Plan Review Details - Permit 05030016
Plan Review Stops For Permit 05030016
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-04-14 Cont ID  
Sent By lsmith Date 2005-04-14 Time 09:48 Rev Time 0.75
Received By lsmith Date 2005-04-14 Time 09:48 Sent To  
Notes
2005-04-14 00:00:00BUILDING PLAN REVIEW: PROVISO
  
 ALL OPENINGS TO THE POOL MUST COMPLY
 WITH THE POOL SAFETY ACT FBC424. ONLY
 SHOWING A DOOR ALARM.ANY WINDOWS MUST
 ALSO BE PROTECTED.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-03-16 Cont ID  
Sent By lsmith Date 2005-03-16 Time 10:49 Rev Time 0.50
Received By lsmith Date 2005-03-16 Time 10:49 Sent To  
Notes
2005-03-16 00:00:00BUILDING PLAN REVIEW FAILED
  
 1. SHOW METHOD OF COMPLIANCE OF THE
 FLORIDA POOL SAFETY ACT SEC. 424 FBC.
 PROTECTING THE POOL FROM ALL OPENINGS OF
 THE HOUSE LEADING TO THE POOL AREA.
  
 2. SHOW ANCHORING DETAIL FOR POOL
 EQUIPMENT.
  
 3. WHAT IS THE SQ. FT. OF THE DECK?
  
 4. NO PLUMBING OR ELECTRIC PERMIT
 APPLIED FOR.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-03-04 Cont ID  
Sent By btrobaug Date 2005-03-04 Time 14:55 Rev Time 0.33
Received By btrobaug Date 2005-03-04 Time 14:45 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-05-31 Cont ID  
Sent By adarroug Date 2005-05-31 Time 15:41 Rev Time 0.00
Received By adarroug Date 2005-05-31 Time 15:41 Sent To Z
Notes
2005-05-31 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-03-22 Cont ID  
Sent By adarroug Date 2005-03-22 Time 13:34 Rev Time 0.00
Received By adarroug Date 2005-03-22 Time 13:34 Sent To P
Notes
2005-03-22 00:00:00TO "KSTEVENS" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-03-04 Cont ID  
Sent By adarroug Date 2005-03-04 Time 11:00 Rev Time 0.00
Received By adarroug Date 2005-03-04 Time 11:00 Sent To E
Notes
2005-03-04 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-03-01 Cont ID  
Sent By adarroug Date 2005-03-01 Time 16:26 Rev Time 0.00
Received By adarroug Date 2005-03-01 Time 16:26 Sent To Z
Notes
2005-03-01 00:00:00TO "Z"BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-04-28 Cont ID  
Sent By kstevens Date 2005-04-28 Time 13:38 Rev Time 0.65
Received By kstevens Date 2005-04-28 Time 13:38 Sent To  
Notes
2005-04-28 00:00:00 
  
 PASSED/PROVISO
 MAIN DRAINS SHALL BE PIPED AS SHOWN ON
 THE APPROVED SWIMMING POOL MAIN DRAIN
 ATMOSPHERIC VENT ARRANGEMENT
  
  
  
 .

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-04-13 Cont ID  
Sent By kstevens Date 2005-04-13 Time 05:35 Rev Time 0.33
Received By kstevens Date 2005-04-13 Time 05:35 Sent To B
Notes
2005-04-13 00:00:00DENIED
 REFERENCE: FBC-242.2 SWIMMING POOLS
 FBC-2001 CHAPTER 1
  
 1) HAND DRAWN CHANGES TO A SIGNED/SEALED
 SET OF PLANS ARE NOT APPROVED. SECTION
 104.2.1.3. NEW SHEETS REQUIRED WITH
 CHANGES APPROVED BY ENGINEER OF RECORD.
 2) POOL ANCHORING SHEET SHALL HAVE THE
 PRINTED NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN AFFIXED TO
 SHEET. SECTION 104.2.1.
 3) 3) FBC-2001 424.2.9 WATER SUPPLY,
 LOCAL ORD. #2853-95, BACKFLOW REQUIRED
 ON WATER SERVICE. (ADD TO NOTES).
 4) FBC-2001 424.2.13.2 JOINTS AND
 CONNECTIONS, FBC PLUG SEC 605.21 PURPLE
 PRIMER REQUIRED ON PVC PIPING AND
 FITTINGS. (ADD TO NOTES).
 5) PIPING FOR THE MAIN DRAINS ON THE
 POOL LAYOUT SHEET DOES NOT REFLECT THE
 PIPING SHOWN ON THE APPROVED SWIMMING
 POOL AND WADING POOL MAIN DRAIN
 ATMOSPHERIC VENT ARRANGEMENT. THE DRAIN
 SHALL BE DRAINED SIMULTANIOUSLY AND THE
 VENT LINE SHALL BE SHOWN. SECTIONS
 104.2.1 & 424.2.6.6.4.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-03-14 Cont ID  
Sent By gsalfeld Date 2005-03-14 Time 15:03 Rev Time 1.00
Received By gsalfeld Date 2005-03-14 Time 15:03 Sent To B
Notes
2005-03-14 00:00:003/14/05 DENIED GS
  
 1-FBC 2001 424.2.6.6.2- PROVIDE MODEL
 NUMBER AND MANUFACTURE INFORMATION FOR
 VAC.LOCK.
 2-424.2.7.1- POOL CIRCULATING PUMPS
 SHALL BE EQUIPED WITH APPROVED TYPE HAIR
 AND LINT STRAINER.
 3-PUMPS AND EQUIPMENT SHALL BE MOUNTED
 ON 4" SLAB[ DETAIL ]
 4-BACKFLOW REQ. ON WATER SERVICE
 5-NO AIR TEST ON PVC PIPE OR FITTINGS
 6-FBC 104.2SHOW PIPING FOR THE ENTIRE
 SYSTEM,PIPE SIZES,VENTS,SUCTION AND
 DISCHARGE PIPING ETC.

Review Stop Z ZONING
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2005-06-03 Time   Rev Time 0.00
Received By   Date 2005-06-03 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-03-03 Cont ID  
Sent By mmclean Date 2005-03-03 Time 16:12 Rev Time 0.00
Received By mmclean Date 2005-03-03 Time 16:12 Sent To I
Notes
***NONE***