| Plan Review Stops For Permit 05030248 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-08 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-08 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2005-03-04 00:00:00 | JOHN...PLEASE NOTE THE EXTENSION FILE | | | HAS THE OWNER INFO INCORRECT SEE | | | PRINTOUT FROM PROPERTY APPRAISER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-14 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-14 |
Time |
07:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-04-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-28 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-28 |
Time |
17:24 |
Sent To |
PC |
|
| Notes |
| 2006-04-28 00:00:00 | REDLINE GE SYSTEM |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-13 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-13 |
Time |
14:58 |
Sent To |
PC |
|
| Notes |
| 2006-04-13 00:00:00 | REDLINED 250.56 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-06 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-06 |
Time |
07:13 |
Sent To |
PC |
|
| Notes |
| 2006-04-06 00:00:00 | *********UNSAT *********** | | | | | | 1) NOTE: PLEASE SEE ALL SHEETS ARE TO BE | | | SIGNED, DATED AND SEALED BY THE | | | ARCHITECT OF RECORD. | | | FS 481.221 | | | | | | 2) NOTE: PLEASE SEE MIN GEC HAS NOW BEEN | | | CHANGED TO A #4. | | | THE GEC, SHALL BE SIZED PER 250.66, A #2 | | | SHALL BE INSTALLED FROM THE FOOTER | | | STEEL. | | | ** ORIG PLANS CALLED FOR 2-COPPER GRNDS | | | RODS, 1/0 AWG MIN. | | | 250.66,250.64,250.68. | | | PLEASE SEE THE GROUNDING ELECTRODE | | | SYSTEMS ON MANY PREVIOUS PLANS HAVE BEEN | | | REDLINED, HOWEVER PLANS NEED TO BE | | | CORRECTED AT THIS TIME FOR ALL FUTURE | | | REVISIONS. | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLANREVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-12-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-25 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-25 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-14 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-14 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2005-03-14 00:00:00 | OK UNDER MASTER #04041627 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-14 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-14 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-14 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-14 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2005-03-14 00:00:00 | OK UNDER MASTER # 04041627 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-12 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-12 |
Time |
15:45 |
Sent To |
E |
|
| Notes |
| 2006-04-12 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-05 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-05 |
Time |
11:18 |
Sent To |
E |
|
| Notes |
| 2006-04-05 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-11 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-11 |
Time |
10:01 |
Sent To |
B |
|
| Notes |
| 2005-03-11 00:00:00 | TO "RMCDOUGAL" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-08 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-08 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2005-03-08 00:00:00 | SENT TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-07 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-07 |
Time |
08:58 |
Sent To |
B |
|
| Notes |
| 2005-03-07 00:00:00 | TO RMCDOUGAL DESK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-14 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-14 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-14 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-14 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-10 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-10 |
Time |
10:57 |
Sent To |
I |
|
| Notes |
|
|