Plan Review Details - Permit 05021514
Plan Review Stops For Permit 05021514
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-06-27 Cont ID  
Sent By jwitmer Date 2005-06-27 Time 17:06 Rev Time 0.88
Received By jwitmer Date 2005-06-27 Time 15:03 Sent To PC
Notes
2005-06-27 00:00:00THIS PERMIT IS FOR THE REPLACEMENT OF
 (4) OVERHEAD SITE SPECIFIC COOKSON
 OVERHEAD DOORS.JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-03-02 Cont ID  
Sent By jwitmer Date 2005-03-02 Time 14:35 Rev Time 2.22
Received By jwitmer Date 2005-03-02 Time 14:35 Sent To PC
Notes
2005-03-02 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05021514
 ADD: 1016 CLARE AVE
 CONT:J B MATHEWS CO
 TEL: (772)260-3498
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 PROVIDE THE COMPLETE 31 PAGE REPORT
 FOR THE COOKSON ROLLING DOORS.
  
 2) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 WITHIN THE REPORT SUBMITTED THERE IS A
 SHEET PROVIDING ANCHOR SPACING INTO THE
 CONCRETE. THIS PAGE IS NOT PART OF THE
 PRODUCT APPROVAL. PROVIDE WHO DESIGNED
 THIS DOCUMENT.
  
 3) FL S S 481.229(C) COMMERCIAL PROJECTS
 COSTING LESS THAN $25,000.00 DO NOT
 REQUIRE AN ARCHITECT, SINCE OVER THIS
 AMOUNT A DESIGN PROFESSIONAL SHALL BE
 REQUIRED. THEY SHALL PROVIDE THE SPACING
  
 FOR THE ANCHORS TO THE BUCK.
  
 4) PROVIDE ELEVATIONS INDICATING THE
 OPEING SIZE, POSITIVE AND NEGATIVE
 PRESSURES, AND MEAN ROOF HEIGHT OF THE
 BUILDING.
  
 5) THE DESIGN PROFESSIONAL TO INDICATE
 IF THE TRACK IS TO BE INSTALLED TO A
 WOOD BUCK OR SECURED DIRECTLY TO THE
 CONCRETE OR CMU?
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  
 2) FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 3) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2005-06-27 Cont ID  
Sent By jwitmer Date 2005-06-27 Time 15:02 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2005-06-27 Cont ID  
Sent By jwitmer Date 2005-06-27 Time 15:02 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-14 Cont ID  
Sent By mjacobs Date 2005-06-14 Time 08:29 Rev Time 0.00
Received By jwitmer Date 2005-06-27 Time 15:03 Sent To B
Notes
2005-06-14 00:00:00TO 'JW' DESK/RESUB.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-06-27 Cont ID  
Sent By jwitmer Date 2005-06-27 Time 15:03 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-06-27 Cont ID  
Sent By jwitmer Date 2005-06-27 Time 15:02 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***