| Plan Review Stops For Permit 05021273 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
ptjomsto |
Date |
2005-02-23 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
ptjomsto |
Date |
2005-02-23 |
Time |
17:47 |
Sent To |
|
|
| Notes |
| 2005-02-23 00:00:00 | EXT REQUIRED FOR STE #850 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-29 |
Time |
08:54 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-08-29 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2005-08-29 00:00:00 | REVISION A0, A1,A1.1, A2.0, A2.1, TI-1, | | | TI-2 DATED 7/14/05 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-30 |
Time |
09:55 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-06-30 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2005-06-30 00:00:00 | REVISION #2 DATED 5/25 | | | A1.0, A1.1, A2.0, A2.1, TI1,TI2, CS1 | | | THROUGH CS4 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-03-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-18 |
Time |
15:45 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-03-18 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-21 |
Time |
08:35 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-11-21 |
Time |
08:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-10 |
Time |
19:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-11-10 |
Time |
19:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-15 |
Time |
19:46 |
Rev Time |
0.60 |
| Received By |
dpalmer |
Date |
2005-08-15 |
Time |
19:46 |
Sent To |
|
|
| Notes |
| 2005-08-15 00:00:00 | ***** UNSAT*** | | | | | | PLEASE SEE SOME COMMENTS FROM PREVIOUS | | | REVIEW. | | | | | | | | | 1)NOTE: PLEASE SEE VALUATION FOR SCOPE | | | OF WORK WAS NOT UP DATED. NOTE ON REV | | | COVER SHEET MENTIONS THIS WILL BE PAID | | | UPON ISSUANCE. PLEASE SEE PERMIT WAS | | | ISSUED PREVIOUSLY. | | | PLEASE SEE BLDG VALUATION MAY BE | | | ASSESSED BY BLDG PLANS REVIEW. | | | FBC 104.6.5 | | | CITY OF WEST PALM BEACH AMENDMENTS. | | | | | | 2)NOTE: PLEASE SEE NOTE #4 FROM PREVIOUS | | | REVIEW. PLEASE SEE RISER IS UNCLEAR FOR | | | SCOPE OF WORK IN ADJACENT MECH/ELEC RM.? | | | PLEASE SEE ORIG PLANS SUBMITTED AND | | | THESE PLANS APPEAR TO SHOW ONLY | | | "DARKENED" LINES ON RISER TO BE INCLUDED | | | IN SCOPE OF WORK FOR THIS PERMITAND | | | PROJECT. PLEASE SEE OTHER AREAS OF RISER | | | ARE BEING REVISED ON EACH SUBMITTED | | | REVISIONS? | | | PLEASE SEE PREVIOUS PLANS SHOWED TWO | | | DISC'S, ONE NEW, ONE FUTURE, HOWEVER | | | THESE WERE NOT "DARKENED" AS NEW WORK IS | | | NOTED. PLEASE SEE THIS REVISION NOW | | | MENTIONS THIS WORK ON RISER AS | | | "EXISTING". | | | IT IS UNCLEAR HOW INFORMATION IS REVISED | | | WHEN NOT INCLUDED IN THE SCOPE OF THIS | | | PERMIT?? | | | PLEASE PROVIDE A SIGNED, DATED AND | | | SEALED RESPONSE LTR TO CLARIFY: | | | WHICH WORK ISBEING DONE UNDER THIS | | | PERMIT? | | | WHICH WORK IS NEW? | | | WHICH IS EXSITING AND NOT INCLUDED IN | | | THIS SCOPE. | | | | | | 3)NOTE: PLEASE SEE LIGHTING LOADS DO NOT | | | SEEMED TO HAVE BEEN INCREASED DUE TO | | | ADDED SQ FT FOR TENANT.? | | | 220.3 | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY SUBMITNEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE COPY OF OLD/VOIDED SHEETS MAY BE | | | SUBMITTED FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-27 |
Time |
15:53 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-06-27 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2005-06-27 00:00:00 | ********* UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE VALUE FOR ADDED SCOPE | | | OF WORK IS TO BE INCREASED. FBC 104.6.5 | | | | | | 2)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH PANEL SCHEDULE. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE SHEET E-3, WHICH DOES | | | NOT INCLUDE ANY REV'S OR UPDATED CHANGES | | | LABELED IN TITLE BLOCK. | | | PLEASE SEE ALL REV'S, CHNAGES ARE TO BE | | | SHOWN WITH CLOUDS, TRIANGLES. | | | | | | 4)NOTE: PLEASE SEE AREA LOCATED ON RISER | | | WHICH MENTIONS A NEW 100A DISC IN | | | 'ADJACENT MECH RM". PLEASE REMOVE THIS | | | AS NEW IF NOT IN SCOPE OF WORK. IF IN | | | SCOPE PLEASE SEE 240.21, TAPS SHALL NOT | | | BE MADE FROM A TAP. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-04-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-01 |
Time |
16:31 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-04-01 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-02 |
Time |
05:55 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-03-01 |
Time |
19:42 |
Sent To |
|
|
| Notes |
| 2005-03-02 00:00:00 | **** UNSAT **** | | | | | | 1)NOTE: PLEASE SHOW LOCATION OF NEW | | | PANEL 850L? PLANS SHOW 850C? | | | | | | PLEASE SEE ANY POSSIBLE NOTES FROM OTHER | | | REVIEWER(S) WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE BE SURE TO REMOVE ALL OLD/VOIDED | | | SHEETS AND INSERT NEW REVISED SHEETS | | | INTO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-11-10 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-11-10 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2005-11-10 00:00:00 | DUCT DETECTORS SHALL ACTIVATE THE FIRE | | | ALARM SYSTEM. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2005-08-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-31 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-31 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2005-08-31 00:00:00 | ******DENIED****** | | | | | | 1) FP SHEETS HAVE BEEN REMOVED FROM ONE | | | SET OF PLANS. PLEASE KEEP ALL SHEETS | | | TOGETHER UNTIL REVIEW HAS PASSED. AT | | | THAT TIME, SEPARATE SHOP DRAWINGS AND | | | PERMITS SHOULD BE APPLIED FOR. IT | | | DOESN'T APPEAR THAT COMMENT #1 HAS BEEN | | | ACKNOWLEDGED OR ADDRESSED. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2005-07-05 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-05 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-05 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2005-07-05 00:00:00 | ******DENIED****** | | | | | | 1) IN ACCORDANCE WITH LOCAL FIRE CODE | | | REQUIREMENTS, NEW DUCT SMOKE DETECTOR | | | INSTALLATIONS SHALL BE WIRED INTO THE | | | FIRE ALARM SYSTEM TO SOUND A GENERAL | | | FIRE ALARM WHEN ACTIVATED. | | | | | | 2) PLEASE NOTE THAT SHEETS FP-1 AND FP-2 | | | DON'T ILLUSTRATE ANY REVISIONS OR | | | UPDATED CHANGES IN THE TITLE BLOCK. | | | | | | 3) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR THE FIRE SPRINKLER AND | | | FIRE ALARM REMODEL. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 805-6722 OR 835-2951 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-04-12 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-04-12 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-23 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-23 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2005-03-23 00:00:00 | 1) PLEASE BE ADVISED THAT ANY NEW DUCT | | | SMOKE DETECTOR INTALLATIONS MUST BE | | | WIRED INTO THE BUILDING FIRE ALARM | | | SYSTEM, AND SOUND A GENERAL FIRE ALARM | | | WHEN ACTIVATED. | | | | | | 2) PLEASE SUBMIT SEPARATE SHOP DRAWINGS | | | FOR THE FIRE ALARM REMODEL. | | | | | | 3) PLEASE SUBMIT SEPARATE SHOP DRAWINGS | | | FOR THE FIRE SPRINKLER REMODEL. | | | | | | | | | MIKE WENNERGREN, ACTING CAPTAIN | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-27 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-27 |
Time |
16:04 |
Sent To |
P |
|
| Notes |
| 2005-12-27 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-12-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-16 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-16 |
Time |
10:57 |
Sent To |
M |
|
| Notes |
| 2005-12-16 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-14 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-14 |
Time |
16:31 |
Sent To |
P |
|
| Notes |
| 2005-12-14 00:00:00 | TO "P" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-18 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-18 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2005-11-18 00:00:00 | TO "BOB"#13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-06 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-06 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2005-10-19 00:00:00 | TO "COMM" BD#19 | | 2005-10-06 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-05 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-05 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2005-08-08 00:00:00 | TO "COMM" BD#35 | | 2005-08-05 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-06-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-02 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-02 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2005-06-02 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-01 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-04-01 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2005-04-01 00:00:00 | SENT TO COMM BOARD #26 | | | M-2 SHEET NOT STAMPED ON EITHER SET. | | | FP SHEETS NOT STAMPED BY FIRE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-30 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-30 |
Time |
14:05 |
Sent To |
E |
|
| Notes |
| 2005-03-30 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-23 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-02-24 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2005-02-24 00:00:00 | TO "COMM" BD#32 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2005-12-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-16 |
Time |
14:03 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-12-16 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2005-12-16 00:00:00 | MECH. REV. TO PLANS AND E-CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-11-14 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-11-14 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2005-11-10 00:00:00 | NEW SHEETS/OR SHEETS NOT STAMPED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-07-19 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-07-19 |
Time |
15:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-04-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-04-14 |
Time |
09:06 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2005-04-14 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-03-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-03-24 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2005-03-24 00:00:00 | FAN SHUTDOWN TEST REQUIRED FOR FINAL | | | INSPECTION. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2005-12-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2005-12-28 |
Time |
14:34 |
Rev Time |
1.25 |
| Received By |
mperson |
Date |
2005-12-28 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2005-12-28 00:00:00 | | | | | | | | | | REVISION - PROVISO | | | | | | SEWAGE PUMP SHALL BE LISTED. MANUF. | | | SPECIFICATION SHEETS SHALL BE ON THE JOB | | | AT THE TIME OF PLUMBING FINAL. SECTION | | | 303.4 | | | | | | | | | | | | | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-15 |
Time |
12:14 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-12-15 |
Time |
12:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-11-21 |
Time |
16:38 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-11-21 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2005-11-21 00:00:00 | DENIED; | | | 1.PAGE P-1 CLEAR FLOOR SPACE MUST BE A | | | FORWARD APPROACH, PLAN INDECATE A SIDE | | | APPROACH. SEE FBC-2001 CHAPTER 11 | | | SEC.11-4.24.5. | | | 2.RE-DUE INT. ELEVATION ON SHEET A-1.1 | | | SHOWING LOCATION OF NEW SEWAGE EJECTOR. | | | NEW EQUIPMENT TO BE INSTALLED MUST NOT | | | RESTRICT THE FORWARD APPROACH OR THE | | | CLEAR FLOOR SPACE. SEE SEC. 11-4.24.3 | | | AND 11-4.24.5. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-12-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-09-07 |
Time |
14:12 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-09-07 |
Time |
20:01 |
Sent To |
|
|
| Notes |
| 2005-12-19 00:00:00 | REVISION OK FOR SHEETS P-1 & P-2 ONLY |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-07-06 |
Time |
17:38 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-07-06 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2005-07-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1. SHT A1.0 NO DEAD ENDS ALLOWED SECTION | | | 704.5. FIELD INSPECTOR SHALL INSPECT THE | | | DEMO OF THE EXISTING SINK PRIOR TO | | | COVERING. | | | 2. SHT A1.1 BREAK ROOM SINK SHALL BE | | | ACCESSIBLE. PLEASE SHOW THE FOLLOWING ON | | | THE FLOOR PLAN AND THE DETAIL: | | | A. KNEE CLEARANCE 11-4.24.3 | | | B. SINK DEPTH 11-4.24.4 | | | C. CLEAR FLOOR SPACE 11-4.24.5 SHALL BE | | | PROVIDED FOR FORWARD APPROACH AND SHALL | | | ENTEND A MAXIMUM OF 19" UNDERNEATH THE | | | SINK. ALSO NO CABINET DOORS SHALL BE | | | ALLOWED IN THE CLEAR FLOOR SPACE FOR THE | | | SINK. | | | D. EXPOSED PIPES & SURFACES 11-4.24.6 | | | E. FAUCETS 11-4.24.7 | | | SHOW COMPLIANCE WITH ALL THE ABOVE. | | | 3. SHT P-1 WATER ISOMETRIC. WATER HAMMER | | | ARRESTORS ARE REQUIRED FOR ALL QUICK | | | CLOSING VALVES, SUCH AS ICE MAKERS, DISH | | | WASHERS AND/OR WASH MACHINES. THEY SHALL | | | BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING PER | | | PDI-WH 201. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|