent By rmcdouga Date 2005-03-14 Time 11:43 Rev Time 0.00
Received By rmcdouga Date 2005-03-14 Time 11:43 Sent To  
Notes
2005-03-14 00:00:00PASSED UNDER MASTER #04041627

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2005-03-14 Cont ID  
Sent By rmcdouga Date 2005-03-14 Time 11:43 Rev Time 0.00
Received By rmcdouga Date 2005-03-14 Time 11:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-03-14 Cont ID  
Sent By rmcdouga Date 2005-03-14 Time 11:42 Rev Time 0.00
Received By rmcdouga Date 2005-03-14 Time 11:42 Sent To  
Notes
2005-03-14 00:00:00OK UNDER MASTER # 04041627

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-05-10 Cont ID  
Sent By adarroug Date 2006-05-10 Time 17:11 Rev Time 0.00
Received By adarroug Date 2006-05-10 Time 17:11 Sent To E
Notes
2006-05-10 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-03-02 Cont ID  
Sent By adarroug Date 2006-03-02 Time 18:56 Rev Time 0.00
Received By adarroug Date 2006-03-02 Time 18:56 Sent To E
Notes
2006-03-02 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-02-10 Cont ID  
Sent By adarroug Date 2006-02-10 Time 11:14 Rev Time 0.00
Received By adarroug Date 2006-02-10 Time 11:14 Sent To E
Notes
2006-02-10 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-01-22 Cont ID  
Sent By adarroug Date 2006-01-22 Time 10:55 Rev Time 0.00
Received By adarroug Date 2006-01-22 Time 10:55 Sent To E
Notes
2006-01-22 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-17 Cont ID  
Sent By adarroug Date 2006-01-17 Time 17:26 Rev Time 0.00
Received By adarroug Date 2006-01-17 Time 17:26 Sent To E
Notes
2006-01-17 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-03-10 Cont ID  
Sent By adarroug Date 2005-03-10 Time 10:53 Rev Time 0.00
Received By adarroug Date 2005-03-10 Time 10:53 Sent To B
Notes
2005-03-10 00:00:00TO "RMCDOUGAL" DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-03-08 Cont ID  
Sent By rmcdouga Date 2005-03-08 Time 10:50 Rev Time 0.00
Received By rmcdouga Date 2005-03-08 Time 10:50 Sent To  
Notes
2005-03-08 00:00:00SENT TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-03-07 Cont ID  
Sent By adarroug Date 2005-03-14 Time 11:42 Rev Time 0.00
Received By rmcdouga Date 2005-03-07 Time 08:57 Sent To B
Notes
2005-03-07 00:00:00TO RMCDOUGAL DESK

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-03-14 Cont ID  
Sent By rmcdouga Date 2005-03-14 Time 11:42 Rev Time 0.00
Received By rmcdouga Date 2005-03-14 Time 11:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-03-14 Cont ID  
Sent By rmcdouga Date 2005-03-14 Time 11:42 Rev Time 0.00
Received By rmcdouga Date 2005-03-14 Time 11:42 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-03-09 Cont ID  
Sent By mmclean Date 2005-03-09 Time 12:19 Rev Time 0.00
Received By mmclean Date 2005-03-09 Time 12:19 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved