| Plan Review Stops For Permit 05030016 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-04-14 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-04-14 |
Time |
09:48 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2005-04-14 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2005-04-14 00:00:00 | BUILDING PLAN REVIEW: PROVISO | | | | | | ALL OPENINGS TO THE POOL MUST COMPLY | | | WITH THE POOL SAFETY ACT FBC424. ONLY | | | SHOWING A DOOR ALARM.ANY WINDOWS MUST | | | ALSO BE PROTECTED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-03-16 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-03-16 |
Time |
10:49 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2005-03-16 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2005-03-16 00:00:00 | BUILDING PLAN REVIEW FAILED | | | | | | 1. SHOW METHOD OF COMPLIANCE OF THE | | | FLORIDA POOL SAFETY ACT SEC. 424 FBC. | | | PROTECTING THE POOL FROM ALL OPENINGS OF | | | THE HOUSE LEADING TO THE POOL AREA. | | | | | | 2. SHOW ANCHORING DETAIL FOR POOL | | | EQUIPMENT. | | | | | | 3. WHAT IS THE SQ. FT. OF THE DECK? | | | | | | 4. NO PLUMBING OR ELECTRIC PERMIT | | | APPLIED FOR. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-03-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-03-04 |
Time |
14:55 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-03-04 |
Time |
14:45 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-05-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-31 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-31 |
Time |
15:41 |
Sent To |
Z |
|
| Notes |
| 2005-05-31 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-22 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-22 |
Time |
13:34 |
Sent To |
P |
|
| Notes |
| 2005-03-22 00:00:00 | TO "KSTEVENS" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-04 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-04 |
Time |
11:00 |
Sent To |
E |
|
| Notes |
| 2005-03-04 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-01 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-01 |
Time |
16:26 |
Sent To |
Z |
|
| Notes |
| 2005-03-01 00:00:00 | TO "Z"BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-04-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-28 |
Time |
13:38 |
Rev Time |
0.65 |
| Received By |
kstevens |
Date |
2005-04-28 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2005-04-28 00:00:00 | | | | | | | PASSED/PROVISO | | | MAIN DRAINS SHALL BE PIPED AS SHOWN ON | | | THE APPROVED SWIMMING POOL MAIN DRAIN | | | ATMOSPHERIC VENT ARRANGEMENT | | | | | | | | | | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-04-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-13 |
Time |
05:35 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-04-13 |
Time |
05:35 |
Sent To |
B |
|
| Notes |
| 2005-04-13 00:00:00 | DENIED | | | REFERENCE: FBC-242.2 SWIMMING POOLS | | | FBC-2001 CHAPTER 1 | | | | | | 1) HAND DRAWN CHANGES TO A SIGNED/SEALED | | | SET OF PLANS ARE NOT APPROVED. SECTION | | | 104.2.1.3. NEW SHEETS REQUIRED WITH | | | CHANGES APPROVED BY ENGINEER OF RECORD. | | | 2) POOL ANCHORING SHEET SHALL HAVE THE | | | PRINTED NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN AFFIXED TO | | | SHEET. SECTION 104.2.1. | | | 3) 3) FBC-2001 424.2.9 WATER SUPPLY, | | | LOCAL ORD. #2853-95, BACKFLOW REQUIRED | | | ON WATER SERVICE. (ADD TO NOTES). | | | 4) FBC-2001 424.2.13.2 JOINTS AND | | | CONNECTIONS, FBC PLUG SEC 605.21 PURPLE | | | PRIMER REQUIRED ON PVC PIPING AND | | | FITTINGS. (ADD TO NOTES). | | | 5) PIPING FOR THE MAIN DRAINS ON THE | | | POOL LAYOUT SHEET DOES NOT REFLECT THE | | | PIPING SHOWN ON THE APPROVED SWIMMING | | | POOL AND WADING POOL MAIN DRAIN | | | ATMOSPHERIC VENT ARRANGEMENT. THE DRAIN | | | SHALL BE DRAINED SIMULTANIOUSLY AND THE | | | VENT LINE SHALL BE SHOWN. SECTIONS | | | 104.2.1 & 424.2.6.6.4. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
gsalfeld |
Date |
2005-03-14 |
Time |
15:03 |
Rev Time |
1.00 |
| Received By |
gsalfeld |
Date |
2005-03-14 |
Time |
15:03 |
Sent To |
B |
|
| Notes |
| 2005-03-14 00:00:00 | 3/14/05 DENIED GS | | | | | | 1-FBC 2001 424.2.6.6.2- PROVIDE MODEL | | | NUMBER AND MANUFACTURE INFORMATION FOR | | | VAC.LOCK. | | | 2-424.2.7.1- POOL CIRCULATING PUMPS | | | SHALL BE EQUIPED WITH APPROVED TYPE HAIR | | | AND LINT STRAINER. | | | 3-PUMPS AND EQUIPMENT SHALL BE MOUNTED | | | ON 4" SLAB[ DETAIL ] | | | 4-BACKFLOW REQ. ON WATER SERVICE | | | 5-NO AIR TEST ON PVC PIPE OR FITTINGS | | | 6-FBC 104.2SHOW PIPING FOR THE ENTIRE | | | SYSTEM,PIPE SIZES,VENTS,SUCTION AND | | | DISCHARGE PIPING ETC. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-06-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2005-06-03 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-03 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-03 |
Time |
16:12 |
Sent To |
I |
|
| Notes |
|
|