| Plan Review Stops For Permit 05030123 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-21 |
Time |
15:24 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-03-21 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-12 |
Time |
17:37 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-04-12 |
Time |
17:37 |
Sent To |
|
|
| Notes |
| 2005-04-12 00:00:00 | REDLINED PLANS. | | | | | | | | | 210.52C1-5, 210.8A6 FOR KITCHEN GFI'S | | | AND SPACING. | | | 210.52D,210.11C3,210.8 FOR BATH GFI'S, | | | MUST ALSO BE 20A AND #12. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-03-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-07 |
Time |
15:27 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-03-07 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2005-03-07 00:00:00 | ***UNSAT *** | | | | | | 1)NOTE: PLEASE PROVIDE LAYOUT OF EITHER | | | NEW OR EXISTING REQUIRED GFI RECEPTS PER | | | 210.52C1-5. | | | PLEASE ALSO SEE 210.8A6 | | | | | | 2)NOTE: PLEASE PROVIDE ADDRESS/AND UNIT | | | # ON PLANS. | | | FAC 61G1-16 | | | PLEASE ALSO PROVIDE THE PRINTED NAME OF | | | THE PERSON RESPONSIBLE FOR PLANS. | | | FBC 104.2.1 | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-04-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-04-14 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-04-14 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-03-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-31 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-31 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2005-03-31 00:00:00 | 1) PLEASE PROVIDE FURTHER INFORMATION | | | REGARDING THE FIRE SPRINKLER | | | RELOCATIONS. | | | | | | 2) SEPARATE SHOP DRAWINGS AND PERMIT IS | | | REQUIRED FOR THE FIRE SPRINKLER REMODEL. | | | | | | 3) HOW DOES THIS WORK EFFECT EXISTING | | | SMOKE DETECTORS? | | | | | | 4) ARE THERE ANY FIRE ALARM DEVICES THAT | | | WILL BE EFFECTED BY THIS WORK? | | | | | | 5) ALL CONTSRUCTION, RENOVATION AND | | | DEMOLITION SHALL BE IN ACCORDANCE WITH | | | NFPA 241. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR9561) 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-04-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-08 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-08 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2005-04-08 00:00:00 | TO "COMM" BD#17 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
|
Date |
2005-04-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-31 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-04 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2005-03-04 00:00:00 | TO "COMM" BD#58 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-22 |
Time |
07:40 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2005-03-22 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2005-03-22 00:00:00 | PLAN INDICATES REPLACING BATHROOM | | | EXHAUST FAN & MOVING EXISTING | | | THERMOSTAT.NO DUCT OR EQUIPMENT | | | CHANGES OR REPLACEMENT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-25 |
Time |
15:07 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-04-25 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2005-04-25 00:00:00 | NO PLUMBING PLANS SUBMITTED - LETTER | | | FROM ENGINEER FOR ALTERNATIVE MATERIALS | | | AND MEANS - PROVISO SHOWER HEAD 2.5 GPM | | | @ 80 PSI |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-04-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-20 |
Time |
07:39 |
Rev Time |
1.75 |
| Received By |
kstevens |
Date |
2005-04-19 |
Time |
18:47 |
Sent To |
|
|
| Notes |
| 2005-04-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | | | | 1) TWO COPIES OF THE LETTER FROM THE | | | ENGINEER CONCERNING THE DRAIN FOR THE | | | SHOWER ARE REQUIRED. FS 471.025. | | | 2) A CERTIFICATE OF AUTHORIZATION NUMBER | | | SHALL BE IN THE TITLE BLOCK REQUIRED BY | | | FAC 61G15-23.002(2) & FS 471.025. | | | 3) LETTER SHALL STATE THAT THE | | | ALTERNATIVE MATERIALS AND METHODS | | | SECTION OF THE CODE IS BEING INVOKED, | | | (SECTION 103.7.1),AND THAT THE SHOWER | | | HEAD REQUIRED BY TABLE 604.4 SHALL HAVE | | | A MAXIMUM FLOW RATE OF 2.5 GPM @ 80 PSI. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-21 |
Time |
13:54 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-03-21 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2005-03-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | | | | 1) A 2" TRAP IS REQUIRED FOR A SHOWER. | | | TUBS REQUIRE 1-1/2" AND CHANGING FROM A | | | TUB TO A SHOWER REQUIRES A 2" SANT. | | | LINE. TABLE 709.1 | | | 2) ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | SECTION 104.2.1. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|