Plan Review Details - Permit 05021387
| Plan Review Stops For Permit 05021387 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-08-25 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-08-25 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2006-08-25 00:00:00 | THE LOCATION OF THE STRUCTURE ON THE | | | SITE PLANS CORRESPONDS TO THIS ADDRESS: | | | 641 7TH ST ( IN THE RCORDS OF UTILITY | | | BILLING ) THE SECOND FLOOR USED FOR | | | RESIDENTIAL IS KNOWN AS 641 7TH ST AND | | | THE FIRST FLOOR IS 800 N SAPODILLA | | | AVE.NEED CLARIFICATION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-09-27 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-09-26 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2006-09-27 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | THE FOLLOWING COMMENTS ARE FROM THE | | | PREVIOUS LIST, NOT PROPERLY ADDRESSED. | | | NUMBERING HAS REMAINED THE SAME FOR | | | CONSISTENCY.NOTE THAT SOME OF THE NEW | | | COMMENTS WERE PREVIOUSLY ADDRESSED BUT | | | ARE NOT ON THIS SET OF PLANS; OLD SHEETS | | | NOT SUBMITTED: | | | | | | 1.)FROM PREVIOUS LISTS: | | | | | | THE EXTERIOR STAIR IS TO COMPLY | | | WITH FBC1006.2.4.PROVIDE ELEVATIONS | | | AND INDICATE, TO SCALE, ALL OPENINGS | | | WHICH REQUIRE FIRE RESISTANCE.SHOW ONE | | | HOUR RATING REQUIRED ON THE PLAN. | | | | | | ONE HOUR RATING REQUIREMENT NOT SHOWN. | | | YOUR RESPONSE LETTER THAT THE WALL IS | | | BLOCK AND IS 1 HOUR IS ACKNOWLEDGED BUT | | | IS TO BE SHOWN ON THE PLAN (1 HOUR | | | REQUIRED).THE OPENINGS ON THE SECOND | | | FLOOR WHICH ARE REQUIRED TO BE PROTECTED | | | ARE NOTED BUT NOTHING IS SHOWN FOR THE | | | FIRST FLOOR.PROVIDE ELEVATIONS AS | | | REQUESTED IN EACH PLAN REVIEW AND NOTE | | | THE 1 HOUR REQUIREMENT ON THE PLAN. | | | | | | 2.)ADDRESSED | | | | | | 3.)DOCUMENTS PREPARED BY AN ENGINEER | | | AND SUBMITTED FOR PUBLIC RECORD ARE TO | | | BE SIGNED, SEALED, DATED ORIGINALS | | | FAC61G15-23.002 (ENERGY CALCS). | | | | | | SIGN THE OWNER/AGENT LINE OF THE ENERGY | | | CALCS, FBC*103.1. | | | | | | 4.)SEE PREVIOUS LISTS IN REGARDS TO | | | HURRICANE SHUTTERS.THERE IS A | | | STATEMENT ON THE PLAN THAT ALL SHUTTERS | | | WILL BE ACCORDION, BUT STORM PANEL | | | PRODUCT APPROVALS WERE SUBMITTED AND A | | | STORAGE AREA SHOWN FOR THE SHUTTERS. | | | SEE THE ATTACHED WIND-BORNE DEBRIS | | | IMPACT PROTECTION STANDARD, ITEMS 13 AND | | | 14.SUBMIT AN INSTALLATION PLAN AS | | | REQUIRED.THE PLAN MAY BE SUBMITTED | | | SEPARATELY FROM THE PERMIT APPLICATION. | | | A PRELIMINARY REVIEW CAN BE DONE BY | | | EMAIL; SUBMIT TO [email protected] | | | PRELIMINARY REVIEW, THE PLAN IS | | | FORWARDED TO THE BUILDING OFFICIAL.THE | | | PLAN MUST BE APPROVED PRIOR TO PERMIT | | | ISSUANCE.CONTINUED FAILURE TO ADDRESS | | | THIS COMMENT WILL RESULT IN ADDITIONAL | | | PERMIT DELAYS. | | | | | | 5.)COMPLETE THE ATTACHED INSTALLATION | | | SCHEDULE (SHUTTERS), OR PROVIDE ALL | | | REQUIRED INFORMATION IN A SIMILAR | | | FORMAT. | | | | | | 6.)PRODUCT APPROVALS FOR JELD-WEN | | | DOORS WERE SUBMITTED.THERE ARE THREE | | | DIFFERENT PRODUCT APPROVALS IN THE | | | BROCHURE.SUBMIT ONLY THE DOOR YOU WILL | | | INSTALL. | | | | | | 7.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVALS REQUIRED IN ADDITION TO NOAS | | | SUBMITTED, FAC9B72. | | | WWW.FLORIDABUILDING.ORG | | | | | | THIS WAS ADDRESSED WITH FBC2001 PRODUCT | | | APPROVALS.NOTE THAT A NEW APPLICATION | | | WILL BE UNDER FBC2004, PROVIDE CURRENT | | | (2004) PRODUCT APPROVALS. | | | | | | FBC2004 REQUIRES THAT PRODUCT APPROVALS | | | BE REVIEWED BY DESIGNER OF RECORD, | | | FBC*106.3.3. | | | | | | 8.)SEE PREVIOUS LIST, ITEM #6. | | | PROVIDE FIRE RATING INFORMATION FOR THE | | | PRODUCT YOU ARE INSTALLING.THE PRODUCT | | | APPROVALS FOR THE DOORS DO NOT INDICATE | | | THAT THEY HAVE A FIRE RATING. | | | | | | 9.)SEE PREVIOUS LIST, ITEM #6.THE | | | ENTRY DOORS ARE TO BE APPROVED BY | | | HISTORIC PRIOR TO RESUBMITTAL AS PER | | | THEIR LETTER DATED 11/20/03, WHICH IS NO | | | LONGER IN THE PACKAGE. | | | | | | HAVE HISTORIC STAMP THE PRODUCT | | | APPROVAL.THEY HAVE STATED THAT THEY | | | DID NOT DO A REVIEW, ONLY THAT THEY | | | STAMPED THE RESUBMITTAL SHEET. | | | | | | 10.)YOU HAVE DONE A CHANGE TO THE | | | EXTERIOR OF THE BUILDING (ADDED | | | ACCORDION SHUTTERS).THIS REQUIRES | | | APPROVAL FROM HISTORIC PRESERVATION | | | DEPARTMENT. | | | | | | 11.)PRODUCT APPROVAL FOR TRACO SINGLE | | | HUNG EGRESS WINDOW WAS SUBMITTED.THIS | | | IS ACCEPTABLE FOR THE WINDOWS WHICH ARE | | | NOT REQUIRED TO BE FIRE RATED; HOWEVER, | | | FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72.PLEASE PROVIDE. | | | WWW.FLORIDABUILDING.ORG | | | | | | 12.)PROVIDE PRODUCT APPROVALS AND FIRE | | | RATING | | | INFORMATION FOR THE FIRE RATED WINDOWS. | | | | | | 13.-17.)ADDRESSED. | | | | | | 18.)REVISE THE PERMIT APPLICATION | | | DESCRIPTION OF WORK.THIS IS NOT ONLY | | | AN INTERIOR REMODEL. | | | | | | 19.)SEE ELECTRIC REVIEW #2 AND THE | | | ATTACHED FS553.80(2)(B).A 4X PLAN | | | REVIEW FEE HAS BEEN CHARGED AS REQUIRED | | | BY FLORIDA STATUTE.A RESUB FEE WILL | | | NOT BE CHARGED.A BILL IS ATTACHED AND | | | MUST BE PAID PRIOR TO RESUBMITTAL.THIS | | | AMOUNT WILL CHANGE WHEN CORRECT | | | VALUATION IS DETERMINED. | | | | | | NEW COMMENTS: | | | | | | 20.)OCCUPANCY SEPARATION REQUIRED. | | | SPECIFY THE HORIZONTAL SEPARATION | | | BETWEEN THE BUSINESS AND RESIDENTIAL | | | OCCUPANCIES, FBC TABLE 704.1. | | | | | | 21.)THIS PERMIT APPLICATION HAS | | | EXPIRED, FBC*104.1.6, OVER SIX MONTHS | | | WITH NO ACTIVITY (12/22/05 TO 8/7/06). | | | SUBMIT A NEW PERMIT APPLICATION WITH NEW | | | PLANS.NOTE THAT GOVERNING CODE HAS | | | CHANGED EFFECTIVE OCTOBER 1, 2006 | | | (FBC2004). | | | | | | 22.)THE ROOF AND ROOF FRAMING PERMIT | | | 04100264, 04050602 ARE ALSO EXPIRED. | | | APPLY FOR NEW PERMITS.A LICENSED | | | ROOFING CONTRACTOR WILL BE REQUIRED FOR | | | THE ROOF PERMIT; A CBC CANNOT DO ROOFING | | | WORK ON A MODIFIED SYSTEM (NAIL-ON | | | SYSTEMS ONLY).INCLUDE ALL WORK | | | REQUIRED TO COMPLY WITH THE CBAA ORDER | | | WHEN RESUBMITTING (2ND FLOOR FRAMING, | | | ROOF FRAMING, ROOF). | | | | | | 23.)DECLARE AN OCCUPANCY | | | SUBCLASSIFICATION, FBC311. | | | | | | 24.)THE HANDRAIL IS TO BE 34 TO 38IN, | | | FBC1007.5 UNLESS A PART OF THE | | | GUARDRAIL. | | | | | | 25.)HANDRAIL EXTENSIONS REQUIRED AT | | | TOP AND BOTTOM OF THE STAIR, PROVIDE | | | DETAILS AND SHOW ON THE FLOOR PLAN, | | | FBC1007.5.5. | | | | | | 26.)HANDRAILS AND GUARDRAILS TO COMPLY | | | WITH FBC1608.2.1.1 AND FBC1608.2.2 | | | RESPECTIVELY.PLEASE STATE DESIGN | | | CRITERIA ON THE PLAN. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-12-22 |
Time |
10:57 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2005-12-21 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)SEE PREVIOUS LIST, ITEM #5.NOTE | | | THE 1 HOUR FIRE RATING REQUIREMENT FOR | | | THE WALL AT THE EXTERIOR STAIR. | | | | | | 2.)SEE PREVIOUS LIST, ITEM #7, | | | FBC1006.2.4.NOTE THE FOLLOWING: | | | | | | A. THE DOOR IS TO HAVE A CLOSER; "FIXED | | | OR SELF-CLOSING OPENING PROTECTIVES." | | | | | | B. THE PLANS SPECIFY 2 HOUR FIRE RATED | | | ENTRY DOORS.THE MINIMUM CODE | | | REQUIREMENT IS A 45 MINUTE ASSEMBLY.IT | | | IS ACCEPTABLE TO EXCEED CODE; HOWEVER, I | | | AM BRINGING THIS TO YOUR ATTENTION. | | | | | | C. THE WINDOWS SPECIFIED ON THE PLAN ARE | | | SINGLE HUNG.THIS DOES NOT COMPLY WITH | | | THE REQUIREMENT "SHALL BE EQUIPPED WITH | | | FIXED 3/4 HOUR ASSEMBLIES." | | | | | | D. SPECIFY FIRE RATING REQUIREMENT FOR | | | THE WINDOWS. | | | | | | 3.)THE ENERGY CALCS WHICH WERE | | | PREVIOUSLY SUBMITTED ARE NO LONGER IN | | | THE PACKAGE. | | | | | | 4.)SEE PREVIOUS LIST, ITEM #10. | | | POLICY IN REGARDS TO MISSILE IMPACT | | | PROTECTION IS ATTACHED.THE PLAN NOW | | | SPECIFIES ACCORDION SHUTTERS, BUT | | | PRODUCT APPROVALS FOR GALVANIZED STEEL | | | SHUTTERS WERE SUBMITTED.REMOVABLE | | | SHUTTERS NOT ALLOWED FOR THE SECOND | | | FLOOR, AND REMOVABLE SHUTTERS MUST BE | | | APPROVED BY THE BUILDING OFFICIAL FOR | | | THE FIRST FLOOR.ADDRESS. | | | | | | 5.)COMPLETE THE ATTACHED INSTALLATION | | | SCHEDULE (SHUTTERS), OR PROVIDE ALL | | | REQUIRED INFORMATION IN A SIMILAR | | | FORMAT. | | | | | | 6.)PRODUCT APPROVALS FOR JELD-WEN | | | DOORS WERE SUBMITTED.THERE ARE THREE | | | DIFFERENT PRODUCT APPROVALS IN THE | | | BROCHURE.SUBMIT ONLY THE DOOR YOU WILL | | | INSTALL. | | | | | | 7.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVALS REQUIRED IN ADDITION TO NOAS | | | SUBMITTED, FAC9B72. | | | WWW.FLORIDABUILDING.ORG | | | | | | 8.)SEE PREVIOUS LIST, ITEM #6. | | | PROVIDE FIRE RATING INFORMATION FOR THE | | | PRODUCT YOU ARE INSTALLING.THE PRODUCT | | | APPROVALS FOR THE DOORS DO NOT INDICATE | | | THAT THEY HAVE A FIRE RATING. | | | | | | 9.)SEE PREVIOUS LIST, ITEM #6.THE | | | ENTRY DOORS ARE TO BE APPROVED BY | | | HISTORIC PRIOR TO RESUBMITTAL AS PER | | | THEIR LETTER DATED 11/20/03, WHICH IS NO | | | LONGER IN THE PACKAGE. | | | | | | 10.)YOU HAVE DONE A CHANGE TO THE | | | EXTERIOR OF THE BUILDING (ADDED | | | ACCORDION SHUTTERS).THIS REQUIRES | | | APPROVAL FROM HISTORIC PRESERVATION | | | DEPARTMENT. | | | | | | 11.)PRODUCT APPROVAL FOR TRACO SINGLE | | | HUNG EGRESS WINDOW WAS SUBMITTED.THIS | | | IS ACCEPTABLE FOR THE WINDOWS WHICH ARE | | | NOT REQUIRED TO BE FIRE RATED; HOWEVER, | | | FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72.PLEASE PROVIDE. | | | WWW.FLORIDABUILDING.ORG | | | | | | 12.)PRODUCT APPROVALS AND FIRE RATING | | | INFORMATION FOR THE FIRE RATED WINDOWS. | | | | | | 13.)SEE FBC905.2.2 IN REGARDS TO SMOKE | | | DETECTOR REQUIREMENTS. | | | | | | 14.)SEE PREVIOUS LIST, ITEM #20, IN | | | REGARDS TO VALUATION. | | | | | | 15.)SEE PREVIOUS TWO LISTS, ITEM #21, | | | IN REGARDS TO ROOF DRAINS AND OVERFLOW | | | DRAINS.SCUPPERS ARE SHOWN BUT NO | | | INFORMATION PROVIDED IN REGARDS TO | | | PRIMARY AND SECONDARY DRAINAGE SYSTEM. | | | SEE FBC1503.4. | | | | | | 16.)PROVIDE A DETAIL FOR THE PRIMARY | | | AND SECONDARY SCUPPERS, FBC1503.4, | | | FBC1503.4.2. | | | | | | 17.)PROVIDE THE PARAPET WALL HEIGHT AS | | | THIS INFORMATION IS REQUIRED TO | | | DETERMINE DRAINAGE REQUIREMENTS. | | | | | | 18.)REVISE THE PERMIT APPLICATION | | | DESCRIPTION OF WORK.THIS IS NOT ONLY | | | AN INTERIOR REMODEL. | | | | | | 19.)SEE ELECTRIC REVIEW #2 AND THE | | | ATTACHED FS553.80(2)(B).A 4X PLAN | | | REVIEW FEE HAS BEEN CHARGED AS REQUIRED | | | BY FLORIDA STATUTE.A RESUB FEE WILL | | | NOT BE CHARGED.A BILL IS ATTACHED AND | | | MUST BE PAID PRIOR TO RESUBMITTAL.THIS | | | AMOUNT WILL CHANGE WHEN CORRECT | | | VALUATION IS DETERMINED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-06-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-11 |
Time |
13:09 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-06-11 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2005-06-11 00:00:00 | PERMIT #05021387 | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED, FS713.13. | | | | | | 2.)HOW WILL THE OCCUPANCY SEPARATION | | | BETWEEN THE FIRST AND SECOND FLOOR BE | | | MAINTAINED AT THE BEARING WALL ON THE | | | FIRST FLOOR? | | | | | | THE FOLLOWING COMMENTS REMAIN FROM THE | | | PREVIOUS REVIEW.YOUR RESPONSE LETTER | | | STATING THAT THESE ITEMS WILL BE | | | ADDRESSED UNDER A SEPARATE PERMIT IS | | | ACKNOWLEDGED.THE BOARD ORDER IS TO | | | BRING THE ENTIRE BUILDING UP TO CODE | | | COMPLIANCE.THIS CANNOT BE DONE UNDER | | | SEPARATE PERMITS.IF THIS IS NOT | | | ADDRESSED, THE DEMOLITION ORDER TO | | | DEMOLISH THE BUILDING WILL BE REINSTATED | | | AS PER BUILDING OFFICIAL. | | | | | | 3.)THE APPLICATION 03111034 INCLUDING | | | ALL WORK TO BE PERFORMED TO BRING THE | | | BUILDING UP TO CODE (FBC3401.7.2.6) HAS | | | EXPIRED.THIS APPLICATION IS TO INCLUDE | | | ALL WORK REQUIRED BY THE BOARD ORDER AND | | | FBC3401.7.2.6.AS THE EXTERIOR IS NOT | | | CURRENTLY CODE COMPLIANT, THIS CANNOT BE | | | "INTERIOR RENOVATION ONLY" AS STATED ON | | | THE APPLICATION AND PLANS. | | | | | | 4.)PROVIDE A FLOOR PLAN FOR THE FIRST | | | FLOOR - ***NOTE***TO BE DONE AT A FUTURE | | | DATE AS A TENANT BUILDOUT 8/8/05*** | | | | | | 5.)THE EXTERIOR STAIR IS TO COMPLY | | | WITH FBC1006.2.4.PROVIDE ELEVATIONS | | | AND INDICATE, TO SCALE, ALL OPENINGS | | | WHICH REQUIRE FIRE RESISTANCE.SHOW ONE | | | HOUR RATING REQUIRED ON THE PLAN. | | | | | | 6.)PROVIDE PRODUCT APPROVALS AND FIRE | | | RATING INFORMATION FOR OPENINGS AFFECTED | | | BY COMMENT #10.EXTERIOR DOORS ARE TO | | | BE APPROVED BY HISTORIC PRESERVATION | | | DEPARTMENT AS PER LETTER DATED 11/20/03. | | | | | | 7.)THE ENTRY DOOR IS REQUIRED TO HAVE | | | A FIRE RATING AND A CLOSER, 1006.2.4. | | | | | | 8.) PROVIDE A SURVEY FOR THIS PROPERTY. | | | CHECK FOR FBC TABLE 600 COMPLIANCE | | | BEFORE RESUBMITTAL. | | | | | | 9.) BEDROOMS ARE REQUIRED TO HAVE | | | EMERGENCY EGRESS, FBC1005.4.SHOW | | | COMPLIANCE ON THE PLAN (WINDOW TYPE, | | | SIZE AND SILL HEIGHT). | | | | | | 10.) SEE ATTCHED IMPLEMENTATIN STANDARD | | | FOR HURRICANE MISSILE IMPACT PROTECTION, | | | ITEM #13.IMPACT GLASS IS REQUIRED FOR | | | THE SECOND FLOOR.NON IMPACT WITH | | | SHUTTERS CAN BE APPROVED BY THE BUILDING | | | OFFICIAL.A PLAN MUST BE SUBMITTED FOR | | | REVIEW. | | | | | | 11.) SHOW TREAD AND RISER DIMENSIONS FOR | | | THE EXTERIOR EGRESS STAIR, FBC1007.3. | | | SHOW STAIR WIDTH. | | | | | | 12.) SHOW VERTICAL RISE FOR THE EXTERIOR | | | STAIR, FBC1007.4. | | | | | | 18.) PROVIDE DETAILS FOR THE HANDRAIL | | | AND GUARDRAIL, FBC1015, 1007.5.PROVIDE | | | DESIGN CRITERIA FOR BOTH THE GUARDRAIL | | | AND HANDRAIL FBC1608.2.DO NOT STATE | | | CODE SECTION BY NUMBER; SPECIFY DESIGN | | | CRITERIA.THIS COMMENT APPLIES TO BOTH | | | THE HANDRAIL/GUARDRAIL AT THE STAIRS AND | | | THE GUARDRAIL AT THE BALCONY. | | | | | | 19.) STAIRWAYS SHALL HAVE HANDRAILS ON | | | EACH SIDE, FBC1007.5.2. | | | | | | 20.) ADJUST THE VALUE OF THE SCOPE OF | | | WORK TO INCLUDE ALL WORK REQUIRED. | | | | | | 21.) SHOW COMPLIANCE WITH FBC1503.4, | | | ROOF DRAINS AND FBC1503.4.2, OVERFLOW | | | DRAINS.YOUR STATEMENT THAT THE WORK | | | HAS BEEN COMPLETED IS ACKNOWLEDGED, BUT | | | PLEASE SHOW CODE COMPLIANCE AS THIS WORK | | | HAS NOT BEEN PERMITTED. | | | | | | 22.) THE PREVIOUS APPLICATION INCLUDED | | | CONCRETE RESTORATION WORK.PROVIDE A | | | SPECIFICATION AND LOCATION OF REPAIR | | | WORK, OR INDICATE THAT THIS WORK IS NO | | | LONGER NECESSARY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-10 |
Time |
12:16 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2005-03-09 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2005-03-10 00:00:00 | PERMIT #05021387 | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED, FS713.13. | | | | | | 2.)THE APPLICATION 03111034 INCLUDING | | | ALL WORK TO BE PERFORMED TO BRING THE | | | BUILDING UP TO CODE (FBC3401.7.2.6) HAS | | | EXPIRED.THIS APPLICATION IS TO INCLUDE | | | ALL WORK REQUIRED BY THE BOARD ORDER AND | | | FBC3401.7.2.6.AS THE EXTERIOR IS NOT | | | CURRENTLY CODE COMPLIANT, THIS CANNOT BE | | | ?INTERIOR RENOVATION ONLY? AS STATED ON | | | THE APPLICATION AND PLANS. | | | | | | 3.)THE PERMIT ISSUED FOR THE ROOF | | | FRAMING (04050602) HAS EXPIRED.APPLY | | | FOR A NEW PERMIT. | | | | | | 4.)NO INSPECTIONS HAVE BEEN DONE ON | | | THE ROOF PERMIT ISSUED (04100264).THE | | | WORK HAS BEEN COMPLETED AS PER | | | CONVERSATION WITH THE CONTRACTOR. | | | SCHEDULE INSPECTIONS AS REQUIRED BY | | | FBC105(4).THIS PERMIT WILL EXPIRE | | | APPROXIMATELY APRIL 7, 2005. | | | | | | 5.)INFORMATIONAL ONLY; THERE IS ALSO | | | AN OPEN WINDOW PERMIT ON THIS JOB, | | | 04070723. | | | | | | 6.)SHEET 2 OF 5 SHOWS A CHANGE TO THE | | | EXTERIOR (REMOVAL AND REPLACEMENT OF | | | WINDOWS).APPROVAL REQUIRED FROM THE | | | HISTORIC PRESERVATION DEPARTMENT. | | | | | | 7.)DECLARE AN OCCUPANCY FOR THE FIRST | | | FLOOR AND SECOND FLOOR, FBC CHAPTER 3. | | | | | | 8.)SHOW REQUIRED FIRE SEPARATION FBC | | | TABLE 704.1 BETWEEN THE FIRST AND SECOND | | | FLOOR, EITHER AS A RATED ASSEMBLY OR | | | CALCULATED FIRE RESISTANCE FBC709. | | | PROVIDE DETAILS FOR PENETRATIONS THROUGH | | | THE FIRE RATED ASSEMBLY FBC705.6. | | | | | | 9.)PROVIDE A FLOOR PLAN FOR THE FIRST | | | FLOOR. | | | | | | 10.)THE EXTERIOR STAIR IS TO COMPLY | | | WITH FBC1006.2.4.PROVIDE ELEVATIONS | | | AND INDICATE, TO SCALE, ALL OPENINGS | | | WHICH REQUIRE FIRE RESISTANCE.SHOW ONE | | | HOUR RATING REQUIRED ON THE PLAN. | | | | | | 11.)PROVIDE PRODUCT APPROVALS AND FIRE | | | RATING INFORMATION FOR OPENINGS AFFECTED | | | BY COMMENT #10.EXTERIOR DOORS ARE TO | | | BE APPROVED BY HISTORIC PRESERVATION | | | DEPARTMENT AS PER LETTER DATED 11/20/03. | | | | | | 12.)THE ENTRY DOOR IS REQUIRED TO HAVE | | | A FIRE RATING AND A CLOSER, 1006.2.4. | | | | | | 13.) PROVIDE A SURVEY FOR THIS PROPERTY. | | | CHECK FOR FBC TABLE 600 COMPLIANCE | | | BEFORE RESUBMITTAL. | | | | | | 14.) BEDROOMS ARE REQUIRED TO HAVE | | | EMERGENCY EGRESS, FBC1005.4.SHOW | | | COMPLIANCE ON THE PLAN (WINDOW TYPE, | | | SIZE AND SILL HEIGHT). | | | | | | 15.) WHERE WILL THE HURRICANE SHUTTERS | | | BE STORED? | | | | | | 16.) SHOW TREAD AND RISER DIMENSIONS FOR | | | THE EXTERIOR EGRESS STAIR, FBC1007.3. | | | SHOW STAIR WIDTH. | | | | | | 17.) SHOW VERTICAL RISE FOR THE EXTERIOR | | | STAIR, FBC1007.4. | | | | | | 18.) PROVIDE DETAILS FOR THE HANDRAIL | | | AND GUARDRAIL, FBC1015, 1007.5.PROVIDE | | | DESIGN CRITERIA FOR BOTH THE GUARDRAIL | | | AND HANDRAIL FBC1608.2.DO NOT STATE | | | CODE SECTION BY NUMBER; SPECIFY DESIGN | | | CRITERIA.THIS COMMENT APPLIES TO BOTH | | | THE HANDRAIL/GUARDRAIL AT THE STAIRS AND | | | THE GUARDRAIL AT THE BALCONY. | | | | | | 19.) STAIRWAYS SHALL HAVE HANDRAILS ON | | | EACH SIDE, FBC1007.5.2. | | | | | | 29.) ADJUST THE VALUE OF THE SCOPE OF | | | WORK TO INCLUDE ALL WORK REQUIRED. | | | | | | 30.) SHOW COMPLIANCE WITH FBC1503.4, | | | ROOF DRAINS AND FBC1503.4.2, OVERFLOW | | | DRAINS. | | | | | | 31.) THE PREVIOUS APPLICATION INCLUDED | | | CONCRETE RESTORATION WORK.PROVIDE A | | | SPECIFICATION AND LOCATION OF REPAIR | | | WORK. | | | | | | 32.) ENERGY CALCS REQUIRED, FBC13. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-08-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-23 |
Time |
19:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-23 |
Time |
18:40 |
Sent To |
|
|
| Notes |
| 2006-08-23 00:00:00 | *** 4TH REVIEW *** | | | | | | THIS PERMIT IS STILL UNDER THE 2001 FBC. | | | | | | 1) NOTE: PLEASE CORRELATE ALL AIC | | | RATINGS ON PLANS. PLEASE VERIFY THE | | | AVAILABLE FAULT CURRENT AS THE NEW | | | METER/COMBO IS BEING SHOWN AS 42K WHICH | | | IS MENTIONED AS 80 FT AWAY FROM THE FPL | | | TRANSFORMER. | | | PLEASE KNOW, THE FURTHER AWAY, THE LESS | | | THE AVAILABLE FAULT CURRENT IS. PLEASE | | | SEE PLANS INDICATE THE PANEL UPSTAIRS AS | | | 22K NAD RISER SHOWS THIS PANEL AS 10K. | | | PLEASE SEE A/C DISCONNECT IS BEING SHOWN | | | AS 10K RATED. PLEASE KNOW, THE RATING OF | | | THE A/C DISCONNECT IS NOT NEEDED. | | | 110.9, | | | FBC 104.2.1 | | | | | | 2) NOTE: PLEASE SEE 210.21B3, PLEASE SEE | | | A RANGE/STOVE RECEPT IS 50A RATED, | | | PLEASE SEE PANEL SCHEDULE IS SHOWING A | | | 60A BRKR. PLEASE SEE CODE ABOVE, NO MORE | | | THAN 50A OCP IS PERMITTED. | | | | | | 3) NOTE: PLEASE KNOW, IT IS UNDERSTOOD | | | FROM THIS OFFICE THE DOWNSTAIRS IS | | | HAVING TO BE BROUGHT UP TO CODE AND MUST | | | BE DONE AT THIS TIME. (EVEN IF FOR SHELL | | | OF FUTURE OFFICE) | | | PLEASE SHOW THE LOCATION OF THE NEW | | | PANEL AND SHOW MIN LTS REQUIRED FOR | | | EGRESS AND EXITING. | | | PLEASE KNOW, WE ARE UNABLE TO VERIFY THE | | | MIN CLEARENCES FOR THE PANEL PER 110.26 | | | AND LOCATION FOR PANEL PER 240.24. | | | PLEASE SEE NFPA-101 2003 FOR MIN LTS FOR | | | EXT AND EM LTS. 7.8, 7.9 | | | | | | 4) NOTE: PLEASE SEE LOAD CALCULATIONS | | | ARE SHOWING LOAD FOR WHAT SEEMS TO BE | | | DEDICATED RECEPTS OF SOME SORT YET THIS | | | COULD NOT BE FOUND ON PANEL SCHEDULE. | | | (3KW)? PLEASE SEE 500VA ALSO SHOWN FOR | | | SD'S? | | | PLEASE SEE ALL GEN LTS AND RECEPTS FOR | | | UPPER SPACE SHALL BE INCLUDED IN THE MIN | | | 3VA PER SQ FT. | | | 220.31 | | | | | | 5) NOTE: PLEASE SEE THE PLANS SHALL | | | INDICATE ALL THE RELEVANT CODES AT A | | | MIN. | | | 2001 FBC, 2002 NFPA-70, 2002 NFPA-72, | | | 2003 NFPA-101 | | | | | | 6) NOTE: PLEASE SEE A RESPONSE NOTE | | | MENTIONS A CONFLICT IN ELECTRICAL REVIEW | | | AND FIRE REVIEW FOR REQUIRMENT OF THE | | | SD'S OUTSIDE SLEEPING ROOMS/ AND | | | KITCHENS. | | | PLEASE SEE NFPA-72 11.8.3, 11.5.1.1, | | | SD'S ARE REQUIRED OUTSIDE ALL SLEEPING | | | ROOMS AND IF WITHIN 20' OF COOKING | | | APPLIANCES, THEN THE SD'S MUST BE | | | RE-SETTING TYPE/PHOTO-ELECTRIC EYE. | | | | | | 7) NOTE: PLEASE BE SURE THE ENERGY | | | CALCULATIONS SUBMITTED CONTAIN AN | | | ORIGINAL SIGNATURE, DATE AND SEAL FROM | | | THE DESIGN PROFESSIONAL. | | | FS471.025 | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-12-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-21 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-21 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2005-12-21 00:00:00 | *** UNSAT *** | | | | | | PLEASE SEE MANY NEW COMMENTS DUE TO | | | CHANGES MADE TO PLANS. | | | PLEASE ALSO SEE COMMENT FROM OTHER | | | REVIEWS NOT ADDRESSED. | | | | | | | | | 1)NOTE: PLEASE SEE PLANS HAVE NOW | | | DELETED TWO OF THE REQUIRED SD'S ON | | | PLANS? | | | NFPA-72 11.5.1.1 | | | | | | 2)NOTE: PLEASE ALSO PREVIOUS PLANS HAD | | | MADE CORRECTIONS FOR SD'S TO BE ON AN | | | ARC FAULT PROTECTED CIRCUIT AS REQUIRED | | | PER 2002 210.12 AND NOTED ON PREVIOUS | | | REVIEWS, HOWEVER PLEASE SEE THIS CIRCUIT | | | AHS NOW REMOVED THE ARC FAULT | | | PROTECTION.??? | | | | | | 3)NOTE: PLEASE SEE PLANS DO NOT SHOW THE | | | NEW SERVICE LOCATION ON PLANS. PLEASE | | | SEE PLANS ONLY INDICATE THE NEW METER. | | | 215.5 | | | | | | 4)NOTE: PLEASE NOW SEE THE NEW SERVICE | | | RISER HAS COMPLETELY CHANGED WHICH IS | | | INTRODUCING MANY NEW COMMENTS. | | | | | | PLEASE SEE CONDUCTORS ON RISER AND FOR | | | FEEDERS TO PANELS ARE INDICATING SERVICE | | | BEING A 3-PHASE SERVICE.PLEASE ADJUST | | | | | | PLEASE SEE RISER SHOWS A 200A FEED TO A | | | 200A PANEL , HOWEVER , PLEASE SEE NO | | | PANEL SCHEDULE SUBMITTED TO CORRELATE | | | WITH THIS. THE ONLY PANEL SCHEDULE SHOWN | | | IS A 150A PANEL FOR UNIT UPSTAIRS. | | | | | | PLEASE SEE GROUNDING ELECTRODE CONDUCTOR | | | IS NOW REQUIRED TO BE INCREADED PER | | | 250.66 AND SIZING OF SEC'S. | | | | | | 5)NOTE: PLEASE SEE TWO CIRCUITS GOING TO | | | THE SAME DEVICE IN BEDRMS. (SWITCHED | | | RECEPT) PLEASE SEE THIS WOULD REQUIRE | | | THE USE OF A TWO POLE BREAKER IN PANEL, | | | HOWEVER PLEASE SEE THERE ARE THREE | | | CIRCUITS SHARED IN THIS SCENERIO WHICH | | | WOULD BE ABLE TO BE DONE. | | | | | | 6)NOTE: PLEASE SEE NOW LOAD CALCUALTIONS | | | SUBMITTED FOR FIRST FLOOR WHICH DO NO | | | CORRELATE WITH THE NEC AND OFFICE OR | | | MERCHANTILE OCCUPANCY AS INIDCATED ON | | | THE PLANS. | | | PLEASE SEE 220 OF THE NEC FOR CORRECTED | | | LOAD CALCS. | | | 220.3,220.10,220.11,220.13,215.3,230.42 | | | ETC | | | ALL CONTINUOUS LOADS ARE TO BE SHOWN AT | | | 125%. | | | | | | ** PLEASE SEE ONE SET OF NEW PLANS AND | | | OLD HAVE BEEN RETAINED FOR FILE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-14 |
Time |
05:55 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-06-13 |
Time |
19:19 |
Sent To |
|
|
| Notes |
| 2005-06-14 00:00:00 | *********** UNSAT2ND REVIEW ********* | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW STILL NEED TO BE ADDRESSED. | | | PLEASE ALSO SEE NEW NOTES. | | | | | | 1)NOTE: NOTE #1 OK. | | | | | | 2)NOTE: NOTE #2 OK, HOWEVER PLEASE SEE | | | LOWER AREA FOR STAIRS NOW SHOWS A | | | PC(PULL CHAIN)? FOR CONTROL OF EGRESS | | | LIGHTING. PLEASE SEE A 3-WAY WP SWITCH | | | IS REQUIRED. | | | 210.70,LS 101 5-8 | | | | | | 3)NOTE: NOTE #3 OK. | | | | | | 4)NOTE: NOTE #4 OK. | | | | | | 5)NOTE: NOTE #5 NO, PLEASE SEE | | | COUNTERSPACE. SCALE FOR ELECTRICAL PLANS | | | NOT PROVIDED, HOWEVER IF USEING 1/8" MIN | | | PER CODE THERE APPEARS TO BE MISSING PER | | | 210.52C1. PLEASE SEE REDLINED PLANS. | | | | | | 6)NOTE: NOTE #6 NO, PLEASE SEE 210.8A6 | | | AS NOTED ON PREVIOUS NOTE. | | | | | | 7)NOTE: NOTE #7 OK. | | | | | | 8)NOTE: NOTE #8 OK. | | | | | | 9)NOTE: NOTE #9 NO, PREVIOUS. | | | | | | 10)NOTE: NOTE #10 NO, NEW SERVICE SHOWN, | | | YET NO INFORMATION PROVIDED FOR EXISTING | | | SERVICE, MAINS, GROUPING ETC. A NEW | | | SERVICE WILL NOT BE PERMITTED. | | | 230.2 | | | PLEASE SEE 110.9, AIC RATING PROVIDED | | | FOR PANEL, HOWEVER RATING FOR MAIN ALSO | | | REQUIRED. | | | | | | 11)NOTE: NOTE #11OK. | | | | | | 12)NOTE: NOTE #12 OK, HOWEVER SEE NEW | | | NOTES FOR OUTSIDE RECEPT. | | | | | | 13)NOTE: NOTE #13 NO. | | | PLEASE SEE PREVIOUS AND PLEASE SEE FAC | | | 61G1-16.004 FOR ALL INFORMATION REQUIRED | | | ON TITLE BLOCK. | | | | | | 14)NOTE: NOTE #14 OK. | | | | | | 15)NOTE: NOTE #15 OK. | | | | | | NEW NOTES: | | | | | | 1)NOTE: PLEASE SEE NEW GFI RECEPT FOR | | | A/C COND IS NOW SHOWN CIRCUITED ON | | | KITCHEN SMALL APPLIANCE CIRCUIT.PLEASE | | | SEE 210.52B | | | | | | 2)NOTE: PLEASE SEE BLDG REVIEW COMMENTS | | | FOR BLDG AND SCOPE OF WORK BRINGING BLDG | | | UP TO CODE PER FBC CHAPTER 34. | | | THIS WILL HAVE A DIRECT AFFECT ON | | | ELECTRICAL PLANS AND WORK ALSO REQUIRED | | | IN OTHER PARTS OF STRUCTURE. | | | | | | 3)NOTE: PLEASE SEE THE ATTACHED COPY OF | | | FS 553.80(2)(B) WITH RESPECT TO THE | | | DESIGN PROFESSIONAL AND REPEAT COMMENTS | | | FOR THE SAME CODE ARTICLES. | | | THIS IS ONLY A NOTICE GIVEN AT THIS | | | TIME. | | | | | | | | | | | | PLEASE BE SURE TO REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING.\ | | | PLEASE SUBMIT ONE COPY OF OLD SHEETS FOR | | | REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2005-06-13 00:00:00 | NOTES TO FOLLOW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-28 |
Time |
07:29 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-02-28 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2005-02-28 00:00:00 | ******** UNSAT *********** | | | | | | 1)NOTE: PLEASE PROVIDE OCCUPANCY FOR | | | FIRST FLOOR AREA AND USE. | | | | | | 2)NOTE: THE LAUNDRY CIRCUIT CALCULATION | | | MUST COMPLY WITH 220.116(B).(1500 VA). | | | | | | 3)NOTE: PLEASE SEE 210.70, LS 101 5-8, | | | PLEASE VERIFY MEANS OF EGRESS LIGHTING | | | FROM SECOND FLR TO GRADE LEVEL. | | | | | | 3)NOTE: PLEASE SHOW OUTLET SPACING PER | | | 210.52. 2',6`,12` RULE. | | | | | | 4)NOTE: PLEASE SEE 210.11C1, TWO SM APPL | | | CIRCUITS MIN. | | | | | | 5)NOTE: PLEASE SEE 210.52C1 FOR KITCHEN | | | COUNTERSPACE. | | | | | | 6)NOTE: PLEASE SHOW ALL RECEPTS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED PER 210.8A-6 | | | | | | 7)NOTE: PLEASE SEE 240.4B,310.16 FOR MIN | | | SIZE AWG FOR RANGE ON A 2P-60A. | | | | | | 8)NOTE: PLEASE SEE 424.3B FOR MIN OCP | | | FOR AHU. MIN 125%. PLEASE ALSO SEE | | | 310.16/240.4 FOR SIZING OF AWG. | | | PLEASE SEE 8KW SHOWN ON 2P30A AND #10. | | | | | | 9)NOTE: PLEASE SEE 210.52C3 FOR | | | PENINSULAR GFI REQUIRED. | | | | | | 10)NOTE: PLEASE VERIFY IF PANEL IS NEW | | | OR EXSITING. SHOWN AS NEW ANDNOTES | | | MENTIONS NEW GROUND RODS ? | | | PLEASE INCLUDE RISER DIAGRAM FOR FEED TO | | | NEW PANEL. MAIN, GROUPING, GROUNDING, | | | CONDUCTORS ETC. | | | 215.5 | | | PLEASE ALSO SUBMIT AIC RATING FOR NEW | | | EQUIPMENT. 110.9. | | | | | | 11)NOTE: PLEASE INCLUDE ALL CIRCUITING | | | ON PLANS AND CORRELATE WITH A PANEL | | | SCHEDULE. | | | | | | 12)NOTE: PLEASE SHOW AHU/A/C UNITS ALONG | | | WITH REQUIRED DISC'S PER 440-11. | | | PLEASE ALSO SEE 210.63 FOR REQUIRED GFI | | | FOR COND UNIT. | | | | | | 13)NOTE: PLEASE CORRELATE ADDRESS ON | | | PLANS AND APPLICATION. ONE MENTIONS, 800 | | | SAPPODILLA, AND THE OTHER 633 37TH ST? | | | PLEASE ALSO SEE BLDG REVIEW COMMENTS FOR | | | SUITE # OR EXTENSION TO BLDG. | | | | | | 14)NOTE: PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | | | | 15)NOTE: PLEASE SEE NFPA-72 8-1.4.2, SD | | | NOT PERMITTED IN KITCHEN. | | | PLEASE ALSO SEE MIN DISTANCE SD IS | | | REQUIRED TO BE FROM COOKING APPLIANCES | | | WITH EXCEPTIONS. | | | PLEASE ALSO SEE SD'S ARE ALSO REQUIRED | | | TO BE A MIN OF 3' FROM BATH DOORS. | | | | | | | | | PLEASE SEE OTHER POSSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | INSERT ONLY NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-09-15 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-09-15 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-12-22 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-12-22 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE NOTE THAT REQUIRED SMOKE | | | DETECTORS HAVE BEEN REMOVED FROM SHEETS. | | | PLEASE SHOW LOCATIONS OF SMOKE DETECTORS | | | IN ACCORDANCE WITH NFPA 101, SEC. | | | 24.3.4.2. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561)805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-06-15 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-06-15 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2005-06-15 00:00:00 | DENIED | | | | | | 1) SHALL COMPLY WITH NFPA 101 LIFE | | | SAFETY CODE, 2003 EDITION CH. 24.1.2 | | | MULTIPLE OCCUPANCIES. | | | | | | 2) INTERIOR WALL AND CEILING FINISH | | | MATERIALS COMPLYING WITH SECTION 10.2 | | | SHALL BE CLASS A, CLASS B, OR CLASS C. | | | | | | 3) THE ENTRANCE DOOR THAT LEADS TO THE | | | EXISTING STAIRS MUST COMPLY WITH NFPA | | | 101, SECTION 7.2.1. | | | | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL | | | 561-835-2935 OR 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-23 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-23 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2005-03-23 00:00:00 | 1) PLEASE PROVIDE INFORMATION REGARDING | | | OCCUPANCY USE FOR BOTH FLOORS OF THE | | | BUILDING. | | | | | | 2) PLEASE PROVIDE INTERIOR FINISH | | | INFORMATION FOR WALLS AND CEILING. | | | | | | 3) ABC TYPE FIRE EXTINGUISHERS MAY BE | | | REQUIRED CONTINGENT ON ADDITIONAL | | | OCCUPANCY INFORMATION. | | | | | | 4)THE ENTRANCE DOOR THAT LEADS TO THE | | | EXISTING STAIRS MUST COMPLY WITH NFPA | | | 101, SECTION 7.2.1. | | | | | | 5) PLEASE BE ADVISED THAT ALL LIFE | | | SAFETY MUST COMPLY WITH NFPA 101, 2003 | | | EDITION. | | | | | | 6) PLEASE BE ADVISED THAT ALL | | | DEMOLITION. RENOVATION AND CONSTRUCTURE | | | SHALL BE IN ACCORDANCE WITH NFPA 241. | | | | | | 7) PLEASE PROVIDE ADDITIONAL MEANS OF | | | EGRESS INFORMATION ONCE THE EXISTING | | | STAIRS ARE REACHED. | | | | | | | | | MIKE WENNERGREN, ACTING CAPTAIN | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-08 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-08 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2006-08-22 00:00:00 | TO "COMM" BD#16 | | 2006-08-08 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-14 |
Time |
18:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-14 |
Time |
18:37 |
Sent To |
|
|
| Notes |
| 2005-12-09 00:00:00 | MOVED TO SPACE #55 | | 2005-11-29 00:00:00 | TO "COMM" BD#60 | | 2005-11-14 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-07 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-07 |
Time |
07:20 |
Sent To |
|
|
| Notes |
| 2005-06-07 00:00:00 | TO COMM BD#32 RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-27 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-27 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2005-05-27 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-25 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-25 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2005-02-25 00:00:00 | TO "COMM" BD#15 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
|
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-10-02 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-10-02 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-10-02 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-10-02 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2006-10-02 00:00:00 | PASS PRIVISO | | | PLEASE REFER TO SECTION 602.2.1 FBD(M) | | | 2004 MATERIALS EXPOSED WITHIN PLENUMS. | | | PLAN REVIEW BY HAROLD MOAER 561-805-6732 | | 2006-08-23 00:00:00 | NEW SHEETS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-06-21 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-06-21 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-21 |
Time |
07:56 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-03-21 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2005-03-21 00:00:00 | DENIED: | | | 1.PROVIDE DUCT SIZE ON THE SUPPLY | | | BRANCH DUCTS.RETURN AIR JUMPERS SHALL | | | BE A MINIMUM OF 1 1/2 TIMES GREATER THAN | | | THE CROSS SECTIONAL AREA (SQAURE INCHES) | | | OF THE SUPPLY AIR TO THAT ROOM. 2001 | | | FBC/M 601.4 EXCEPTION #1. | | | | | | 2.PROVIDE GRILLE SIZES. | | | | | | 3.PROVIDE INFORMATION & DETAILS FOR | | | THE DRYER EXHAUST.INDICATE DUCT | | | MATERIAL, SIZE, AND TERMINATION. | | | | | | 4.PROVIDE SCHEDULE FOR THE EXHAUST FAN | | | LOCATED IN THE BATHROOM. | | | | | | 5.PROVIDE ENERGY AND MANUAL J | | | CALCULATIONS IN ACCORDANCE WITH 2001 FBC | | | CHAPTER 13 SUB-SECTION 600. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-05 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-05 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2006-08-23 00:00:00 | NEW SHEETS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-06-21 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-06-21 |
Time |
07:59 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-03-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-16 |
Time |
18:18 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2005-03-16 |
Time |
17:58 |
Sent To |
|
|
| Notes |
| 2005-03-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | | | | 1) SHT 5 0F 5 SANITARY RISER DIAGRAM | | | DOES NOT MEET CODE REQUIREMENTS, AND | | | SHALL BE IN AN ISOMETRIC FORM SHOWING | | | VENT CONNECTIONS. | | | 2) KITCHEN SINK IS NOT VENTED. SECTION | | | 901.2.1. | | | 3) TUB IN BATHROOM IS NOT VENTED. | | | SECTION 901.2.1. | | | 4) WASH MACHINE SHALL NOT DRAIN THROUGH | | | THE WET VENT OF THE BATHROOM FIXTURES, | | | BUT SHALL DISCHARGE DOWNSTREAM OF THE | | | BATHROOM FIXTURES. SECTION 909.1 | | | THE WASH MACHINE SHALL DISCHARGE INTO A | | | STANDPIPE AND A CLEANOUT 4' ABOVE THE | | | FLOOR IS REQUIRED. SECTIONS 1002.1 AND | | | 708.10. | | | 5) SEE ATTACHED SHEET FOR AN EXAMPLE OF | | | AN ISOMETRIC THAT MEETS CODE | | | REQUIREMENTS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2006-09-11 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2006-09-11 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2006-09-11 00:00:00 | PLEASE PROVIDE A RECENT SURVEY FOR THE | | | SUBJECT PROPERTY. | | | | | | A CLASS B SPECIAL USE PERMIT WILL BE | | | REQUIRED FOR THE ESTABLISHMENT OF ANY | | | NEW COMMERCIAL USES IN ANY OF THE | | | EXISTING COMMERCIAL SPACES ON THE | | | PROPERTY. |
|
|
|